NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| GAC Chemical Corporation | |
| P.O. Box 436 | |
| Searsport, ME 04974 | |
| United States | |
| 207-548-2525 |
Facility : # 3 USA
|
Aluminum Chlorohydrate[AL] |
||
| Trade Designation | Product Function | Max Use |
| Aluminum Chlorohydrate | Coagulation & Flocculation Filtration Aid |
250mg/L |
| Gencoag 100Y | Coagulation & Flocculation Filtration Aid |
250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| GenCoag S1 | Coagulation & Flocculation | 325mg/L |
| GenCoag S11 | Coagulation & Flocculation | 325mg/L |
| GenCoag S2 | Coagulation & Flocculation | 325mg/L |
| GenCoag S3 | Coagulation & Flocculation | 325mg/L |
| GenCoag S4 | Coagulation & Flocculation | 250mg/L |
| GenCoag S5 | Coagulation & Flocculation | 325mg/L |
| GenCoag S6 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polymer Blends[AL] [PY] |
||
| Trade Designation | Product Function | Max Use |
| GenCoag S10 | Coagulation & Flocculation | 38mg/L |
| GenCoag S25 | Coagulation & Flocculation | 38mg/L |
| GenCoag S7 | Coagulation & Flocculation | 167mg/L |
| GenCoag S8 | Coagulation & Flocculation | 38mg/L |
| GenCoag S9 | Coagulation & Flocculation | 167mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
|
Sodium Aluminate[AL] |
||
| Trade Designation | Product Function | Max Use |
| 38% Sodium Aluminate Solution | Coagulation & Flocculation pH Adjustment |
40mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
Number of matching Manufacturers is 1
Number of matching Products is 15
Processing time was 0 seconds