NSF Product and Service Listings
These NSF Official Listings are current as of Saturday, November 15, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=0D490&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| Sherwin-Williams | |
| 1101 South Third Street | |
| Minneapolis, MN 55415 | |
| United States | |
| 817-640-0848 |
Facility : Covington, GA
Protective (Barrier) Materials
| Water | Water | |||
| Water Contact | Contact | Contact | ||
| Trade Designation | Size Restriction | Temp | Material | |
|
Coatings - Fittings |
||||
| 704G.F Pipeclad Blue Green ID Fast Gel Pipe Coating[6] | >=2 in | D. HOT | PEC | |
| IF-5817P Blue Epoxy[1] [2] | >=2” | C. HOT | PEC | |
| IF1947M[2] [3] | >= 2" | C. HOT | PEC | |
| IF1947MP[2] [3] | >= 2" | C. HOT | PEC | |
| IF1947T[2] [3] | >= 2" | C. HOT | PEC | |
| IF5817B[4] | >= 2" | C. HOT | PEC | |
| IF7393T[2] [3] | >= 2" | C. HOT | PEC | |
| IF9902[2] [5] | >= 2” | C. HOT | PEC | |
| PEA80008[2] [3] | >= 2" | C. HOT | PEC | |
| PER80003[2] [3] | >= 2" | C. HOT | PEC | |
| PEY80004[2] [3] | >= 2" | C. HOT | PEC | |
| PEY80005[2] [3] | >= 2" | C. HOT | PEC | |
| PEY80008[2] [3] | >= 2" | C. HOT | PEC | |
| Pipeclad 704G Blue Green ID Pipe Coating [6] | >= 2” | D. HOT | PEC | |
[1] Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 30
Maximum Thinner: None
Final Cure Time/Temperature: Final cure is 15 minutes at 375F
[2] Sold in two alternate grind sizes (T and F) and two alternate package sizes (D and L).
The Listing applies to all grind sizes and package size designations.
[3] Colors: Red, Black, Graphite, Safety Yellow, Yellow, Romac Yellow
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 20
Maximum Thinner: None
Final Cure Time and Temperature: 15 minutes at 375°F
[4] Colors: RAL5003 Blue
Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 40
Final Cure Time/Temperature: 12 minutes at 380F
Special Comments: Steel or ductile iron substrates. Grit blasting on sides to be coated
per SSPC SP10/NACE No.2. Preheat part at 380F for at least 30 min before powder
application: electrostatic spray.
[5] Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 8
Final Cure Time/Temperature: 15 minutes at 400F
[6] Colors: Blue Green
Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 60 mils
Final Cure Time/Temperature: 12 minutes at 450F
Special Comments: Fluidized Bed Application for applications of 10-60 mils: preheat
steel substrate to 450F, dip in fluidized bed for 3-5 seconds; Electrostatic spray for
applications of 10-18 mils: Preheat steel substrate to 450F before powder application.
|
||||
|
Coatings - Pipe |
||||
| 704G.F Pipeclad Blue Green ID Fast Gel Pipe Coating[6] | >=2 in | D. HOT | PEC | |
| IF-5817P Blue Epoxy[1] [2] | >=2” | C. HOT | PEC | |
| IF1947M[2] [3] | >= 2" | C. HOT | PEC | |
| IF1947MP[2] [3] | >= 2" | C. HOT | PEC | |
| IF1947T[2] [3] | >= 2" | C. HOT | PEC | |
| IF5817B[4] | >= 2" | C. HOT | PEC | |
| IF7393T[2] [3] | >= 2" | C. HOT | PEC | |
| IF9902[2] [5] | >= 2” | C. HOT | PEC | |
| PEA80008[2] [3] | >= 2" | C. HOT | PEC | |
| PER80003[2] [3] | >= 2" | C. HOT | PEC | |
| PEY80004[2] [3] | >= 2" | C. HOT | PEC | |
| PEY80005[2] [3] | >= 2" | C. HOT | PEC | |
| PEY80008[2] [3] | >= 2" | C. HOT | PEC | |
| Pipeclad 704G Blue Green ID Pipe Coating [6] | >= 2” | D. HOT | PEC | |
[1] Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 30
Maximum Thinner: None
Final Cure Time/Temperature: Final cure is 15 minutes at 375F
[2] Sold in two alternate grind sizes (T and F) and two alternate package sizes (D and L).
The Listing applies to all grind sizes and package size designations.
[3] Colors: Red, Black, Graphite, Safety Yellow, Yellow, Romac Yellow
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 20
Maximum Thinner: None
Final Cure Time and Temperature: 15 minutes at 375°F
[4] Colors: RAL5003 Blue
Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 40
Final Cure Time/Temperature: 12 minutes at 380F
Special Comments: Steel or ductile iron substrates. Grit blasting on sides to be coated
per SSPC SP10/NACE No.2. Preheat part at 380F for at least 30 min before powder
application: electrostatic spray.
[5] Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 8
Final Cure Time/Temperature: 15 minutes at 400F
[6] Colors: Blue Green
Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 60 mils
Final Cure Time/Temperature: 12 minutes at 450F
Special Comments: Fluidized Bed Application for applications of 10-60 mils: preheat
steel substrate to 450F, dip in fluidized bed for 3-5 seconds; Electrostatic spray for
applications of 10-18 mils: Preheat steel substrate to 450F before powder application.
|
||||
|
Coatings - Tank |
||||
| IF-5817P Blue Epoxy[1] [2] | >=4 gal | C. HOT | PEC | |
| IF1947M[2] [3] | >= 4 gal. | C. HOT | PEC | |
| IF1947MP[2] [3] | >= 4 gal. | C. HOT | PEC | |
| IF1947T[2] [3] | >= 4 gal. | C. HOT | PEC | |
| IF5817B[4] | >= 4 gal. | C. HOT | PEC | |
| IF7393T[2] [3] | >= 4 gal. | C. HOT | PEC | |
| IF9902[2] [5] | >= 4 gal | C. HOT | PEC | |
| PEA80008[2] [3] | >= 4 gal. | C. HOT | PEC | |
| PER80003[2] [3] | >= 4 gal. | C. HOT | PEC | |
| PEY80004[2] [3] | >= 4 gal. | C. HOT | PEC | |
| PEY80005[2] [3] | >= 4 gal. | C. HOT | PEC | |
[1] Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 30
Maximum Thinner: None
Final Cure Time/Temperature: Final cure is 15 minutes at 375F
[2] Sold in two alternate grind sizes (T and F) and two alternate package sizes (D and L).
The Listing applies to all grind sizes and package size designations.
[3] Colors: Red, Black, Graphite, Safety Yellow, Yellow, Romac Yellow
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 20
Maximum Thinner: None
Final Cure Time and Temperature: 15 minutes at 375°F
[4] Colors: RAL5003 Blue
Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 40
Final Cure Time/Temperature: 12 minutes at 380F
Special Comments: Steel or ductile iron substrates. Grit blasting on sides to be coated
per SSPC SP10/NACE No.2. Preheat part at 380F for at least 30 min before powder
application: electrostatic spray.
[5] Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 8
Final Cure Time/Temperature: 15 minutes at 400F
|
||||
|
Coatings - Valve |
||||
| 704G.F Pipeclad Blue Green ID Fast Gel Pipe Coating | >=2 in | D. HOT | PEC | |
| IF-5817P Blue Epoxy[1] [2] | >=2” | C. HOT | PEC | |
| IF1947M[2] [3] | >= 2" | C. HOT | PEC | |
| IF1947MP[2] [3] | >= 2" | C. HOT | PEC | |
| IF1947T[2] [3] | >= 2" | C. HOT | PEC | |
| IF5817B[4] | >= 2" | C. HOT | PEC | |
| IF7393T[2] [3] | >= 2" | C. HOT | PEC | |
| IF9902[2] [5] | >= 2” | C. HOT | PEC | |
| PEA80008[2] [3] | >= 2" | C. HOT | PEC | |
| PER80003[2] [3] | >= 2" | C. HOT | PEC | |
| PEY80004[2] [3] | >= 2" | C. HOT | PEC | |
| PEY80005[2] [3] | >= 2" | C. HOT | PEC | |
| PEY80008[2] [3] | >= 2" | C. HOT | PEC | |
| Pipeclad 704G Blue Green ID Pipe Coating [6] | >= 2” | D. HOT | PEC | |
[1] Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 30
Maximum Thinner: None
Final Cure Time/Temperature: Final cure is 15 minutes at 375F
[2] Sold in two alternate grind sizes (T and F) and two alternate package sizes (D and L).
The Listing applies to all grind sizes and package size designations.
[3] Colors: Red, Black, Graphite, Safety Yellow, Yellow, Romac Yellow
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 20
Maximum Thinner: None
Final Cure Time and Temperature: 15 minutes at 375°F
[4] Colors: RAL5003 Blue
Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 40
Final Cure Time/Temperature: 12 minutes at 380F
Special Comments: Steel or ductile iron substrates. Grit blasting on sides to be coated
per SSPC SP10/NACE No.2. Preheat part at 380F for at least 30 min before powder
application: electrostatic spray.
[5] Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 8
Final Cure Time/Temperature: 15 minutes at 400F
[6] Colors: Blue Green
Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 60 mils
Final Cure Time/Temperature: 12 minutes at 450F
Special Comments: Fluidized Bed Application for applications of 10-60 mils: preheat
steel substrate to 450F, dip in fluidized bed for 3-5 seconds; Electrostatic spray for
applications of 10-18 mils: Preheat steel substrate to 450F before powder application.
|
||||
Facility : Charlotte, NC
Protective (Barrier) Materials
| Water | Water | |||
| Water Contact | Contact | Contact | ||
| Trade Designation | Size Restriction | Temp | Material | |
|
Coatings - Fittings |
||||
| 704G.F Pipeclad Blue Green ID Fast Gel Pipe Coating[3] | >=2 in | D. HOT | PEC | |
| IF1947M Red Oxide Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| IF1947MP Red Iron Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| IF1947N Red Oxide Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| IF1947T Red Oxide Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| IF7393T Black Oxide Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| PEA80008 Graphite Primer[1] [2] | >= 2" | C. HOT | PEC | |
| PER80003 Red Primer[1] [2] | >= 2" | C. HOT | PEC | |
| PEY80004 Safety Yellow Primer[1] [2] | >= 2" | C. HOT | PEC | |
| PEY80005 Yellow Primer[1] [2] | >= 2" | C. HOT | PEC | |
| PEY80008 Romac Yellow Epoxy Coating[1] [2] | >= 2" | C. HOT | PEC | |
| Pipeclad 704G Blue Green ID Pipe Coating [3] | >= 2” | D. HOT | PEC | |
[1] Sold in two alternate grind sizes (T and F) and two alternate package sizes (D and L).
The Listing applies to all grind sizes and package size designations.
[2] Number of coats: 1
Maximum Field Use Dry Film Thickness (in mils): 20
Maximum Thinner: None
Final Cure Time and Temperature: 10 minutes at 375°F
[3] Colors: Blue Green
Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 60 mils
Final Cure Time/Temperature: 12 minutes at 450F
Special Comments: Substrate: Fluidized Bed Application for applications of 10-60 mils:
preheat steel substrate to 450F, dip in fluidized bed for 3-5 seconds; Electrostatic
spray for applications of 10-18 mils: Preheat steel substrate to 450F before powder
application.
|
||||
|
Coatings - Pipe |
||||
| 704G.F Pipeclad Blue Green ID Fast Gel Pipe Coating[3] | >= 2” | D. HOT | PEC | |
| IF1947M Red Oxide Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| IF1947MP Red Iron Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| IF1947N Red Oxide Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| IF1947T Red Oxide Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| IF7393T Black Oxide Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| PEA80008 Graphite Primer[1] [2] | >= 2" | C. HOT | PEC | |
| PER80003 Red Primer[1] [2] | >= 2" | C. HOT | PEC | |
| PEY80004 Safety Yellow Primer[1] [2] | >= 2" | C. HOT | PEC | |
| PEY80005 Yellow Primer[1] [2] | >= 2" | C. HOT | PEC | |
| Pipeclad 704G Blue Green ID Pipe Coating [3] | >= 2” | D. HOT | PEC | |
[1] Sold in two alternate grind sizes (T and F) and two alternate package sizes (D and L).
The Listing applies to all grind sizes and package size designations.
[2] Number of coats: 1
Maximum Field Use Dry Film Thickness (in mils): 20
Maximum Thinner: None
Final Cure Time and Temperature: 10 minutes at 375°F
[3] Colors: Blue Green
Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 60 mils
Final Cure Time/Temperature: 12 minutes at 450F
Special Comments: Substrate: Fluidized Bed Application for applications of 10-60 mils:
preheat steel substrate to 450F, dip in fluidized bed for 3-5 seconds; Electrostatic
spray for applications of 10-18 mils: Preheat steel substrate to 450F before powder
application.
|
||||
|
Coatings - Tank |
||||
| IF1947M Red Oxide Epoxy[1] [2] | >= 4 gal. | C. HOT | PEC | |
| IF1947MP Red Iron Epoxy[1] [2] | >= 4 gal. | C. HOT | PEC | |
| IF1947N Red Oxide Epoxy[1] [2] | >= 4 gal. | C. HOT | PEC | |
| IF1947T Red Oxide Epoxy[1] [2] | >= 4 gal. | C. HOT | PEC | |
| IF7393T Black Oxide Epoxy[1] [2] | >= 4 gal. | C. HOT | PEC | |
| PEA80008 Graphite Primer[1] [2] | >= 4 gal. | C. HOT | PEC | |
| PER80003 Red Primer[1] [2] | >= 4 gal. | C. HOT | PEC | |
| PEY80004 Safety Yellow Primer[1] [2] | >= 4 gal. | C. HOT | PEC | |
| PEY80005 Yellow Primer[1] [2] | >= 4 gal. | C. HOT | PEC | |
[1] Sold in two alternate grind sizes (T and F) and two alternate package sizes (D and L).
The Listing applies to all grind sizes and package size designations.
[2] Number of coats: 1
Maximum Field Use Dry Film Thickness (in mils): 20
Maximum Thinner: None
Final Cure Time and Temperature: 10 minutes at 375°F
|
||||
|
Coatings - Valve |
||||
| 704G.F Pipeclad Blue Green ID Fast Gel Pipe Coating | >= 2" | D. HOT | PEC | |
| IF1947M Red Oxide Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| IF1947MP Red Iron Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| IF1947N Red Oxide Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| IF1947T Red Oxide Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| IF7393T Black Oxide Epoxy[1] [2] | >= 2" | C. HOT | PEC | |
| PEA80008 Graphite Primer[1] [2] | >= 2" | C. HOT | PEC | |
| PER80003 Red Primer[1] [2] | >= 2" | C. HOT | PEC | |
| PEY80004 Safety Yellow Primer[1] [2] | >= 2" | C. HOT | PEC | |
| PEY80005 Yellow Primer[1] [2] | >= 2" | C. HOT | PEC | |
| PEY80008 Romac Yellow Epoxy Coating[1] [2] | >= 2" | C. HOT | PEC | |
| Pipeclad 704G Blue Green ID Pipe Coating [3] | >= 2” | D. HOT | PEC | |
[1] Sold in two alternate grind sizes (T and F) and two alternate package sizes (D and L).
The Listing applies to all grind sizes and package size designations.
[2] Number of coats: 1
Maximum Field Use Dry Film Thickness (in mils): 20
Maximum Thinner: None
Final Cure Time and Temperature: 10 minutes at 375°F
[3] Colors: Blue Green
Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 60 mils
Final Cure Time/Temperature: 12 minutes at 450F
Special Comments: Substrate: Fluidized Bed Application for applications of 10-60 mils:
preheat steel substrate to 450F, dip in fluidized bed for 3-5 seconds; Electrostatic
spray for applications of 10-18 mils: Preheat steel substrate to 450F before powder
application.
|
||||
Facility : Arlington, TX
Protective (Barrier) Materials
| Water | Water | |||
| Water Contact | Contact | Contact | ||
| Trade Designation | Size Restriction | Temp | Material | |
|
Coatings - Fittings |
||||
| EAS6-60008[2] [3] | >= 2" | C. HOT | PEC | |
| EAS8-70011[2] [3] | >= 2" | C. HOT | PEC | |
| EBS8-70003[2] [4] | >= 2" | CLD 23 | PEC | |
| ECS8-70027[2] [4] | >= 2" | CLD 23 | PEC | |
| EGS6-0M001 WATTS AM ZR Primer[1] | >= 2" | C. HOT | ZINC | |
| EGS8-70010[2] [4] | >= 2" | CLD 23 | PEC | |
| EHS8-70014[2] [4] | >= 2" | CLD 23 | PEC | |
| ELS6-60004[2] [3] | >= 2" | C. HOT | PEC | |
| ELS6-60005[2] [3] | >= 2" | C. HOT | PEC | |
| ELS8-70012[2] [4] | >= 2" | CLD 23 | PEC | |
| ELS8-80002[2] [4] | >= 2" | CLD 23 | PEC | |
| ELS8-80003[2] [4] | >= 2" | CLD 23 | PEC | |
| ERS8-70002[2] [4] | >= 2" | CLD 23 | PEC | |
| EWS8-70015[2] [4] | >= 2" | CLD 23 | PEC | |
| EWS8-70024[2] [4] | >= 2" | CLD 23 | PEC | |
| EWS8-80007[2] [4] | >= 2" | CLD 23 | PEC | |
[1] Color: Gray
Number of coats: 1
Maximum field use dry film thickness (in mils): 10 mils
Special comments: Required cure time is 20 min @ 300F or 10 min @ 400F
[2] The suffixes indicate the following container type:
C - Box
D - Drum
I - Overpack/international box
J - Sample jar
S - Super sack
T - Tote
The number following the letter indicates fill size in number of pounds per container.
[3] Colors: Blue, gray
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 20
Recoat Cure Time and Temperature: 10 minutes at 350°F
[4] Colors: Black oxide, blue, clear, green, off white, red oxide, tank tan, white
Number of Coats: 1
Sequence of Coats: N/A
Maximum Field Use Dry Film Thickness (in mils): 20
Maximum Thinner: N/A
Recoat Cure Time and Temperature: 10 minutes at 350°F
|
||||
|
Coatings - Pipe |
||||
| EAS6-60008[2] [3] | >= 2" | C. HOT | PEC | |
| EAS8-70011[2] [4] | >= 2" | C. HOT | PEC | |
| EBS8-70003[2] [4] | >= 2" | CLD 23 | PEC | |
| ECS8-70027[2] [4] | >= 2" | CLD 23 | PEC | |
| EGS6-0M001 WATTS AM ZR Primer[1] | >= 12" | D. HOT | ZINC | |
| EGS8-70010[2] [4] | >= 2" | CLD 23 | PEC | |
| EHS8-70014[2] [4] | >= 2" | CLD 23 | PEC | |
| ELS6-60004[2] [3] | >= 2" | C. HOT | PEC | |
| ELS6-60005[2] [3] | >= 2" | C. HOT | PEC | |
| ELS8-70012[2] [4] | >= 2" | CLD 23 | PEC | |
| ELS8-80002[2] [4] | >= 2" | CLD 23 | PEC | |
| ELS8-80003[2] [4] | >= 2" | CLD 23 | PEC | |
| ERS8-70002[2] [4] | >= 2" | CLD 23 | PEC | |
| EWS8-70015[2] [4] | >= 2" | CLD 23 | PEC | |
| EWS8-70024[2] [4] | >= 2" | CLD 23 | PEC | |
| EWS8-80007[2] [4] | >= 2" | CLD 23 | PEC | |
[1] Color: Gray
Number of coats: 1
Maximum field use dry film thickness (in mils): 10 mils
Special comments: Required cure time is 20 min @ 300F or 10 min @ 400F
[2] The suffixes indicate the following container type:
C - Box
D - Drum
I - Overpack/international box
J - Sample jar
S - Super sack
T - Tote
The number following the letter indicates fill size in number of pounds per container.
[3] Colors: Blue, gray
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 20
Recoat Cure Time and Temperature: 10 minutes at 350°F
[4] Colors: Black oxide, blue, clear, green, off white, red oxide, tank tan, white
Number of Coats: 1
Sequence of Coats: N/A
Maximum Field Use Dry Film Thickness (in mils): 20
Maximum Thinner: N/A
Recoat Cure Time and Temperature: 10 minutes at 350°F
|
||||
|
Coatings - Tank |
||||
| EAS6-60008[2] [3] | >= 1000 gal. | C. HOT | PEC | |
| EAS8-70011[2] [3] | >= 1000 gal. | C. HOT | PEC | |
| EBS8-70003[2] [4] | >= 1000 gal. | CLD 23 | PEC | |
| ECS8-70027[2] [4] | >= 1000 gal. | CLD 23 | PEC | |
| EGS6-0M001 WATTS AM ZR Primer[1] | >= 1000 gal. | C. HOT | ZINC | |
| EGS8-70010[2] [4] | >= 1000 gal. | CLD 23 | PEC | |
| EHS8-70014[2] [4] | >= 1000 gal. | CLD 23 | PEC | |
| ELS6-60004[2] [3] | >= 1000 gal. | C. HOT | PEC | |
| ELS6-60005[2] [3] | >= 1000 gal. | C. HOT | PEC | |
| ELS8-70012[2] [4] | >= 1000 gal. | CLD 23 | PEC | |
| ELS8-80002[2] [4] | >= 1000 gal. | CLD 23 | PEC | |
| ELS8-80003[2] [4] | >= 1000 gal. | CLD 23 | PEC | |
| ERS8-70002[2] [4] | >= 1000 gal. | CLD 23 | PEC | |
| EWS8-70015[2] [4] | >= 1000 gal. | CLD 23 | PEC | |
| EWS8-70024[2] [4] | >= 1000 gal. | CLD 23 | PEC | |
| EWS8-80007[2] [4] | >= 1000 gal. | CLD 23 | PEC | |
[1] Color: Gray
Number of coats: 1
Maximum field use dry film thickness (in mils): 10 mils
Special comments: Required cure time is 20 min @ 300F or 10 min @ 400F
[2] The suffixes indicate the following container type:
C - Box
D - Drum
I - Overpack/international box
J - Sample jar
S - Super sack
T - Tote
The number following the letter indicates fill size in number of pounds per container.
[3] Colors: Blue, gray
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 20
Recoat Cure Time and Temperature: 10 minutes at 350°F
[4] Colors: Black oxide, blue, clear, green, off white, red oxide, tank tan, white
Number of Coats: 1
Sequence of Coats: N/A
Maximum Field Use Dry Film Thickness (in mils): 20
Maximum Thinner: N/A
Recoat Cure Time and Temperature: 10 minutes at 350°F
|
||||
|
Coatings - Valve |
||||
| EAS6-60008[2] [3] | >= 2" | C. HOT | PEC | |
| EAS8-70011[2] [3] | >= 2" | C. HOT | PEC | |
| EBS8-70003[2] [4] | >= 2" | CLD 23 | PEC | |
| ECS8-70027[2] [4] | >= 2" | CLD 23 | PEC | |
| EGS6-0M001 WATTS AM ZR Primer[1] | >= 2" | C. HOT | ZINC | |
| EGS8-70010[2] [4] | >= 2" | CLD 23 | PEC | |
| EHS8-70014[2] [4] | >= 2" | CLD 23 | PEC | |
| ELS6-60004[2] [3] | >= 2" | C. HOT | PEC | |
| ELS6-60005[2] [3] | >= 2" | C. HOT | PEC | |
| ELS8-70012[2] [4] | >= 2" | CLD 23 | PEC | |
| ELS8-80002[2] [4] | >= 2" | CLD 23 | PEC | |
| ELS8-80003[2] [4] | >= 2" | CLD 23 | PEC | |
| ERS8-70002[2] [4] | >= 2" | CLD 23 | PEC | |
| EWS8-70015[2] [4] | >= 2" | CLD 23 | PEC | |
| EWS8-70024[2] [4] | >= 2" | CLD 23 | PEC | |
| EWS8-80007[2] [4] | >= 2" | CLD 23 | PEC | |
| HAS8-V0002 N61 Gray[5] | >= 2" | D. HOT | PEC | |
| HLS8-V0002 N61 Blue[5] | >= 2" | D. HOT | PEC | |
| LP4703G0 #5 Banner Blue[5] | >= 2" | D. HOT | PEC | |
| PHA80043 Gray Hybrid[5] | >= 2" | D. HOT | PEC | |
[1] Color: Gray
Number of coats: 1
Maximum field use dry film thickness (in mils): 10 mils
Special comments: Required cure time is 20 min @ 300F or 10 min @ 400F
[2] The suffixes indicate the following container type:
C - Box
D - Drum
I - Overpack/international box
J - Sample jar
S - Super sack
T - Tote
The number following the letter indicates fill size in number of pounds per container.
[3] Colors: Blue, gray
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 20
Recoat Cure Time and Temperature: 10 minutes at 350°F
[4] Colors: Black oxide, blue, clear, green, off white, red oxide, tank tan, white
Number of Coats: 1
Sequence of Coats: N/A
Maximum Field Use Dry Film Thickness (in mils): 20
Maximum Thinner: N/A
Recoat Cure Time and Temperature: 10 minutes at 350°F
[5] Colors: Blue or Gray
Number of coats: 4
Maximum field use dry film thickness(in mils): 44 (11 per coat)
Recoat cure time and temperature: 10 minutes at 400° F
Special comments: Cure time can be substituted with 7 minutes at 425° F or 15 minutes
at 375° F.
|
||||
Facility : Shanghai, China
Protective (Barrier) Materials
| Water | Water | |||
| Water Contact | Contact | Contact | ||
| Trade Designation | Size Restriction | Temp | Material | |
|
Coatings - Fittings[1] [2] |
||||
| IF9902M | >= 2” | C. HOT | PEC | |
[1] Sold in two alternate grind sizes (T and F) and two alternate package sizes (D and L).
The Listing applies to all grind sizes and package size designations.
[2] Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 8
Final Cure Time/Temperature: 15 minutes at 400F
|
||||
|
Coatings - Pipe[1] [2] |
||||
| IF9902M | >= 2” | C. HOT | PEC | |
[1] Sold in two alternate grind sizes (T and F) and two alternate package sizes (D and L).
The Listing applies to all grind sizes and package size designations.
[2] Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 8
Final Cure Time/Temperature: 15 minutes at 400F
|
||||
|
Coatings - Tank[1] [2] |
||||
| IF9902M | >= 4 gal | C. HOT | PEC | |
[1] Sold in two alternate grind sizes (T and F) and two alternate package sizes (D and L).
The Listing applies to all grind sizes and package size designations.
[2] Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 8
Final Cure Time/Temperature: 15 minutes at 400F
|
||||
|
Coatings - Valve[1] [2] |
||||
| IF9902M | >= 2” | C. HOT | PEC | |
[1] Sold in two alternate grind sizes (T and F) and two alternate package sizes (D and L).
The Listing applies to all grind sizes and package size designations.
[2] Number of Coats: 1
Maximum Field Use Dry Thickness (in mils): 8
Final Cure Time/Temperature: 15 minutes at 400F
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 169
Processing time was 0 seconds