NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| Nalco Company | |
| 1600 West Diehl Road | |
| Naperville, IL 60563 | |
| United States | |
| 630-305-1000 |
Facility : # 38 USA
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| Nalco 8117 | Coagulation & Flocculation | 250mg/L |
| Ultrion™ 8187 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polymer Blends[AL] |
||
| Trade Designation | Product Function | Max Use |
| Nalco 8140 | Coagulation & Flocculation | 181mg/L |
| Nalco 8176 | Coagulation & Flocculation | 30mg/L |
| Nalco 8177 | Coagulation & Flocculation | 89mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
Facility : # 39 USA
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| Nalco 8117 | Coagulation & Flocculation | 250mg/L |
| Nalco 8134 | Coagulation & Flocculation | 250mg/L |
| Nalco 8136 | Coagulation & Flocculation | 250mg/L |
| Nalco 8138 | Coagulation & Flocculation | 250mg/L |
| Nalco 8158 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polymer Blends[AL] [PY] |
||
| Trade Designation | Product Function | Max Use |
| Nalco 8140 | Coagulation & Flocculation | 181mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
Facility : # 40 USA
|
Aluminum Chlorohydrate[AL] |
||
| Trade Designation | Product Function | Max Use |
| Nalco 8117 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| Nalco 8117 | Coagulation & Flocculation | 250mg/L |
| Nalco 8134 | Coagulation & Flocculation | 250mg/L |
| Nalco 8136 | Coagulation & Flocculation | 250mg/L |
| Nalco 8138 | Coagulation & Flocculation | 250mg/L |
| Nalco 8158 | Coagulation & Flocculation | 250mg/L |
| Ultrion™ 8187 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polymer Blends[AL] [PY] |
||
| Trade Designation | Product Function | Max Use |
| Nalco 8140 | Coagulation & Flocculation | 181mg/L |
| Nalco 8176 | Coagulation & Flocculation | 60mg/L |
| Nalco 8177 | Coagulation & Flocculation | 89mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
Number of matching Manufacturers is 1