Aluminum Chlorohydrate[1] [AL] |
||
| Trade Designation | Product Function | Max Use |
| Aluminum Chlorohydrate (ACH) | Coagulation & Flocculation | 250mg/L |
| Poly Aluminum Chloride (PAC) | Coagulation & Flocculation | 250mg/L |
[1] Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Citric Acid[3] [4] |
||
| Trade Designation | Product Function | Max Use |
| HYDRO 277 | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent should be monitored to ensure that all traces of the
product have been removed before placing into service.
|
||
|
Miscellaneous Treatment Applications[1] |
||
| Trade Designation | Product Function | Max Use |
| Betagard 6000 | Reverse Osmosis Antiscalant | 15mg/L |
| Hydro 600 | Reverse Osmosis Antiscalant | 15mg/L |
[1] Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
|
||
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| BETAGARD 2170 Boiler Scale Preventative | Distillation Antiscalant | 1mg/L |
| HYDRO 259 | Reverse Osmosis Membrane Biocide | 1mg/L |
| HYDRO 473 Boiler Scale Preventative | Distillation Antiscalant | 1mg/L |
| TERRACHEM B440 Boiler Scale Preventative | Distillation Antiscalant | 1mg/L |
|
Miscellaneous Water Supply Products[3] [4] |
||
| Trade Designation | Product Function | Max Use |
| HYDRO 566 | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent should be monitored to ensure that all traces of the
product have been removed before placing into service.
|
||
|
Polyaluminum Chloride[1] [AL] |
||
| Trade Designation | Product Function | Max Use |
| Aluminum Chlorohydrate (ACH) | Coagulation & Flocculation | 250mg/L |
| Poly Aluminum Chloride (PAC) | Coagulation & Flocculation | 250mg/L |
[1] Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| BETAGARD 2040 SERIES Alkalinity Control Agent pH Booster | pH Adjustment | 100mg/L |
| HYDRO 588 Alkalinity Control Agent & Neutralizing Chemical | pH Adjustment | 100mg/L |
| HYDRO 590 Alkalinity Control Agent & Neutralizing Chemical | pH Adjustment | 100mg/L |
| HYDRO 591 Alkalinity Control Agent & Neutralizing Chemical | pH Adjustment | 100mg/L |
| HYDRO 595 Alkalinity Control Agent & Neutralizing Chemical | pH Adjustment | 100mg/L |
| TERRACHEM B900 Alkalinity Control Agent pH Booster | pH Adjustment | 100mg/L |
|
Sodium Metabisulfite[2] |
||
| Trade Designation | Product Function | Max Use |
| HYDRO 200 | Dechlorinator & Antioxidant | 30mg/L |
[2] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
|
||
|
Trisodium Orthophosphate |
||
| Trade Designation | Product Function | Max Use |
| BETAGARD 2200 BOILER SCALE CONTROL | pH Adjustment Scale Control |
17mg/L |
| HYDRO 1020 BOILER SCALE CONTROL | pH Adjustment Scale Control |
17mg/L |
| TERRACHEM B400 BOILER SCALE CONTROL | pH Adjustment Scale Control |
17mg/L |