NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsChemicals/Listings.asp?Company=C0067003&Standard=060&
NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| Grasim Industries Limited, Chemical Division | |
| Birlagram, Nagda, District Ujjain | |
| Madhya Pradesh 456331 | |
| India | |
| 91 736 6245848 | |
| Visit this company's website |
Facility : Andhra Pradesh, India
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| CAUSTIC SODA FLAKES | pH Adjustment Corrosion & Scale Control |
800mg/L |
Facility : Gujarat, India
|
Aluminum Chlorohydrate[AL] |
||
| Trade Designation | Product Function | Max Use |
| Aluminium Chlorohydrate | Coagulation & Flocculation | 250mg/L |
| VYTAL HBC Supra | Coagulation & Flocculation | 250mg/L |
| VYTAL S Co | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Calcium Hypochlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| AQUA ARMOR HSD Prime | Disinfection & Oxidation Algicide |
10mg/L |
| POWEFRIT IPC | Disinfection & Oxidation Algicide |
10mg/L |
| RENSA HS Bleach | Disinfection & Oxidation Algicide |
10mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| AC/100S | Coagulation & Flocculation | 200mg/L |
| ARYAPAC | Coagulation & Flocculation | 200mg/L |
| POLYALUMINIUM CHLORIDE (LIQUID) | Coagulation & Flocculation | 200mg/L |
| SAB 18 | Coagulation & Flocculation | 200mg/L |
| SAB 18 Plus (Liquid) | Coagulation & Flocculation | 200mg/L |
| SAB 18 Plus (Powder) | Coagulation & Flocculation | 200mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polymer Blends[AL] |
||
| Trade Designation | Product Function | Max Use |
| Vytal 3305 | Coagulation & Flocculation | 250mg/L |
| Vytal 3306 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| CAUSTIC SODA FLAKES | Corrosion & Scale Control pH Adjustment |
800mg/L |
Facility : Jharkhand, India
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| AC 100S Liquid | Coagulation & Flocculation | 200mg/L |
| AC 100S Powder | Coagulation & Flocculation | 200mg/L |
| ARYA PAC Liquid | Coagulation & Flocculation | 200mg/L |
| ARYA PAC Powder | Coagulation & Flocculation | 200mg/L |
| SAB 18 Liquid | Coagulation & Flocculation | 200mg/L |
| SAB 18 Powder | Coagulation & Flocculation | 200mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| CAUSTIC SODA FLAKES | Corrosion & Scale Control pH Adjustment |
800mg/L |
Facility : Madhya Pradesh, India
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| AC/100S | Coagulation & Flocculation | 200mg/L |
| ARYAPAC | Coagulation & Flocculation | 200mg/L |
| POLYALUMINIUM CHLORIDE (LIQUID) | Coagulation & Flocculation | 200mg/L |
| SAB 18 | Coagulation & Flocculation | 200mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
Facility : Odisha, India
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| AC100S (Liquid) | Coagulation & Flocculation | 200mg/L |
| AC100S (Powder) | Coagulation & Flocculation | 200mg/L |
| ARYAPAC (Liquid) | Coagulation & Flocculation | 200mg/L |
| ARYAPAC (Powder) | Coagulation & Flocculation | 200mg/L |
| SAB 18 (Liquid) | Coagulation & Flocculation | 200mg/L |
| SAB 18 (Powder) | Coagulation & Flocculation | 200mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
Facility : Renukoot, India
|
Hydrochloric Acid |
||
| Trade Designation | Product Function | Max Use |
| Hydrochloric Acid | Corrosion & Scale Control Descaler |
50mg/L |
Facility : Veraval, Gujarat, India
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| CAUSTIC SODA FLAKES | Corrosion & Scale Control pH Adjustment |
800mg/L |
Number of matching Manufacturers is 1
Number of matching Products is 35
Processing time was 0 seconds

