NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects



 
Kurita America Inc. 
6600 94th Avenue North
Minneapolis, MN 55445 
United States 
866-663-7633
Visit this company's website

Facility : # 1 USA


Miscellaneous Treatment Chemical
Trade Designation Product Function Max Use
Kuriverter™ AC-427[1] Dechlorination 8mg/L

[1] This product contains sulfite.
   Sulfites have been known to cause potentially lethal allergic reactions in sulfite-sensitive individuals.
   The maximum recommended allowable residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).

Miscellaneous Water Supply Products
Trade Designation Product Function Max Use
RoClean™ L211[2] Membrane Cleaner NA
RoClean™ L212 [2] [3] Membrane Cleaner NA
RoClean™ L403[2] Membrane Cleaner NA
RoClean™ L811[2] [3] Membrane Cleaner NA
RoClean™ P111[4] Membrane Cleaner NA
RoClean™ P112[2] [3] Membrane Cleaner NA
RoClean™ P303[2] [3] Membrane Cleaner NA
RoClean™ P903[4] Membrane Cleaner NA
Vitec™ 3000 Reverse Osmosis Antiscalant 7mg/L
Vitec™ 4000 Reverse Osmosis Antiscalant 7mg/L
Vitec™ 7000 Reverse Osmosis Antiscalant 7mg/L

[2] This product is designed to be used off-line and is to be flushed out prior to using the
    system for drinking water, following the manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
    of the product have been removed before placing into service.
[4] This product is designed to be used off-line and is to be flushed out prior to using the
    system for drinking water. The system should be flushed with 5 bed/volumes of water,
    before being placed back on-line.

Polymer Blends[PY]
Trade Designation Product Function Max Use
RoQuest™ 3000 Coagulation & Flocculation 125mg/L

[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
     percent monomer and dose.


Facility : GV USA


Miscellaneous Treatment Chemical
Trade Designation Product Function Max Use
Vitec™ 1070 Reverse Osmosis Antiscalant 5mg/L
Vitec™ 1141 Reverse Osmosis Antiscalant 30mg/L
Vitec™ 1200 Reverse Osmosis Antiscalant 24mg/L


Number of matching Manufacturers is 1
Number of matching Products is 16