NSF Product and Service Listings
These NSF Official Listings are current as of Saturday, December 13, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=02460&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| PPG Protective and Marine Coatings | |
| 11605 Vimy Ridge Road | |
| Alexander, AR 72002 | |
| United States | |
| 501-235-9148 |
Facility : Alexander, AR
Protective (Barrier) Materials
| Water | Water | |||
| Water Contact | Contact | Contact | ||
| Trade Designation | Size Restriction | Temp | Material | |
|
Coatings - Fittings |
||||
| Amercoat 133[1] | >= 4" | CLD 23 | EPOXY | |
[1] Colors: Oxide red, white
Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 6 per coat; 10 total
Recoat Cure Time and Temperature: 24 hours at 75°F
Final Cure and Temperature: 14 days at 75°F
Special Comments: Mix ratio of resin to cure is 4:1 by volume. Mix for 5 minutes, let
stand for 10 minutes, then remix for 2-3 minutes before application. Scrape the sides of
the can while mixing.
|
||||
|
Coatings - Pipe |
||||
| Amercoat 133[1] | >= 30" | CLD 23 | EPOXY | |
| Amerlock 2[2] | >= 48" | CLD 23 | EPOXY | |
| Novaguard 810[3] | [4] | CLD 23 | EPOXY | |
| Novaguard 810ER[3] | [4] | CLD 23 | EPOXY | |
| Novaguard 840[5] | >= 42" | CLD 23 | EPOXY | |
[1] Colors: Oxide red, white
Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 6 per coat; 10 total
Recoat Cure Time and Temperature: 24 hours at 75°F
Final Cure and Temperature: 14 days at 75°F
Special Comments: Mix ratio of resin to cure is 4:1 by volume. Mix for 5 minutes, let
stand for 10 minutes, then remix for 2-3 minutes before application. Scrape the sides of
the can while mixing.
[2] Colors: Ivory, White, Medium Gray, RT-1805 Blue, Oxide Red, Black
Number of Coats: 2-4
Sequence of Coats: Any combination of listed colors
Maximum Field Use Dry Thickness: 8 mils per coat; 18 mils total
Maximum Thinner: 12% Amercoat #8 by volume (optional use is limited to tanks >= 250,000
gallons)
Recoat Cure Time and Temperature: 24 hours at 72° F
Final Cure Time/Temperature: 10 days at 72° F for all end uses except tank >= 250,000
gallons which has a final cure of 7 days at 72° F
Special Comments: Mix ratio of Base:Cure is 1:1 by volume or 1.1:1 by weight. Use of
Amercoat #8 Thinner is limited to tanks of 250,000 gallons or greater.
Final Cure Temp: 10 days at 72° F for all end uses without thinner; 7 days at 72° F for
tanks >= 250,000 gallons with Amercoat #8 thinner
[3] Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 30
Recoat Cure Time and Temperature: 24 hours at 70°F
Final Cure Time and Temperature: See Listing Note.
[4] Certified for tanks >= 500 gallons, pipe >=22", and valves >=2" with a final cure of 72
hours @ 77º F and tanks >= 250,000 gallons and valves >= 3/4" with a final cure of 10
days at 40º F.
[5] Colors: Cream, Green
Number of Coats: 1-2
Maximum field use dry film thickness (in mils): 30
Recoat cure time and temperature: 24 hours at 70°F
Final cure time and temperature: 72 hours at 70°F
Special Comments: Mix ratio of base to hardener is 4:1 by volume
|
||||
|
Coatings - Pump |
||||
| Amerlock 2[2] | >= 4" | CLD 23 | EPOXY | |
[2] Colors: Ivory, White, Medium Gray, RT-1805 Blue, Oxide Red, Black
Number of Coats: 2-4
Sequence of Coats: Any combination of listed colors
Maximum Field Use Dry Thickness: 8 mils per coat; 18 mils total
Maximum Thinner: 12% Amercoat #8 by volume (optional use is limited to tanks >= 250,000
gallons)
Recoat Cure Time and Temperature: 24 hours at 72° F
Final Cure Time/Temperature: 10 days at 72° F for all end uses except tank >= 250,000
gallons which has a final cure of 7 days at 72° F
Special Comments: Mix ratio of Base:Cure is 1:1 by volume or 1.1:1 by weight. Use of
Amercoat #8 Thinner is limited to tanks of 250,000 gallons or greater.
Final Cure Temp: 10 days at 72° F for all end uses without thinner; 7 days at 72° F for
tanks >= 250,000 gallons with Amercoat #8 thinner
|
||||
|
Coatings - Tank |
||||
| Amercoat 133[1] | >= 50 gal. | CLD 23 | EPOXY | |
| Amerlock 2[2] | >= 40,000 gal. | CLD 23 | EPOXY | |
| Amercoat 68HS[6] | >= 5000 gal. | CLD 23 | EPOXY | |
| Amercoat 68PW[6] | >= 5,000 gal | CLD 23 | EPOXY | |
| Novaguard 810[3] | [4] | CLD 23 | EPOXY | |
| Novaguard 810ER[3] | [4] | CLD 23 | EPOXY | |
| Novaguard 840[5] | >= 3,000 gal. | CLD 23 | EPOXY | |
[1] Colors: Oxide red, white
Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 6 per coat; 10 total
Recoat Cure Time and Temperature: 24 hours at 75°F
Final Cure and Temperature: 14 days at 75°F
Special Comments: Mix ratio of resin to cure is 4:1 by volume. Mix for 5 minutes, let
stand for 10 minutes, then remix for 2-3 minutes before application. Scrape the sides of
the can while mixing.
[2] Colors: Ivory, White, Medium Gray, RT-1805 Blue, Oxide Red, Black
Number of Coats: 2-4
Sequence of Coats: Any combination of listed colors
Maximum Field Use Dry Thickness: 8 mils per coat; 18 mils total
Maximum Thinner: 12% Amercoat #8 by volume (optional use is limited to tanks >= 250,000
gallons)
Recoat Cure Time and Temperature: 24 hours at 72° F
Final Cure Time/Temperature: 10 days at 72° F for all end uses except tank >= 250,000
gallons which has a final cure of 7 days at 72° F
Special Comments: Mix ratio of Base:Cure is 1:1 by volume or 1.1:1 by weight. Use of
Amercoat #8 Thinner is limited to tanks of 250,000 gallons or greater.
Final Cure Temp: 10 days at 72° F for all end uses without thinner; 7 days at 72° F for
tanks >= 250,000 gallons with Amercoat #8 thinner
[3] Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 30
Recoat Cure Time and Temperature: 24 hours at 70°F
Final Cure Time and Temperature: See Listing Note.
[4] Certified for tanks >= 500 gallons, pipe >=22", and valves >=2" with a final cure of 72
hours @ 77º F and tanks >= 250,000 gallons and valves >= 3/4" with a final cure of 10
days at 40º F.
[5] Colors: Cream, Green
Number of Coats: 1-2
Maximum field use dry film thickness (in mils): 30
Recoat cure time and temperature: 24 hours at 70°F
Final cure time and temperature: 72 hours at 70°F
Special Comments: Mix ratio of base to hardener is 4:1 by volume
[6] Colors: Reddish Gray, Green
Number of coats: 1
Sequence of coats: Primer
Maximum field use dry film thickness: 4 mils
Maximum thinner: 6% Amercoat 65
Final Cure Time and temperature: 8 hours at 75°F
Special comments: Mix ratio is 3.02:1.00:13.01 (Part A:PartB:Powder) by weight. Any
certified PPG top coat may be used provided both primer and topcoat meet their
individual Certified end uses.
|
||||
|
Coatings - Valve |
||||
| Amercoat 133[1] | >= 4" | CLD 23 | EPOXY | |
| Amerlock 2[2] | >= 6" | CLD 23 | EPOXY | |
| Amercoat 370[7] | >= 4" | CLD 23 | EPOXY | |
| Amerlock 400[8] | >= 6" | CLD 23 | EPOXY | |
| Novaguard 810[3] | [4] | CLD 23 | EPOXY | |
| Novaguard 810ER[3] | [4] | CLD 23 | EPOXY | |
| Novaguard 840[5] | >= 4" | CLD 23 | EPOXY | |
[1] Colors: Oxide red, white
Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 6 per coat; 10 total
Recoat Cure Time and Temperature: 24 hours at 75°F
Final Cure and Temperature: 14 days at 75°F
Special Comments: Mix ratio of resin to cure is 4:1 by volume. Mix for 5 minutes, let
stand for 10 minutes, then remix for 2-3 minutes before application. Scrape the sides of
the can while mixing.
[2] Colors: Ivory, White, Medium Gray, RT-1805 Blue, Oxide Red, Black
Number of Coats: 2-4
Sequence of Coats: Any combination of listed colors
Maximum Field Use Dry Thickness: 8 mils per coat; 18 mils total
Maximum Thinner: 12% Amercoat #8 by volume (optional use is limited to tanks >= 250,000
gallons)
Recoat Cure Time and Temperature: 24 hours at 72° F
Final Cure Time/Temperature: 10 days at 72° F for all end uses except tank >= 250,000
gallons which has a final cure of 7 days at 72° F
Special Comments: Mix ratio of Base:Cure is 1:1 by volume or 1.1:1 by weight. Use of
Amercoat #8 Thinner is limited to tanks of 250,000 gallons or greater.
Final Cure Temp: 10 days at 72° F for all end uses without thinner; 7 days at 72° F for
tanks >= 250,000 gallons with Amercoat #8 thinner
[3] Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 30
Recoat Cure Time and Temperature: 24 hours at 70°F
Final Cure Time and Temperature: See Listing Note.
[4] Certified for tanks >= 500 gallons, pipe >=22", and valves >=2" with a final cure of 72
hours @ 77º F and tanks >= 250,000 gallons and valves >= 3/4" with a final cure of 10
days at 40º F.
[5] Colors: Cream, Green
Number of Coats: 1-2
Maximum field use dry film thickness (in mils): 30
Recoat cure time and temperature: 24 hours at 70°F
Final cure time and temperature: 72 hours at 70°F
Special Comments: Mix ratio of base to hardener is 4:1 by volume
[7] Colors: Black, light buff, oxide red, milliken blue, white
Number of Coats: 2-4
Maximum Field Use Dry Film Thickness (in mils): 24
Maximum Thinner: 12.5% Amercoat #65 Thinner
Recoat Cure Time and Temperature: 0.5 hours at 23°C
Final Cure Time and Temperature: 7 days at 23°C
Special Comments: Mix ratio of base:cure is 4:1 by volume.
[8] Colors: Ivory, medium gray, oxide red, RT-1805, white
Number of Coats: 2-4
Sequence of Coats: Any combination of Listed colors
Maximum Field Use Dry Film Thickness (in mils): 6 per coat; 18 total
Maximum Thinner: 12.5% Amercoat #65 by volume
Recoat Cure Time and Temperature: 24 hours at 75°F
Final Cure Time and Temperature: 7 days at 75°F
Special Comments: Mix ratio of base:cure is 1:1 by volume.
|
||||
|
Primers[9] [10] |
||||
| Sigmaweld 199 US | >= 900 gal. | CLD 23 | ZINC | |
[9] This primer may be used with any Certified PPG topcoat provided both primer and topcoat
meet their individual Certified end uses.
[10] Colors: Tan
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 1
Maximum Thinner: None
Recoat Cure Time and Temperature: Not Applicable
Final Cure Time and Temperature: Primer (cure before application of topcoat) - 7 days at
ambient temperature (20°C)
Special Comments: Mix ratio of binder:paste is 2:1 by volume. Apply to steel substrate.
|
||||
Number of matching Manufacturers is 1