NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsChemicals/Listings.asp?Company=C0426817&Standard=060&
NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| DrilRite-Chem LLC | |
| 702 Blackjack Street | |
| Winnsboro, TX 75494 | |
| United States | |
| 903-262-0078 | |
| Visit this company's website |
Facility : # 2 USA
|
Miscellaneous Chemical Products |
||
| Trade Designation | Product Function | Max Use |
| RiteMix | Coagulation & Flocculation | 1mg/L |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| PacRite-R/LV[1] | Well Drilling Aid | NA |
| RiteMix[1] | Well Drilling Aid | NA |
| SureFlow[1] [2] | Drilling Fluid | NA |
[1] This product is designed to be used off-line following manufacturer's use instructions.
The well is to be flushed until the turbidity of the water is < 1 NTU before the system
may be used for drinking water.
[2] Trade name may include numeric suffix corresponding to the quantity of fluid to which
the pre-measured packaged product is added.
|
||
Facility : Winnsboro, TX
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| ClayRite 100% | Well Drilling Aid | NA |
| DetRite 100% | Well Drilling Aid | NA |
| PacRite R/LV | Well Drilling Aid | NA |
| PolyRite[PC] | Well Drilling Aid | NA |
| SureFlow Clay[2] | Well Drilling Aid | NA |
| SureFlow Sand | Drilling Fluid | NA |
[1] These products are designed to be flushed out prior to using the system for drinking
water. Before being placed into service, the well is to be properly flushed according to
the manufacturer's use instructions. Certification of these products is based on the
well drilling model with the following assumptions:
- The amount of well drilling fluid used is 3780 L (1000 U.S. gallons) to which the
drilling fluid has been added at the manufacturer's recommended level.
- The aquifer contains 3.1 million liters of water (815,000 gallons) based on a 0.5
acre aquifer of 6.1 meter depth (20 ft.) and 25% porosity.
- The bore hole is 61 meters in total depth (200 ft.), the screen is 6.1 meters in
length (20 ft.), and the bore hole is 25.4 cm. in diameter (10 in.).
- The amount of well drilling fluid removed from the well during construction is equal
to the combined volumes of the casing and the screen, plus an additional amount
removed through the well disinfection and development (90% removed).
- This product should not be used in constructing wells in highly porous formations,
such as cavernous limestone.
[2] This product is designed to be used off-line following manufacturer's use instructions.
The well is to be flushed until the turbidity of the water is < 1 NTU before the system
may be used for drinking water.
[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
requirements for percent monomer and dose.
|
||
|
Polyacrylamide [PC] |
||
| Trade Designation | Product Function | Max Use |
| VisRite[1] | Well Drilling Aid | NA |
| VisRite | Coagulation & Flocculation | 1mg/L |
[1] These products are designed to be flushed out prior to using the system for drinking
water. Before being placed into service, the well is to be properly flushed according to
the manufacturer's use instructions. Certification of these products is based on the
well drilling model with the following assumptions:
- The amount of well drilling fluid used is 3780 L (1000 U.S. gallons) to which the
drilling fluid has been added at the manufacturer's recommended level.
- The aquifer contains 3.1 million liters of water (815,000 gallons) based on a 0.5
acre aquifer of 6.1 meter depth (20 ft.) and 25% porosity.
- The bore hole is 61 meters in total depth (200 ft.), the screen is 6.1 meters in
length (20 ft.), and the bore hole is 25.4 cm. in diameter (10 in.).
- The amount of well drilling fluid removed from the well during construction is equal
to the combined volumes of the casing and the screen, plus an additional amount
removed through the well disinfection and development (90% removed).
- This product should not be used in constructing wells in highly porous formations,
such as cavernous limestone.
[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
requirements for percent monomer and dose.
|
||
Number of matching Manufacturers is 1
Number of matching Products is 12
Processing time was 0 seconds