NSF Product and Service Listings

These NSF Official Listings are current as of Friday, December 26, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=03400&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
Solventum Purification Inc. 
2510 Conway Ave.
St. Paul, MN 55144 
United States 
800-222-7880 
651 737 1374
Visit this company's website


Facility : Stafford Springs, CT

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Filtration Devices/Components [G]
Betafine XL(LC)PP(GC)(EMC)(OR)[1] [2] 2.5" CLD 23 MLTPL
Betapure NT(LC)T(GC)(P)(SRO)(EMC)(OR)[3] [4] 2.65" CLD 23 MLTPL
DF Series DFGxxxPPYZ[5] [6] [7] 2.69" CLD 23 MLTPL

[1] Betafine XL, Betafatine XL (LC)PP(GC)(EMC)(OR) variable key:
    
    LC: Length 
    9 to 40 inches
    
    GC: Grade
    002 - 0.2 MICRON
    005 - 0.5 MICRON
    010 - 1 MICRON
    025 - 2.5 MICRON
    050 - 5 MICRON
    100 - 10 MICRON
    200 - 20 MICRON
    400 - 40 MICRON
    700 - 70 MICRON
    
    EMC: End Modification
    B0 - 226 O'RINGS & SPEAR, NO REINFORCING RING
    B1 - 226 O'RINGS & SPEAR, POLYSULFONE RING
    B2 - 226 O'RINGS & SPEAR, STAINLESS STEEL RING
    C0 - 222 O'RINGS & SPEAR, NO REINFORCING RING
    C1 - 222 O'RINGS & SPEAR, POLYSULFONE RING
    C2 - 222 O'RINGS & SPEAR, STAINLESS STEEL RING
    D - DOUBLE OPEN END, FLAT GASKET
    F0 - 222 O'RING'S & FLAT CAP, NO REINFORCING RING
    F1 - 222 O'RINGS & FLAT CAP, POLYSULFONE RING
    F2 - 222 O'RINGS & FLAT CAP, STAINLESS STEEL RING
    R - END CAP WITH SPRING
    
    OR: O-ring:
    A - SILICONE
    M - EPDM
[2] Betafine XL products require a per-service flush at a flow rate of 2 to 3 gpm (gallons
    per minute) per each 10" of length for 5 minutes with deionized water.
    Betafine XL products are certified for a minimum daily filtrate generation of 1440
    gallons.
[3] Betapure NT-T, BetaPure NT (LC)T(GC)(P)(EMC)(OR) variable key:
    
    LC: Length
    5 to 40 inches
    
    GC: Grade designation
    005 - 0.5 µm
    010 - 1 µm
    020 - 2 µm
    030 - 3 µm
    050 - 5 µm
    100 - 10 µm
    200 - 20 µm
    300 - 30 µm
    400 - 40 µm
    500 - 50 µm
    700 - 70 µm
    
    P: Packaging option
    B - Bulk 
    S - Standard
    Z - Individual 
    
    EMC: End Modification
    B - SOE, 226, O-rings / spear
    C - SOE, 222 O-rings / spear
    D - DOE, flat gaskets
    F - SOE, 222 O-rings / Flat Cap
    L - Film sealed for use in CTG Klean
    M - SOE, 222 O-rings / flat cap, for 1ZMP HSG
    Y - SOE, 222 single O-ring and cap
    
    OR: Gasket/O-ring material
    A - Silicone
    M - EPDM
[4]  Betapure NT-T, BetaPure NT (LC)T(GC)(P)(EMC)(OR) is certified for a minimum daily
    filtration generation of 1440 gallons per 10" of length.
    
    Betapure NT-T, BetaPure NT (LC)T(GC)(P)(EMC)(OR) requires a per-service flush at 2 to 3
    gallons per minute (gpm) per 10" of length for 5 minutes.
[5] DF Series DFGxxxPPYZ size 1 requires a pre-service flush at 10 gallons per minute (gpm)
    for 5 minutes with deionized water.
    
    DF Series DFGxxxPPYZ size 2 requires a pre-service flush at 10 gallons per minute (gpm)
    for 10 minutes with deionized water.
[6] DF Series DFGxxxPPYZ size 1 is certified for a minimum daily filtrate generation of
    14,440 gallons.
    
    DF Series DFGxxxPPYZ size 2 is certified for a minimum daily filtrate generation of
    28,800 gallons.
[7] DF Series DFGxxxPPYZ variable key:
    
    xxx: Micron rating
    001 - 1 µm
    005 - 5 µm
    010 - 10 µm
    025 - 25 µm
    050 - 50 µm
    100 - 100 µm
    200 - 200 µm
    
    Y: Cartridge length
    1 - 16"" nominal (1 high)
    2 - 32"" nominal (2 high)
    
    Z: Connection style
    C - Open-cuno standard
    R - Closed-competitor"
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.



Facility : Charlotte, NC

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Filtration Devices/Components [G]
Liqui-Cel™ EXF-10x28 Series Membrane Contactor, x40 membrane, FRP Vessel [1] 10" x 28" CLD 23 PP
Liqui-Cel™ EXF-10x28 Series Membrane Contactor, x40 membrane, SS Vessel[1] 10" x 28" CLD 23 PP
Liqui-Cel™ EXF-10x28 Series Membrane Contactor, x50 membrane, FRP Vessel[1] 10" x 28" CLD 23 PP
Liqui-Cel™ EXF-10x28 Series Membrane Contactor, x50 membrane, SS Vessel[1] 10" x 28" CLD 23 PP
Liqui-Cel™ EXF-14x28 Series Membrane Contactor, x40 membrane[2] 14" x 28" CLD 23 PP
Liqui-Cel™ EXF-14x28 Series Membrane Contactor, x50 membrane[2] 14" x 28" CLD 23 PP
Liqui-Cel™ EXF-14x40 Series Membrane Contactor, x40 membrane[2] 14" x 40" CLD 23 PP
Liqui-Cel™ EXF-14x40 Series Membrane Contactor, x50 membrane[2] 14" x 40" CLD 23 PP
Liqui-Cel™ EXF-4x28 Series Membrane Contactor, x50 membrane[3] 4" x 28" CLD 23 PP

[1] Trade name Liqui-Cel™ EXF-10x28 Series Membrane Contactor with x40 membrane fiber, FRP
    vessel is certified for a minimum daily flow of 60,000 gallons.
    
    Trade name Liqui-Cel™ EXF-10x28 Series Membrane Contactor with x50 membrane fiber, FRP
    vessel is certified for a minimum daily flow of 60,000 gallons.
    
    Trade name Liqui-Cel™ EXF-10x28 Series Membrane Contactor with x40 membrane fiber, SS
    vessel is certified for a minimum daily flow of 60,000 gallons.
    
    Trade name Liqui-Cel™ EXF-10x28 Series Membrane Contactor with x50 membrane fiber, SS
    vessel is certified for a minimum daily flow of 60,000 gallons.
[2] Trade name Liqui-Cel™ EXF-14x28 Series Membrane Contactor with x40 membrane fiber is
    certified for a minimum daily flow of 100,000 gallons.
    
    Trade name Liqui-Cel™ EXF-14x28 Series Membrane Contactor with x50 membrane fiber is
    certified for a minimum daily flow of 100,000 gallons.
    
    Trade name Liqui-Cel™ EXF-14x40 Series Membrane Contactor with x40 Membrane fiber  is
    certified for a minimum daily flow generation of 144,000 gallons.
    
    Trade name Liqui-Cel™ EXF-14x40 Series Membrane Contactor with x50 Membrane fiber is
    certified for a minimum daily flow generation of 144,000 gallons.
[3] Trade name Liqui-Cel™ EXF 4X28 Series Membrane Contactor with X50 Membrane Fiber is
    certified for a minimum daily flow generation of 5,760 gallons.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.



Facility : Itapetininga, Brazil

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Filtration Devices/Components [G]
Micro-Klean RT (LC)(GC)16(SC)(PC)(RC)(EMC)(OC)[1] [2] 2.5" CLD 23 MLTPL

[1] Micro-Klean RT, Micro-Klean RT (LC)(GC)16(SC)(PC(RC)(EMC)(OC) variable key:
    
    LC: Length
    10 to 40 inches
    
    GC: Grade Designation
    Y - 1 µm
    B - 5 µm
    C - 10 µm
    F - 25 µm
    L - 50 µm
    Q - 75 µm
    CSW - 2 µm
    
    SC: Surface
    G - Grooved
    U - Ungrooved
    
    PC: Package 
    2 - Bulk / Polybag
    3 - Polybag & Labeled
    4 - Polybag & Labeled (Latina)
    5 - Bulk / No Polybag
    
    RC: Ring Support
    0 - None
    1 - Polysulfone
    2 - Stainless steel
    
    EMC: End Modification
    B - 226 O-RING/SPEAR
    C - 222 O-RING/SPEAR
    F - 222 O-RING/FLAT CAP
    N - DOE
    P - POLYPRO CORE EXTENDER
    R - CAP WITH SPRING
    
    OC: Gasket Material
    A - Silicone
    E - EPDM
[2] Micro-Klean RT, Micro-Klean RT (LC)(GC)16(SC)(PC(RC)(EMC)(OC) is certified for a minimum
    daily filtrate generation of 1440 gallons per 10"" of length.
    Micro-Klean RT, Micro-Klean RT (LC)(GC)16(SC)(PC(RC)(EMC)(OC) requires a pre-service
    flush at a flow rate of 2 to 3 gallons per minute (gpm) per 10"" of length for 5 minutes
    with deionized water.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.



Facility : Guangzhou, China

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Filtration Devices/Components [G]
High Flow Filter ElementHF-WW-PP-XXX-Y-Z[1] [2] [3] [4] 6.52" CLD 23 MLTPL
High Flow Series Filter HF-10-PP-0005-X-01[5] [6] 6.52" CLD 23 MLTPL
High Flow SeriesHFM-XX-YY-ZZZ-Q[1] [2] [3] [7] N/A CLD 23 MLTPL
Micro-Klean RT (LC)(GC)16(SC)(PC)(RC)(EMC)(OC)[8] [9] [10] 2.5" CLD 23 MLTPL

[1] 3M™ High Flow Series Filter Cartridges, HF-WW-PP-XXX-Y-Z is certified for a minimum
    daily filtrate generation of 21,600 gallons per 10"" of length.
[2] 3M™ High Flow Series Filter Cartridges, HF-WW-PP-XXX-Y-Z requires a pre-service flush at
    10 gallons per minute (gpm) per 10"" of length for 10 minutes with deionized water.
[3] Certified for a minimum flow rate of 65,000 L/day.
[4] WW = Length of cartridge (in inches) - 40 or 60 PP = Polypropylene XXX = Removal rating
    0005 - 0.5 micron 001 - 1 micron 002 - 2 micron 005 - 5 micron 010 - 10 micron 015 - 15
    micron 025 - 25 micron 040 - 40 micron 070 - 70 micron Y = End o-ring type A - Silicone
    B - Fluorocarbon C - EPR D - Nitrile Z - Packaging option (number of filters per box) 01
    - 1 pack 04 - 4 pack
[5] High Flow Series Filter HF-10-PP-0005-X-01 is certified to 50 gpm flow rate with a 3.9 L
    Unit Volume
    High Flow Series Filter HF-40-PP-0005-X-01 is certified to 200 gpm flow rate with a 15.4
    L Unit Volume
    High Flow Series Filter HF-60-PP-0005-X-01 is certified to 300 gpm flow rate with a 23.2
    L Unit Volume
[6] High Flow Series Filter HF-10-PP-0005-X-01 where
    X = C (EPR) or D (nitrile)
    High Flow Series Filter HF-40-PP-0005-X-01 where
    X = C (EPR) or D (nitrile)
    High Flow Series Filter HF-60-PP-0005-X-01 where
    X = C (EPR) or D (nitrile)
[7] XX: Length 10 - 10" nominal, 40 - 40" nominal 60 - 60" nominal. YY: Material PP -
    Polypropylene. ZZZ: Micron Grade N05=5 micron nominal, A05=5 micron absolute, A10=10
    micron absolute, A20=20 micron absolute. Q - End o-ring Type A - Silicone D - Nitrile.
    Size:
[8] Micro-Klean RT, Micro-Klean RT (LC)(GC)16(SC)(PC(RC)(EMC)(OC) requires a pre-service
    flush at a flow rate of 2 to 3 gallons per minute (gpm) per 10" of length for 5 minutes
    with deionized water.
[9] Micro-Klean RT, Micro-Klean RT (LC)(GC)16(SC)(PC(RC)(EMC)(OC) is certified for a minimum
    daily filtrate generation of 1440 gallons per 10" of length.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.
[10] LC denotes length (09, 10, 19, 20, 29, 30, 39, or 40); GC denotes micron rating (002,
     005, 010, 025, 050, 100, 200, 400, or 700); EMC denotes end treatment (B0, B1, B2, C0,
     C1, C2, D, F0, F1, or F2); OR denotes o-ring material (A, B, C, or D).



Facility : Wuppertal, Germany

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Filtration Devices/Components [G]
Liqui-Cel™ EXF-10x28 Series Membrane Contactor, x40 membrane, FRP Vessel[1] 10" x 28" CLD 23 PP
Liqui-Cel™ EXF-10x28 Series Membrane Contactor, x40 membrane, SS Vessel[1] 10" x 28" CLD 23 PP
Liqui-Cel™ EXF-10x28 Series Membrane Contactor, x50 membrane, FRP Vessel[1] 10" x 28" CLD 23 PP
Liqui-Cel™ EXF-10x28 Series Membrane Contactor, x50 membrane, SS Vessel[1] 10" x 28" CLD 23 PP
Liqui-Cel™ EXF-14x28 Series Membrane Contactor, x50 membrane[2] 14" x 28" CLD 23 PP
Liqui-Cel™ EXF-14x40 Series Membrane Contactor, x40 membrane[2] 14" x 40" CLD 23 PP
Liqui-Cel™ EXF-14x40 Series Membrane Contactor, x50 membrane[2] 14" x 40" CLD 23 PP

[1] Trade name Liqui-Cel™ EXF-10x28 Series Membrane Contactor with x40 membrane fiber, FRP
    vessel is certified for a minimum daily flow of 60,000 gallons.
    
    Trade name Liqui-Cel™ EXF-10x28 Series Membrane Contactor with x50 membrane fiber, FRP
    vessel is certified for a minimum daily flow of 60,000 gallons.
    
    Trade name Liqui-Cel™ EXF-10x28 Series Membrane Contactor with x40 membrane fiber, SS
    vessel is certified for a minimum daily flow of 60,000 gallons.
    
    Trade name Liqui-Cel™ EXF-10x28 Series Membrane Contactor with x50 membrane fiber, SS
    vessel is certified for a minimum daily flow of 60,000 gallons
[2] Trade name Liqui-Cel™ EXF-14x28 Series Membrane Contactor with x40 membrane fiber is
    certified for a minimum daily flow of 100,000 gallons.
    
    Trade name Liqui-Cel™ EXF-14x28 Series Membrane Contactor with x50 membrane fiber is
    certified for a minimum daily flow of 100,000 gallons.
    
    Trade name Liqui-Cel™ EXF-14x40 Series Membrane Contactor with x40 Membrane fiber is
    certified for a minimum daily flow of 144,000 gallons.
    
    Trade name Liqui-Cel™ EXF-14x40 Series Membrane Contactor with x50 Membrane fiber is
    certified for a minimum daily flow of 144,000 gallons.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.



Facility : Nuevo Leon, Mexico

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Filtration Devices/Components [G]
3M™ 740 Series Filter Cartridges, 740-Q-RR-SS-XXX-Y-Z[1] [2] [3] 6.52" CLD 23 MLTPL
High Flow Filter ElementHF-WW-PP-XXX-Y-Z[4] [5] N/A CLD 23 MLTPL
High Flow SeriesHFM-XX-YY-ZZZ-Q[4] [6] N/A CLD 23 MLTPL
Micro-Klean RT (LC)(GC)16(SC)(PC)(RC)(EMC)(OC)[7] [8] [9] 2.5" CLD 23 MLTPL
Micro-Klean RW (XX)(X17)(A)(B)0(C)(D)[10] [11] 2.5" CLD 23 MLTPL

[1] 3M™ High Flow HFM Series Filter Cartridges, 740-Q-RR-SS-XXX-Y-Z 30"" requires a
    pre-service flush at 10 gallons per minute (GPM) for 10 minutes.
    
    3M™ High Flow HFM Series Filter Cartridges, 740-Q-RR-SS-XXX-Y-Z 40"" requires a
    pre-service flush at 10 gallons per minute (GPM) for 15 minutes.
[2] 3M™ High Flow HFM Series Filter Cartridges, 740-Q-RR-SS-XXX-Y-Z variable key:
    
    Q: Construction
    B - Standard
    K - Reduced filter area
    
    RR: Length
    30 - 30 nominal
    40 - 40 nominal
    
    SS: Material
    PP - Polypropylene
    EE - Polyester
    
    XXX: Micron rating:
    001 = 1 um
    002 = 2 um
    005 = 5 um
    010 = 10 um
    015 = 15 um
    
    Y: Gasket material
    A - Silicone
    C - EPDM
    
    Z: Packaging
    1 - 1/case
    2 - 30/case
    3 - 37/case
[3] 3M™ High Flow HFM Series Filter Cartridges, 740-Q-RR-SS-XXX-Y-Z is certified for a
    minimum daily filtrate generation of 27,000 gallons per 30" of length.
[4] 3M™ High Flow Series Filter Cartridges, HF-WW-PP-XXX-Y-Z & 3M™ High Flow HFM Series
    Filter Cartridges, HFM-XX-YY-ZZZ-Q are certified for a minimum daily filtrate generation
    of 21,600 gallons per 10"" of length.
    
    3M™ High Flow Series Filter Cartridges, HF-WW-PP-XXX-Y-Z  & 3M™ High Flow HFM Series
    Filter Cartridges, HFM-XX-YY-ZZZ-Q requires a pre-service flush at 10 gallons per minute
    (gpm) per 10"" of length for 10 minutes with deionized water.
[5] 3M™ High Flow Series Filter Cartridges, HF-WW-PP-XXX-Y-Z variable key:
    
    WW: Length
    10 - 10"" nominal
    40 - 40"" nominal
    60 - 60"" nominal
    
    XXX: Grade
    001 - 1 um
    002 - 2 um
    005 - 5 um
    010 - 10 um
    015 - 15 um
    025 - 25 um
    040 - 40 um
    070 - 70 um
    
    Y: O-ring material
    A: Silicone
    B: Fluorocarbon
    C: EPR
    D: Nitrile
    
    Z: Packaged quantity
    01 - single pack
[6] 3M™ High Flow HFM Series Filter Cartridges, HFM-XX-YY-ZZZ-Q key:
    
    XX: Length
    10 - 10"" nominal
    40 - 40"" nominal
    60 - 60"" nominal
    
    YY: Construction
    PP - Polypropylene
    
    ZZZ: Grade
    N05 - 5 micron nominal (70 micron absolute)
    A05 - 5 micron absolute
    A10 - 10 micron absolute
    A20 - 20 micron absolute
    A40 - 40 micron absolute
[7] LC: Length
    10 to 40 inches
    
    GC: Grade Designation
    Y - 1 µm
    B - 5 µm
    C - 10 µm
    F - 25 µm
    L - 50 µm
    Q - 75 µm
    CSW - 2 µm
    
    SC: Surface
    G - Grooved
    U - Ungrooved
    
    PC: Package 
    2 - Bulk / Polybag
    3 - Polybag & Labeled
    4 - Polybag & Labeled (Latina)
    5 - Bulk / No Polybag
    
    RC: Ring Support
    0 - None
    1 - Polysulfone
    2 - Stainless steel
    
    EMC: End Modification
    B - 226 O-RING/SPEAR
    C - 222 O-RING/SPEAR
    F - 222 O-RING/FLAT CAP
    N - DOE
    P - POLYPRO CORE EXTENDER
    R - CAP WITH SPRING
    
    OC: Gasket Material
    A - Silicone
    E - EPDM
[8] Micro-Klean RT, Micro-Klean RT (LC)(GC)16(SC)(PC(RC)(EMC)(OC) is certified for a minimum
    daily filtrate generation of 1440 gallons per 10"" of length.
[9] Micro-Klean RT, Micro-Klean RT (LC)(GC)16(SC)(PC(RC)(EMC)(OC) requires a pre-service
    flush at a flow rate of 2 to 3 gallons per minute (gpm) per 10" of length for 5 minutes
    with deionized water.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.
[10] Micro-Klean RW, Micro-Klean RW(XX)(X17)(A)(B)0(C)(D) variable key:
     
     XX: Length
     10 to 40 inches
     
     X: Grade Designation
     Y - 1 µm
     B - 5 µm
     
     A: Surface
     G - Grooved
     
     B: Package
     2 - Bulk / Polybag
     
     C: End Modification
     C- 222 O-RING/SPEAR
     F - 222 O-RING/FLAT CAP
     N - DOE
     1 - 222 O-RING/ PLASTIC SPRING
     R - PLASTIC SPRING
     
     D: Gasket
     A - Silicone
     N - None
[11] Micro-Klean RW, Micro-Klean RW(XX)(X17)(A)(B)0(C)(D) is certified for a minimum daily
     filtrate generation of 1440 gallons per 10"" of length.
     
     Micro-Klean RW, Micro-Klean RW(XX)(X17)(A)(B)0(C)(D) requires a pre-service flush at a
     flow rate of 2 to 3 gallons per minute (gpm) per 10"" of length for 5 minutes with
     deionized water.



Facility : Wroclaw, Poland

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Filtration Devices/Components [G]
Micro-Klean RT (LC)(GC)16(SC)(PC)(RC)(EMC)(OC)[1] [2] 2.5" CLD 23 MLTPL

[1] Micro-Klean RT, Micro-Klean RT (LC)(GC)16(SC)(PC(RC)(EMC)(OC) variable key:
    
    LC: Length
    10 to 40 inches
    
    GC: Grade Designation
    Y - 1 µm
    B - 5 µm
    C - 10 µm
    F - 25 µm
    L - 50 µm
    Q - 75 µm
    CSW - 2 µm
    
    SC: Surface
    G - Grooved
    U - Ungrooved
    
    PC: Package 
    2 - Bulk / Polybag
    3 - Polybag & Labeled
    4 - Polybag & Labeled (Latina)
    5 - Bulk / No Polybag
    
    RC: Ring Support
    0 - None
    1 - Polysulfone
    2 - Stainless steel
    
    EMC: End Modification
    B - 226 O-RING/SPEAR
    C - 222 O-RING/SPEAR
    F - 222 O-RING/FLAT CAP
    N - DOE
    P - POLYPRO CORE EXTENDER
    R - CAP WITH SPRING
    
    OC: Gasket Material
    A - Silicone
    E - EPDM
[2] Micro-Klean RT, Micro-Klean RT (LC)(GC)16(SC)(PC(RC)(EMC)(OC) is certified for a minimum
    daily filtrate generation of 1440 gallons per 10" of length.
    
    Micro-Klean RT, Micro-Klean RT (LC)(GC)16(SC)(PC(RC)(EMC)(OC) requires a pre-service
    flush at a flow rate of 2 to 3 gallons per minute (gpm) per 10" of length for 5 minutes
    with deionized water.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Number of matching Manufacturers is 1
Number of matching Products is 30
Processing time was 0 seconds