NSF Product and Service Listings
These NSF Official Listings are current as of Friday, December 26, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=31270&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| Flowserve Corporation | |
| 5215 North O'Connor Boulevard | |
| Suite 2300 | |
| Irving, TX 75039 | |
| United States | |
| 972-443-6500 |
Facility : Taneytown, MD
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Pumps [G] |
||||
| VPC-(v)(w)(x)(y)-(z)[2] [3] | 6" - 52" | CLD 23 | MLTPL | |
| VTP-(v)(w)(x)(y)-(z)[2] [3] | 6" - 52" | CLD 23 | MLTPL | |
| [W]LNEC[X] BB1 Axially Split, Single Stage Pump[1] | 125 mm - 750 mm | CLD 23 | MLTPL | |
| [W]LNE[X] BB1 Axially Split, Single Stage Pump[1] | 125 mm - 750 mm | CLD 23 | MLTPL | |
| [W]LNNA[X] BB1 Axially Split, Single Stage Pump[1] | 200 mm - 1000 mm | CLD 23 | MLTPL | |
| [W]LNNC[X] BB1 Axially Split, Single Stage Pump[1] | 300 mm - 700 mm | CLD 23 | MLTPL | |
| [W]LNN[X] BB1 Axially Split, Single Stage Pump[1] | 200 mm - 1000 mm | CLD 23 | MLTPL | |
| [Y]LN[Z] BB1 Axially Split, Single Stage Pump[1] | 6" - 30" | CLD 23 | MLTPL | |
[1] [W] Represents the nominal discharge diameter in mm:
LNN and LNNA pumps
200, 250, 300, 350, 400, 500, 600, 700, 800, 900,or 1000
LNE and LNEC pumps
125, 200, 250, 300, 250, 400, 500, 600, 750
LNNC pumps
300, 600, or 700
[X] Represents the nominal impeller diameter in mm:
LNN and LNNA pumps:
300, 325, 375, 400, 450, 475, 500, 525, 575, 600, 625, 650, 725, 750, 800, 875, 900,
925, 950, 975, 1000, 1075, 1150, 1200, 1225, or 1250
LNE and LNEC Pumps
450, 550, 575, 675, 750, 850, 900, or 1050
LNNC pumps
475, 950, 975, or 1225
[Y] Represents the nominal discharge diameter in inches and may be 6, 8, 10, 12, 14, 16,
20, 24, or 30
[Z] Represents the nominal impeller diameter in inches and may be 10, 12, 14, 18, 19,
20, 23, 24, 26, 28, 29, 32, 40, or 41
Only pumps with coated interiors are Certified.
[2] [v][w][x][y]-[z]
v - Size of pump in inches (6-52)
w - Impeller type (blank, C, E, S)
x - Pump model (B, C, D, G, H, J, K , KX, L, M, N, P, Q, TM, X)
y - Impeller design (F, H, L, M, X, Y, Z)
z - Number of stages
[3] Certified for a minimum daily flow of 375,000 L.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Submersible Motors |
||||
| Flowserve (Byron Jackson) Submersible Motors (Mechanical Sealed)[4] [G] | 8" - 21" | CLD 23 | MLTPL | |
[4] Certified for a minimum daily flow of 150,000 L.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Submersible Pump - Pump/Motor Units [G] |
||||
| SUBM - Submersible Pump [v][w][x][y]-[z][5] [6] | 5" - 52" | CLD 23 | MLTPL | |
[5] Certified for a minimum daily flow of 150,000 L. Pumps with bronze cases are not
Certified.
[6] [v][w][x][y]-[z]
v - Size of pump in inches (5"-52")
w - Impeller type (blank, C, E)
x - Pump model (B, G, H, HQ, J, K, KX, L, LQ, M, MQ, N, P, Q, TM)
y - Impeller design (blank, F, H, L, M, X, Y, Z)
z - Number of stages
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Submersible Pump Cable [G] |
||||
| Flowserve (Byron Jackson) Submersible Cables | [4] [7] | CLD 23 | MLTPL | |
[4] Certified for a minimum daily flow of 150,000 L.
[7] 600 Volt: 1 AWG, 1/0 AWG, 2 AWG, 2/0 AWG, 3/0 AWG, 4 AWG, 4/0 AWG, 250 MCM, 350 MCM, 500
MCM
5000 Volt: 1 AWG, 1/0 AWG, 2 AWG, 2/0 AWG, 3/0 AWG, 4 AWG, 4/0 AWG
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
Facility : Kalamazoo, MI
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Miscellaneous Process Devices/Components[1] [G] |
||||
| ISC2-PX-61 | [2] | D. HOT | MLTPL | |
| PSS 4-61[3] | 1.5 - 6" | D. HOT | MLTPL | |
| PSSL-61[3] | 6.125 - 16" | D. HOT | MLTPL | |
[1] Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified. Certified for equivalent metric
sizes.
[2] Certified for use in pumps with shafts 1-8" in diameter.
[3] Certified size refers to pump shaft diameter.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
Facility : Hastings, NE
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Pumps[1] [2] [3] [G] |
||||
| VPC-(v)(w)(x)(y)-(z) | 6" - 52" | CLD 23 | MLTPL | |
| VTP-(v)(w)(x)(y)-(z) | 6" - 52" | CLD 23 | MLTPL | |
[1] [v][w][x][y]-[z]
v - Size of pump in inches (6-52)
w - Impeller type (blank, C, E, S)
x - Pump model (B, C, D, G, H, J, K , KX, L, M, N, P, Q, TM, X)
y - Impeller design (F, H, L, M, X, Y, Z)
z - Number of stages
[2] Certified for a minimum daily flow of 375,000 L.
[3] Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Submersible Pumps - Pump/Motor Units[3] [4] [5] [G] |
||||
| SUBM - Submersible Pump [v][w][x][y]- [z] | 5" - 52" | CLD 23 | MLTPL | |
| Flowserve (Byron Jackson) Submersible Cables[7] [8] | [6] | CLD 23 | MLTPL | |
[3] Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
[4] Certified for a minimum daily flow of 150,000 L. Pumps with bronze cases are not
Certified.
[5] [v][w][x][y]-[z]
v - Size of pump in inches (5"-52")
w - Impeller type (blank, C, E)
x - Pump model (B, G, H, HQ, J, K, KX, L, LQ, M, MQ, N, P, Q, TM)
y - Impeller design (blank, F, H, L, M, X, Y, Z)
z - Number of stages
[6] Certified for a minimum daily flow of 150,000 L.
[7] 600 Volt: 1 AWG, 1/0 AWG, 2 AWG, 2/0 AWG, 3/0 AWG, 4 AWG, 4/0 AWG, 250 MCM, 350 MCM, 500
MCM
[8] 5000 Volt: 1 AWG, 1/0 AWG, 2 AWG, 2/0 AWG, 3/0 AWG, 4 AWG, 4/0 AWG
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
Facility : Chesapeake, VA
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Pumps[1] [2] [G] |
||||
| Chesapeake Mark 3 ANSI Overhung Pumps, [A]K[B]x[C][D]-[E][F][G][3] | 1 1/2" x 1"-10" x 8" | CLD 23 | MLTPL | |
| [X]LR[Y][S] BB1 Axially Split, Single Stage Pump[4] | 2 1/2" - 12" | CLD 23 | MLTPL | |
[1] Certified for water end uses only. Certification not requested for chemical service.
[2] Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
[3] [A] Bearing frame size (group size in Flowserve terms)
1, 2, or 3
[B] Suction flange size (NB ANSI flange)
1.5, 2, 3, 4, 6, 8, or 10
[C] Discharge flange size (NB ANSI flange)
1, 1.5, 2, 3, 4, 6, or 8
[D] Special versions of Mark 3 products
Blank or no letter - standard pump
LF - Lo-Flo
[E] Maximum size of impeller (inch nominal)
4, 62 (6.2), 82 (8.2), 10, 13, 14, 16, or 17
[F] Revised hydraulic marker
() - Blank signifies no change to the original hydraulics of Mark 3 product
A - Significant hydraulic change
H - High Flow hydraulic design
HH - High Head hydraulic design
[G] Impeller Design
RV - Reverse Vane impeller design
OP - Open impeller design
[4] [S] Is an optional designation that identifies tounge and groove casing
rings fitted. Only pumps with coated interiors are Certified.
[X] Refers to the nominal discharge diameter in inches and may be 2.5,
3, 4, 5, 6, 8, 10 or 12.
[Y] Refers to the nominal impeller diameter in inches and may be 9, 10,
11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 23, or 25.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 20
Processing time was 0 seconds

