NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsChemicals/Listings.asp?Company=C0035421&Standard=060&


NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects



 
Chemstream, Inc. 
511 Railroad Avenue
Homer City, PA 15748 
United States 
866-629-7118 
724-915-8388
Visit this company's website

Facility : West Frankfort, IL


Aluminum Chlorohydrate[AL]
Trade Designation Product Function Max Use
ChemPAC 100 Coagulation & Flocculation 250mg/L

[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
     drinking water shall not exceed 2 mg/L.

Aluminum Sulfate[AL]
Trade Designation Product Function Max Use
Alsulant 570 Coagulation & Flocculation 150mg/L

[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
     drinking water shall not exceed 2 mg/L.

Ammonium Sulfate
Trade Designation Product Function Max Use
Ammonium Sulfate 20% NSF Chloramination 120mg/L
Ammonium Sulfate 40% Chloramination 60mg/L

Citric Acid
Trade Designation Product Function Max Use
50% Citric Acid[1] [2] Membrane Cleaner NA

[1] This product is designed to be used off-line and flushed out prior to using the system
    for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
    of the product have been removed before placing into service.

Ferric Sulfate
Trade Designation Product Function Max Use
50% Ferric Sulfate Coagulation & Flocculation 600mg/L

Hydrofluosilicic Acid
Trade Designation Product Function Max Use
Hydrofluorosilicic Acid Fluoridation 5mg/L

Poly (Diallyldimethylammonium Chloride)(pDADMAC)
Trade Designation Product Function Max Use
Envirofloc CF-545 Coagulation & Flocculation 50mg/L

Polyacrylamide[PC]
Trade Designation Product Function Max Use
LiquiFloc 125 Coagulation & Flocculation
Flocculant
100mg/L
LiquiFloc 1974 Coagulation & Flocculation 2mg/L

[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
     requirements for percent monomer and dose.

Polymer Blends[AL]
Trade Designation Product Function Max Use
Alsulant 570 SB Coagulation & Flocculation 150mg/L
ChemPAC 100 SB Coagulation & Flocculation 125mg/L

[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
     drinking water shall not exceed 2 mg/L.

Sodium Chlorite[CL]
Trade Designation Product Function Max Use
Sodium Chlorite 25% Chlorine Dioxide Production 22mg/L

[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
     dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
     finished drinking water to ensure compliance to all applicable regulations.

Sodium Hydroxide
Trade Designation Product Function Max Use
Alka-Trete 250 pH Adjustment 200mg/L
Alka-Trete 500 pH Adjustment 100mg/L

Sodium Hypochlorite[HY]
Trade Designation Product Function Max Use
CHEMCHLOR 160 Disinfection & Oxidation 40mg/L

[HY] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
     dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
     finished drinking water to ensure compliance to all applicable regulations. Also,
     reference the AWWA B300 (Hypochlorites) standard's Recommendations for the Handling and
     Storage of Hypochlorite Solutions appendix for information on preservation techniques
     for hypochlorite bleach in transit and storage.

Sodium Permanganate[PO]
Trade Designation Product Function Max Use
ChemOx 200 Disinfection & Oxidation 176mg/L
ChemOx 400 Oxidant 88mg/L

[PO] The finished drinking water shall be monitored to ensure that levels of manganese

     do not exceed 0.05 mg/L.


Facility : Mingo Junction, OH


Poly (Diallyldimethylammonium Chloride)(pDADMAC)[1]
Trade Designation Product Function Max Use
StimSTREAM FR 9800 Well Drilling Aid NA

[1] These products are designed to be flushed out prior to using the system for drinking
    water. Before being placed into service, the well is to be properly flushed according to
    the manufacturer's use instructions. Certification of these products is based on the
    well drilling model with the following assumptions:
    - The amount of well drilling fluid used is 3780 L (1000 U.S. gallons) to which the 
      drilling fluid has been added at the manufacturer's recommended level.
    - The aquifer contains 3.1 million liters of water (815,000 gallons) based on a 0.5 
      acre aquifer of 6.1 meter depth (20 ft.) and 25% porosity.
    - The bore hole is 61 meters in total depth (200 ft.), the screen is 6.1 meters in 
      length (20 ft.), and the bore hole is 25.4 cm. in diameter (10 in.).
    - The amount of well drilling fluid removed from the well during construction is equal 
      to the combined volumes of the casing and the screen, plus an additional amount 
      removed through the well disinfection and development (90% removed).
    - This product should not be used in constructing wells in highly porous formations, 
      such as cavernous limestone.


Facility : Montoursville, PA


Poly (Diallyldimethylammonium Chloride)(pDADMAC)[1]
Trade Designation Product Function Max Use
StimSTREAM FR 9800 Well Drilling Aid NA

[1] These products are designed to be flushed out prior to using the system for drinking
    water. Before being placed into service, the well is to be properly
    flushed according to the manufacturer's use instructions. Certification of these
    products is based on the well drilling model with the following assumptions:
    - The amount of well drilling fluid used is 3780 L (1000 U.S. gallons) to which the
    drilling fluid has been added at the manufacturer's recommended level.
    - The aquifer contains 3.1 million liters of water (815,000 gallons) based on a 0.5 acre
    aquifer of 6.1 meter depth (20 ft.) and 25% porosity.
    - The bore hole is 61 meters in total depth (200 ft.), the screen is 6.1 meters in
    length (20 ft.), and the bore hole is 25.4 cm. in diameter (10 in.).
    - The amount of well drilling fluid removed from the well during construction is equal
    to the combined volumes of the casing and the screen, plus an additional amount removed
    through the well disinfection and development (90% removed).
    - This product should not be used in constructing wells in highly porous formations,
    such as cavernous limestone.


Facility : Stoystown, PA


Aluminum Chlorohydrate[AL]
Trade Designation Product Function Max Use
ChemPAC 70 Coagulation & Flocculation 250mg/L
ChemPAC 90 Coagulation & Flocculation 250mg/L
DelPAC 2000 Coagulation & Flocculation 250mg/L
DelPAC 2020 Coagulation & Flocculation 250mg/L

[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
     drinking water shall not exceed 2 mg/L.

Blended Phosphates
Trade Designation Product Function Max Use
AQUA MAGĀ® Corrosion & Scale Control
Sequestering
23mg/L
Chemsoft 350 Corrosion & Scale Control
Sequestering
28mg/L

Calcium Hydroxide
Trade Designation Product Function Max Use
AlkaLime 380 pH Adjustment
Precipitation Agent
1000mg/L

Citric Acid
Trade Designation Product Function Max Use
50% Citric Acid[2] Membrane Cleaner
Well Cleaning Aid
NA

[2] This product is designed to be used off-line and flushed out prior to using the system
    for drinking water, following manufacturer's use instructions.

Hydrofluosilicic Acid
Trade Designation Product Function Max Use
Hydrofluosilicic Acid Fluoridation 5mg/L

Miscellaneous Chemical Products
Trade Designation Product Function Max Use
MW-1 Coagulation & Flocculation 100mg/L

Polyaluminum Chloride[AL]
Trade Designation Product Function Max Use
ChemPAC 70 Coagulation & Flocculation 250mg/L
ChemPAC 90 Coagulation & Flocculation 250mg/L
DelPAC 2000 Coagulation & Flocculation 250mg/L
DelPAC 2020 Coagulation & Flocculation 250mg/L

[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
     drinking water shall not exceed 2 mg/L.

Potassium Carbonate
Trade Designation Product Function Max Use
K-ALK 470 pH Adjustment 100mg/L

Sodium Bisulfite[1]
Trade Designation Product Function Max Use
Sodium Bisulfite 38-42% Dechlorination
Corrosion & Scale Control
50mg/L

[1] This product contains sulfite.
   Sulfites have been known to cause potentially lethal allergic reactions in sulfite-sensitive individuals.
   The maximum recommended allowable residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).

Sodium Hydroxide
Trade Designation Product Function Max Use
Alka-Trete 200 pH Adjustment 250mg/L
Alka-Trete 250 pH Adjustment 200mg/L
Alka-Trete 500 pH Adjustment 100mg/L

Sodium Hypochlorite[HY]
Trade Designation Product Function Max Use
CHEMCHLOR 160 Disinfection & Oxidation 56mg/L

[HY] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
     dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
     finished drinking water to ensure compliance to all applicable regulations. Also,
     reference the AWWA B300 (Hypochlorites) standard's Recommendations for the Handling and
     Storage of Hypochlorite Solutions appendix for information on preservation techniques
     for hypochlorite bleach in transit and storage.

[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
     requirements for percent monomer and dose.

Number of matching Manufacturers is 1
Number of matching Products is 40
Processing time was 0 seconds