NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsChemicals/Listings.asp?Company=C0362610&Standard=060&
NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| ZI-Techasia Singapore Pte Ltd. | |
| 50 Raffles Place | |
| #32-01 Singapore Land Tower | |
| 048623 | |
| Singapore | |
| 66 2 656 8710 54 | |
| Visit this company's website |
Facility : Bangkok, Thailand
|
Aluminum Chlorohydrate[AL] |
||
| Trade Designation | Product Function | Max Use |
| ZI-CHEM 7130 | Coagulation & Flocculation | 250mg/L |
| ZI-CHEM 7180 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Chlorine Dioxide Ingredients[1] [CL] |
||
| Trade Designation | Product Function | Max Use |
| ZI-CHEM 2320 | Disinfection & Oxidation | 2mg/L |
| ZI-CHEM 2560 | Disinfection & Oxidation | 2mg/L |
[1] ZI-CHEM 2320 and ZI-CHEM 2560 are to be mixed at a 1:1 ratio to produce 0.15% chlorine
dioxide solution. Certification applies to the finished product.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| ZI-CHEM 6130 | Reverse Osmosis Antiscalant | 20mg/L |
|
Polyacrylamide[PC] |
||
| Trade Designation | Product Function | Max Use |
| ZI-CHEM 7203 | Flocculant | 1mg/L |
| ZI-CHEM 7211 | Flocculant | 1mg/L |
| ZI-CHEM 7225 | Flocculant | 1mg/L |
| ZI-CHEM 7252 | Flocculant | 1mg/L |
| ZI-CHEM 7253 | Flocculant | 1mg/L |
| ZI-CHEM 7255 | Flocculant | 1mg/L |
| ZI-CHEM 72F1 | Flocculant | 1mg/L |
| ZI-CHEM 72JI | Flocculant | 1mg/L |
[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
requirements for percent monomer and dose.
|
||
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| ZI-CHEM 7120 | Coagulation & Flocculation | 50mg/L |
| ZI-CHEM 7121 | Coagulation & Flocculation | 50mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polyamines[PY] |
||
| Trade Designation | Product Function | Max Use |
| ZI-CHEM 7140 | Coagulation & Flocculation | 10mg/L |
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
|
Sodium Chlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| ZI-CHEM 2560 | Chlorine Dioxide Production | 28mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
Number of matching Manufacturers is 1
Number of matching Products is 17
Processing time was 0 seconds