NSF Product and Service Listings

These NSF Official Listings are current as of Friday, July 26, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsChemicals/Listings.asp?Company=C0067061&Standard=060&


NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects



 
AquaSol Corporation 
730 North Anderson Road
Rock Hill, SC 29730 
United States 
803-327-3833
Visit this company's website

Facility : Rock Hill, SC


Miscellaneous Treatment Applications
Trade Designation Product Function Max Use
ClayBloc Plus Coagulation & Flocculation 111mg/L

Miscellaneous Water Supply Products[1]
Trade Designation Product Function Max Use
AquaBore Well Drilling Aid NA
AquaSlic Well Drilling Aid NA
AquaVisc HDD Well Drilling Aid NA
AquaVisc HDD Plus Well Drilling Aid
Drilling Fluid
NA
Aquabloc D Well Drilling Aid
Drilling Fluid
NA
Aquabloc LC Well Drilling Aid
Drilling Fluid
NA
Aquadril D Well Drilling Aid
Drilling Fluid
NA
Aquadril LC Well Drilling Aid
Drilling Fluid
NA
ClayBloc Well Drilling Aid
Drilling Fluid
NA
ClayBloc Plus Well Drilling Aid
Drilling Fluid
NA

[1] These products are designed to be flushed out prior to using the system for drinking
    water. Before being placed into service, the well is to be properly flushed according to
    the manufacturer's use instructions. Certification of these products is based on the
    well drilling model with the following assumptions:
    - The amount of well drilling fluid used is 3780 L (1000 U.S. gallons) to which the
    drilling fluid has been added at the manufacturer's recommended level.
    - The aquifer contains 3.1 million liters of water (815,000 gallons) based on a 0.5 acre
    aquifer of 6.1 meter depth (20 ft.) and 25% porosity.
    - The bore hole is 61 meters in total depth (200 ft.), the screen is 6.1 meters in
    length (20 ft.), and the bore hole is 25.4 cm. in diameter (10 in.).
    - The amount of well drilling fluid removed from the well during construction is equal
    to the combined volumes of the casing and the screen, plus an additional amount removed
    through the well disinfection and development (90% removed).
    - This product should not be used in constructing wells in highly porous formations,
    such as cavernous limestone.
    
    Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
    requirements for percent monomer and dose.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Number of matching Manufacturers is 1
Number of matching Products is 11
Processing time was 0 seconds