NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsChemicals/Listings.asp?Company=43980&Standard=060&


NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects



 
Water Systems Engineering, Inc. 
3201 Labette Terrace
P.O. Box 700 
Ottawa, KS 66067 
United States 
785-242-6166

Facility : Ottawa, KS


Hydrochloric Acid
Trade Designation Product Function Max Use
Descale Shield Liquid Acid[1] Well Cleaning Aid
Well Rehabilitation Aid
NA
NW-130 HCL[2] [3] Well Cleaning Aid NA
NW-130 HCL Descaler 40mg/L
NW-140[1] Well Cleaning Aid
Well Rehabilitation Aid
NA
Nu-Well 130 Mineral Acid Descaler 40mg/L
Nu-Well 130 Mineral Acid[2] [3] Well Cleaning Aid NA
NuWell 140[1] Well Cleaning Aid
Well Rehabilitation Aid
NA

[1] The well is to be properly flushed and drained before being placed in service.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
    of the product have been removed before placing into service.
[3] This product is designed to be used off-line following manufacturer’s use instructions. 
    The well is to be flushed until the turbidity of the water is < 1 NTU before the system
    may be used for drinking water.

Miscellaneous Water Supply Products
Trade Designation Product Function Max Use
H-34[2] [4] [5] [6] Well Cleaning Aid NA
H-34[2] [4] [5] [6] Pipe Cleaning Aid NA
HES-16A[5] [7] Well Cleaning Aid
Pipe Cleaning Aid
NA
NW-100[8] Well Cleaning Aid
Well Rehabilitation Aid
NA
NW-110[8] Well Cleaning Aid
Well Rehabilitation Aid
NA
Nu Well[8] Well Cleaning Aid
Well Rehabilitation Aid
NA
TC-1[9] Other
Pipe Cleaning Aid
NA

[2] The pH of the influent and effluent water should be monitored to ensure that all traces
    of the product have been removed before placing into service.
[4] H-234, H-34, and H-39 are also used as filter cleaning aids.
[5] These products are designed to be flushed out prior to using the system for drinking
    water. The system is to be properly flushed and drained following the manufacturer's use
    instructions.
[6] This product may be used at 5% provided the equipment is disconnected from the system
    before treatment and flushed until the pH returns to normal.
[7] This product has been Certified for use as a well cleaning aid only when used in
    conjunction with sodium or calcium hypochlorite.
[8] This product is designed to be used off-line and flushed out prior to using the system
    for drinking water, following manufacturer's use instructions.
[9] Certified for use as a pipe cleaning aid and surface area cleaner.  This product is
    designed to be flushed out prior to using the system for drinking water.

Phosphoric Acid
Trade Designation Product Function Max Use
NW-120[2] [3] Well Cleaning Aid NA
Nu-Well 120 Descaler 13mg/L
Nu-Well 120 Mineral Acid Descaler 13mg/L
Nu-Well 120 Mineral Acid[2] [3] Well Cleaning Aid NA

[2] The pH of the influent and effluent water should be monitored to ensure that all traces
    of the product have been removed before placing into service.
[3] This product is designed to be used off-line following manufacturer’s use instructions. 
    The well is to be flushed until the turbidity of the water is < 1 NTU before the system
    may be used for drinking water.

Sodium Dichloroisocyanurate [CL]
Trade Designation Product Function Max Use
Chlor-Right[2] [3] Well Cleaning Aid NA
Chlor-Right Disinfection & Oxidation 30mg/L

[2] The pH of the influent and effluent water should be monitored to ensure that all traces
    of the product have been removed before placing into service.
[3] This product is designed to be used off-line following manufacturer’s use instructions. 
    The well is to be flushed until the turbidity of the water is < 1 NTU before the system
    may be used for drinking water.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
     dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
     finished drinking water to ensure compliance to all applicable regulations.


Number of matching Manufacturers is 1
Number of matching Products is 20
Processing time was 0 seconds