NSF Product and Service Listings

These NSF Official Listings are current as of Tuesday, May 14, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=36840&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
The Euclid Chemical Company 
19215 Redwood Road
Cleveland, OH 44110 
United States 
800-321-7628 
216-531-9222
Visit this company's website


Facility : Fontana, CA

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Concrete Admixtures
Accelguard NCA[1] [2] CLD 23 CMNT
Eucon AEA-92[3] [4] CLD 23 CMNT
Eucon AEA-92S[5] [4] CLD 23 CMNT
Eucon Stasis[6] [2] CLD 23 CMNT
Eucon WR-91[7] [4] CLD 23 CMNT
Eucon X-15[8] [2] CLD 23 CMNT
Plastol 6400[9] [10] CLD 23 CMNT
Plastol 6420[11] [9] CLD 23 CMNT

[1] Certified for a maximum use level of 75 oz/100 lbs cement.
[2] Certified for use in tanks 1000 gallons and greater, pipe and fittings 4" and greater.
[3] Certified for a maximum use level of 1 oz/100 lbs cement.
[4] Certified for pipes 4" and greater, tanks 1000 gallons and greater.
[5] Certified for a maximum use level of 2 oz/100 lbs cement.
[6] Certified for a maximum use level of 16 oz/100 lbs cement.
[7] Certified for a maximum use level of 6 oz/100 lbs cement.
[8] Certified for a maximum use level of 15 oz/100 lbs cement.
[9] Certified for pipes 8" and greater, tanks 1000 gallons and greater, fittings 4" and
    greater.
[10] Certified for a maximum use level of 8 oz/100 lbs cement.
[11] Certified for a maximum use level of 12 ox/100 lbs cement.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified. 


Facility : Odessa, FL

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Patching Materials[1] [2] [3]
EucoRepair V100 [4] CLD 23 CMNT

[1] Mix ratio is 46 lbs. EucoRepair V100 to 3.79 L of water.
[2] Certified for a 7 day moist cure at 73°F +/- 3°F (100% relative humidity) followed by
    1-3 day air cure at 73°F +/- 3°F (50% relative humdity).  Maximum application thickness
    is 2".
[3] Certification does not include Duralprep AC primer or Eucobar evaporation retarder.
[4] Certified for up to 10% of the surface area of tanks 100,000 gallons and greater.  25%
    of the surface area of tanks 1,500,000 gallons and greater.  6% of 120" pipe and greater
    and 25% of 10" fittings and greater. 


Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Fittings[1]
Tamoseal Gray >= 4" CLD 23 CMNT
Tamoseal Gray N >= 4" CLD 23 CMNT
Tamoseal White >= 4" CLD 23 CMNT
Tamoseal White N >= 4" CLD 23 CMNT

[1] Colors: Gray, White
    Number of Coats: 2
    Maximum Field Use Dry Thickness (in mils): 125 mils
    Recoat Cure Time and Temperature: 12 hours at 40°F
    Final Cure Time/Temperature: 7 days at 40°F
    Special Comments: Akkro-7T or Flex-Con additives are mixed 1:3 (additive: water) as the
    mixing liquid and then used at 2 gal per 50 lb Tamoseal. Induction time is 10 minutes.
    

Coatings - Pipe[1]
Tamoseal Gray >= 48" CLD 23 CMNT
Tamoseal Gray N >= 48" CLD 23 CMNT
Tamoseal White >= 48" CLD 23 CMNT
Tamoseal White N >= 48" CLD 23 CMNT

[1] Colors: Gray, White
    Number of Coats: 2
    Maximum Field Use Dry Thickness (in mils): 125 mils
    Recoat Cure Time and Temperature: 12 hours at 40°F
    Final Cure Time/Temperature: 7 days at 40°F
    Special Comments: Akkro-7T or Flex-Con additives are mixed 1:3 (additive: water) as the
    mixing liquid and then used at 2 gal per 50 lb Tamoseal. Induction time is 10 minutes.
    

Coatings - Tank[1]
Tamoseal Gray >= 3000 gal. CLD 23 CMNT
Tamoseal Gray N >= 3000 gal. CLD 23 CMNT
Tamoseal White >= 3000 gal. CLD 23 CMNT
Tamoseal White N >= 3000 gal. CLD 23 CMNT

[1] Colors: Gray, White
    Number of Coats: 2
    Maximum Field Use Dry Thickness (in mils): 125 mils
    Recoat Cure Time and Temperature: 12 hours at 40°F
    Final Cure Time/Temperature: 7 days at 40°F
    Special Comments: Akkro-7T or Flex-Con additives are mixed 1:3 (additive: water) as the
    mixing liquid and then used at 2 gal per 50 lb Tamoseal. Induction time is 10 minutes.
    



Facility : Cleveland, OH

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Patching Materials[1] [2] [3]
Carbocrete 4010 [4] CLD 23 CMNT
EucoRepair V100 [4] CLD 23 CMNT

[1] Mix ratio is 46 lbs. EucoRepair V100 to 3.79 L of water.
[2] Certified for a 7 day moist cure at 73°F +/- 3°F (100% relative humidity) followed by
    1-3 day air cure at 73°F +/- 3°F (50% relative humidity). Maximum application thickness
    is 2".
[3] Certification does not include Duralprep AC primer or Eucobar evaporation retarder.
[4] Certified for up to 10% of the surface area of tanks 100,000 gallons and greater, 25% of
    the surface area of tanks 1,500,000 gallons and greater, 6% of 120" pipe and greater and
    25% of 10" fittings and greater.


Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Tank
Vandex BB 75[1] >= 10,000 gal. CLD 23 CMNT
Vandex Super[2] >= 2000 gal. CLD 23 CMNT
Vandex Super White[3] >= 2000 gal. CLD 23 CMNT

[1] Colors: Gray
    Number of Coats: 1 - 2
    Maximum Field Use Dry Film Thickness (in mils): 200
    Recoat Cure Time and Temperature: 2 - 4 hours at 73°F while the first coat is still
    green.
    Final Cure Time and Temperature: 5 days damp cure at 73°F
    Special Comments: Mix ratio of Vandex BB 75 to water is 55 lbs:1.3-1.5 gal; induction
    period is 3 minutes
[2] Colors: Cement gray
    Number of Coats: 1 - 2
    Recoat Cure Time and Temperature: Second coat is applied while the first coat is still
    green (approximately 20-30 minutes at 72°F)
    Final Cure Time and Temperature: 5 days damp cure at 72°F
    Special Comments: Apply to concrete at a rate of 1.5 kg per square meter.  Mix ratio of
    Vandex Super to water is 5:2 by volume; induction period is 3 minutes
[3] Colors: White
    Number of Coats: 1 - 2
    Recoat Cure Time and Temperature: Second coat is applied while the first coat is still
    green (approximately 80-90 minutes at 72°F)
    Final Cure Time and Temperature: 5 days damp cure at 72°F
    Special Comments: Apply to concrete at a rate of 1.5 kg per square meter. Mix ratio of
    Vandex Super White to water is 5:2 by volume; induction period is 3 minutes

Concrete Admixtures
Conex [4] CLD 23 CMNT
Eucon Vandex AM-10 [5] CLD 23 CMNT

[4] Certified for a maximum use level of 10% by weight cement.  Certified for use in tanks
    1000 gallons and greater, pipes 12" and greater, and fittings 4" and greater.
[5] Certified for a level not to exceed 2% by weight of cement.  Certified for use in tanks
    1,000 gallons and greater and pipes and fittings 8" and greater.



Facility : Easton, PA

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Concrete Admixtures
Accelguard NCA[1] [2] CLD 23 CMNT
Accelguard® 80[3] [4] CLD 23 CMNT
Eucon 1037[5] [6] CLD 23 CMNT
Eucon AEA-92[7] [6] CLD 23 CMNT
Eucon AEA-92S[8] [6] CLD 23 CMNT
Eucon Air MAC12[9] [2] CLD 23 CMNT
Eucon Air MAC6[9] [2] CLD 23 CMNT
Eucon MR[10] [6] CLD 23 CMNT
Eucon Retarder 75[11] [6] CLD 23 CMNT
Eucon Stasis[12] [2] CLD 23 CMNT
Eucon WR-91[13] [6] CLD 23 CMNT
Plastol 6400[14] [15] CLD 23 CMNT
Plastol 6420[16] [15] CLD 23 CMNT

[1] Certified for a maximum use level of 75 oz/100 lbs cement.
[2] Certified for tanks 1000 gallons and greater and pipe and fittings 4" and greater.
[3] Certified for a maximum use level of 32 oz/100 lbs cement.
[4] Certified for pipes 8" and greater, tanks 1000 gallons and greater.
[5] Certified for a maximum use level of 25 oz/100 lbs cement.
[6] Certified for pipes 4" and greater, tanks 1000 gallons and greater.
[7] Certified for a maximum use level of 1 oz/100 lbs cement.
[8] Certified for a maximum use level of 2 oz/100 lbs cement.
[9] Certified for a maximum use level of 4 oz/100 lbs cement.
[10] Certified for a maximum use level of 10 oz/100 lbs cement.
[11] Certified for a maximum use level of 5 oz/100 lbs cement.
[12] Certified for a maximum use level of 16 fl. oz/100 lbs cement.
[13] Certified for a maximum use level of 6 oz/100 lbs cement.
[14] Certified for a maximum use level of 8 oz/100 lbs cement.
[15] Certified for pipes 8" and greater, tanks 1000 gallons and greater, fittings 4" and
     greater.
[16] Certified for a maximum use level of 12 oz/100 lbs cement.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Number of matching Manufacturers is 1
Number of matching Products is 41
Processing time was 0 seconds