NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| National Chemical & Petroleum Industries Co. W.L.L. | |
| Block 4, Road Ma-7 | |
| Shuaibah Industrial Area | |
| Shuaibah, Ahmadi 65454 | |
| Kuwait | |
| 965 326 2266 | |
| Visit this company's website |
Facility : Shuaibah, Kuwait
|
Aminotrimethylene Phosphonic Acid |
||
| Trade Designation | Product Function | Max Use |
| NCP Treat - 54 | Distillation Antiscalant Reverse Osmosis Antiscalant |
4mg/L |
|
Miscellaneous Chemical Products |
||
| Trade Designation | Product Function | Max Use |
| NCP DS 3000 | Distillation Antiscalant | 20mg/L |
|
Miscellaneous Treatment Applications |
||
| Trade Designation | Product Function | Max Use |
| NCP DS 4000 | Distillation Antiscalant | 20mg/L |
| NCP DS 5000 | Distillation Antiscalant | 20mg/L |
| NCP DS 6000 | Distillation Antiscalant | 20mg/L |
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| NCP Treat - 35 | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| NCP Treat - 50 | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| NCP Treat - 73 | Distillation Antiscalant Reverse Osmosis Antiscalant |
1mg/L |
| NCP Treat - 88 | Distillation Antiscalant Reverse Osmosis Antiscalant |
4mg/L |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| NCP FOAM 605[3] | Antifoamer | 5mg/L |
| NCP Treat 177[1] | NA | |
| NCP Treat 186[1] | NA | |
| NCP Treat 223[1] | Reverse Osmosis Membrane Biocide | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions. The PH of the influent
and effluent water should be monitored to ensure that all traces of the product have
been removed before placing into service.
[3] Certified for addition to the feedwater for evaporative desalination units only.
|
||
|
Polymer Blends |
||
| Trade Designation | Product Function | Max Use |
| NCP Treat 335[AL] | Coagulation & Flocculation | 50mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Sodium Bisulfate |
||
| Trade Designation | Product Function | Max Use |
| NCP Treat 261[2] | Dechlorination | 18mg/L |
[2] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is ppb (0.1 mg/L).
|
||
Facility : Mesaeed, Qatar at Al Watanya Chemical Industries
|
Miscellaneous Chemical Products |
||
| Trade Designation | Product Function | Max Use |
| NCP DS 3000 | Distillation Antiscalant | 20mg/L |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| NCP FOAM 605[1] | Antifoamer | 5mg/L |
[1] Certified for addition to the feedwater for evaporative desalination units only. |
||