NSF Product and Service Listings
These NSF Official Listings are current as of Tuesday, February 3, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsChemicals/Listings.asp?ProductFunction=Membrane+Cleaner&
NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| Accepta Co., Ltd. | |
| 38/195 Hathairat 39 | |
| Bangkok 10510 | |
| Thailand | |
| 66 25 389 002 |
Facility : Bangkok, Thailand
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| Hara NP200[2] [3] | Membrane Cleaner | NA |
| Hara RP2[2] [3] | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| ACURO ORGANICS LIMITED | |
| DSM 446-447 | |
| DLF Tower | |
| Najafgarh Road | |
| New Dehli, 110015 | |
| India | |
| 91 11 47479797 | |
| Visit this company's website |
Facility : Noida, Uttar Pradesh, India
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| ACUTHERM P102 | Membrane Cleaner pH Adjustment |
250mg/L |
| ALKIRO S40 | Membrane Cleaner pH Adjustment |
250mg/L |
| CAUSTIC SODA | Membrane Cleaner pH Adjustment |
250mg/L |
| RADIX P25 | Membrane Cleaner pH Adjustment |
250mg/L |
| RADIX pHB | Membrane Cleaner pH Adjustment |
250mg/L |
| pH PLUS | Membrane Cleaner pH Adjustment |
250mg/L |
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| ACUROCLEAN R21 | Membrane Cleaner | NA |
| CHEMICLEAN 21 | Membrane Cleaner | NA |
| Citric Acid | Membrane Cleaner | NA |
| Citric Acid Solution | Membrane Cleaner | NA |
| ROCLEAN 27 | Membrane Cleaner | NA |
| ROCLEAR 21 | Membrane Cleaner | NA |
| ROKLEEN 21 | Membrane Cleaner | NA |
| ROKLEEN 24P | Membrane Cleaner | NA |
| ROKLEEN 27 | Membrane Cleaner | NA |
| ROKLEEN 29P | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Advanced Biocatalytics Corporation | |
| 18010 Skypark Circle | |
| Suite 130 | |
| Irvine, CA 92614 | |
| United States | |
| 949-442-0880 | |
| Visit this company's website |
Facility : Macedonia, OH
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Accell3® | Reverse Osmosis Antiscalant Membrane Cleaner |
12mg/L |
| Accell® | Reverse Osmosis Antiscalant Membrane Cleaner |
34mg/L |
| Amaya Solutions, Inc. DBA American Water Chemicals | |
| 1802 Corporate Center Lane | |
| Plant City, FL 33563 | |
| United States | |
| 888-217-8757 | |
| 813-246-5448 | |
| Visit this company's website |
Facility : # 3 USA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Cleanflux Bio[2] | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
Facility : Plant City, FL
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| ALPHA C-234[2] [3] | Membrane Cleaner | NA |
| ALPHA C-236[2] [3] | Membrane Cleaner | NA |
| AWC C-203 | Membrane Cleaner | NA |
| AWC C-205[2] [3] | Membrane Cleaner | NA |
| AWC C-206[2] [3] | Membrane Cleaner | NA |
| AWC C-209[2] [3] | Membrane Cleaner | NA |
| AWC C-217[2] [3] | Membrane Cleaner | NA |
| AWC C-218[2] [3] | Membrane Cleaner | NA |
| AWC C-219[2] [3] | Membrane Cleaner | NA |
| AWC C-222[2] [3] | Membrane Cleaner | NA |
| AWC C-223[2] [3] | Membrane Cleaner | NA |
| AWC C-224[2] [3] | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| AWC C-225[2] [3] | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| AWC C-225N[2] [3] | Membrane Cleaner | NA |
| AWC C-226[2] [3] | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| AWC C-226LF[2] [3] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| AWC C-227[2] [3] | Membrane Cleaner | NA |
| AWC C-227LF[2] [3] | Membrane Cleaner | NA |
| AWC C-230[2] [3] | Membrane Cleaner | NA |
| AWC C-231[2] [3] | Membrane Cleaner | NA |
| AWC C-232[2] [3] | Membrane Cleaner | NA |
| AWC C-233[2] [3] | Membrane Cleaner | NA |
| AWC C-234[2] [3] | Membrane Cleaner | NA |
| AWC C-235[2] [3] | Membrane Cleaner | NA |
| AWC C-236[2] [3] | Membrane Cleaner | NA |
| AWC C-236LF[2] [3] | Membrane Cleaner | NA |
| AWC C-237[2] [3] | Membrane Cleaner | NA |
| AWC C-238[2] [3] | Membrane Cleaner | NA |
| AWC C-238[2] [3] | Membrane Cleaner | NA |
| AWC C-239[2] [3] | Membrane Cleaner | NA |
| AWC C-240[2] | Membrane Cleaner | NA |
| AWC C-241[2] [3] | Membrane Cleaner | NA |
| AWC C-245 | Membrane Cleaner | NA |
| AWC C-246[2] [3] | Membrane Cleaner | NA |
| AWC C-248 | Membrane Cleaner | NA |
| AWC C-249[2] [5] | Membrane Cleaner | NA |
| AWC C-266[2] [3] | Membrane Cleaner | NA |
| AWC C-437[2] [3] | Membrane Cleaner | NA |
| AWC UF-405[2] [3] | Membrane Cleaner | NA |
| AWC UF-406[2] [3] | Membrane Cleaner | NA |
| AWC UF-425[2] [3] | Membrane Cleaner | NA |
| AWC UF-426[2] [3] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| AWC UF-426LF | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| AWC UF-427[2] [3] | Membrane Cleaner | NA |
| AWC UF-427LF[2] [3] | Membrane Cleaner | NA |
| AWC UF-428[2] [3] | Membrane Cleaner | NA |
| AWC UF-428LF[2] [3] | Membrane Cleaner | NA |
| AWC UF-429[2] [3] | Membrane Cleaner | NA |
| AWC UF-429LF[2] [3] | Membrane Cleaner | NA |
| AWC UF-430[2] [3] | Membrane Cleaner | NA |
| AWC UF-431[2] [3] | Membrane Cleaner | NA |
| AWC UF-432[2] [3] | Membrane Cleaner | NA |
| AWC UF-433[2] [3] | Membrane Cleaner | NA |
| AWC UF-434[2] [3] | Membrane Cleaner | NA |
| AWC UF-437[2] [3] | Membrane Cleaner | NA |
| AWC UF-445 | Membrane Cleaner | NA |
| AWC UF-445 | Membrane Cleaner | NA |
| Cleanflux 2PF[2] [3] | Membrane Cleaner | N/A |
| Cleanflux BD | Membrane Cleaner | NA |
| Cleanflux Bio | Membrane Cleaner | N/A |
| Cleanflux L12[2] [3] | Membrane Cleaner | NA |
| Cleanflux LNP[2] [3] | Membrane Cleaner | NA |
| Cleanflux OR[2] | Membrane Cleaner | NA |
| Cleanflux SOX[2] | Membrane Cleaner | NA |
| G Water 05[2] [3] | Membrane Cleaner | NA |
| G Water 27[2] [3] | Membrane Cleaner | NA |
| Perasperse 15[2] | Membrane Cleaner Pipe Cleaning Aid |
NA |
| Pureflux 11P[2] [3] | Membrane Cleaner | NA |
| Pureflux 12L[2] [3] | Membrane Cleaner | NA |
| Pureflux 2L[2] [3] | Membrane Cleaner | NA |
| Pureflux 2P[2] [3] | Membrane Cleaner | NA |
[1] The product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
[2] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[4] This product is Certified for use as a reverse osmosis membrane preservative.
[5] The user should continue to flush until no more foaming is visible before placing into
service.
[6] This product functions as an off-line thermal distillation unit cleaner.
|
||
| Amaya Solutions, Inc. DBA American Water Chemicals | |
| 1802 Corporate Center Lane | |
| Plant City, FL 33563 | |
| United States | |
| 813-246-5448 | |
| Visit this company's website |
Facility : # 5 USA
|
Miscellaneous Treatment Chemical[CL] |
||
| Trade Designation | Product Function | Max Use |
| AWC D-307 | Reverse Osmosis Membrane Cleaner | 30mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| American Water Chemicals, Inc. | |
| 1802 Corporate Center Lane | |
| Plant City, FL 33563 | |
| United States | |
| 813-246-5448 | |
| Visit this company's website |
Facility : # 2 USA
|
Miscellaneous Water Supply Products[1] [2] [3] |
||
| Trade Designation | Product Function | Max Use |
| AWC D-605 | Membrane Cleaner | NA |
| AWC D-615P | Membrane Cleaner | NA |
[1] This products are designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[3] Drain and flush system until the hydrogen peroxide and peracetic acid concentrations
fall below 1 ppm.
|
||
Facility : # 6 USA
|
Miscellaneous Treatment Chemical[1] |
||
| Trade Designation | Product Function | Max Use |
| AWC D-615P | Membrane Cleaner Reverse Osmosis Antiscalant |
30mg/L |
[1] This product is designed to be used upstream of a carbon absorption system. Use of this
product shall be followed by chlorination to remove trace levels of hydrogen peroxide.
|
||
|
Miscellaneous Water Supply Products[2] [3] [4] |
||
| Trade Designation | Product Function | Max Use |
| AWC D-605 | Membrane Cleaner | NA |
[2] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[4] Drain and flush system until the hydrogen peroxide and peracetic acid concentrations
fall below 1 ppm.
|
||
| Analysys SAS | |
| 67 avenue de l'Europe | |
| ZI de Souillac | |
| 16200 Jarnac | |
| France | |
| 33 5 45 35 08 74 | |
| Visit this company's website |
Facility : Jarnac, France
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| ANALYFLOW RO 1132 A[1] | Membrane Cleaner | NA |
| ANALYFLOW RO 901 A[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Anco Chemicals Inc. | |
| 85 Malmo Court | |
| Maple, ON L6A 1R4 | |
| Canada | |
| 905-832-2276 | |
| Visit this company's website |
Facility : Maple, Ontario, Canada
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid | Membrane Cleaner | NA |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid 50% Solution | Membrane Cleaner | NA |
| Citric Acid Solution | Membrane Cleaner | NA |
[1] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Apex Water and Process, Inc. | |
| P.O. Box 550 | |
| Westfield, IN 46074 | |
| United States | |
| 317-867-4477 | |
| Visit this company's website |
Facility : Westfield, IN
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Hypura C20[1] | Membrane Cleaner | NA |
| Hypura C80[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions. The pH of the influent
and effluent water should be monitored to ensure that all traces of the product have
been removed before placing into service.
|
||
| AquaBlue Incorporated | |
| 1776 Tech Park Drive North East | |
| New Philadelphia, OH 44663 | |
| United States | |
| 330-343-0220 | |
| Visit this company's website |
Facility : # 1 USA
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| CA-50 | Membrane Cleaner | NA |
| Aquatech Systems (Asia) Pvt Ltd. | |
| Survey No 244/2, Rajiv Gandhi | |
| Infotech Park, Hinjewadi | |
| Pune, Maharashtra 411057 | |
| India | |
| 91 888 8826003 | |
| Visit this company's website |
Facility : Maharashtra, India
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| MEMGARD 6016 | Membrane Cleaner | NA |
| MEMGARD 6017 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Bell Chem / Safe Chem | |
| 1340 Bennett Drive | |
| Longwood, FL 32750 | |
| United States | |
| 407-339-2355 | |
| Visit this company's website |
Facility : # 4 USA
|
Miscellaneous Water Supply Products[2] [CL] |
||
| Trade Designation | Product Function | Max Use |
| Csan 2016 SuperOx | Membrane Cleaner Reverse Osmosis Membrane Biocide |
NA |
| Csan 2017 SuperOx WT | Membrane Cleaner Reverse Osmosis Membrane Biocide |
NA |
| Csan 2018 SuperOx II | Membrane Cleaner Reverse Osmosis Membrane Biocide |
NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Brainerd Chemical Company, Inc. | |
| 15 East 5th Street | |
| Tulsa, OK 74103 | |
| United States | |
| 800-551-5128 | |
| 918-622-1214 | |
| Visit this company's website |
Facility : Danville, IL
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% Solution | Membrane Cleaner Well Cleaning Aid |
NA |
| Citric Acid Solution | Membrane Cleaner Well Cleaning Aid |
NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Terrastat 15 | Membrane Cleaner Pipe Cleaning Aid |
NA |
| Terrastat 15 - OF | Membrane Cleaner Pipe Cleaning Aid |
NA |
| Terrastat 15 - S | Membrane Cleaner Pipe Cleaning Aid |
NA |
| Terrastat 22 | Membrane Cleaner Pipe Cleaning Aid |
NA |
| Terrastat 22 - S | Membrane Cleaner Pipe Cleaning Aid |
NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
[HY] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations. Also,
reference the AWWA B300 (Hypochlorites) standard's Recommendations for the Handling and
Storage of Hypochlorite Solutions appendix for information on preservation techniques
for hypochlorite bleach in transit and storage.
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified
Facility : Tulsa, OK
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% Solution | Well Cleaning Aid Membrane Cleaner |
NA |
| Citric Acid Solution | Well Cleaning Aid Membrane Cleaner |
NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions. The pH of the
influent and effluent water should be monitored to ensure that all traces of the product
have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Terrastat 15[1] | Membrane Cleaner Pipe Cleaning Aid |
NA |
| Terrastat 15 - OF[1] | Membrane Cleaner Pipe Cleaning Aid |
NA |
| Terrastat 15 - S[1] | Pipe Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Terrastat 22[1] | Pipe Cleaning Aid Membrane Cleaner |
NA |
| Terrastat 22 - S[1] | Reverse Osmosis Membrane Biocide Membrane Cleaner Pipe Cleaning Aid |
NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions. The pH of the
influent and effluent water should be monitored to ensure that all traces of the product
have been removed before placing into service.
|
||
NOTE: Only Listed products bearing the NSF Mark are considered NSF Certified.
| Brenntag Great Lakes LLC | |
| 4420 North Harley Davidson Avenue | |
| Wauwatosa, WI 53225 | |
| United States | |
| 262-252-3550 | |
| Visit this company's website |
Facility : Menomonee Falls, WI
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% Liquid | Membrane Cleaner Well Cleaning Aid |
NA |
| Citric Acid 50% Solution | Membrane Cleaner Well Cleaning Aid |
NA |
| Citric Acid Solution | Membrane Cleaner Well Cleaning Aid |
NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Brenntag Mid-South, Inc. | |
| 1405 Highway 136 West | |
| P.O. Box 20 | |
| Henderson, KY 42420-0020 | |
| United States | |
| 800-950-7267 | |
| 270-827-3545 | |
| Visit this company's website |
Facility : Tampa, FL
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid Solution | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions. The pH of the
influent and effluent water should be monitored to ensure that all traces of the product
have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Fairmont City, IL
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50%[1] [2] | Membrane Cleaner | NA |
| Citric Acid Solution[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 30-50%[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
Facility : Indianapolis, IN
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid Solution | Membrane Cleaner | NA |
| Citric Acid, Anhydrous | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, packing, and/or documentation shipped
with the product are Certified.
Facility : Henderson, KY
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid Solution | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions. The pH of the
influent and effluent water should be monitored to ensure that all traces of the product
have been removed before placing into service.
|
||
[CP] The finished drinking water shall be monitored to ensure that levels of copper do not
exceed 1.3 mg/L.
Facility : Chattanooga, TN
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid Solution | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed prior to using the system for
drinking water, following manufacturer's use
instructions. The pH of the influent and effluent water should be monitored to ensure
that all traces of the product have been removed before placing into service.
|
||
Facility : St. Louis, MO - Chouteau
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 30-50%[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Brenntag Pacific, LLC | |
| 10747 Patterson Place | |
| Santa Fe Springs, CA 90670 | |
| United States | |
| 323-562-9500 | |
| Visit this company's website |
Facility : Chandler, AZ
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50%[1] [2] | Membrane Cleaner | NA |
| Citric Acid Solution[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Fresno, CA
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid[1] [2] | Membrane Cleaner | NA |
| Citric Acid 20%[1] [2] | Membrane Cleaner | NA |
| Citric Acid 20% Solution[1] [2] | Membrane Cleaner | NA |
| Citric Acid 40%[1] [2] | Membrane Cleaner | NA |
| Citric Acid 40% Solution[1] [2] | Membrane Cleaner | NA |
| Citric Acid 50%[1] [2] | Membrane Cleaner | NA |
| Citric Acid 50% Solution[1] [2] | Membrane Cleaner | NA |
| Citric Acid Solution[1] [2] | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water shuold be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Richmond, CA
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50%[1] [2] | Membrane Cleaner | NA |
| Citric Acid Solution[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed prior to using the system for
drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : South Gate, CA
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid[4] [5] | Membrane Cleaner | NA |
| Citric Acid 50%[4] [5] | Membrane Cleaner | NA |
| Citric Acid Solution[4] [5] | Membrane Cleaner | NA |
[4] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[5] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Portland, OR
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50%[1] [2] | Membrane Cleaner | NA |
| Citric Acid Solution[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Cheyenne, WY
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50%[1] [2] | Membrane Cleaner | NA |
| Citric Acid Solution[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Brenntag Southwest, LLC | |
| 610 Fisher Road | |
| Longview, TX 75604 | |
| United States | |
| 800-722-3145 | |
| 918-273-2265 | |
| Visit this company's website |
Facility : Catoosa, OK
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% Solution | Membrane Cleaner | NA |
[1] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions
|
||
Facility : Houston, TX
|
Citric Acid[4] [5] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% Solution | Membrane Cleaner | NA |
[4] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[5] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Capacity Chemical LLC | |
| 8512 Hwy 33 | |
| Westley, CA 95387 | |
| United States | |
| (209) 231-3977 | |
| Visit this company's website |
Facility : Westley, CA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Clear Line 1500 | Membrane Cleaner | NA |
| Clear Line 200 | Membrane Cleaner | NA |
| Clear Line 2200 | Membrane Cleaner | NA |
| Clear Line 5600 | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
| Case Marine Inc. | |
| 18802 67th Avenue NorthEast | |
| Arlington, WA 98223 | |
| United States | |
| 206-352-8000 | |
| Visit this company's website |
Facility : # 1 USA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| CM-11[1] | Membrane Cleaner | NA |
| CM-22[1] [2] | Membrane Cleaner | NA |
| CM-88[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| CH2O, Inc. | |
| 8820 Old Highway 99 Southeast | |
| Olympia, WA 98501 | |
| United States | |
| 800-562-6184 | |
| 360-943-6063 |
Facility : #1 USA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Sani-Pac[1] | Membrane Cleaner Reverse Osmosis Antiscalant |
30mg/L |
[1] This product is designed to be used upstream of a carbon absorption system. Use of this
product shall be followed by chlorination to remove trace levels of hydrogen peroxide.
|
||
| ChampionX | |
| 11177 S. Stadium Dr. | |
| Sugar Land, TX 77478 | |
| United States | |
| 281-632-6500 |
Facility : #0106 USA
|
Miscellaneous Water Supply Products[2] |
||
| Trade Designation | Product Function | Max Use |
| MEMB00533A | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| ChampionX LLC | |
| 11177 South Stadium Drive | |
| Sugar Land, TX 77478 | |
| United States | |
| 281 632 8103 |
Facility : #107 USA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| MEMB00577A[1] [3] | Membrane Cleaner | N/A |
| MEMB00587A[1] | Membrane Cleaner | N/A |
| MEMB00596A[1] [2] | Membrane Cleaner | N/A |
| MEMB00598A[1] [2] | Membrane Cleaner | N/A |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[3] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #140 USA
|
Miscellaneous Water Supply Products[2] |
||
| Trade Designation | Product Function | Max Use |
| MEMB00533A | Membrane Cleaner | NA |
[2] These products are designed to be used off-line and flushed out prior to using the
system for drinking water. The pH of the influent and effluent water should be monitored
to ensure that all traces of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[3] |
||
| Trade Designation | Product Function | Max Use |
| MEMB00577A | Membrane Cleaner | NA |
[3] These products are designed to be used off-line and flushed out prior to using the system |
||
|
Miscellaneous Water Supply Products[2] |
||
| Trade Designation | Product Function | Max Use |
| MEMB00598A | Membrane Cleaner | NA |
[2] These products are designed to be used off-line and flushed out prior to using the
system for drinking water. The pH of the influent and effluent water should be monitored
to ensure that all traces of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Chemstream, Inc. | |
| 511 Railroad Avenue | |
| Homer City, PA 15748 | |
| United States | |
| 866-629-7118 | |
| 724-915-8388 | |
| Visit this company's website |
Facility : West Frankfort, IL
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| 50% Citric Acid[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
Facility : Stoystown, PA
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| 50% Citric Acid[2] | Membrane Cleaner Well Cleaning Aid |
NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
requirements for percent monomer and dose.
| Chemtrade Solutions LLC (formerly General Chemical LLC) | |
| 155 Gordon Baker Road | |
| Suite 300 | |
| Toronto, ON M2H 3N5 | |
| Canada | |
| 866-887-8805 | |
| 416-496-5856 | |
| Visit this company's website |
Facility : Odem, TX
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid Solution | Membrane Cleaner | NA |
| Genclean 704 | Membrane Cleaner | NA |
| Liquid Citric Acid | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| ChemTreat, Inc. | |
| 5640 Cox Road | |
| Glen Allen, VA 23060 | |
| United States | |
| 800-442-8292 | |
| 804-935-2311 | |
| Visit this company's website |
Facility : Eldridge, IA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| ChemTreat CL16[3] [4] | Membrane Cleaner | NA |
| ChemTreat CL416[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL100[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL1000[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL1500[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL1600 | Membrane Cleaner | NA |
| ChemTreat RL1700[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL2016[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL2017[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL3000[3] | Membrane Cleaner | NA |
| ChemTreat RL5000[3] [4] | Membrane Cleaner | NA |
| ChemTreat SS16[3] [4] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
[5] Certified for use as an off-line membrane cleaner. When used as an off-line membrane
cleaner, this product is designed to be flushed out prior to using the system for
drinking water. Follow manufacturer's use instructions.
NOTE: All Listed BL1240 is NSF Certified, whether or not it bears the NSF Mark.
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Nederland, TX
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| ChemTreat CL16[3] [4] | Membrane Cleaner | NA |
| ChemTreat CL416[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL100[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL1000[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL1500[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL1600 | Membrane Cleaner | NA |
| ChemTreat RL1700[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL1750[3] | Membrane Cleaner | NA |
| ChemTreat RL2016[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL2017[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL2032[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL3000[3] | Membrane Cleaner | NA |
| ChemTreat RL3400[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL5000[3] [4] | Membrane Cleaner | NA |
| ChemTreat SS16[3] [4] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
[5] Certified for use as an off-line membrane cleaner. When used as an off-line membrane
cleaner, this product is designed to be flushed out prior to using the system for
drinking water. Follow manufacturer's use instructions.
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
NOTE: All Listed BL1240 is NSF Certified, whether or not it bears the NSF Mark.
Facility : Ashland, VA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| ChemTreat CL16[3] [4] | Membrane Cleaner | NA |
| ChemTreat CL416[3] [4] | Membrane Cleaner | NA |
| ChemTreat R2050 | Membrane Cleaner | NA |
| ChemTreat RL100[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL1000[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL1500[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL1600 | Membrane Cleaner | NA |
| ChemTreat RL1700[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL1750[3] | Membrane Cleaner | NA |
| ChemTreat RL2016[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL2017[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL3000[3] | Membrane Cleaner | NA |
| ChemTreat RL3400[3] [4] | Membrane Cleaner | NA |
| ChemTreat RL5000[3] [4] | Membrane Cleaner | NA |
| ChemTreat SS16[3] [4] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
[5] Certified for use as an off-line membrane cleaner. When used as an off-line membrane
cleaner, this product is designed to be flushed out prior to using the system for
drinking water. Follow manufacturer's use instructions.
NOTE: All Listed BL1240 & BL1301 are NSF Certified, whether or not they bear the NSF Mark.
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| ChemTreat, Inc. | |
| 5640 Cox Road | |
| Glen Allen, VA 23060 | |
| United States | |
| 804-935-2000 |
Facility : # 14 USA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| CL-4580[1] [2] [3] | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[3] Drain and flush system until the hydrogen peroxide and peracetic acid concentrations
fall below 1 ppm.
|
||
Facility : # 21 USA
|
Miscellaneous Water Supply Products[2] |
||
| Trade Designation | Product Function | Max Use |
| CL4580 | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
Drain and flush system until the hydrogen peroxide and peracetic acid concentrations
fall below 1 ppm.
|
||
| Chemtron Supply Corporation dba Chemtron Riverbend | |
| 3500 Harry South Truman Boulevard | |
| St. Charles, MO 63301 | |
| United States | |
| 800-345-4399 | |
| 636-940-5445 | |
| Visit this company's website |
Facility : # 1 USA
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| RC9012 | Membrane Cleaner | NA |
| Clean H2O Technologies, LLC dba Crosstek | |
| 9651 Katy Freeway | |
| Suite 400 | |
| Houston, TX 77024 | |
| United States | |
| 832-304-7003 | |
| Visit this company's website |
Facility : USA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Xcerro HPH-1000[1] | Membrane Cleaner | NA |
| Xcerro LPH-1000[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| ClearTech Industries Inc. | |
| 1500 Quebec Avenue | |
| Saskatoon, SK S7K 1V7 | |
| Canada | |
| 306-664-2522 |
Facility : # 3 Edmonton, Alberta, Canada
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Aqueous Citric Acid 50%[2] [3] | Membrane Cleaner | NA |
| Citric Acid[2] [3] | Membrane Cleaner | NA |
| Citric Acid 50% Solution[2] [3] | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] CITRIC ACID ANHYDROUS and CITRIC ACID GRANULAR are Certified for use as filter media
cleaners.
|
||
| COFCO Biochemical (Thailand) Co., Ltd. | |
| 184/8, 11th Floor, Building Forum Tower | |
| Ratchadaphisek Road, HuaiKhwan | |
| Bangkok 10310 | |
| Thailand | |
| 66 26 454 051 |
Facility : Rayong, Thailand
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid Anhydrous Fine Granular[1] | Membrane Cleaner Well Cleaning Aid |
NA |
| Citric Acid Anhydrous Granular[1] | Membrane Cleaner Well Cleaning Aid |
NA |
| Citric Acid monohydrate | Membrane Cleaner Well Cleaning Aid |
NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Consolidated Water Solutions | |
| 10100 J Street | |
| Omaha, NE 68127 | |
| United States | |
| 800-852-1150 | |
| 402-697-7800 | |
| Visit this company's website |
Facility : Omaha, NE
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| CC010[1] [2] | Membrane Cleaner | NA |
| CC012[1] [2] | Membrane Cleaner | NA |
| CC016[1] [2] | Membrane Cleaner | NA |
| CC019[1] [2] | Membrane Cleaner | NA |
| CC217[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Crest Water Pte Ltd | |
| 100 Peck Seah Street | |
| #08-14. PS100. | |
| Singapore 079333 | |
| Singapore | |
| 65 9631 1867 | |
| Visit this company's website |
Facility : # 1 China
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| CrestoPro R800 [1] | Membrane Cleaner | NA |
| CrestoPro R820[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions. The pH of the
influent and effluent water should be monitored to ensure that all traces of the product
have been removed before placing into service.
[2] This product is to be added to the feedwater of evaporator type units.
|
||
| DAFFODIL PHARMACHEM PRIVATE LIMITED | |
| A-2304, Privilon, 23rd Floor, B/H Iskcon | |
| Temple, Ambli-Bopal Road, S.G Highway | |
| Ahmedabad, Gujarat 380054 | |
| India | |
| 91 79 26449966 | |
| Visit this company's website |
Facility : # 1 India
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid Anhydrous | Membrane Cleaner | NA |
| Citric Acid Monohydrate | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Sodium Citrate | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| DuBois Chemicals, Inc. | |
| 3630 East Kemper Road | |
| Sharonville, OH 45241 | |
| United States | |
| 800-438-2647 | |
| Visit this company's website |
Facility : Cincinnati, OH
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| RO-2010 | Membrane Cleaner | NA |
| DuPont Water Solutions | |
| 200 Powder Mill Road | |
| Wilmington, DE 19803 | |
| United States | |
| 800-MEMCOR4 | |
| 978-863-4600 | |
| Visit this company's website |
Facility : Los Angeles, CA
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| MEMCLEAN® C | Membrane Cleaner | NA |
| MEMCLEAN® EXA2 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH and conductivity of the influent and effluent water should be monitored to ensure
that all traces of the product have been removed before placing into service.
|
||
| Eagle Labs, Inc. | |
| 1318 Marilyn Street | |
| P.O. Box 645 | |
| Desoto, TX 75123 | |
| United States | |
| 972-274-1690 |
Facility : Desoto, TX
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citra Kleen | Membrane Cleaner | NA |
| DScale | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Eflo-Chem Chemicals Blending Co. | ![]() |
| Al-Quoz Industrial Area #3 | |
| P.O. Box 12282 | |
| Dubai | |
| United Arab Emirates | |
| 971 4 347 2900 | |
| Visit this company's website |
Facility : Dubai, United Arab Emirates
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| EC-ROC-6 | Membrane Cleaner | NA |
| EC-ROC-8 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Envirocleen, LLC | |
| 872 South Milwaukee Avenue | |
| Suite 245 | |
| Libertyville, IL 60048 | |
| United States | |
| 847-892-4141 | |
| Visit this company's website |
Facility : # 1 USA
|
Miscellaneous Water Supply Products[2] [CL] |
||
| Trade Designation | Product Function | Max Use |
| BIO-HYDROX | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| BIO-HYDROX OXIDATION CATALYST | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| BIOHYDROX AGRO | Membrane Cleaner Reverse Osmosis Membrane Biocide Well Cleaning Aid |
NA |
| BIOHYDROX AQUATIC | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| BIOHYDROX BIOFILM REMOVER | Membrane Cleaner Reverse Osmosis Membrane Biocide Well Cleaning Aid |
NA |
| BIOHYDROX LEGIONELLA BIOCIDE | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| BX-9430 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| BX-9431 | Membrane Cleaner Reverse Osmosis Membrane Biocide Well Cleaning Aid |
NA |
| BX-9465 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| BX-9466 | Membrane Cleaner Reverse Osmosis Membrane Biocide Well Cleaning Aid |
NA |
| BX-9475 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| BX-9476 | Membrane Cleaner Reverse Osmosis Membrane Biocide Well Cleaning Aid |
NA |
| ROS-9000 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| ROS-9430 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| ROS-9431 | Membrane Cleaner Reverse Osmosis Membrane Biocide Well Cleaning Aid |
NA |
| ROS-9432 | Membrane Cleaner Reverse Osmosis Membrane Biocide Well Cleaning Aid |
NA |
| ROS-9432 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| ROS-9433 | Membrane Cleaner Reverse Osmosis Membrane Biocide Well Cleaning Aid |
NA |
| ROS-9450 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| ROS-9451 | Membrane Cleaner Reverse Osmosis Membrane Biocide Well Cleaning Aid |
NA |
| ROS-9452 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| ROS-9453 | Membrane Cleaner Reverse Osmosis Membrane Biocide Well Cleaning Aid |
NA |
| ROS-9465 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| ROS-9466 | Membrane Cleaner Reverse Osmosis Membrane Biocide Well Cleaning Aid |
NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| EnviroTech Chemical Services, Inc. | |
| 500 Winmoore Way | |
| Modesto, CA 95358 | |
| United States | |
| 888-563-2254 | |
| 209-581-9576 | |
| Visit this company's website |
Facility : Helena, AR
|
Miscellaneous Water Supply Products[1] [2] [3] |
||
| Trade Designation | Product Function | Max Use |
| Bioside HS 15% | Membrane Cleaner | NA |
| BromMax 7.1 | Membrane Cleaner | NA |
| Perasan A | Membrane Cleaner | NA |
| REFLEX™ | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[3] Drain and flush system until hydrogen peroxide and peracetic acid concentrations fall
below 1 ppm.
|
||
Facility : Modesto, CA
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| Bioside HS 15%[2] | Membrane Cleaner Reverse Osmosis Antiscalant |
30mg/L |
[2] This product is designed to be used upstream of a carbon absorption system. Use of this
product shall be followed by chlorination to remove trace levels of hydrogen peroxide.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Perasan A[3] [4] [5] | Membrane Cleaner | NA |
| REFLEX™[3] [4] [5] | Membrane Cleaner | NA |
[1] ECO 9000 is used offline to remove deposits from water tank surfaces. It is used in a
10:1 ratio at a rate of 60 mg/L with Hydrogen Peroxide 34%. The tank is rinsed to
remove any residual product before returning to service.
[3] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[5] Drain and flush system until the hydrogen peroxide and peracetic acid concentrations
fall below 1 ppm.
|
||
| Equipos Y Productos Químicos Del Noroeste S.A. de C.V. (CLARVI) | ![]() |
| Alfonso Cano 516 Ote., Fracc. El Parque | |
| Los Mochis, Sinaloa 81259 | |
| Mexico | |
| 52 668 812 8899 | |
| Visit this company's website |
Facility : Los Mochis, Sinaloa, Mexico
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| RO PROTECH CH[3] [4] | Membrane Cleaner | NA |
| RO PROTECH CL[3] [4] | Membrane Cleaner | NA |
[2] This product is certified for use as a disinfectant and as an oxidizer.
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
| Evonik Active Oxygens, LLC | |
| 2 Turner Place | |
| Piscataway, NJ 08854 | |
| United States | |
| (732) 981-5000 | |
| Visit this company's website |
Facility : Tonawanda, NY
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| PERACLEAN VANGUARD[1] | Membrane Cleaner | NA |
| VigorOx WWT II[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Pocola, OK
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| PERACLEAN VANGUARD | Membrane Cleaner | NA |
| VIGOROX WWT II | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Memphis, TN
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| PERACLEAN VANGUARD[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Garratt-Callahan Company | |
| 50 Ingold Drive | |
| Burlingame, CA 94010-2206 | |
| United States | |
| 650-697-5811 | |
| Visit this company's website |
Facility : Burlingame, CA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Formula 9033[4] | Membrane Cleaner | NA |
| Formula 9067[4] | Membrane Cleaner | NA |
| Formula 9098[4] [5] | Membrane Cleaner Pipe Cleaning Aid |
NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
Drain and flush system until the hydrogen peroxide and peracetic acid concentrations
fall below 1 ppm.
[4] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[5] This product functions as an offline scale remover for the water distribution system,
parts, vessels and devices.
[6] This product is designed to reduce biofilms and help prevent the scaling and calcium
build-up on walls, piping systems and membrane surfaces of drinking water systems.
|
||
Facility : Atlanta, GA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Formula 9033[4] [5] | Membrane Cleaner | NA |
| Formula 9067[4] [5] | Membrane Cleaner | NA |
| Formula 9098[4] [5] [6] | Membrane Cleaner Pipe Cleaning Aid |
NA |
[3] Drain and flush system until the hydrogen peroxide and peracetic acid concentrations
fall below 1 ppm.
[4] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[5] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[6] This product functions as an offline scale remover for the water distribution system,
parts, vessels and devices.
[7] This product is designed to reduce biofilms and help prevent the scaling and calcium
build-up on walls, piping systems and membrane surfaces of drinking water systems.
|
||
Facility : Addison, IL
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Formula 9033[4] [5] | Membrane Cleaner | NA |
| Formula 9067[4] [5] | Membrane Cleaner | NA |
| Formula 9098[4] [5] [6] | Membrane Cleaner Pipe Cleaning Aid |
NA |
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
Drain and flush system until the hydrogen peroxide and peracetic acid concentrations
fall below 1 ppm.
[4] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[5] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[6] This product functions as an offline scale remover for the water distribution system,
parts, vessels and devices.
[7] This product is designed to reduce biofilms and help prevent the scaling and calcium
build-up on walls, piping systems and membrane surfaces of drinking water systems.
|
||
Facility : Farmers Branch, TX
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Formula 9033[4] [5] | Membrane Cleaner | NA |
| Formula 9067[4] [5] | Membrane Cleaner | NA |
| Formula 9098[4] [5] [6] | Membrane Cleaner Pipe Cleaning Aid |
NA |
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
Drain and flush system until the hydrogen peroxide and peracetic acid concentrations
fall below 1 ppm.
[4] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[5] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[6] This product functions as an offline scale remover for the water distribution system,
parts, vessels and devices.
[7] This product is designed to reduce biofilms and help prevent the scaling and calcium
build-up on walls, piping systems and membrane surfaces of drinking water systems.
|
||
| Genesys International Ltd. | ![]() |
| 3A Aston Way | |
| Midpoint 18 | |
| Middlewich, Cheshire CW10 0HS | |
| United Kingdom | |
| 44 1606 837605 | |
| Visit this company's website |
Facility : Cheshire, United Kingdom
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Genesol 38[1] [2] | Membrane Cleaner | NA |
| Genesol 40[1] [2] | Membrane Cleaner | NA |
| Genesol 61[1] | Membrane Cleaner | NA |
| Genesol 701[1] [2] | Membrane Cleaner | NA |
| Genesol 703[1] [2] | Membrane Cleaner | NA |
| Genesol 704[1] [2] | Membrane Cleaner | NA |
| Genesol 711[1] [2] | Membrane Cleaner | NA |
| Genesol 721[1] [2] | Membrane Cleaner | NA |
| Genesol 734[1] [2] | Membrane Cleaner | NA |
| Genesol 764[1] [2] | Membrane Cleaner | NA |
| Genesol 80[1] | Membrane Cleaner | NA |
| Genesol UF Fe[1] [2] | Membrane Cleaner | NA |
| Genesol UF12[1] [2] | Membrane Cleaner | NA |
| Genesol UF2[1] [2] | Membrane Cleaner | NA |
| Genesol UF7[1] [2] | Membrane Cleaner | NA |
| Genesol UF8[1] | Membrane Cleaner | NA |
| Lavasol 80[1] | Membrane Cleaner | NA |
| Lavasol™ 7[1] | Membrane Cleaner | NA |
| OptiClean A+[1] [2] | Membrane Cleaner | NA |
| OptiClean B+[1] [2] | Membrane Cleaner | NA |
| OptiClean G+[1] [2] | Membrane Cleaner | NA |
| OptiClean N+[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
Facility : Rossendale, Lancs, United Kingdom
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Genesol 38[1] | Membrane Cleaner | NA |
| Genesol 701[1] | Membrane Cleaner | NA |
| Genesol 703[1] | Membrane Cleaner | NA |
| Genesol 704[1] | Membrane Cleaner | NA |
| Genesol 711[1] | Membrane Cleaner | NA |
| Genesol 721[1] | Membrane Cleaner | NA |
| Genesol 734[1] | Membrane Cleaner | NA |
| Genesol 764[1] | Membrane Cleaner | NA |
| Genesol UF12 | Membrane Cleaner | NA |
| Genesol UF2[1] | Membrane Cleaner | NA |
| Opticlean A+[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| George S. Coyne Chemical Co., Inc. | |
| 3015 State Road | |
| Croydon, PA 19021 | |
| United States | |
| 800-523-1230 | |
| 215-785-3000 | |
| Visit this company's website |
Facility : Croydon, PA
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| CMC 150[2] [3] | Membrane Cleaner | NA |
| Citric Acid Anhydrous | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Global Chemicals Corporation | |
| 1 Corporate Place South | |
| Piscataway, NJ 08854 | |
| United States | |
| (732) 369-9300 | |
| Visit this company's website |
Facility : East Brunswick, NJ
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% Solution | Well Cleaning Aid Membrane Cleaner |
NA |
| Arco Organics Citric Acid Solution | Well Cleaning Aid Membrane Cleaner |
NA |
| Citric Acid Anhydrous | Well Cleaning Aid Membrane Cleaner |
NA |
| Arco Organics Citric Acid Anhydrous | Well Cleaning Aid Membrane Cleaner |
NA |
| Arco Organics 50% Citric Acid Solution | Well Cleaning Aid Membrane Cleaner |
NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| GRADIANT INDUSTRIES - L.L.C - S.P.C | ![]() |
| 124, M33 Mussafah Industrial Area | |
| P.O. Box 72583 | |
| Abu Dhabi | |
| United Arab Emirates | |
| 971 2 6445478 | |
| Visit this company's website |
Facility : Abu Dhabi, United Arab Emirates
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| CURE 9540[3] | Membrane Cleaner | N/AN/A |
| CURE 9548[3] | Membrane Cleaner | N/AN/A |
| CURE 9550[3] | Membrane Cleaner | N/AN/A |
| CURE 9557[3] | Membrane Cleaner | N/AN/A |
| CURE 9558[3] | Membrane Cleaner | N/AN/A |
[1] Certified for addition to the feedwater for evaporative desalination units only.
[3] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
|
||
| H2O Inc. | |
| 841 Vincent Road | |
| Lafayette, LA 70508 | |
| United States | |
| 337-857-7203 |
Facility : Vista, CA
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Cubeclean A | Membrane Cleaner | NA |
| Cubeclean D | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Harcros Chemicals Inc. | |
| 5200 Speaker Road | |
| Kansas City, KS 66106 | |
| United States | |
| 913-321-3131 | |
| Visit this company's website |
Facility : Tampa, FL
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| HARCROS AQUACROS MC | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Vicksburg, MS
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | N/A |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Has Holdings Pty Ltd. | |
| Suite 12, Kwinana Tech Business Ctr | |
| 11, Stidworthy Way, Kwinana Town Ctr | |
| Western Australia 6167 | |
| Australia | |
| 61 411 249 695 | |
| Visit this company's website |
Facility : # 11 USA
|
Miscellaneous Water Supply Products[2] [CL] |
||
| Trade Designation | Product Function | Max Use |
| Ariceo BR 9256 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo BR 9256P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9230 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9230P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9250 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9250P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9265 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9265P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9275 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9275P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9330 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9330P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9350 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9350P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9365 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo CA 9365P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo RO 9731 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo RO 9731P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo RO 9751 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo RO 9751P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo RO 9831 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo RO 9831P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo RO 9851 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo RO 9851P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo ZR 9192 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Ariceo ZR 9192P | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Hasa Inc. | |
| 23119 Drayton Street | |
| Saugus, CA 91350 | |
| United States | |
| 925-432-3866 | |
| Visit this company's website |
Facility : Greenville, TX
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Hawkins, Inc. | |
| 2381 Rosegate | |
| Roseville, MN 55113 | |
| United States | |
| 800-328-5460 | |
| 612-331-6910 | |
| Visit this company's website |
Facility : # 2 Centralia, IL
|
Citric Acid[2] [3] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 15% Solution FCC | Membrane Cleaner | NA |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid 50% FCC | Membrane Cleaner | NA |
| Citric Acid 50% FG | Membrane Cleaner | NA |
| Citric Acid 50% Technical | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #2 Rosemount, MN
|
Hydrochloric Acid |
||
| Trade Designation | Product Function | Max Use |
| Hydrochloric Acid 10%[1] | Membrane Cleaner | NA |
| Hydrochloric Acid 10% FCC[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
Facility : Apopka, FL
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 15% Solution FCC | Membrane Cleaner | NA |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid 50% FCC | Membrane Cleaner | NA |
| Citric Acid 50% FG | Membrane Cleaner | NA |
| Citric Acid 50% Technical | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all
traces of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Sulphur, LA
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 15% Solution FCC | Membrane Cleaner | NA |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid 50% FCC | Membrane Cleaner | NA |
| Citric Acid 50% FG | Membrane Cleaner | NA |
| Citric Acid 50% Technical | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
[CP] The finished drinking water shall be monitored to ensure that levels of copper do not
exceed 1.3 mg/L.
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Minneapolis, MN
|
Citric Acid[3] [4] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 15% Solution FCC | Membrane Cleaner | NA |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid 50% FCC | Membrane Cleaner | NA |
| Citric Acid 50% FG | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Hydrochloric Acid |
||
| Trade Designation | Product Function | Max Use |
| Hydrochloric Acid 10%[3] | Membrane Cleaner | NA |
| Hydrochloric Acid 10% FCC[3] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
[CP] The finished drinking water shall be monitored to ensure that levels of copper do not
exceed 1.3 mg/L.
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Fayetteville, TN
|
Citric Acid[2] [3] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 15% Solution FCC | Membrane Cleaner | NA |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid 50% FCC | Membrane Cleaner | NA |
| Citric Acid 50% FG | Membrane Cleaner | NA |
| Citric Acid 50% Technical | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Luling, TX
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 15% Solution FCC | Membrane Cleaner | NA |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid 50% FCC | Membrane Cleaner | NA |
| Citric Acid 50% FG | Membrane Cleaner | NA |
| Citric Acid 50% Technical | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
[CP] The finished drinking water shall be monitored to ensure that levels of copper do not
exceed 1.3 mg/L.
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Luling, TX
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 15% Solution FCC[4] | Membrane Cleaner | NA |
| Citric Acid 50%[4] | Membrane Cleaner | NA |
| Citric Acid 50% FCC[4] | Membrane Cleaner | NA |
| Citric Acid 50% FG[4] | Membrane Cleaner | NA |
| Citric Acid 50% Technical[4] | Membrane Cleaner | NA |
[4] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions. The pH of the influent
and effluent water should be monitored to ensure that all traces of the product have
been removed before placing into service.
|
||
Facility : Spring, TX
|
Citric Acid[2] [3] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid | Membrane Cleaner | NA |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid 50% Technical | Membrane Cleaner | NA |
| NAPCO Citric Acid | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
[CP] The finished drinking water shall be monitored to ensure that levels of copper do not
exceed 1.3 mg/L.
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| IBWT (Qingdao) Industrial Water Treatment Co., Ltd. | |
| Jiaozhou Economic and | |
| Technological Development Zone | |
| Qingdao, Shandong 266318 | |
| China | |
| 86 136 5623 3742 |
Facility : Tai'an, Shandong, China
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| IBWT MajorClean 810[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| IBWT MajorClean 910[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| International Aquatreat Co. BVBA | |
| Industriezone B122 | |
| Nieuwlandlaan 40/42 | |
| Aarschot 3200 | |
| Belgium | |
| 32 16 562 121 | |
| Visit this company's website |
Facility : Aarschot, Belgium
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| AQUATREAT 858[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Italmatch Chemicals GB Ltd. | |
| Ashburton Road West | |
| Manchester | |
| M17 1SX | |
| United Kingdom | |
| 44 161 864 6699 |
Facility : # 4 United Kingdom
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| FLOCON MC561[1] [2] | Membrane Cleaner | NA |
| FLOCON MC67[1] [2] | Membrane Cleaner | NA |
| FLOCON MC68[1] [2] | Membrane Cleaner | NA |
| SPE 0560[1] [2] | Membrane Cleaner | NA |
| SPE 0561 [1] [2] | Membrane Cleaner | NA |
| SPE 0569 | Membrane Cleaner | NA |
| SPE0567[1] [2] | Membrane Cleaner | NA |
| SPE0568[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Italmatch Chemicals S.p.A. | |
| Via Magazzini del Cotone 17 - Modulo 4 | |
| 16128 Genova | |
| Italy | |
| 39 010 64 20 81 | |
| Visit this company's website |
Facility : # 1 United Kingdom
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| SPE 0560 | Membrane Cleaner | NA |
| SPE 0561 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Italmatch USA Corporation | |
| 5544 Oakdale Road, Southeast | |
| Smyrna, GA 30082 | |
| United States | |
| 888-962-6296 | |
| 787-601-5304 | |
| Visit this company's website |
Facility : Birmingham, AL
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| SPE 0562 | Membrane Cleaner | N/A |
| SPE 0563 | Membrane Cleaner | N/A |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| JAS Global Industries | |
| Al Sulay Mashael Rams Industrial Area | |
| Al Abbasia Street Block No 9 &10 | |
| Riyadh 220765 | |
| Saudi Arabia | |
| 971 4 442 4795 |
Facility : Riyadh, Saudi Arabia
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| UltraClean 219[2] | Membrane Cleaner | N/A |
| UltraClean 220[2] | Membrane Cleaner | N/A |
| UltraClean 221[2] | Membrane Cleaner | N/A |
| UltraClean 312[2] | Membrane Cleaner | N/A |
| UltraClean 313[2] | Membrane Cleaner | N/A |
| UltraClean 314[2] | Membrane Cleaner | N/A |
| UltraClean 3434[2] | Membrane Cleaner | N/A |
| UltraClean 41[2] | Membrane Cleaner | N/A |
| UltraClean 42[2] | Membrane Cleaner | N/A |
| UltraClean 43[2] | Membrane Cleaner | N/A |
| UltraClean 4545[2] | Membrane Cleaner | N/A |
| UltraClean W87[2] | Membrane Cleaner | N/A |
| UltraClean W88[2] | Membrane Cleaner | N/A |
| UltraClean W89[2] | Membrane Cleaner | N/A |
[1] Certified for addition to the feedwater for evaporative desalination units only.
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Jay Chemical Industries Private LImited | |
| Jay House, Panchvati Circle, Ambawadi | |
| AHMEDABAD, GJ 380006 | |
| India | |
| +91 9909908169 | |
| Visit this company's website |
Facility : Gujarat, India
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| AKWA RC 5022 | Membrane Cleaner | NA |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| AKWA RC 5012[2] | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| JENFITCH, INC. | |
| 712 Bancroft Road | |
| Suite 805 | |
| Walnut Creek, CA 94598 | |
| United States | |
| 800-644-3518 | |
| 925-289-3559 | |
| Visit this company's website |
Facility : #4 USA
|
Miscellaneous Water Supply Products[2] [CL] |
||
| Trade Designation | Product Function | Max Use |
| JC 9430 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| JC 9430 ROS | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| JC 9450 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| JC 9450 BIOFILM REMOVER | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| JC 9450 ROS | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| JC 9465 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| JC 9475 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| TC 9430 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| TC 9430 ROS | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| TC 9450 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| TC 9450 ROS | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| TC 9465 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Z-REMOVAL2 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
Facility : # 5 USA
|
Miscellaneous Water Supply Products[2] [CL] |
||
| Trade Designation | Product Function | Max Use |
| JC 9430 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| JC 9430 ROS | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| JC 9450 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| JC 9450 BIOFILM REMOVER | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| JC 9450 ROS | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| JC 9465 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| JC 9475 | Well Cleaning Aid Membrane Cleaner Reverse Osmosis Membrane Biocide |
NA |
| TC 9430 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| TC 9430 ROS | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| TC 9450 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| TC 9450 ROS | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
| Z-REMOVAL2 | Well Cleaning Aid Reverse Osmosis Membrane Biocide Membrane Cleaner |
NA |
[2] This product is designed to be used off-line and flushed put prior to using the system
for drinking water, following manufacturer's use instructions.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Justeq, LLC | |
| 1866 Windridge Drive | |
| Lake Forest, IL 60045 | |
| United States | |
| 202-607-7964 |
Facility : Fontana, CA
|
Miscellaneous Treatment Chemical[CL] |
||
| Trade Designation | Product Function | Max Use |
| CL 4917 | Reverse Osmosis Membrane Cleaner | 30mg/L |
| Hydrex 7958 | Reverse Osmosis Membrane Cleaner | 30mg/L |
| Justeq07 | Reverse Osmosis Membrane Cleaner | 30mg/L |
| MD 100 | Reverse Osmosis Membrane Cleaner | 30mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
Facility : Milwaukee, WI
|
Miscellaneous Treatment Chemical[CL] |
||
| Trade Designation | Product Function | Max Use |
| CL 4917 | Reverse Osmosis Membrane Cleaner | 30mg/L |
| Hydrex 7958 | Reverse Osmosis Membrane Cleaner | 30mg/L |
| Justeq07 | Reverse Osmosis Membrane Cleaner | 30mg/L |
| MD 100 | Reverse Osmosis Membrane Cleaner | 30mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Jutzi Water Technologies | |
| 525 Wright Boulevard | |
| Stratford, ON N4A 6T1 | |
| Canada | |
| 519-814-9283 | |
| Visit this company's website |
Facility : Stratford, Ontario, Canada
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | N/A |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| King Lee Technologies | |
| 8949 Kenamar Drive #107 | |
| San Diego, CA 92121 | |
| United States | |
| 858-693-4062 | |
| Visit this company's website |
Facility : # 1 USA
|
Miscellaneous Water Supply Products NOTE: |
||
| Trade Designation | Product Function | Max Use |
| Diamite HpHNOTE: | Membrane Cleaner | NAmg/L |
| Diamite LpHNOTE: | Membrane Cleaner | NAmg/L |
| Diamite SilicaNOTE: | Membrane Cleaner | NAmg/L |
NOTE: This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
NOTE: This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Klearwater Equipment and Technologies Corp. | |
| 46 Masters Avenue SE | |
| Calgary, AB T3M 2B1 | |
| Canada | |
| 888-696-6561 | |
| 403-254-4240 | |
| Visit this company's website |
Facility : # 1 Canada
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | NA |
| Kurita America Inc. | |
| 6600 94th Avenue North | |
| Minneapolis, MN 55445 | |
| United States | |
| 866-663-7632 | |
| 763-689-3636 | |
| Visit this company's website |
Facility : CB USA
|
Miscellaneous Chemical Products |
||
| Trade Designation | Product Function | Max Use |
| ROC 50 N[1] | Membrane Cleaner | NA |
[1] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| AvistaClean™ L0381[1] [2] | Membrane Cleaner | NA |
| AvistaClean™ L1181[2] | Membrane Cleaner | NA |
| AvistaClean™ L1211 | Membrane Cleaner | NA |
| AvistaClean™ L1221[1] [2] | Membrane Cleaner | NA |
| Avista™ RC L112 | Membrane Cleaner | NA |
| Avista™ RC L211[1] [2] | Membrane Cleaner | NA |
| Avista™ RC L212[1] [2] | Membrane Cleaner | NA |
| Avista™ RC L403[1] [2] | Membrane Cleaner | NA |
| Avista™ RC L811[2] | Membrane Cleaner | NA |
| Avista™177[1] [2] | Membrane Cleaner | NA |
| Avista™181[1] [2] | Membrane Cleaner | NA |
| ROC 20 N[1] [2] | Membrane Cleaner | NA |
| RoClean™ L102[1] [2] | Membrane Cleaner | NA |
| RoClean™ L112 | Membrane Cleaner | NA |
| RoClean™ L211[1] [2] | Membrane Cleaner | NA |
| RoClean™ L212[1] [2] | Membrane Cleaner | NA |
| RoClean™ L403[1] [2] | Membrane Cleaner | NA |
| RoClean™ L811[2] | Membrane Cleaner | NA |
[1] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
Facility : FW USA
|
Miscellaneous Chemical Products |
||
| Trade Designation | Product Function | Max Use |
| AvistaClean™ P0327 | Membrane Cleaner | NA |
| AvistaClean™ P1219 | Membrane Cleaner | NA |
| AvistaClean™ P611 | Membrane Cleaner | NA |
| AvistaClean™MF 3000 | Membrane Cleaner | NA |
| Avista™ 127 | Membrane Cleaner | NA |
| Avista™ 146 | Membrane Cleaner | NA |
| Avista™ 192 | Membrane Cleaner | NA |
| Avista™ 199 | Membrane Cleaner | NA |
| Avista™ RC P111 | Membrane Cleaner | NA |
| Avista™ RC P112 | Membrane Cleaner | NA |
| Avista™ RC P192 | Membrane Cleaner | NA |
| Avista™ RC P303 | Membrane Cleaner | NA |
| Avista™ RC P611 | Membrane Cleaner | NA |
| Avista™ RC P903 | Membrane Cleaner | NA |
| RoClean™ P111 | Membrane Cleaner | NA |
| RoClean™ P112 | Membrane Cleaner | NA |
| RoClean™ P192 | Membrane Cleaner | NA |
| RoClean™ P303 | Membrane Cleaner | NA |
| RoClean™ P611 | Membrane Cleaner | NA |
| RoClean™ P903 | Membrane Cleaner | NA |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| AvistaClean™ L0381 | Membrane Cleaner | NA |
| AvistaClean™ L1181 | Membrane Cleaner | NA |
| AvistaClean™ L1211 | Membrane Cleaner | NA |
| AvistaClean™ L1221 | Membrane Cleaner | NA |
| Avista™ RC L112 | Membrane Cleaner | NA |
| Avista™ RC L211 | Membrane Cleaner | NA |
| Avista™ RC L212 | Membrane Cleaner | NA |
| Avista™ RC L403 | Membrane Cleaner | NA |
| Avista™ RC L811 | Membrane Cleaner | NA |
| Avista™177 | Membrane Cleaner | NA |
| Avista™181 | Membrane Cleaner | NA |
| Kuriverter™ IK-110M | Membrane Cleaner | NA |
| ROC 20 N | Membrane Cleaner | NA |
| ROC 50 N | Membrane Cleaner | NA |
| RoClean™ L102 | Membrane Cleaner | NA |
| RoClean™ L112 | Membrane Cleaner | NA |
| RoClean™ L211 | Membrane Cleaner | NA |
| RoClean™ L212 | Membrane Cleaner | NA |
| RoClean™ L403 | Membrane Cleaner | NA |
| RoClean™ L612 | Membrane Cleaner | NA |
| RoClean™ L811 | Membrane Cleaner | NA |
| RoClean™ L904 | Membrane Cleaner | NA |
Facility : SHK, USA
|
Miscellaneous Chemical Products[1] |
||
| Trade Designation | Product Function | Max Use |
| AvistaClean™ P0327 | Membrane Cleaner | NA |
| AvistaClean™ P1219 | Membrane Cleaner | NA |
| AvistaClean™ P611 | Membrane Cleaner | NA |
| AvistaClean™MF 3000 | Membrane Cleaner | NA |
| Avista™ 127 | Membrane Cleaner | NA |
| Avista™ 146 | Membrane Cleaner | NA |
| Avista™ 192 | Membrane Cleaner | NA |
| Avista™ 199 | Membrane Cleaner | NA |
| Avista™ RC P111 | Membrane Cleaner | NA |
| Avista™ RC P112 | Membrane Cleaner | NA |
| Avista™ RC P192 | Membrane Cleaner | NA |
| Avista™ RC P303 | Membrane Cleaner | NA |
| Avista™ RC P611 | Membrane Cleaner | NA |
| Avista™ RC P903 | Membrane Cleaner | NA |
| RoClean™ P111 | Membrane Cleaner | NA |
| RoClean™ P112 | Membrane Cleaner | NA |
| RoClean™ P192 | Membrane Cleaner | NA |
| RoClean™ P303 | Membrane Cleaner | NA |
| RoClean™ P611 | Membrane Cleaner | NA |
| RoClean™ P903 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| AvistaClean™ L0381[1] | Membrane Cleaner | NA |
| AvistaClean™ L1181[1] [3] | Membrane Cleaner | NA |
| AvistaClean™ L1211 NA | Membrane Cleaner | NA |
| AvistaClean™ L1221[1] [3] | Membrane Cleaner | NA |
| Avista™ RC L112 | Membrane Cleaner | NA |
| Avista™ RC L211[1] [3] | Membrane Cleaner | NA |
| Avista™ RC L212[1] [3] | Membrane Cleaner | NA |
| Avista™ RC L403[1] | Membrane Cleaner | NA |
| Avista™ RC L811[1] [3] | Membrane Cleaner | NA |
| Avista™177[1] | Membrane Cleaner | NA |
| Avista™181[1] | Membrane Cleaner | NA |
| ROC 20 N[1] | Membrane Cleaner | NA |
| ROC 50 N[1] | Membrane Cleaner | NA |
| RoClean™ L102[1] [3] | Membrane Cleaner | NA |
| RoClean™ L112 | Membrane Cleaner | NA |
| RoClean™ L211[1] [3] | Membrane Cleaner | NA |
| RoClean™ L212[1] [3] | Membrane Cleaner | NA |
| RoClean™ L403[1] | Membrane Cleaner | NA |
| RoClean™ L612 | Membrane Cleaner | NA |
| RoClean™ L811[1] [3] | Membrane Cleaner | NA |
| RoClean™ L904[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Kurita America Inc. (Formerly, Avista Technologies, Inc.) | ![]() |
| 6600 94th Avenue North | |
| Minneapolis, MN 55455 | |
| United States | |
| 760-744-0536 | |
| Visit this company's website |
Facility : Santa Fe Springs, CA
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| AvistaClean™ P1219[2] | Membrane Cleaner | NA |
| Avista® 192[2] | Membrane Cleaner | NA |
| Avista™ RC P192[2] | Membrane Cleaner | NA |
| RoClean™ P192[2] | Membrane Cleaner | NA |
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[3] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
[4] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
requirements for percent monomer and dose.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| AVISTA 177[1] | Membrane Cleaner | NA |
| Avista RC L112[1] | Membrane Cleaner | NA |
| Avista RC L211[1] | Membrane Cleaner | NA |
| Avista RC L212[1] | Membrane Cleaner | NA |
| Avista RC L403[1] | Membrane Cleaner | NA |
| AvistaClean L1211[1] | Membrane Cleaner | NA |
| AvistaClean L1221[1] | Membrane Cleaner | NA |
| AvistaClean® P611 | Membrane Cleaner | NA |
| AvistaClean™ L0381[1] | Membrane Cleaner | NA |
| AvistaClean™ L1177[1] | Membrane Cleaner | NA |
| AvistaClean™ L1181[1] [2] | Membrane Cleaner | NA |
| AvistaClean™ L1221[1] [2] | Membrane Cleaner | NA |
| AvistaClean™ MF 3000[1] [2] | Membrane Cleaner | NA |
| AvistaClean™ P0327[1] | Membrane Cleaner | NA |
| Avista® 127[1] | Membrane Cleaner | NA |
| Avista® 146 | Membrane Cleaner | NA |
| Avista® 181[1] | Membrane Cleaner | NA |
| Avista™RC L211[1] | Membrane Cleaner | NA |
| Avista™RC L212[1] [2] | Membrane Cleaner | NA |
| Avista™RC L403[1] | Membrane Cleaner | NA |
| Avista™RC L811[1] [2] | Membrane Cleaner | NA |
| Avista™RC P111[1] | Membrane Cleaner | NA |
| Avista™RC P112[1] [2] | Membrane Cleaner | NA |
| Avista™RC P303[1] [2] | Membrane Cleaner | NA |
| Avista™RC P611 | Membrane Cleaner | NA |
| Avista™RC P903[1] | Membrane Cleaner | NA |
| PAClean-LPH[1] | Membrane Cleaner | NA |
| PAClean-LPH[1] | Membrane Cleaner | NA |
| RoClean L211[1] | Membrane Cleaner | NA |
| RoClean L212[1] | Membrane Cleaner | NA |
| RoClean L403[1] | Membrane Cleaner | NA |
| RoClean™ L112[1] | Membrane Cleaner | NA |
| RoClean™ L211[1] | Membrane Cleaner | NA |
| RoClean™ L212[1] [2] | Membrane Cleaner | NA |
| RoClean™ L403[1] | Membrane Cleaner | NA |
| RoClean™ L811[1] [2] | Membrane Cleaner | NA |
| RoClean™ P111[1] | Membrane Cleaner | NA |
| RoClean™ P112[1] [2] | Membrane Cleaner | NA |
| RoClean™ P303[1] [2] | Membrane Cleaner | NA |
| RoClean™ P611 | Membrane Cleaner | NA |
| RoClean™ P903[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Kurita Water (Malaysia) Sdn. Bhd. | |
| No. 89B, Jalan i-Park 1/10, Kawasan | |
| Perindustrian i-Park, Bandar Indahpura | |
| 81000 Kulai, Johor (Company No: 289658-X) | |
| Malaysia | |
| 65 6861 2622 | |
| Visit this company's website |
Facility : Johor, Malaysia
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Avista™ 192[3] [4] | Membrane Cleaner | NA |
| Avista™ RC L211[3] [4] | Membrane Cleaner | N/A |
| Avista™ RC L212[3] [4] | Membrane Cleaner | N/A |
| Avista™ RC L403[3] [4] | Membrane Cleaner | N/A |
| Avista™ RC L811[3] [4] | Membrane Cleaner | N/A |
| Avista™ RC P111[4] [5] | Membrane Cleaner | N/A |
| Avista™ RC P112[3] [4] | Membrane Cleaner | N/A |
| Avista™ RC P303[3] [4] | Membrane Cleaner | NA |
| Avista™ RC P903[3] [4] | Membrane Cleaner | NA |
| KURIVERTER IK-110[8] | Membrane Cleaner | NA |
| RoClean™ L211[3] [4] | Membrane Cleaner | N/A |
| RoClean™ L212[3] [4] | Membrane Cleaner | N/A |
| RoClean™ L403 [3] [4] | Membrane Cleaner | N/A |
| RoClean™ L811 | Membrane Cleaner | N/A |
| RoClean™ P111[4] [5] | Membrane Cleaner | N/A |
| RoClean™ P112 [3] [4] | Membrane Cleaner | N/A |
| RoClean™ P192 | Membrane Cleaner | NA |
| RoClean™ P303[3] [4] | Membrane Cleaner | NA |
| RoClean™ P903[3] [4] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[5] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions. The system should be
flushed with 5 bed/volumes of water, before being placed back on-line.
[6] Certified for use with nanofiltration membranes composed of polyamide thin-film
composite with a minimum salt rejection of 97% (for MgSO4 at 2,000 mg/L and 70 psi).
[7] This product is designed to reduce biofilm on reverse osmosis membrane through continued
injection (online) at the recommended dosage and shall be subject to the said maximum
use.
[8] In the case to be used as membrane cleaner, this product shall be used offline and is to
be flushed out prior to using the system for drinking water, following the
manufacturer's use instructions.
|
||
| Kurita Water Industries (Dalian) Co., Ltd. | |
| 33-27, Dalian Industrial Park | |
| Dalian Economic & Technical Dvlpmt. Zone | |
| Dalian, Liaoning Province 116600 | |
| China | |
| 86 411 8761 3520 | |
| Visit this company's website |
Facility : Liaoning Province, China
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| KURITA K-1100[2] | Membrane Cleaner | NA |
| KURITA M-2130[4] | Membrane Cleaner | NA |
| KURITA M-2131[4] | Membrane Cleaner | NA |
| KURITA M-2140 | Membrane Cleaner | NA |
[1] This product is designed to reduce biofilm on reverse osmosis membranes.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into
service. This product is designed to be used off-line and flushed out prior to using
the system for drinking water, following manufacturer's use
instructions.
[4] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Kurita Water Industries (Taixing) Co., Ltd. | |
| No. 18 Runjiang Rd Dev. High-Tech Park | |
| Binjiang Town, Taixing City, Jiangsu | |
| China |
Facility : Jiangsu, China
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| KURITA K-1100 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Mid South Chemical Company, Inc. | |
| 5681 Highway 4 S.E. | |
| P.O. Box 116 | |
| Ringgold, LA 71068 | |
| United States | |
| 318-894-7301 | |
| Visit this company's website |
Facility : Ringgold, LA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| RO 1306[1] | Membrane Cleaner | NA |
| RO 1307 | Membrane Cleaner | NA |
| RO 1324[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Monit Inc (DBA: Sun Professional Supply) | |
| 5466 West Beaver Street | |
| Jacksonville, FL 32254 | |
| United States | |
| 904-693-0577 | |
| Visit this company's website |
Facility : Jacksonville, FL
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Natural-Solv | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
| Nalco Company | |
| 1601 West Diehl Road | |
| Naperville, IL 60563-1198 | |
| United States | |
| 630-305-1000 | |
| Visit this company's website |
Facility : #101 USA
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| NALCO® PC-96[2] | Membrane Cleaner | NA |
| Nalco PC-98[2] | Membrane Cleaner | NA |
| PERMACLEAN™ PC-98 PLUS[2] | Membrane Cleaner | NA |
| PermaClean™ PC-97 | Membrane Cleaner | NA |
| PermaClean™ PC-98[2] | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following the manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #109 USA
|
Phosphoric Acid |
||
| Trade Designation | Product Function | Max Use |
| 3D TRASAR™ 3DT186[3] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #111 USA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| PermaClean™ PC-97[1] | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
|
||
|
Phosphoric Acid |
||
| Trade Designation | Product Function | Max Use |
| 3D TRASAR™ 3DT186[2] | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #140 USA
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| NALCO® PC-96[3] | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] This product is to be used for the long term storage of ultrafiltration membranes.
Following storage the solution should be drained from the membrane and flushed according
to manufacturers use instructions. A flush volume of 100L/M2 should be applied for 125
minutes or a flush volume of 20L/M2 should be applied for 140 minutes.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[5] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-33 | Membrane Cleaner | NA |
[5] These products are designed to be used off-line and flushed out prior to using the
system for drinking water. The pH of the influent and effluent water should be monitored
to ensure that all traces of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-67 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| Nalco PC-77 | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
|
||
|
Miscellaneous Water Supply Products[5] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-98 | Membrane Cleaner | NA |
| PermaClean™ PC-33 | Membrane Cleaner | NA |
[5] These products are designed to be used off-line and flushed out prior to using the
system for drinking water. The pH of the influent and effluent water should be monitored
to ensure that all traces of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| PermaClean™ PC-40 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| PermaClean™ PC-67 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| PermaClean™ PC-77 | Membrane Cleaner | NA |
| PermaClean™ PC-97 | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
|
||
|
Miscellaneous Water Supply Products[5] |
||
| Trade Designation | Product Function | Max Use |
| PermaClean™ PC-98 | Membrane Cleaner | NA |
[5] These products are designed to be used off-line and flushed out prior to using the
system for drinking water. The pH of the influent and effluent water should be monitored
to ensure that all traces of the product have been removed before placing into service.
|
||
|
Phosphoric Acid |
||
| Trade Designation | Product Function | Max Use |
| 3D TRASAR™ 3DT186 [6] | Membrane Cleaner | NA |
[6] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #150 Canada
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-98[2] | Membrane Cleaner | NA |
| PermaClean™ PC-98[2] | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Phosphoric Acid |
||
| Trade Designation | Product Function | Max Use |
| 3D TRASAR™ 3DT186[3] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
[5] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #702 USA
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Filtrapure Liquid Acid Cleaner | Membrane Cleaner | NA |
| Filtrapure Liquid TF | Membrane Cleaner | NA |
| PermaClean™ PC-90 | Membrane Cleaner | NA |
| PermaClean™ PC-97 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #1140 United Kingdom
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-33 | Membrane Cleaner | NA |
| Nalco PC-67 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| Nalco PC-77 | Membrane Cleaner | NA |
| OsmoTreat OSM711 | Membrane Cleaner | NA |
| OsmoTreat OSM724 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| PermaClean PC-33 | Membrane Cleaner | NA |
| PermaClean PC-67 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| PermaClean PC-77 | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and shall be flushed and drained before
being placed into service, following manufacturer's use instructions. The pH of the
influent and effluent water shall be monitored to ensure that all traces of the product
have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #2120 Brazil
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| NALCO® PC-96 | Membrane Cleaner | NA |
| Nalco PC-33 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water.
[2] The pH of the influent and effluent water shall be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-77 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water.
|
||
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| PermaClean™ PC-33 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water.
[2] The pH of the influent and effluent water shall be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| PermaClean™ PC-67 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| PermaClean™ PC-77 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #2135 Santiago, Chile
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-33[1] [2] | Membrane Cleaner | NA |
| PermaClean™ PC-33[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #2150 Mexico
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-77[2] | Membrane Cleaner | NA |
| Nalco PC-98[2] [3] | Membrane Cleaner | NA |
| PermaClean™ PC-77[2] | Membrane Cleaner | NA |
| PermaClean™ PC-98[2] [3] | Membrane Cleaner | NA |
[1] Certified for use as an off-line membrane cleaner. When used as an off-line membrane
cleaner, this product is designed to be flushed out prior to using the system for
drinking water. Follow manufacturer's use instructions.
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : # 3100 Victoria Australia
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| PERMACLEAN™ PC-97A | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #3103 Cheltenham
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| PERMACLEAN™ PC-97A | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #3104 Darra
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| PERMACLEAN™ PC-97A | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #3125 Australia
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| PERMACLEAN™ PC-97A[1] | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #4105 Korea, Republic of
|
Ammonium Sulfate |
||
| Trade Designation | Product Function | Max Use |
| PermaClean PC-80[1] | Membrane Cleaner | NA |
[1] Certified for use as an off-line membrane cleaner. When used as an off-line membrane
cleaner, this product is designed to be flushed out prior to using the system for
drinking water. Follow manufacturer’s use instructions.Certified for use as an off-line
membrane cleaner. When used as an off-line membrane cleaner, this product is designed
to be flushed out prior to using the system for drinking water. Follow manufacturer’s
use instructions.
[2] Certified for use as an online biocide aid for membranes when used in combination with
PermaClean PC-22, at the maximum use level of 30 mg/L.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| NALCO® PC-96[3] [5] | Membrane Cleaner | NA |
| Nalco PC-77[3] | Membrane Cleaner | NA |
| PermaClean® PC-22[1] | Membrane Cleaner | NA |
| PermaClean™ PC-77[3] [5] | Membrane Cleaner | NA |
| PermaClean™ PC-77[3] | Membrane Cleaner | NA |
[1] Certified for use as an off-line membrane cleaner. When used as an off-line membrane
cleaner, this product is designed to be flushed out prior to using the system for
drinking water. Follow manufacturer’s use instructions.Certified for use as an off-line
membrane cleaner. When used as an off-line membrane cleaner, this product is designed
to be flushed out prior to using the system for drinking water. Follow manufacturer’s
use instructions.
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] This product is to be used for the long term storage of ultrafiltration membranes.
Following storage the solution should be drained from the membrane and flushed according
to manufacturers use instructions. A flush volume of 100 L/M2 should be applied for 125
minutes or a flush volume of 20L/M2 should be applied for 140 minutes.
[5] The pH of the influent and effluent water shall be monitored to ensure that all traces
of the product have been removed before placing into service.
[6] Certified for use as an online membrane biocide at a maximum use level (MUL) of 25 mg/L.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #4110 India
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-33 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water shall be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-67 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
|
||
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-77 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| Nalco PC-98 | Membrane Cleaner | NA |
| Nalco PC-98 | Membrane Cleaner | NA |
| PermaClean™ PC-33 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| PermaClean™ PC-40 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water shall be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| PermaClean™ PC-67 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
|
||
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| PermaClean™ PC-77 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| PermaClean™ PC-98 | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water shall be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #4111 India
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-33[1] [2] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| Nalco PC-67[1] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| Nalco PC-77[1] [2] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| Nalco PC-98[1] [2] | Membrane Cleaner | NA |
| PermaClean™ PC-33[1] [2] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| PermaClean™ PC-40[1] [2] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| PermaClean™ PC-67[1] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| PermaClean™ PC-77[1] [2] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| PermaClean™ PC-98[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] This pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #4118 Dammam II, Saudi Arabia
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-33[1] [2] | Membrane Cleaner | NA |
| PermaClean™ PC-33[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #4120 Indonesia
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-77[2] | Membrane Cleaner | NA |
| Nalco PC-98 | Membrane Cleaner | NA |
| PermaClean™ PC-77[2] | Membrane Cleaner | NA |
| PermaClean™ PC-98[2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #4150 Taiwan
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| OsmoTreat™ OSM711 | Membrane Cleaner | NA |
| OsmoTreat™ OSM731[1] | Membrane Cleaner | NA |
| PermaClean® PC-22[3] [CL] | Membrane Cleaner | NA |
| PermaClean™ PC-33[1] | Membrane Cleaner | NA |
| Nalco PC-33[1] | Membrane Cleaner | NA |
| Nalco PC-77[1] | Membrane Cleaner | NA |
| PermaClean™ PC-77[1] | Membrane Cleaner | NA |
[1] These products are designed to be used off-line. These products are designed to be
flushed out prior to using the system for drinking water, following the manufacturer's
use instructions.
[2] Certified for use as an online membrane biocide at a maximum use level (MUL) of 25 mg/L.
[3] Certified for use as an off-line membrane cleaner. When used as an off-line membrane
cleaner, this product is designed to be flushed out prior to using the system for
drinking water. Follow manufacturer's use instructions.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Scott, LA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| NALCO® PC-96[1] [2] | Membrane Cleaner | NA |
| Nalco PC-77[1] [3] | Membrane Cleaner | NA |
| Nalco PC-98[1] [2] | Membrane Cleaner | NA |
| PermaClean™ PC-77[1] [3] | Membrane Cleaner | NA |
| PermaClean™ PC-87[1] | Membrane Cleaner | NA |
| PermaClean™ PC-98[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[3] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Bogotá D.C., Colombia
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-33[2] | Membrane Cleaner | NA |
| Nalco PC-77 | Membrane Cleaner | NA |
| PermaClean™ PC-33[2] | Membrane Cleaner | NA |
| PermaClean™ PC-67 | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| PermaClean™ PC-77 | Membrane Cleaner | NA |
| PermaClean™ PC-87 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Rayong, Thailand
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-67[3] | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| Nalco PC-77[3] | Membrane Cleaner | NA |
| Nalco PC-98[2] | Membrane Cleaner | NA |
| PermaClean™ PC-77[3] | Membrane Cleaner | NA |
| PermaClean™ PC-98[2] | Membrane Cleaner | NA |
[1] Certified for use as an off-line membrane cleaner. When used as an off-line membrane
cleaner, this product is designed to be flushed out prior to using the system for
drinking water. Follow manufacturer's use instructions.
[2] These products are designed to be used off-line and flushed out prior to using the
system for drinking water. The pH of the influent and effluent water should be
monitored to ensure that all traces of the product have been removed before placing into
service.
[3] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Nalco Company | |
| 1601 West Diehl Road | |
| Naperville, IL 60563 | |
| United States | |
| 630-305-1000 | |
| Visit this company's website |
Facility : #4165 China
|
Ammonium Sulfate |
||
| Trade Designation | Product Function | Max Use |
| PermaClean PC-80[2] | Membrane Cleaner | NA |
[1] Certified for use as an online biocide aid for membranes when used in combination with
PermaClean PC-22, at the maximum use level of 30 mg/L.
[2] Certified for use as an off-line membrane cleaner. When used as an off-line membrane
cleaner, this product is designed to be flushed out prior to using the system for
drinking water. Follow manufacturer's use instructions.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| PermaClean™ PC-33[3] [4] | Membrane Cleaner | NA |
| PermaClean™ PC-77 | Membrane Cleaner | NA |
| PermaClean™ PC-77P | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] pH of the influent water should be monitored to ensure that all traces of the product
have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Nantong Uniphos Chemicals Co., Ltd. | |
| No. 8, Tonghai 2nd Road | |
| Yangkou Chemical Industrial Zone | |
| Nantong 226407 | |
| China | |
| 86 519 860 2045 | |
| Visit this company's website |
Facility : Nantong, China
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| SMR617 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] This product is designed to reduce biofilm on reverse osmosis membranes through
continued injection (online) at the recommended dosage and shall be subject to the said
maximum use.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| NCH Corporation DBA Chem-Aqua, Inc. | |
| 2727 Chemsearch Blvd. | |
| Irving, TX 75062 | |
| United States | |
| 866-209-3373 | |
| 972-438-0232 | |
| Visit this company's website |
Facility : Birmingham, AL
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Chem-Aqua 70562 | Membrane Cleaner | N/A |
| Chem-Aqua 70563 | Membrane Cleaner | N/A |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Next Filtration Technologies, Inc. | |
| 6586 Hypoluxo Road | |
| Suite 362 | |
| Lake Worth, FL 33467 | |
| United States | |
| 800-783-0310 | |
| 561-686-2619 | |
| Visit this company's website |
Facility : # 1 USA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Next FOG-Stop | Membrane Cleaner Reverse Osmosis Antiscalant |
34mg/L |
| Next FOG-Stop FGX3 | Membrane Cleaner Reverse Osmosis Antiscalant |
12mg/L |
| Northstar Chemical | |
| 14200 Southwest Tualatin Sherwood Road | |
| Sherwood, OR 97140 | |
| United States | |
| 888-793-9476 | |
| 503-625-3770 | |
| Visit this company's website |
Facility : #1 Santa Fe Springs, CA
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid[2] [3] | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
Facility : Modesto, CA
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid[2] [3] | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
Facility : Sherwood, OR
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service
|
||
| P.T. Kurita Indonesia | |
| Jl. Jababeka XIIA Kav. V-6 | |
| Kawasan Industri Jababeka | |
| Cikarang Bekasi, West Java | |
| Indonesia | |
| 62 21 893 6245 |
Facility : West Java, Indonesia
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| KURIDINE M-280 | Membrane Cleaner | NA |
| KURITA KD M-280 | Membrane Cleaner | NA |
[1] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by products should be monitored in
the finished drinking water to ensure compliance to all applicable regulations.
This product is designed to reduce biofilm on reverse osmosis membranes.
[2] This product is designed to reduce biofilm on reverse osmosis membranes.
|
||
| Praj Hipurity Systems Limited | |
| 1811/ 1182, 8th Floor, Building No. 11, | |
| Solitaire Corporate Park, Andheri Ghatkopar Link Rd | |
| Andheri East, Maharashtra 400093 | |
| India | |
| 91 84 25861310 |
Facility : Maharashtra, India
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| PV-CLEAN-101[3] | Membrane Cleaner | NA |
| PV-CLEAN-102[3] | Membrane Cleaner | NA |
[1] When this product is used offline, it is designed to be flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] This product is certified to NSF/ANSI/CAN 60, but it has not been registered under the
US FIFRA requirements and is not to be distributed within the USA.
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Professional Water Technologies, LLC | ![]() |
| 1048 La Mirada Court | |
| Vista, CA 92081 | |
| United States | |
| 800-914-9072 | |
| 760-639-4400 | |
| Visit this company's website |
Facility : Anaheim, CA
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| OptiClean A | Membrane Cleaner | NA |
| OptiClean B | Membrane Cleaner | NA |
| OptiClean B+ | Membrane Cleaner | NA |
| OptiClean D | Membrane Cleaner | NA |
| OptiClean N | Membrane Cleaner | NA |
| OptiClean S | Membrane Cleaner | NA |
| Preservol | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
Facility : National City, CA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| OptiClean A | Membrane Cleaner | NA |
| OptiClean B | Membrane Cleaner | NA |
| OptiClean B+ | Membrane Cleaner | NA |
| OptiClean D | Membrane Cleaner | NA |
| OptiClean N | Membrane Cleaner | NA |
| OptiClean S | Membrane Cleaner | NA |
| Preservol | Membrane Cleaner | NA |
Facility : Vista, CA
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| OptiClean™ ENZ | Membrane Cleaner | NA |
| OptiClean™ N | Membrane Cleaner | NA |
| OptiClean™ X Eco | Membrane Cleaner | NA |
| OptiClean™ Y Eco | Membrane Cleaner | NA |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Genesol 80[1] | Membrane Cleaner | NA |
| Genesol UF-Fe | Membrane Cleaner | NA |
| Lavasol™ 1[1] | Membrane Cleaner | NA |
| Lavasol™ 2[1] | Membrane Cleaner | NA |
| Lavasol™ 5[1] | Membrane Cleaner | NA |
| Lavasol™ 6[1] | Membrane Cleaner | NA |
| Lavasol™ 7[1] | Membrane Cleaner | NA |
| Lavasol™ 9[1] | Membrane Cleaner | NA |
| OptiClean A™[1] | Membrane Cleaner | NA |
| OptiClean B™[1] | Membrane Cleaner | NA |
| OptiClean S™[1] | Membrane Cleaner | NA |
| OptiClean™ B+[1] [2] | Membrane Cleaner | NAmg/L |
| OptiClean™ D[1] | Membrane Cleaner | NA |
| Preservol (liquid)[1] | Membrane Cleaner | NA |
| Preservol (powder)[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
Facility : Barcelona, Spain
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Lavasol™ 6 | Membrane Cleaner | NA |
| Lavasol™ 6P | Membrane Cleaner | NA |
| Lavasol™ 9 | Membrane Cleaner | NA |
| OptiClean™ A | Membrane Cleaner | NA |
| OptiClean™ G | Membrane Cleaner | NA |
| OptiClean™ S | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Pronto MS, Inc | |
| 24317 West 143rd Street | |
| Suite 115 | |
| Plainfield, IL 60544 | |
| United States | |
| 312-909-1888 | |
| Visit this company's website |
Facility : # 1 USA
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| F.O.G. Control | Membrane Cleaner Pipe Cleaning Aid |
NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Protein Matrix, LLC | |
| 1580 Northwest 3rd Street | |
| Deerfield Beach, FL 33442 | |
| United States | |
| 954-781-9200 | |
| Visit this company's website |
Facility : Lakeland, FL
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Eliminator | Membrane Cleaner Pipe Cleaning Aid |
NA |
| Liquid Gopher | Membrane Cleaner Pipe Cleaning Aid |
NA |
| PM-1 | Membrane Cleaner Pipe Cleaning Aid |
NA |
| PM-4 | Membrane Cleaner Pipe Cleaning Aid |
NA |
| Protein Matrix Industrial Grease Remediation | Membrane Cleaner Pipe Cleaning Aid |
NA |
| Uncle Oscar's FOG Control | Membrane Cleaner Pipe Cleaning Aid |
NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| PT. Beta Pramesti Asia | |
| JI. Matraman Raya 169 | |
| Jakarta 13140 | |
| Indonesia | |
| 62 21 858 0838 | |
| Visit this company's website |
Facility : West Java, Indonesia
|
Citric Acid[3] [4] |
||
| Trade Designation | Product Function | Max Use |
| HYDRO 277 | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent should be monitored to ensure that all traces of the
product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[3] [4] |
||
| Trade Designation | Product Function | Max Use |
| HYDRO 566 | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent should be monitored to ensure that all traces of the
product have been removed before placing into service.
|
||
| Pure Chemicals Co. | |
| No. 32, H Block, 15th Main Road | |
| Anna Nagar, West Chennai | |
| Tamil Nadu 600040 | |
| India | |
| 91 944 5393551 | |
| Visit this company's website |
Facility : Tamil Nadu, India
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| PURER RO 311 | Membrane Cleaner | NA |
| PURER RO 322 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Rakiro Biotech Systems Private Limited | |
| R466 TTC Industrial Area | |
| MIDC Rabale | |
| Navi Mumbai, Maharashtra 400701 | |
| India | |
| 91 222 7642236 | |
| Visit this company's website |
Facility : Navi Mumbai, India
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| UDAAQ WTROC1600[3] | Membrane Cleaner | NA |
| UDAAQ WTROC1800[3] | Membrane Cleaner | NA |
[1] When this product is used offline, it is designed to be flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] This product is certified to NSF/ANSI/CAN 60, but it has not been registered under the
US FIFRA requirements and is not to be distributed within the USA.
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| SAL Chemical Company, Inc. | |
| Half Moon Industrial Park | |
| 3036 Birch Drive | |
| Weirton, WV 26062 | |
| United States | |
| 800-879-1725 | |
| 304-748-8200 | |
| Visit this company's website |
Facility : # 1 USA
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Shannon Chemical Corp. | |
| P.O. Box 376 | |
| Malvern, PA 19355 | |
| United States | |
| 610-363-9090 |
Facility : Columbus, OH
|
Citric Acid[1] [WL] |
||
| Trade Designation | Product Function | Max Use |
| SE-CA-50 | Well Cleaning Aid Membrane Cleaner |
N/A |
[1] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[WL] These products are designed to be flushed out prior to using the system for drinking
water. The well shall be properly flushed and drained before being placed in service.
|
||
Facility : Exton , PA
|
Citric Acid[1] [WL] |
||
| Trade Designation | Product Function | Max Use |
| SE-CA-50 | Well Cleaning Aid Membrane Cleaner |
N/A |
[1] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[WL] These products are designed to be flushed out prior to using the system for drinking
water. The well shall be properly flushed and drained before being placed in service.
|
||
Facility : Exton, PA
|
Citric Acid[2] [3] |
||
| Trade Designation | Product Function | Max Use |
| SE-CA-50 | Well Cleaning Aid Membrane Cleaner |
N/A |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
Facility : Dallas, TX
|
Citric Acid[2] [3] |
||
| Trade Designation | Product Function | Max Use |
| SE-CA-50 | Well Cleaning Aid Membrane Cleaner |
N/A |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Sion California LLC | |
| 6650 North Locan | |
| Clovis, CA 93619 | |
| United States | |
| 559-287-1988 | |
| Visit this company's website |
Facility : Fowler, CA
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| HYD-1000 | Membrane Cleaner | NA |
| HYD-1000 | Membrane Cleaner | NA |
| HYD-250 | Membrane Cleaner | NA |
| HYD-500 | Membrane Cleaner | NA |
| OXI-1000 | Membrane Cleaner | NA |
| OXI-2000 | Membrane Cleaner | NA |
| OXI-250 | Membrane Cleaner | NA |
| OXI-500 | Membrane Cleaner | NA |
| OXONIUM | Membrane Cleaner | NA |
| SION-HYD | Membrane Cleaner | NA |
| STABILIZED HYDRONIUM | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Solenis LLC | |
| 500 Hercules Road | |
| Wilmington, DE 19808 | |
| United States | |
| 302-594-5000 | |
| Visit this company's website |
Facility : Ankleshwar, Gujarat, India
|
Aminotrimethylene Phosphonic Acid |
||
| Trade Designation | Product Function | Max Use |
| Ameroyal C1000[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Ameroyal 8301 | Membrane Cleaner | N/A |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
Facility : Helsingborg, Sweden
|
Aminotrimethylene Phosphonic Acid |
||
| Trade Designation | Product Function | Max Use |
| Ameroyal C1000 Cleaner[2] | Membrane Cleaner | NA |
| Ameroyal C800[1] [2] | Membrane Cleaner | NA |
[1] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[2] This product is designed to used off-line and flushed out prior to using the system for
drinking water, following manufacturer's use instructions.
|
||
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Ameroyal 8301 | Membrane Cleaner | NA |
Facility : Nantou, Taiwan
|
Aminotrimethylene Phosphonic Acid |
||
| Trade Designation | Product Function | Max Use |
| Ameroyal C1000[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacture's use instructions.
|
||
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Ameroyal 8301[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacture's use instructions.
|
||
| Southeastern Tank Inc. DBA Solutions by SET | |
| 60 Vesta Road | |
| Lebanon, TN 37090 | |
| United States | |
| 615-466-5220 | |
| Visit this company's website |
Facility : Loretto, TN
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50%[2] | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Sterling Water Technologies, LLC | |
| P.O. Box 602 | |
| Columbia, TN 38402-0602 | |
| United States | |
| 800-426-2428 | |
| 931-540-1334 | |
| Visit this company's website |
Facility : # 7 USA
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| CMC 150 | Membrane Cleaner | NA |
| Citric Acid Anhydrous | Membrane Cleaner | NA |
Facility : # 14 USA
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| CMC 150 | Membrane Cleaner | NA |
| Citric Acid Anhydrous | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| The Dycho Company Inc. | |
| P.O. Box 513 | |
| Niota, TN 37826 | |
| United States | |
| 423-568-2112 |
Facility : # 3 USA
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50%[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| The National Colloid Company | |
| 906 Adams Street | |
| Steubenville, OH 43952 | |
| United States | |
| 740-282-1171 | |
| Visit this company's website |
Facility : Steubenville, OH
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Natco CA-50 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Thornton, Musso & Bellemin, Inc. | |
| 4788 Waywood Drive | |
| P.O. Box 181 | |
| Zachary, LA 70791 | |
| United States | |
| 800-762-9104 | |
| 225-654-4955 | |
| Visit this company's website |
Facility : # 7 USA
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid Anhydrous | Membrane Cleaner | NA |
| TMB 750C | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
Facility : # 10 USA
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | NA |
| Citric Acid Anhydrous | Membrane Cleaner | NA |
| TMB 750C | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Univar Solutions Canada Ltd. DBA Univar Canada Ltd. | |
| 64 Arrow Road | |
| North York, ON M9M 2L9 | |
| Canada | |
| 416-740-5300 |
Facility : Abbotsford, British Columbia, Canada
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| CITRIC ACID 50%[1] | Well Cleaning Aid Membrane Cleaner |
NA |
| CITRIC ACID 50% SOLUTION[1] | Well Cleaning Aid Membrane Cleaner |
NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions. The well is to be
properly flushed and drained before being placed in service.
|
||
Facility : Guelph, Ontario, Canada
|
Citric Acid[2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : Valleyfield, Québec, Canada
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| CITRIC ACID 50% | Well Cleaning Aid Membrane Cleaner |
NA |
| CITRIC ACID 50% SOLUTION | Well Cleaning Aid Membrane Cleaner |
NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Univar Solutions USA | |
| 3075 Highland Parkway | |
| Suite 200 | |
| Downers Grove, IL 60515 | |
| United States | |
| 425-889-3400 |
Facility : Fresno, CA
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 30% | Membrane Cleaner | NA |
| Citric Acid 50% | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Redwood City, CA
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid, 50% | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacture's use instructions.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Santa Fe Springs, CA
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid, 50% | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Visalia, CA
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid, 50% | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Denver, CO
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% Solution | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Distribution Center - Dallas, GA
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | NA |
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Norcross, GA
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Caflon P-RO 12.0 | Membrane Cleaner | NA |
| Caflon P-RO 3.0 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Geneva, NY
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Charlotte, NC
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid, 50% Solution | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Altoona, PA
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Spartanburg, SC
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid, 50% Solution | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Salt Lake City, UT
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% Solution[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Chester, VA
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Caflon P-RO 12.0 | Membrane Cleaner | NA |
| Caflon P-RO 3.0 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
Facility : Houston, TX
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50% Solution | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Caflon P-RO 12.0 | Membrane Cleaner | NA |
| Caflon P-RO 3.0 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
NOTE: Only products bearing the "NSF 60" designation are Certified by NSF International.
| Veolia Water Solutions & Technologies, Saudi-Chemical Industries | |
| Prince Musaed Bin Adulaziz Street | |
| Riyadh 58515 | |
| Saudi Arabia | |
| 966 1 478 7721 | |
| Visit this company's website |
Facility : Riyadh, Saudi Arabia
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Hydrex 4708 | Membrane Cleaner | NA |
[1] Certified for on-line use to maximum use level of 45 mg/L for brackish water membrane
systems.
[2] Certified for on-line use to maximum use level of 100 mg/L for seawater membrane systems.
|
||
| Veolia Water Technologies & Solutions | |
| 3600 Horizon Boulevard | |
| Trevose, PA 19053 | |
| United States | |
| 215-355-3300 | |
| Visit this company's website |
Facility : # 3 USA
|
Citric Acid [7] |
||
| Trade Designation | Product Function | Max Use |
| Kleen MCT407[3] [6] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[6] The well is to be properly flushed and drained before being placed in service.
[7] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products[3] [7] |
||
| Trade Designation | Product Function | Max Use |
| Kleen MCT405[4] | Membrane Cleaner | NA |
| Kleen MCT515 | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[7] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : # 9 USA
|
Citric Acid [7] |
||
| Trade Designation | Product Function | Max Use |
| Kleen MCT407[3] [6] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[6] The well is to be properly flushed and drained before being placed in service.
[7] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products [7] |
||
| Trade Designation | Product Function | Max Use |
| KLEEN MCT115[3] [4] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[7] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Sodium Hydroxide [7] |
||
| Trade Designation | Product Function | Max Use |
| MPH2500[3] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[7] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : # 11 USA
|
Citric Acid [10] |
||
| Trade Designation | Product Function | Max Use |
| Kleen MCT407[2] [9] | Membrane Cleaner | NA |
| MEMCHEM MCT201[2] | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer’s use instructions.
[9] The well is to be properly flushed and drained before being placed in service.
[10] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products [10] |
||
| Trade Designation | Product Function | Max Use |
| KLEEN MCT115[2] [7] | Membrane Cleaner | NA |
| Kleen MCT105 | Membrane Cleaner | NA |
| Kleen MCT105[2] [7] | Membrane Cleaner | NA |
| Kleen MCT405[2] [7] | Membrane Cleaner | NA |
| Kleen MCT515[2] | Membrane Cleaner | NA |
| MEMCHEM MCT210[2] | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer’s use instructions.
[5] Certified to be used in conjunction with Scaletrol PDC9323 at equal to or less than 17%.
[6] Certified to be used in conjunction with Scaletrol PDC9323 at equal to or less than 7%.
[7] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[10] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Sodium Hydroxide[10] |
||
| Trade Designation | Product Function | Max Use |
| MPH2500 | Membrane Cleaner | NA |
[10] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : # 33 USA
|
Miscellaneous Water Supply Products [7] |
||
| Trade Designation | Product Function | Max Use |
| KLEEN MCT115[3] [4] | Membrane Cleaner | NA |
| Kleen MCT515[3] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[7] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Sodium Hydroxide [7] |
||
| Trade Designation | Product Function | Max Use |
| MPH2500[3] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[7] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : # 41 Canada
|
Citric Acid [7] |
||
| Trade Designation | Product Function | Max Use |
| Kleen MCT407[3] [6] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[6] The well is to be properly flushed and drained before being placed in service.
[7] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products [7] |
||
| Trade Designation | Product Function | Max Use |
| Kleen MCT405[3] [4] | Membrane Cleaner | NA |
| Kleen MCT515[3] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[7] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Sodium Hydroxide [7] |
||
| Trade Designation | Product Function | Max Use |
| MPH2500[3] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[7] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : Buenos Aires, Argentina
|
Miscellaneous Water Supply Products[1] [3] |
||
| Trade Designation | Product Function | Max Use |
| KLEEN MCT105[2] | Membrane Cleaner | NA |
| KLEEN MCT405[2] | Membrane Cleaner | NA |
| KLEEN MCT405L | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[3] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : Carole Park, Queensland
|
Citric Acid[1] [3] |
||
| Trade Designation | Product Function | Max Use |
| Memchem MCT201 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products[1] [3] |
||
| Trade Designation | Product Function | Max Use |
| Kleen MCT105[2] | Membrane Cleaner | NA |
| Kleen MCT405[2] | Membrane Cleaner | NA |
| Memchem MCT210 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[3] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : Herentals, Belgium
|
Citric Acid[2] [6] |
||
| Trade Designation | Product Function | Max Use |
| MemChem MCT201 | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[6] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products[2] [3] [6] |
||
| Trade Designation | Product Function | Max Use |
| KLEEN MCT105 | Membrane Cleaner | NA |
| KLEEN MCT405 | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[6] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products[2] [6] |
||
| Trade Designation | Product Function | Max Use |
| MEMCHEM MCT210 | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[6] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : Sorocaba, Brazil
|
Miscellaneous Water Supply Products [7] |
||
| Trade Designation | Product Function | Max Use |
| KLEEN BC9528[3] [5] | Membrane Cleaner | NA |
| KLEEN MCT105[3] [5] | Membrane Cleaner | NA |
| KLEEN MCT405L[3] | Membrane Cleaner | NA |
| Kleen MCT405[3] [5] | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] This product is exclusively for sale and distribution outside of the United States.
[5] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[7] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : Wuxi, China
|
Citric Acid[1] [6] |
||
| Trade Designation | Product Function | Max Use |
| MEMCHEM MCT201 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[6] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products[1] [3] [6] |
||
| Trade Designation | Product Function | Max Use |
| KLEEN MCT105 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[6] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products [6] |
||
| Trade Designation | Product Function | Max Use |
| Kleen MCT405 | Membrane Cleaner | NA |
[4] Certified for addition to the feedwater for evaporative desalination units only.
[6] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products[1] [3] [6] |
||
| Trade Designation | Product Function | Max Use |
| Kleen MCT405 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[6] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products [6] |
||
| Trade Designation | Product Function | Max Use |
| MEMCHEM MCT210 | Membrane Cleaner | NA |
[4] Certified for addition to the feedwater for evaporative desalination units only.
[6] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : Crissey, France
|
Citric Acid[2] [5] |
||
| Trade Designation | Product Function | Max Use |
| MemChem MCT201 | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products[2] [3] [5] |
||
| Trade Designation | Product Function | Max Use |
| KLEEN MCT405 | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products[2] [5] |
||
| Trade Designation | Product Function | Max Use |
| MEMCHEM MCT210 | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : Bangalore, India
|
Citric Acid[1] [5] |
||
| Trade Designation | Product Function | Max Use |
| BETZ MPH5000[2] | Membrane Cleaner | NA |
| MemChem MCT201 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products[1] [5] |
||
| Trade Designation | Product Function | Max Use |
| KLEEN MCT105[2] | Membrane Cleaner | NA |
| KLEEN MCT115 | Membrane Cleaner | NA |
| KLEEN MCT405[2] | Membrane Cleaner | NA |
| Kleen MCT515 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : Jeollabuk-do, Republic of Korea
|
Miscellaneous Water Supply Products[2] |
||
| Trade Designation | Product Function | Max Use |
| KLEEN MCT405 | Membrane Cleaner | NA |
[2] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : Umbogintwini, South Africa
|
Miscellaneous Water Supply Products [4] |
||
| Trade Designation | Product Function | Max Use |
| KLEEN MCT405[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[4] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
Facility : Dubai, United Arab Emirates
|
Citric Acid[1] [4] |
||
| Trade Designation | Product Function | Max Use |
| MemChem MCT201 | Membrane Cleaner | NA |
[1] This product is designed to be use off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products[1] [2] [4] |
||
| Trade Designation | Product Function | Max Use |
| Kleen MCT105 | Membrane Cleaner | NA |
| Kleen MCT405 | Membrane Cleaner | NA |
[1] This product is designed to be use off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[4] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
| Water Solutions Unlimited, Inc. | |
| 8824 Union Mills Drive | |
| Camby, IN 46113 | |
| United States | |
| 800-359-3570 | |
| 317-736-6868 |
Facility : Camby, IN
|
Citric Acid[1] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid 50%[2] | Membrane Cleaner | NA |
| WSU 50% Citric Acid[2] | Membrane Cleaner | NA |
[1] Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Water Tech, Inc. | |
| 7215 Highway 271 South | |
| Fort Smith, AR 72908 | |
| United States | |
| 800-488-7451 | |
| 479-649-7447 | |
| Visit this company's website |
Facility : Fort Smith, AR
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| WTM-CA50 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| WTM-SPE0560 | Membrane Cleaner | NA |
| WTM-SPE0561 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
Facility : McAlester, OK
|
Citric Acid[3] [4] |
||
| Trade Designation | Product Function | Max Use |
| WTM-CA50 | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[4] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[3] |
||
| Trade Designation | Product Function | Max Use |
| WTM-SPE0560 | Membrane Cleaner | NA |
| WTM-SPE0561 | Membrane Cleaner | NA |
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Water Tech. Inc. | |
| 7215 Hwy 271 S. | |
| Fort Smith, AR 72908 | |
| United States | |
| 800-488-7451 | |
| 479-649-7447 | |
| Visit this company's website |
Facility : # 1 USA
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| ProTex-RC-5050[1] | Membrane Cleaner | NA |
| ProTex-RC-5051[1] [2] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Wex Technologies Pvt. Ltd. | |
| Survey No. 244./2, Rajiv Gandhi | |
| Infotech Park, Phase-1, Hinjawadi | |
| Pune 411057, Landmark: Near Sai | |
| Service Station, | |
| India | |
| 91 206 6547000 | |
| Visit this company's website |
Facility : Maharashtra, India
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Genesol 38[2] [3] | Membrane Cleaner | NA |
| Genesol 40[2] [3] | Membrane Cleaner | NA |
| Genesol 703[2] [3] | Membrane Cleaner | NA |
| Genesol 704[2] [3] | Membrane Cleaner | NA |
| Genesol 721[2] [3] | Membrane Cleaner | NA |
| Genesol 80[2] | Membrane Cleaner | NA |
| Genesol UF Fe[2] | Membrane Cleaner | NA |
| Opticlean B[2] | Membrane Cleaner | NA |
[1] Certified for addition to the feedwater for evaporative desalination units only.
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Wilhelmsen Chemicals AS | ![]() |
| Kirkeveien 578, Kjøpmannskjær | |
| P.O. Box 15 | |
| NO-3141 Kjøpmannskjaer | |
| Norway | |
| 47 33 35 15 00 | |
| Visit this company's website |
Facility : Kjøpmannskjaer, Norway
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| RO Mild Acid Cleaner[2] [3] | Membrane Cleaner | NA |
| RO Surfactant Cleaner[2] | Membrane Cleaner | NA |
[1] Certified for addition to the feedwater for evaporative desalination units only.
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
Number of matching Manufacturers is 102
Number of matching Products is 976
Processing time was 1 seconds








