NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| Water Systems Engineering, Inc. | |
| 3201 Labette Terrace | |
| P.O. Box 700 | |
| Ottawa, KS 66067 | |
| United States | |
| 785-242-6166 |
Facility : Ottawa, KS
|
Hydrochloric Acid |
||
| Trade Designation | Product Function | Max Use |
| Descale Shield Liquid Acid[1] | Well Cleaning Aid Well Rehabilitation Aid |
NA |
| NW-130 HCL[2] [3] | Well Cleaning Aid | NA |
| NW-130 HCL | Descaler | 40mg/L |
| NW-140[1] | Well Cleaning Aid Well Rehabilitation Aid |
NA |
| Nu-Well 130 Mineral Acid | Descaler | 40mg/L |
| Nu-Well 130 Mineral Acid[2] [3] | Well Cleaning Aid | NA |
| NuWell 140[1] | Well Cleaning Aid Well Rehabilitation Aid |
NA |
[1] The well is to be properly flushed and drained before being placed in service.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[3] This product is designed to be used off-line following manufacturer’s use instructions.
The well is to be flushed until the turbidity of the water is < 1 NTU before the system
may be used for drinking water.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| H-34[2] [4] [5] [6] | Well Cleaning Aid | NA |
| H-34[2] [4] [5] [6] | Pipe Cleaning Aid | NA |
| HES-16A[5] [7] | Well Cleaning Aid Pipe Cleaning Aid |
NA |
| NW-100[8] | Well Cleaning Aid Well Rehabilitation Aid |
NA |
| NW-110[8] | Well Cleaning Aid Well Rehabilitation Aid |
NA |
| Nu Well[8] | Well Cleaning Aid Well Rehabilitation Aid |
NA |
| TC-1[9] | Other Pipe Cleaning Aid |
NA |
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[4] H-234, H-34, and H-39 are also used as filter cleaning aids.
[5] These products are designed to be flushed out prior to using the system for drinking
water. The system is to be properly flushed and drained following the manufacturer's use
instructions.
[6] This product may be used at 5% provided the equipment is disconnected from the system
before treatment and flushed until the pH returns to normal.
[7] This product has been Certified for use as a well cleaning aid only when used in
conjunction with sodium or calcium hypochlorite.
[8] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[9] Certified for use as a pipe cleaning aid and surface area cleaner. This product is
designed to be flushed out prior to using the system for drinking water.
|
||
|
Phosphoric Acid |
||
| Trade Designation | Product Function | Max Use |
| NW-120[2] [3] | Well Cleaning Aid | NA |
| Nu-Well 120 | Descaler | 13mg/L |
| Nu-Well 120 Mineral Acid | Descaler | 13mg/L |
| Nu-Well 120 Mineral Acid[2] [3] | Well Cleaning Aid | NA |
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[3] This product is designed to be used off-line following manufacturer’s use instructions.
The well is to be flushed until the turbidity of the water is < 1 NTU before the system
may be used for drinking water.
|
||
|
Sodium Dichloroisocyanurate [CL] |
||
| Trade Designation | Product Function | Max Use |
| Chlor-Right[2] [3] | Well Cleaning Aid | NA |
| Chlor-Right | Disinfection & Oxidation | 30mg/L |
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[3] This product is designed to be used off-line following manufacturer’s use instructions.
The well is to be flushed until the turbidity of the water is < 1 NTU before the system
may be used for drinking water.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
Number of matching Manufacturers is 1
Number of matching Products is 20
Processing time was 0 seconds