NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| Matrix Construction Products LLC | |
| 1760 Harbour View Drive | |
| Marquette, MI 49855 | |
| United States | |
| 877-591-3137 | |
| 630-730-7428 | |
| Visit this company's website |
Facility : Spring Lake, MI
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| FORTIFY® | Drilling Fluid | NA |
[1] These products are designed to be flushed out prior to using the system for drinking
water. Before being placed into service, the well is to be properly flushed according to
the manufacturer's use instructions. Certification of these products is based on the
well drilling model with the following assumptions:
- The amount of well drilling fluid used is 3780 L (1000 U.S. gallons) to which the
drilling fluid has been added at the manufacturer's recommended level.
- The aquifer contains 3.1 million liters of water (815,000 gallons) based on a 0.5 acre
aquifer of 6.1 meter depth (20 ft.) and 25% porosity.
- The bore hole is 61 meters in total depth (200 ft.), the screen is 6.1 meters in
length
(20 ft.), and the bore hole is 25.4 cm. in diameter (10 in.).
- The amount of well drilling fluid removed from the well during construction is equal
to
the combined volumes of the casing and the screen, plus an additional amount removed
through the well disinfection and development (90% removed).
- This product should not be used in constructing wells in highly porous formations,
such
as cavernous limestone.
|
||
|
Polyacrylamide[1] [PC] |
||
| Trade Designation | Product Function | Max Use |
| BIG-FOOT® | Well Drilling Aid | NA |
[1] These products are designed to be flushed out prior to using the system for drinking
water. Before being placed into service, the well is to be properly flushed according to
the manufacturer's use instructions. Certification of these products is based on the
well drilling model with the following assumptions:
- The amount of well drilling fluid used is 3780 L (1000 U.S. gallons) to which the
drilling fluid has been added at the manufacturer's recommended level.
- The aquifer contains 3.1 million liters of water (815,000 gallons) based on a 0.5 acre
aquifer of 6.1 meter depth (20 ft.) and 25% porosity.
- The bore hole is 61 meters in total depth (200 ft.), the screen is 6.1 meters in
length
(20 ft.), and the bore hole is 25.4 cm. in diameter (10 in.).
- The amount of well drilling fluid removed from the well during construction is equal
to
the combined volumes of the casing and the screen, plus an additional amount removed
through the well disinfection and development (90% removed).
- This product should not be used in constructing wells in highly porous formations,
such
as cavernous limestone.
[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
requirements for percent monomer and dose.
|
||