NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 29, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsChemicals/Listings.asp?Company=23740&Standard=060&
NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| Holland Company, Inc. | |
| 153 Howland Avenue | |
| Adams, MA 01220 | |
| United States | |
| 413-743-1292 |
Facility : Adams, MA
|
Aluminum Chlorohydrate[AL] |
||
| Trade Designation | Product Function | Max Use |
| PACL 800 | Filtration Aid Coagulation & Flocculation |
250mg/L |
| PC 2800 | Filtration Aid Coagulation & Flocculation |
250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Aluminum Sulfate[AL] |
||
| Trade Designation | Product Function | Max Use |
| Aluminum Sulfate Hydrate - Basic | Coagulation & Flocculation | 150mg/L |
| Commercial Liquid Aluminum Sulfate | Coagulation & Flocculation | 150mg/L |
| Iron Free Liquid Aluminum Sulfate | Coagulation & Flocculation | 150mg/L |
| LBA-100 | Coagulation & Flocculation | 150 mg/L |
| LBA-200 | Coagulation & Flocculation | 150 mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Blended Coagulation Chemicals[AL] [PY] |
||
| Trade Designation | Product Function | Max Use |
| LBA 105 | Coagulation & Flocculation | 151 mg/L |
| LBA 205 | Coagulation & Flocculation | 151 mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| EPIC 525 | Coagulation & Flocculation | 275mg/L |
| EPIC 625 | Coagulation & Flocculation | 275mg/L |
| EPIC WW 58 | Coagulation & Flocculation | 325mg/L |
| EPIC WW 59 | Coagulation & Flocculation | 325mg/L |
| EPIC WW 70 | Coagulation & Flocculation | 250mg/L |
| HC 4000 | Coagulation & Flocculation Filtration Aid |
275mg/L |
| HC 5000 | Coagulation & Flocculation Filtration Aid |
275mg/L |
| PACL 100 | Coagulation & Flocculation | 325mg/L |
| PACL 101 | Coagulation & Flocculation | 325mg/L |
| PACL 102 | Coagulation & Flocculation | 325mg/L |
| PACL 103 | Coagulation & Flocculation | 325mg/L |
| PACL 104 | Coagulation & Flocculation | 325mg/L |
| PACL 105 | Coagulation & Flocculation | 325mg/L |
| PACL 106 | Coagulation & Flocculation | 325mg/L |
| PACL 107 | Coagulation & Flocculation | 325mg/L |
| PACL 108 | Coagulation & Flocculation | 325mg/L |
| PACL 109 | Coagulation & Flocculation | 325mg/L |
| PACL200 | Coagulation & Flocculation | 250mg/L |
| PACL201 | Coagulation & Flocculation | 250mg/L |
| PACL202 | Coagulation & Flocculation | 250mg/L |
| PACL203 | Coagulation & Flocculation | 250mg/L |
| PACL204 | Coagulation & Flocculation | 250mg/L |
| PACL205 | Coagulation & Flocculation | 250mg/L |
| PACL300 | Coagulation & Flocculation | 250mg/L |
| PACL301 | Coagulation & Flocculation | 250mg/L |
| PACL302 | Coagulation & Flocculation | 250mg/L |
| PACL303 | Coagulation & Flocculation | 250mg/L |
| PACL304 | Coagulation & Flocculation | 250mg/L |
| PACL305 | Coagulation & Flocculation | 250mg/L |
| PC 600 | Coagulation & Flocculation | 250mg/L |
| PC 601 | Coagulation & Flocculation | 250mg/L |
| PC 602 | Coagulation & Flocculation | 250mg/L |
| PC 603 | Coagulation & Flocculation | 250mg/L |
| PC 604 | Coagulation & Flocculation | 250mg/L |
| PC 605 | Coagulation & Flocculation | 250mg/L |
| PC 610 | Coagulation & Flocculation | 250mg/L |
| PC 611 | Coagulation & Flocculation | 250mg/L |
| PC 612 | Coagulation & Flocculation | 250mg/L |
| PC 613 | Coagulation & Flocculation | 250mg/L |
| PC 614 | Coagulation & Flocculation | 250mg/L |
| PC 615 | Coagulation & Flocculation | 250mg/L |
| PCH 100 | Coagulation & Flocculation | 325mg/L |
| PCH 101 | Coagulation & Flocculation | 325mg/L |
| PCH 102 | Coagulation & Flocculation | 325mg/L |
| PCH 103 | Coagulation & Flocculation | 325mg/L |
| PCH 104 | Coagulation & Flocculation | 325mg/L |
| PCH 105 | Coagulation & Flocculation | 325mg/L |
| PCH 180 | Coagulation & Flocculation | 325mg/L |
| PCH 181 | Coagulation & Flocculation | 325mg/L |
| PCH 182 | Coagulation & Flocculation | 325mg/L |
| PCH 183 | Coagulation & Flocculation | 325mg/L |
| PCH 184 | Coagulation & Flocculation | 325mg/L |
| PCH 185 | Coagulation & Flocculation | 325mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polymer Blends[AL] [PY] |
||
| Trade Designation | Product Function | Max Use |
| PACL 103-5 | Coagulation & Flocculation | 167mg/L |
| PACL 108-10 | Coagulation & Flocculation | 38mg/L |
| PACL 108-25 | Coagulation & Flocculation | 38mg/L |
| PACL 108-5 | Coagulation & Flocculation | 167mg/L |
| PACL 109-5 | Coagulation & Flocculation | 167mg/L |
| PACL 300-10 | Coagulation & Flocculation | 38mg/L |
| PACL 300-25 | Coagulation & Flocculation | 38mg/L |
| PACL 300-5 | Coagulation & Flocculation | 167mg/L |
| PC 2300 | Coagulation & Flocculation | 167mg/L |
| PC 2301 | Coagulation & Flocculation | 38mg/L |
| PC 2302 | Coagulation & Flocculation | 167mg/L |
| PC 2303 | Coagulation & Flocculation | 38mg/L |
| PC 2305 | Coagulation & Flocculation | 38mg/L |
| PC 2380 | Coagulation & Flocculation | 167mg/L |
| PC 2381 | Coagulation & Flocculation | 38mg/L |
| PC 2382 | Coagulation & Flocculation | 38mg/L |
| PC 2384 | Coagulation & Flocculation | 38mg/L |
| PC 2385 | Coagulation & Flocculation | 38mg/L |
| PC 2500 | Coagulation & Flocculation | 38mg/L |
| PC 2510 | Coagulation & Flocculation | 38mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
|
Sodium Aluminate[AL] |
||
| Trade Designation | Product Function | Max Use |
| Sodium Aluminate | Coagulation & Flocculation pH Adjustment |
40 mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Sodium Bisulfite[1] |
||
| Trade Designation | Product Function | Max Use |
| SAF D-CHLOR | Dechlorinator & Antioxidant | 60mg/L |
| SBS | Dechlorinator & Antioxidant | 60mg/L |
| Sodium Bisulfite - 25% | Dechlorinator & Antioxidant | 90mg/L |
| Sodium Bisulfite Solution | Dechlorinator & Antioxidant | 60mg/L |
| Sodium Bisulfite Solution 25% | Dechlorinator & Antioxidant | 60mg/L |
| Sodium Bisulfite Solution 38% | Dechlorinator & Antioxidant | 60mg/L |
| Stabilized Bisulfite Solution | Dechlorinator & Antioxidant | 60mg/L |
[1] This product contains sulfite. |
||
Number of matching Manufacturers is 1
Number of matching Products is 90
Processing time was 1 seconds

