NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| EnviroTech Chemical Services, Inc. | |
| 500 Winmoore Way | |
| Modesto, CA 95358 | |
| United States | |
| 888-563-2254 | |
| 209-581-9576 | |
| Visit this company's website |
Facility : Helena, AR
|
Hydrogen Peroxide[HP] |
||
| Trade Designation | Product Function | Max Use |
| Hydrogen Peroxide 27% | Oxidant | 3mg/L |
| Hydrogen Peroxide 34% | Oxidant | 3mg/L |
[HP] Use of this product shall be followed by chlorination to remove levels of hydrogen
peroxide. Chlorine residuals shall not exceed 4 mg/L, the EPA's proposed maximum
residual level.
|
||
|
Miscellaneous Water Supply Products[1] [2] [3] |
||
| Trade Designation | Product Function | Max Use |
| Bioside HS 15% | Membrane Cleaner | NA |
| BromMax 7.1 | Membrane Cleaner | NA |
| Perasan A | Membrane Cleaner | NA |
| REFLEX™ | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[3] Drain and flush system until hydrogen peroxide and peracetic acid concentrations fall
below 1 ppm.
|
||
|
Sodium Chlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| SureCide AH | Bactericide Chlorine Dioxide Production |
11mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
Facility : Modesto, CA
|
Hydrogen Peroxide |
||
| Trade Designation | Product Function | Max Use |
| Hydrogen Peroxide 15% | Oxidant | 3.5mg/L |
| Hydrogen Peroxide 34% | Oxidant | 3mg/L |
| Hydrogen Peroxide 50% | Oxidant | 2.1mg/L |
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| Bioside HS 15%[2] | Membrane Cleaner Reverse Osmosis Antiscalant |
30mg/L |
[2] This product is designed to be used upstream of a carbon absorption system. Use of this
product shall be followed by chlorination to remove trace levels of hydrogen peroxide.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| ECO9000[1] | Other | NA |
| Perasan A[3] [4] [5] | Membrane Cleaner | NA |
| REFLEX™[3] [4] [5] | Membrane Cleaner | NA |
[1] ECO 9000 is used offline to remove deposits from water tank surfaces. It is used in a
10:1 ratio at a rate of 60 mg/L with Hydrogen Peroxide 34%. The tank is rinsed to
remove any residual product before returning to service.
[3] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[5] Drain and flush system until the hydrogen peroxide and peracetic acid concentrations
fall below 1 ppm.
|
||
|
Sodium Chlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| SureCide AH | Chlorine Dioxide Production Bactericide |
11mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||