NSF Product and Service Listings

These NSF Official Listings are current as of Monday, July 8, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=46690&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
Tnemec Company, Inc. 
6800 Corporate Drive
Kansas City, MO 64120-1372 
United States 
816-474-3400
Visit this company's website


Facility : Baltimore, MD

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Fittings
22 Epoxoline[1] [2] >= 1/2" CLD 23 EPOXY
N140F Pota-Pox Plus Fast Cure [2] [3] >= 2" CLD 23 EPOXY
Series 21 Epoxoline[2] [4] >= 1" CLD 23 EPOXY
Series 91-H2O ™ Hydro-Zinc™ [2] [6] [7] >= 1" CLD 23 EPOXY
Series 91-H2O ™ Hydro-Zinc™ [2] [5] [6] >= 1/2" CLD 23 EPOXY
Series 93-H20 Hydro-Zinc[8] >= 1" CLD 23 PUR
Series 94-H2O Hydro-Zinc[2] [9] [10] CLD 23 PUR
Series L140 Pota-Pox Plus [2] [11] >= 1" CLD 23 EPOXY
Series L140F Pota-Pox Plus Fast Cure [2] [12] >= 1" CLD 23 EPOXY
Series N140 Pota-Pox Plus[2] [13] >= 2" CLD 23 EPOXY
Series N140 Pota-Pox Plus[14] [15] >= 4" CLD 23 EPOXY
Series N140F Pota-Pox Plus Fast Cure[15] [16] >= 4" CLD 23 EPOXY

[1] Colors: 1255 Beige, 1218 Blue, WH11 White
    Number of Coats: 1-2
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: 5% Thinner #2
    Recoat Cure Time and Temperature: 16 hours at 75°F
    Final Cure Time and Temperature: 5 days at 75°F
    Special Comments: Mix ratio of Part A to Part B is 1:1 by volume.  Optional use with
    fiberglass flake S211-0220.  The fiberglass flake can be added up to a rate of 1% by
    weight after the Parts A and B are mixed together.  Certified for use as a primer or
    topcoat with any NSF Certified Tnemec coating system provided that both primer and
    topcoat meet their individual certified end uses.
[2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements
    of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes,
    toluene, and ethylbenzene. 
[3] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac
    Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592
    RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
    Number of Coats: 1
    Sequence of Coats: 4 mils
    Maximum Thinner: 10% No. 4 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F (entire system)
    Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an
    optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat
    coating system provided the primer, intermediate, and topcoat meet their certified end
    uses. 
[4] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712
    Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592
    RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness (in mils): 20
    Maximum Thinner: 5% F041-0088 Thinner Clear by volume
    Recoat Cure Time and Temperature: 8 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for
    use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[5] This coating used with Thinner #3 is Certified for use in pipes >=24", tanks >=1500
    gallons, fittings >=1/2", pumps >=1/2", valves >=2".
[6] Colors: Greenish-Gray
    Number of Coats: 1
    Maximum Field Use Dry Thickness (in mils): 4
    Maximum Thinner: 10% Thinner #2 or Thinner #3 by volume
    Final Cure Time/Temperature: 4 hours at 75F; 2 hours at 75F wen accelerator is used. 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl.oz/gal.
    Series 91-H2O Hydro-Zinc ™ is approved for use with any NSF Certified Tnemec topcoat or
    coatings system providing that both primer and topcoat meet their individual Certified
    end uses. Mix Ratio Part A:B is 70%:30% by volume.
[7] This coating used with Thinner #2 is Certified for use in pipes >=24", tanks >=3000
    gallons, fittings >=1", pumps >=1/2", and valves >=4".
[8] Colors: Greenish-Gray
    Maximum Field Use Dry Thickness(in mils): 4 mils
    Maximum Thinner: 10% Thinner #2 by volume
    Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. 
    Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20
    Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[9] Colors: Greenish-gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 4
    Maximum Thinner: 15% Tnemec No. 49 or 10% Thinner No. 2 or 10% Thinner No. 3 by volume
    Final Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator
    is used 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 
    94-H2O is aproved for use with any NSF Certified Tnemec topcoat or coating system.
[10] This coating used with Thinner #49 is Certified for use in fittings >= 1/2". This
     coating used with Thinner #2 is Certified for use in fittings >= 1". This coatings used
     with Thinner #3 is Certified for use in fittings >= 1/2".
[11] Colors: 1255 Beige, 15BL Tank White, 1211 Red, 00WH White 
     # of coats: 2-3
     # Seq Of Coats: Any combination of listed colors
     Max Film Thickness: 18 (Maximum of 6 mils per coat)
     Max Thinner: 5% Tnemec No. 49 Thinner by volume
     Recoat Cure Time/ Temp.:  16 hours at 75° F 
     Final Cure Time/ Temp.: 7 days at 75° F 
     Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be
     substituted as a primer or topcoat for L140 provided that both primer and topcoat meet
     their individual Certified end uses.  Series 44-700 accelerator (Part C) may be added up
     to 4 fluid ounces per two mixed gallons of L140 Parts A and B.  Mix ratio of A:B is 1:1
     by volume.
[12] Colors: 1255 Beige, 15BL Tank White, 1211 Red, 00WH White 
     # of coats: 2-3
     # Seq Of Coats: Any combination of listed colors
     Max Film Thickness: 18 (Maximum of 6 mils per coat)
     Max Thinner: 5% Tnemec No. 49 Thinner by volume
     Recoat Cure Time/ Temp.:  16 hours at 75° F 
     Final Cure Time/ Temp.: 7 days at 75° F 
     Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be
     substituted as a primer or topcoat for L140F provided that both primer and topcoat meet
     their individual Certified end uses.  Mix ratio of Part A to Part B is 1:1 by volume.
[13] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606
     Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130
     Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
     Number of Coats: 1
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% No. 4 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F (entire system)
     Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an
     optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat
     coating system provided the primer, intermediate, and topcoat meet their certified end
     uses.
[14] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft
     Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096
     Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506
     Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F
     without accelerator
     Final Cure Time and Temperature: 30 days at 75°F
     Special Comments: Any Listed color of Series 22, FC22, or N140, may be substituted as a
     primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat
     meet their individual Certified end uses.  The mix ratio of Part A:Part B is 1:1 by
     volume.  Part C (Series 44-700 Accelerator) is an optional additive to Part A in the
     field and may be added at up to 4 fluid ounces per 2 mixed gallons of parts A and B.
[15] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of
     NSF/ANSI/CAN 61 for pump, valve, and fitting end use.
[16] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896
     S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston
     Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F 
     Final Cure Time and Temperature: 30 days at 75°F
     Special Comments: Any listed color of series 22, FC22, or N140 may be substituted as a
     primer or topcoat for the Series N140 Pota-Pox Plus provided that both primer and
     topcoat meet their individual Certified end uses.  Mix ratio of Part A:Part B is 1:1 by
     volume.

Coatings - Mechanical Devices
22 Epoxoline [1] [2] [26] CLD 23 EPOXY
Series 21 Epoxoline[2] [4] [23] CLD 23 EPOXY
Series 91-H2O™ Hydro-Zinc™ [2] [5] [6] [7] [24] CLD 23 PUR
Series 93-H20 Hydro-Zinc[8] [27] CLD 23 PUR
Series 94-H2O Hydro Zinc [2] [9] [24] [25] CLD 23 PUR
Series N140 Pota-Pox Plus[14] [15] [22] CLD 23 EPOXY
Series N140F Pota-Pox Plus Fast Cure[15] [16] [22] CLD 23 EPOXY

[1] Colors: 1255 Beige, 1218 Blue, WH11 White
    Number of Coats: 1-2
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: 5% Thinner #2
    Recoat Cure Time and Temperature: 16 hours at 75°F
    Final Cure Time and Temperature: 5 days at 75°F
    Special Comments: Mix ratio of Part A to Part B is 1:1 by volume.  Optional use with
    fiberglass flake S211-0220.  The fiberglass flake can be added up to a rate of 1% by
    weight after the Parts A and B are mixed together.  Certified for use as a primer or
    topcoat with any NSF Certified Tnemec coating system provided that both primer and
    topcoat meet their individual certified end uses.
[2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements
    of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes,
    toluene, and ethylbenzene. 
[4] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712
    Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592
    RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness (in mils): 20
    Maximum Thinner: 5% F041-0088 Thinner Clear by volume
    Recoat Cure Time and Temperature: 8 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for
    use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[5] This coating used with Thinner #3 is Certified for use in pipes >=24", tanks >=1500
    gallons, fittings >=1/2", pumps >=1/2", valves >=2".
[6] Colors: Greenish-Gray
    Number of Coats: 1
    Maximum Field Use Dry Thickness (in mils): 4
    Maximum Thinner: 10% Thinner #2 or Thinner #3 by volume
    Final Cure Time/Temperature: 4 hours at 75F; 2 hours at 75F wen accelerator is used. 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl.oz/gal.
    Series 91-H2O Hydro-Zinc ™ is approved for use with any NSF Certified Tnemec topcoat or
    coatings system providing that both primer and topcoat meet their individual Certified
    end uses. Mix Ratio Part A:B is 70%:30% by volume.
[7] This coating used with Thinner #2 is Certified for use in pipes >=24", tanks >=3000
    gallons, fittings >=1", pumps >=1/2", and valves >=4".
[8] Colors: Greenish-Gray
    Maximum Field Use Dry Thickness(in mils): 4 mils
    Maximum Thinner: 10% Thinner #2 by volume
    Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. 
    Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20
    Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[9] Colors: Greenish-gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 4
    Maximum Thinner: 15% Tnemec No. 49 or 10% Thinner No. 2 or 10% Thinner No. 3 by volume
    Final Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator
    is used 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 
    94-H2O is aproved for use with any NSF Certified Tnemec topcoat or coating system.
[14] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft
     Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096
     Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506
     Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F
     without accelerator
     Final Cure Time and Temperature: 30 days at 75°F
     Special Comments: Any Listed color of Series 22, FC22, or N140, may be substituted as a
     primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat
     meet their individual Certified end uses.  The mix ratio of Part A:Part B is 1:1 by
     volume.  Part C (Series 44-700 Accelerator) is an optional additive to Part A in the
     field and may be added at up to 4 fluid ounces per 2 mixed gallons of parts A and B.
[15] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of
     NSF/ANSI/CAN 61 for pump, valve, and fitting end use.
[16] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896
     S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston
     Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F 
     Final Cure Time and Temperature: 30 days at 75°F
     Special Comments: Any listed color of series 22, FC22, or N140 may be substituted as a
     primer or topcoat for the Series N140 Pota-Pox Plus provided that both primer and
     topcoat meet their individual Certified end uses.  Mix ratio of Part A:Part B is 1:1 by
     volume.
[22] Certified for mechanical device end use (other than pump and valve) for a maximum of 4.6
     sq. ft. per gpm. 
[23] Certified for mechanical device end use (other than pump and valve) for a maximum of
     50.5 sq. ft. per gpm.
[24] Certified for mechanical device end use (other than pump and valve) for a maximum of 151
     sq. ft. per gpm when used with Thinner #2 and 189 sq. ft. per gpm when used with Thinner
     #3.
[25] This coating used with Thinner #49 is Certified for mechanical device end use (other
     than pump and valve) for a maximum of 310 sq. ft. per gpm. 
[26] Certified for mechanical device end use (other than pump and valve) for a maximum of 635
     sq. ft. per gpm.
[27] Certified for mechanical device end use (other than pump and valve) for a maximum of 151
     sq. ft per gpm.

Coatings - Pipe
22 Epoxoline[1] [2] >= 10" CLD 23 EPOXY
N140F Pota-Pox Plus Fast Cure [2] [3] >= 36" CLD 23 EPOXY
Series 91-H2O ™ Hydro-Zinc™ [2] [5] [6] [7] >= 24" CLD 23 EPOXY
Series 93-H20 Hydro-Zinc[8] >= 24" CLD 23 PUR
Series 94-H2O Hydro-Zinc[2] [9] [17] CLD 23 PUR
Series N140 Pota-Pox Plus[2] [13] >= 36" CLD 23 EPOXY

[1] Colors: 1255 Beige, 1218 Blue, WH11 White
    Number of Coats: 1-2
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: 5% Thinner #2
    Recoat Cure Time and Temperature: 16 hours at 75°F
    Final Cure Time and Temperature: 5 days at 75°F
    Special Comments: Mix ratio of Part A to Part B is 1:1 by volume.  Optional use with
    fiberglass flake S211-0220.  The fiberglass flake can be added up to a rate of 1% by
    weight after the Parts A and B are mixed together.  Certified for use as a primer or
    topcoat with any NSF Certified Tnemec coating system provided that both primer and
    topcoat meet their individual certified end uses.
[2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements
    of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes,
    toluene, and ethylbenzene. 
[3] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac
    Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592
    RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
    Number of Coats: 1
    Sequence of Coats: 4 mils
    Maximum Thinner: 10% No. 4 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F (entire system)
    Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an
    optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat
    coating system provided the primer, intermediate, and topcoat meet their certified end
    uses. 
[5] This coating used with Thinner #3 is Certified for use in pipes >=24", tanks >=1500
    gallons, fittings >=1/2", pumps >=1/2", valves >=2".
[6] Colors: Greenish-Gray
    Number of Coats: 1
    Maximum Field Use Dry Thickness (in mils): 4
    Maximum Thinner: 10% Thinner #2 or Thinner #3 by volume
    Final Cure Time/Temperature: 4 hours at 75F; 2 hours at 75F wen accelerator is used. 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl.oz/gal.
    Series 91-H2O Hydro-Zinc ™ is approved for use with any NSF Certified Tnemec topcoat or
    coatings system providing that both primer and topcoat meet their individual Certified
    end uses. Mix Ratio Part A:B is 70%:30% by volume.
[7] This coating used with Thinner #2 is Certified for use in pipes >=24", tanks >=3000
    gallons, fittings >=1", pumps >=1/2", and valves >=4".
[8] Colors: Greenish-Gray
    Maximum Field Use Dry Thickness(in mils): 4 mils
    Maximum Thinner: 10% Thinner #2 by volume
    Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. 
    Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20
    Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[9] Colors: Greenish-gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 4
    Maximum Thinner: 15% Tnemec No. 49 or 10% Thinner No. 2 or 10% Thinner No. 3 by volume
    Final Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator
    is used 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 
    94-H2O is aproved for use with any NSF Certified Tnemec topcoat or coating system.
[13] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606
     Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130
     Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
     Number of Coats: 1
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% No. 4 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F (entire system)
     Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an
     optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat
     coating system provided the primer, intermediate, and topcoat meet their certified end
     uses.
[17] This coating used with Thinner #49 is Certified for use in pipes >= 18". This coating
     used with Thinner #2 and Thinner #3 is Certified for use in pipes >=24". 

Coatings - Pump
22 Epoxoline[1] [2] >= 1/2" CLD 23 EPOXY
N140F Pota-Pox Plus Fast Cure[2] [3] >= 4" CLD 23 EPOXY
Series 21 Epoxoline[2] [4] >= 4” CLD 23 EPOXY
Series 91-H2O ™ Hydro-Zinc™ [2] [5] [6] [7] >= 1/2" CLD 23 EPOXY
Series 93-H20 Hydro-Zinc[8] >= 1/2" CLD 23 PUR
Series 94-H2O Hydro-Zinc[2] [9] [18] >1/2" CLD 23 PUR
Series N140 Pota-Pox Plus[14] [15] >= 4" CLD 23 EPOXY
Series N140 Pota-Pox Plus [2] [13] >= 4" CLD 23 EPOXY
Series N140F Pota-Pox Plus Fast Cure[15] [16] >= 4" CLD 23 EPOXY

[1] Colors: 1255 Beige, 1218 Blue, WH11 White
    Number of Coats: 1-2
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: 5% Thinner #2
    Recoat Cure Time and Temperature: 16 hours at 75°F
    Final Cure Time and Temperature: 5 days at 75°F
    Special Comments: Mix ratio of Part A to Part B is 1:1 by volume.  Optional use with
    fiberglass flake S211-0220.  The fiberglass flake can be added up to a rate of 1% by
    weight after the Parts A and B are mixed together.  Certified for use as a primer or
    topcoat with any NSF Certified Tnemec coating system provided that both primer and
    topcoat meet their individual certified end uses.
[2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements
    of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes,
    toluene, and ethylbenzene. 
[3] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac
    Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592
    RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
    Number of Coats: 1
    Sequence of Coats: 4 mils
    Maximum Thinner: 10% No. 4 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F (entire system)
    Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an
    optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat
    coating system provided the primer, intermediate, and topcoat meet their certified end
    uses. 
[4] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712
    Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592
    RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness (in mils): 20
    Maximum Thinner: 5% F041-0088 Thinner Clear by volume
    Recoat Cure Time and Temperature: 8 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for
    use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[5] This coating used with Thinner #3 is Certified for use in pipes >=24", tanks >=1500
    gallons, fittings >=1/2", pumps >=1/2", valves >=2".
[6] Colors: Greenish-Gray
    Number of Coats: 1
    Maximum Field Use Dry Thickness (in mils): 4
    Maximum Thinner: 10% Thinner #2 or Thinner #3 by volume
    Final Cure Time/Temperature: 4 hours at 75F; 2 hours at 75F wen accelerator is used. 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl.oz/gal.
    Series 91-H2O Hydro-Zinc ™ is approved for use with any NSF Certified Tnemec topcoat or
    coatings system providing that both primer and topcoat meet their individual Certified
    end uses. Mix Ratio Part A:B is 70%:30% by volume.
[7] This coating used with Thinner #2 is Certified for use in pipes >=24", tanks >=3000
    gallons, fittings >=1", pumps >=1/2", and valves >=4".
[8] Colors: Greenish-Gray
    Maximum Field Use Dry Thickness(in mils): 4 mils
    Maximum Thinner: 10% Thinner #2 by volume
    Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. 
    Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20
    Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[9] Colors: Greenish-gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 4
    Maximum Thinner: 15% Tnemec No. 49 or 10% Thinner No. 2 or 10% Thinner No. 3 by volume
    Final Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator
    is used 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 
    94-H2O is aproved for use with any NSF Certified Tnemec topcoat or coating system.
[13] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606
     Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130
     Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
     Number of Coats: 1
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% No. 4 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F (entire system)
     Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an
     optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat
     coating system provided the primer, intermediate, and topcoat meet their certified end
     uses.
[14] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft
     Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096
     Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506
     Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F
     without accelerator
     Final Cure Time and Temperature: 30 days at 75°F
     Special Comments: Any Listed color of Series 22, FC22, or N140, may be substituted as a
     primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat
     meet their individual Certified end uses.  The mix ratio of Part A:Part B is 1:1 by
     volume.  Part C (Series 44-700 Accelerator) is an optional additive to Part A in the
     field and may be added at up to 4 fluid ounces per 2 mixed gallons of parts A and B.
[15] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of
     NSF/ANSI/CAN 61 for pump, valve, and fitting end use.
[16] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896
     S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston
     Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F 
     Final Cure Time and Temperature: 30 days at 75°F
     Special Comments: Any listed color of series 22, FC22, or N140 may be substituted as a
     primer or topcoat for the Series N140 Pota-Pox Plus provided that both primer and
     topcoat meet their individual Certified end uses.  Mix ratio of Part A:Part B is 1:1 by
     volume.
[18] This coating used with Thinner #49, Thinner #2 and Thinner #3 is Certified for use in
     pumps >= 1/2". 

Coatings - Tank
22 Epoxoline[1] [2] >= 50 gal. CLD 23 EPOXY
N140F Pota-Pox Plus Fast Cure [2] [3] >= 1,500 gal. CLD 23 EPOXY
Series 21 Epoxoline [2] [4] >= 90,000 gal. CLD 23 EPOXY
Series 406 Elastoshield[2] [19] >= 50,000 gal. CLD 23 PUR
Series 91-H2O ™ Hydro-Zinc™ [2] [5] [6] >= 1500 gal. CLD 23 EPOXY
Series 91-H2O ™ Hydro-Zinc™ [2] [6] [7] >= 3000 gal. CLD 23 EPOXY
Series 93-H20 Hydro-Zinc[8] >= 3,000 gal CLD 23 PUR
Series 94-H2O Hydro Zinc[2] [9] [20] CLD 23 PUR
Series L140 Pota-Pox Plus [2] [12] >= 50,000 gal. CLD 23 EPOXY
Series L140F Pota-Pox Plus Fast Cure [2] [12] >= 50,000 gal. CLD 23 EPOXY
Series N140 Pota-Pox Plus [2] [13] >= 1,500 gal. CLD 23 EPOXY

[1] Colors: 1255 Beige, 1218 Blue, WH11 White
    Number of Coats: 1-2
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: 5% Thinner #2
    Recoat Cure Time and Temperature: 16 hours at 75°F
    Final Cure Time and Temperature: 5 days at 75°F
    Special Comments: Mix ratio of Part A to Part B is 1:1 by volume.  Optional use with
    fiberglass flake S211-0220.  The fiberglass flake can be added up to a rate of 1% by
    weight after the Parts A and B are mixed together.  Certified for use as a primer or
    topcoat with any NSF Certified Tnemec coating system provided that both primer and
    topcoat meet their individual certified end uses.
[2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements
    of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes,
    toluene, and ethylbenzene. 
[3] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac
    Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592
    RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
    Number of Coats: 1
    Sequence of Coats: 4 mils
    Maximum Thinner: 10% No. 4 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F (entire system)
    Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an
    optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat
    coating system provided the primer, intermediate, and topcoat meet their certified end
    uses. 
[4] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712
    Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592
    RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness (in mils): 20
    Maximum Thinner: 5% F041-0088 Thinner Clear by volume
    Recoat Cure Time and Temperature: 8 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for
    use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[5] This coating used with Thinner #3 is Certified for use in pipes >=24", tanks >=1500
    gallons, fittings >=1/2", pumps >=1/2", valves >=2".
[6] Colors: Greenish-Gray
    Number of Coats: 1
    Maximum Field Use Dry Thickness (in mils): 4
    Maximum Thinner: 10% Thinner #2 or Thinner #3 by volume
    Final Cure Time/Temperature: 4 hours at 75F; 2 hours at 75F wen accelerator is used. 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl.oz/gal.
    Series 91-H2O Hydro-Zinc ™ is approved for use with any NSF Certified Tnemec topcoat or
    coatings system providing that both primer and topcoat meet their individual Certified
    end uses. Mix Ratio Part A:B is 70%:30% by volume.
[7] This coating used with Thinner #2 is Certified for use in pipes >=24", tanks >=3000
    gallons, fittings >=1", pumps >=1/2", and valves >=4".
[8] Colors: Greenish-Gray
    Maximum Field Use Dry Thickness(in mils): 4 mils
    Maximum Thinner: 10% Thinner #2 by volume
    Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. 
    Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20
    Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[9] Colors: Greenish-gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 4
    Maximum Thinner: 15% Tnemec No. 49 or 10% Thinner No. 2 or 10% Thinner No. 3 by volume
    Final Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator
    is used 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 
    94-H2O is aproved for use with any NSF Certified Tnemec topcoat or coating system.
[12] Colors: 1255 Beige, 15BL Tank White, 1211 Red, 00WH White 
     # of coats: 2-3
     # Seq Of Coats: Any combination of listed colors
     Max Film Thickness: 18 (Maximum of 6 mils per coat)
     Max Thinner: 5% Tnemec No. 49 Thinner by volume
     Recoat Cure Time/ Temp.:  16 hours at 75° F 
     Final Cure Time/ Temp.: 7 days at 75° F 
     Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be
     substituted as a primer or topcoat for L140F provided that both primer and topcoat meet
     their individual Certified end uses.  Mix ratio of Part A to Part B is 1:1 by volume.
[13] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606
     Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130
     Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
     Number of Coats: 1
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% No. 4 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F (entire system)
     Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an
     optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat
     coating system provided the primer, intermediate, and topcoat meet their certified end
     uses.
[19] Colors: WH06 Off-White	
     Number of Coats: 1-2
     Sequence of Coats: Primer (optional), Series 406 Elastoshield (topcoat)
     Maximum Field Use Dry Film Thickness (in mils): Topcoat-75
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 72 hours at 75°F
     Special Comments: Mix ratio for primers must meet their individual certified parameters.
     Mix ratio of A:B is 1:2 by volume for Topcoat. Certified for use as a topcoat with any
     Tnemec NSF Certified coating system provided both primer and topcoat meet their
     individual certified end uses.
[20] This coating used with Thinner #49 is Certified for use in tanks >= 400 gallons. This
     coating used with Thinner #2 is Certified for use in tank >=3000 gallons. This coating
     used with Thinner #3 is Certified for use in tanks >=1500 gallons. 

Coatings - Valve
22 Epoxoline[1] [2] >= 1/2" CLD 23 EPOXY
N140F Pota-Pox Plus Fast Cure[2] [3] >= 4" CLD 23 EPOXY
Series 21 Epoxoline[2] [4] >= 4" CLD 23 EPOXY
Series 406 Elastoshield[2] [19] >= 4" CLD 23 PUR
Series 91-H2O ™ Hydro-Zinc™ [2] [5] [6] >= 2" CLD 23 EPOXY
Series 91-H2O™ Hydro-Zinc™ [2] [6] [7] >= 4" CLD 23 EPOXY
Series 93-H20 Hydro-Zinc[8] >= 4" CLD 23 PUR
Series 94-H2O Hydro-Zinc[2] [9] [21] CLD 23 PUR
Series N140 Pota-Pox Plus[14] [15] >= 4" CLD 23 EPOXY
Series N140 Pota-Pox Plus [2] [13] >= 4" CLD 23 EPOXY
Series N140F Pota-Pox Plus Fast Cure[15] [16] >= 4" CLD 23 EPOXY

[1] Colors: 1255 Beige, 1218 Blue, WH11 White
    Number of Coats: 1-2
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: 5% Thinner #2
    Recoat Cure Time and Temperature: 16 hours at 75°F
    Final Cure Time and Temperature: 5 days at 75°F
    Special Comments: Mix ratio of Part A to Part B is 1:1 by volume.  Optional use with
    fiberglass flake S211-0220.  The fiberglass flake can be added up to a rate of 1% by
    weight after the Parts A and B are mixed together.  Certified for use as a primer or
    topcoat with any NSF Certified Tnemec coating system provided that both primer and
    topcoat meet their individual certified end uses.
[2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements
    of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes,
    toluene, and ethylbenzene. 
[3] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac
    Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592
    RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
    Number of Coats: 1
    Sequence of Coats: 4 mils
    Maximum Thinner: 10% No. 4 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F (entire system)
    Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an
    optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat
    coating system provided the primer, intermediate, and topcoat meet their certified end
    uses. 
[4] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712
    Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592
    RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness (in mils): 20
    Maximum Thinner: 5% F041-0088 Thinner Clear by volume
    Recoat Cure Time and Temperature: 8 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for
    use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[5] This coating used with Thinner #3 is Certified for use in pipes >=24", tanks >=1500
    gallons, fittings >=1/2", pumps >=1/2", valves >=2".
[6] Colors: Greenish-Gray
    Number of Coats: 1
    Maximum Field Use Dry Thickness (in mils): 4
    Maximum Thinner: 10% Thinner #2 or Thinner #3 by volume
    Final Cure Time/Temperature: 4 hours at 75F; 2 hours at 75F wen accelerator is used. 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl.oz/gal.
    Series 91-H2O Hydro-Zinc ™ is approved for use with any NSF Certified Tnemec topcoat or
    coatings system providing that both primer and topcoat meet their individual Certified
    end uses. Mix Ratio Part A:B is 70%:30% by volume.
[7] This coating used with Thinner #2 is Certified for use in pipes >=24", tanks >=3000
    gallons, fittings >=1", pumps >=1/2", and valves >=4".
[8] Colors: Greenish-Gray
    Maximum Field Use Dry Thickness(in mils): 4 mils
    Maximum Thinner: 10% Thinner #2 by volume
    Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. 
    Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20
    Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[9] Colors: Greenish-gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 4
    Maximum Thinner: 15% Tnemec No. 49 or 10% Thinner No. 2 or 10% Thinner No. 3 by volume
    Final Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator
    is used 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 
    94-H2O is aproved for use with any NSF Certified Tnemec topcoat or coating system.
[13] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606
     Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130
     Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
     Number of Coats: 1
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% No. 4 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F (entire system)
     Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an
     optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat
     coating system provided the primer, intermediate, and topcoat meet their certified end
     uses.
[14] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft
     Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096
     Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506
     Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F
     without accelerator
     Final Cure Time and Temperature: 30 days at 75°F
     Special Comments: Any Listed color of Series 22, FC22, or N140, may be substituted as a
     primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat
     meet their individual Certified end uses.  The mix ratio of Part A:Part B is 1:1 by
     volume.  Part C (Series 44-700 Accelerator) is an optional additive to Part A in the
     field and may be added at up to 4 fluid ounces per 2 mixed gallons of parts A and B.
[15] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of
     NSF/ANSI/CAN 61 for pump, valve, and fitting end use.
[16] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896
     S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston
     Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F 
     Final Cure Time and Temperature: 30 days at 75°F
     Special Comments: Any listed color of series 22, FC22, or N140 may be substituted as a
     primer or topcoat for the Series N140 Pota-Pox Plus provided that both primer and
     topcoat meet their individual Certified end uses.  Mix ratio of Part A:Part B is 1:1 by
     volume.
[19] Colors: WH06 Off-White	
     Number of Coats: 1-2
     Sequence of Coats: Primer (optional), Series 406 Elastoshield (topcoat)
     Maximum Field Use Dry Film Thickness (in mils): Topcoat-75
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 72 hours at 75°F
     Special Comments: Mix ratio for primers must meet their individual certified parameters.
     Mix ratio of A:B is 1:2 by volume for Topcoat. Certified for use as a topcoat with any
     Tnemec NSF Certified coating system provided both primer and topcoat meet their
     individual certified end uses.
[21] This coating used with Thinner #49 is Certified for use in valves >=1/2". This coatings
     used with Thinner #2 is Certified for use in valves >= 4". This coating used with
     Thinner #3 is Certified for use in valves >= 2".



Facility : North Kansas City, MO

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Fittings
22 Epoxoline[1] [2] >= 6" CLD 23 EPOXY
F098-0H20 Hydro-Zinc[2] [3] >= 1" CLD 23 EPOXY
N140F Pota-Pox Plus Fast Cure[2] [4] >= 2" CLD 23 EPOXY
Series 1220 Tnemec Epoxy[5] >= 1/2" CLD 23 EPOXY
Series 21 Epoxoline[2] [7] >= 3/4" CLD 23 EPOXY
Series 21 Epoxoline[2] [6] >= 1/2" CLD 23 EPOXY
Series 91-H2O™ Hydro-Zinc™[2] [8] [9] [10] >= 1" CLD 23 PUR
Series 93-H20 Hydro-Zinc[11] >= 1" CLD 23 PUR
Series 94-H2O Hydro-Zinc[2] [12] [13] CLD 23 PUR
Series FC22 Epoxoline[2] [14] >= 1/2" CLD 23 EPOXY
Series L140 Pota-Pox Plus[2] [15] >= 1" CLD 23 EPOXY
Series L140F Pota-Pox Plus Fast Cure[2] [16] >= 1" CLD 23 EPOXY
Series N140 Pota-Pox Plus[18] [22] >= 4" CLD 23 EPOXY
Series N140 Pota-Pox Plus [2] [17] >= 2" CLD 23 EPOXY
Series N140F Pota-Pox Plus Fast Cure[18] [19] >= 4" CLD 23 EPOXY

[1] Colors: 1255 Beige, 1218 Blue, WH11 White
    Number of Coats: 1-2
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: 5% Thinner #2
    Recoat Cure Time and Temperature: 16 hours at 75°F 
    Final Cure Time and Temperature: 5 days at 75°F
    Special Comments: Mix ratio of Part A to Part B is 1:1 by volume.  Optional use with
    fiberglass flake S211-0220.  The fiberglass flake can be added up to a rate of 1% by
    weight after the Parts A and B are mixed together.  Certified for use as a primer or
    topcoat with any NSF Certified Tnemec coating system provided that both primer and
    topcoat meet their individual certified end uses.
[2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements
    of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes,
    toluene, and ethylbenzene. 
[3] Colors: Greenish Gray
    Number of Coats: 1
    Maximum Field Use Dry Thickness (in mils): 4mils
    Maximum Thinner: 25% Water
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Series 44-780 Accelerator may be added up to 1 fl. oz/gal. Series
    98-H2O Hydro-Zinc is approved for use as a primer with any NSF Certified Tnemec topcoat
    or coating system providing that both primer and topcoat meet their individual Certified
    end uses. Cure for Series 98-H2O Hydro-Zinc primer is 5 hours at 75F. Top-coat is then
    applied. Final cure is 7 days. Mix ratio of Part A:B:C is 1.4:0.6:1 by volume.
[4] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac
    Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592
    RAL 5009 Azurblau,  B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
    Number of Coats: 1
    Sequence of Coats: 4 mils
    Maximum Thinner: 10% No. 4 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F (entire system)
    Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an
    optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat
    coating system provided the primer, intermediate, and topcoat meet their certified end
    uses. 
[5] Colors: White
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness (in mils): 18 mils
    Maximum Thinner: 15% water
    Recoat Cure Time and Temperature: 6 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Series 44-700 Accelerator may be added up to 1 fl. oz./gal. Series
    1220 Tnemec Epoxy is approved for use as a primer or topcoat with any NSF Certified
    Tnemec topcoat or coating system providing that both primer and topcoat meet their
    individual Certified end uses. Mix ratio of Part A:Part B is 2:1 by volume.
[6] Colors: WH16 Off-White, 1255 Beige, 39BL Delft Blue, B5712 Westech Blue, 11SF True
    Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506
    Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 2
    Maximum Field Use Dry Thickness(in mils): 20 mils
    Maximum Thinner: None
    Recoat Cure Time and Temperature: 16 hours at 75F
    Final Cure Time/Temperature: 30 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. This is for pipe, fitting, pump and
    valve end use.
[7] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712
    Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592
    RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness(in mils): 20
    Maximum Thinner: 5% F041-0088 Thinner Clear by volume
    Recoat Cure Time and Temperature: 8 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for
    use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[8] Colors: Greenish-gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 4
    Maximum Thinner: 10% Thinner No. 2 or 10% Thinner No. 3 by volume
    Final Cure Time and Temperature: 4 hours at 75°F; 2 hours at 75°F when the accelerator
    is used 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 
    Series 91-H2O™ Hydro-Zinc™ is approved for use with any NSF Certified Tnemec topcoat or
    coating system providing that both primer and topcoat meet their individual Certified
    end uses.  Mix ratio of Part A:Part B is 70%:30% by volume.
[9] This coating used with Thinner #2 is Certified for use in pipes >=96", tanks >=50,000
    gallons, fittings >=1", pumps >=1", and valves >=4".
[10] This coatings used with Thinner #3 is Certified for use in pipes >=96", tanks >=40,000
     gallons, fittings >=1", pumps >=1/2", and valves >=1.75".
[11] Colors: Greenish-Gray
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% Thinner #2 by volume
     Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. 
     Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20
     Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system
     providing that both primer and topcoat meet their individual Certified end uses.
[12] Color: Greenish-Gray
     Number of Coats: 1
     Maximum Field Use Dry Film Thickness (in mils): 4
     Maximum Thinner: 15% Tnemec No. 49 by volume or 10% Thinner No. 3 or 10% Thinner No. 2
     Recoat Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator
     is used  
     Special Comments: Series 44-710 may be added up to 4 fl. oz/gal. 94-H2O is approved for
     use with any NSF Certified Tnemec topcoat or coating system.
[13] This coating used with Thinner #49 is Certified for use in fittings >= ½”. This coating
     used with Thinner #2 and #3 is Certified for use in fittings >= 1”.
[14] Colors: WH08 White, R4875A Akzo Red, B8869A Epoxoline Blue
     Number of Coats: 1
     Sequence of Coats: N/A
     Maximum Field Use Dry Film Thickness (in mils): 80
     Maximum Thinner: None
     Final Cure Time and Temperature: 24 hours at 75°F
     Special Comments: Mix ratio of Part A:Part B is 1:2 by volume.  Any Listed color of
     series N140 or N140F may be used as a topcoat or primer for Series FC22 Epoxoline.
[15] Colors: 00WH White, 1211 Red, 1255 Beige, 15BL Tank White
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18 (maximum of 6 mils per coat)
     Maximum Thinner: 5% Tnemec No. 49 Thinner by volume
     Recoat Cure Time and Temperature: 16 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F
     Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be
     substituted as a primer or topcoat for L140 provided that both primer and topcoat meet
     their individual Certified end uses. Series 44-700 accelerator (Part C) may be added up
     to 4 fluid ounces per two mixed gallons of L140 Parts A and B. Mix ratio of A:B is 1:1
     by volume.
[16] Colors: 1255 Beige, 15BL Tank White, 1211 Red, 00WH White
     Number of Coats: 2-3
     Sequence of coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18 (maximum of 6 mils per coat)
     Maximum Thinner: 5% Tnemec No. 49 by volume
     Recoat Cure Time and Temperature: 16 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F
     Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be
     substituted as a primer or topcoat for L140F provided that both primer and topcoat meet
     their individual Certified end uses. Mix ratio of Part A to Part B is 1:1 by volume.
[17] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606
     Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695
     Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 1
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% No. 4 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F (entire system)
     Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use
     as an optional primer or intermediate coat with any Tnemec NSF certified primer
     and topcoat coating system provided the primer, intermediate, and topcoat meet
     their certified end uses. Part C (Series 44-700 Accelerator) is an optional additive to
     Part A in the field and may be added at up to 4 fluid ounces per gallon of Part A.
[18] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of
     NSF/ANSI/CAN 61 for pump, valve, and fitting end use.
[19] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft
     Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896
     S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston
     Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 30 days at 75°F
     Special comments: Any listed color of Series 22, FC22, N140 or 141 may be substituted as
     a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat
     meet their individual Certified end uses.  The mix ratio of Part A:Part B is 1:1 by
     volume.
[22] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft
     Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096
     Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506
     Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F
     without accelerator
     Final Cure Time and Temperature: 30 days at 75°F
     Special Comments: Any Listed color of Series 22, FC22, N140, or 141 may be substituted
     as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and
     topcoat meet their individual Certified end uses.  The mix ratio of Part A:Part B is 1:1
     by volume.  Part C (Series 44-700 Accelerator) is an optional addititve to Part A in the
     field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B.

Coatings - Mechanical Devices
22 Epoxoline [1] [2] [31] CLD 23 EPOXY
Series 21 Epoxoline [2] [7] [29] CLD 23 EPOXY
Series 91-H2O™ Hydro-Zinc™[2] [9] [10] [12] [30] CLD 23 PUR
Series 93-H20 Hydro-Zinc[11] [33] CLD 23 PUR
Series 94-H2O Hydro Zinc [2] [12] [30] [32] CLD 23 PUR
Series N140 Pota-Pox Plus [18] [22] [28] CLD 23 EPOXY
Series N140F Pota-Pox Plus Fast Cure[17] [19] [28] CLD 23 EPOXY

[1] Colors: 1255 Beige, 1218 Blue, WH11 White
    Number of Coats: 1-2
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: 5% Thinner #2
    Recoat Cure Time and Temperature: 16 hours at 75°F 
    Final Cure Time and Temperature: 5 days at 75°F
    Special Comments: Mix ratio of Part A to Part B is 1:1 by volume.  Optional use with
    fiberglass flake S211-0220.  The fiberglass flake can be added up to a rate of 1% by
    weight after the Parts A and B are mixed together.  Certified for use as a primer or
    topcoat with any NSF Certified Tnemec coating system provided that both primer and
    topcoat meet their individual certified end uses.
[2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements
    of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes,
    toluene, and ethylbenzene. 
[7] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712
    Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592
    RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness(in mils): 20
    Maximum Thinner: 5% F041-0088 Thinner Clear by volume
    Recoat Cure Time and Temperature: 8 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for
    use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[9] This coating used with Thinner #2 is Certified for use in pipes >=96", tanks >=50,000
    gallons, fittings >=1", pumps >=1", and valves >=4".
[10] This coatings used with Thinner #3 is Certified for use in pipes >=96", tanks >=40,000
     gallons, fittings >=1", pumps >=1/2", and valves >=1.75".
[11] Colors: Greenish-Gray
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% Thinner #2 by volume
     Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. 
     Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20
     Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system
     providing that both primer and topcoat meet their individual Certified end uses.
[12] Color: Greenish-Gray
     Number of Coats: 1
     Maximum Field Use Dry Film Thickness (in mils): 4
     Maximum Thinner: 15% Tnemec No. 49 by volume or 10% Thinner No. 3 or 10% Thinner No. 2
     Recoat Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator
     is used  
     Special Comments: Series 44-710 may be added up to 4 fl. oz/gal. 94-H2O is approved for
     use with any NSF Certified Tnemec topcoat or coating system.
[17] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606
     Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695
     Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 1
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% No. 4 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F (entire system)
     Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use
     as an optional primer or intermediate coat with any Tnemec NSF certified primer
     and topcoat coating system provided the primer, intermediate, and topcoat meet
     their certified end uses. Part C (Series 44-700 Accelerator) is an optional additive to
     Part A in the field and may be added at up to 4 fluid ounces per gallon of Part A.
[18] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of
     NSF/ANSI/CAN 61 for pump, valve, and fitting end use.
[19] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft
     Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896
     S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston
     Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 30 days at 75°F
     Special comments: Any listed color of Series 22, FC22, N140 or 141 may be substituted as
     a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat
     meet their individual Certified end uses.  The mix ratio of Part A:Part B is 1:1 by
     volume.
[22] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft
     Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096
     Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506
     Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F
     without accelerator
     Final Cure Time and Temperature: 30 days at 75°F
     Special Comments: Any Listed color of Series 22, FC22, N140, or 141 may be substituted
     as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and
     topcoat meet their individual Certified end uses.  The mix ratio of Part A:Part B is 1:1
     by volume.  Part C (Series 44-700 Accelerator) is an optional addititve to Part A in the
     field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B.
[28] Certified for mechanical device end use (other than pump and valve) for a maximum of 4.6
     sq. ft. per gpm. 
[29] Certified for mechanical device end use (other than pump and valve) for a maximum of 189
     sq. ft. per gpm.
[30] Certified for mechanical device end use (other than pump and valve) for a minimum of 60
     sq. ft. per gpm when used with Thinner #2 and 64 sq. ft. per gpm when used with Thinner
     #3. 
[31] Certified for mechanical device end use (other than pump and valve) for a maximum of 249
     sq. ft. per gpm.
[32] This coating used with Thinner #49 is Certified for mechanical device end use (other
     than pump and valve) for a maximum of 189 sq. Ft. per gpm. 
[33] Certified for mechanical device end use (other than pump and valve) for a maximum of 60
     sq. ft per gpm. 

Coatings - Pipe
22 Epoxoline[1] [2] >= 24" CLD 23 EPOXY
F098-0H20 Hydro-Zinc[2] [3] >= 120" CLD 23 EPOXY
N140F Pota-Pox Plus Fast Cure [2] [4] >= 42" CLD 23 EPOXY
Series 1 Omnithane 1216 Greenish-Gray[2] [20] >= 36" CLD 23 PUR
Series 1220 Tnemec Epoxy[2] [5] >= 6" CLD 23 EPOXY
Series 21 Epoxoline[2] [6] >= 18" CLD 23 EPOXY
Series 91-H2O™ Hydro-Zinc™[2] [8] [9] [10] >= 96" CLD 23 PUR
Series 93-H20 Hydro-Zinc [11] >= 96" CLD 23 PUR
Series 94-H2O Hydro-Zinc[2] [12] [21] CLD 23 PUR
Series FC22 Epoxoline[2] [14] >= 8" CLD 23 EPOXY
Series N140 Pota-Pox Plus [2] [17] >= 42" CLD 23 EPOXY

[1] Colors: 1255 Beige, 1218 Blue, WH11 White
    Number of Coats: 1-2
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: 5% Thinner #2
    Recoat Cure Time and Temperature: 16 hours at 75°F 
    Final Cure Time and Temperature: 5 days at 75°F
    Special Comments: Mix ratio of Part A to Part B is 1:1 by volume.  Optional use with
    fiberglass flake S211-0220.  The fiberglass flake can be added up to a rate of 1% by
    weight after the Parts A and B are mixed together.  Certified for use as a primer or
    topcoat with any NSF Certified Tnemec coating system provided that both primer and
    topcoat meet their individual certified end uses.
[2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements
    of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes,
    toluene, and ethylbenzene. 
[3] Colors: Greenish Gray
    Number of Coats: 1
    Maximum Field Use Dry Thickness (in mils): 4mils
    Maximum Thinner: 25% Water
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Series 44-780 Accelerator may be added up to 1 fl. oz/gal. Series
    98-H2O Hydro-Zinc is approved for use as a primer with any NSF Certified Tnemec topcoat
    or coating system providing that both primer and topcoat meet their individual Certified
    end uses. Cure for Series 98-H2O Hydro-Zinc primer is 5 hours at 75F. Top-coat is then
    applied. Final cure is 7 days. Mix ratio of Part A:B:C is 1.4:0.6:1 by volume.
[4] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac
    Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592
    RAL 5009 Azurblau,  B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
    Number of Coats: 1
    Sequence of Coats: 4 mils
    Maximum Thinner: 10% No. 4 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F (entire system)
    Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an
    optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat
    coating system provided the primer, intermediate, and topcoat meet their certified end
    uses. 
[5] Colors: White
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness (in mils): 18 mils
    Maximum Thinner: 15% water
    Recoat Cure Time and Temperature: 6 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Series 44-700 Accelerator may be added up to 1 fl. oz./gal. Series
    1220 Tnemec Epoxy is approved for use as a primer or topcoat with any NSF Certified
    Tnemec topcoat or coating system providing that both primer and topcoat meet their
    individual Certified end uses. Mix ratio of Part A:Part B is 2:1 by volume.
[6] Colors: WH16 Off-White, 1255 Beige, 39BL Delft Blue, B5712 Westech Blue, 11SF True
    Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506
    Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 2
    Maximum Field Use Dry Thickness(in mils): 20 mils
    Maximum Thinner: None
    Recoat Cure Time and Temperature: 16 hours at 75F
    Final Cure Time/Temperature: 30 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. This is for pipe, fitting, pump and
    valve end use.
[8] Colors: Greenish-gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 4
    Maximum Thinner: 10% Thinner No. 2 or 10% Thinner No. 3 by volume
    Final Cure Time and Temperature: 4 hours at 75°F; 2 hours at 75°F when the accelerator
    is used 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 
    Series 91-H2O™ Hydro-Zinc™ is approved for use with any NSF Certified Tnemec topcoat or
    coating system providing that both primer and topcoat meet their individual Certified
    end uses.  Mix ratio of Part A:Part B is 70%:30% by volume.
[9] This coating used with Thinner #2 is Certified for use in pipes >=96", tanks >=50,000
    gallons, fittings >=1", pumps >=1", and valves >=4".
[10] This coatings used with Thinner #3 is Certified for use in pipes >=96", tanks >=40,000
     gallons, fittings >=1", pumps >=1/2", and valves >=1.75".
[11] Colors: Greenish-Gray
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% Thinner #2 by volume
     Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. 
     Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20
     Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system
     providing that both primer and topcoat meet their individual Certified end uses.
[12] Color: Greenish-Gray
     Number of Coats: 1
     Maximum Field Use Dry Film Thickness (in mils): 4
     Maximum Thinner: 15% Tnemec No. 49 by volume or 10% Thinner No. 3 or 10% Thinner No. 2
     Recoat Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator
     is used  
     Special Comments: Series 44-710 may be added up to 4 fl. oz/gal. 94-H2O is approved for
     use with any NSF Certified Tnemec topcoat or coating system.
[14] Colors: WH08 White, R4875A Akzo Red, B8869A Epoxoline Blue
     Number of Coats: 1
     Sequence of Coats: N/A
     Maximum Field Use Dry Film Thickness (in mils): 80
     Maximum Thinner: None
     Final Cure Time and Temperature: 24 hours at 75°F
     Special Comments: Mix ratio of Part A:Part B is 1:2 by volume.  Any Listed color of
     series N140 or N140F may be used as a topcoat or primer for Series FC22 Epoxoline.
[17] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606
     Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695
     Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 1
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% No. 4 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F (entire system)
     Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use
     as an optional primer or intermediate coat with any Tnemec NSF certified primer
     and topcoat coating system provided the primer, intermediate, and topcoat meet
     their certified end uses. Part C (Series 44-700 Accelerator) is an optional additive to
     Part A in the field and may be added at up to 4 fluid ounces per gallon of Part A.
[20] Colors: 1216 Greenish-Gray
     Number of Coats: 1
     Sequence of Coats: N/A
     Maximum Field Use Dry Film Thickness (in mils): 4
     Maximum Thinner: 10% Thinner No. 2
     Recoat Cure Time and Temperature: 8 hours at 75°F
     Special Comment: Series 44-710 may be added up to 4 fl. oz/gal. Approved for use as a
     primer with any NSF Certified Tnemec topcoat or coating system provided that both primer
     and topcoat meet their individual Certified end uses.
[21] This coating used with Thinner #49 is Certified for use in pipes <= 22”. This coating
     used with Thinner #2 and #3 is Certified for use in pipes >= 96”. 

Coatings - Pump
22 Epoxoline[1] [2] >= 4" CLD 23 EPOXY
F098-0H20 Hydro-Zinc[2] [3] >= 4" CLD 23 EPOXY
N140F Pota-Pox Plus Fast Cure[2] [4] >= 4" CLD 23 EPOXY
Series 1220 Tnemec Epoxy[2] [5] >= 1 1/2" CLD 23 EPOXY
Series 21 Epoxoline[2] [7] >= 4" CLD 23 EPOXY
Series 21 Epoxoline[2] [6] >= 1/2" CLD 23 EPOXY
Series 91-H2O ™ Hydro-Zinc™ [2] [8] [10] >= 1/2" CLD 23 PUR
Series 91-H2O™ Hydro-Zinc™[2] [8] [9] >= 1" CLD 23 PUR
Series 93-H20 Hydro-Zinc [11] >= 1" CLD 23 PUR
Series 94-H2O Hydro-Zinc[2] [12] [23] CLD 23 PUR
Series FC22 Epoxoline[2] [14] >= 2" CLD 23 EPOXY
Series N140 Pota-Pox Plus[18] [22] >= 4" CLD 23 EPOXY
Series N140 Pota-Pox Plus[2] [17] >= 4" CLD 23 EPOXY
Series N140F Pota-Pox Plus Fast Cure[18] [19] >= 4" CLD 23 EPOXY

[1] Colors: 1255 Beige, 1218 Blue, WH11 White
    Number of Coats: 1-2
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: 5% Thinner #2
    Recoat Cure Time and Temperature: 16 hours at 75°F 
    Final Cure Time and Temperature: 5 days at 75°F
    Special Comments: Mix ratio of Part A to Part B is 1:1 by volume.  Optional use with
    fiberglass flake S211-0220.  The fiberglass flake can be added up to a rate of 1% by
    weight after the Parts A and B are mixed together.  Certified for use as a primer or
    topcoat with any NSF Certified Tnemec coating system provided that both primer and
    topcoat meet their individual certified end uses.
[2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements
    of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes,
    toluene, and ethylbenzene. 
[3] Colors: Greenish Gray
    Number of Coats: 1
    Maximum Field Use Dry Thickness (in mils): 4mils
    Maximum Thinner: 25% Water
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Series 44-780 Accelerator may be added up to 1 fl. oz/gal. Series
    98-H2O Hydro-Zinc is approved for use as a primer with any NSF Certified Tnemec topcoat
    or coating system providing that both primer and topcoat meet their individual Certified
    end uses. Cure for Series 98-H2O Hydro-Zinc primer is 5 hours at 75F. Top-coat is then
    applied. Final cure is 7 days. Mix ratio of Part A:B:C is 1.4:0.6:1 by volume.
[4] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac
    Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592
    RAL 5009 Azurblau,  B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
    Number of Coats: 1
    Sequence of Coats: 4 mils
    Maximum Thinner: 10% No. 4 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F (entire system)
    Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an
    optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat
    coating system provided the primer, intermediate, and topcoat meet their certified end
    uses. 
[5] Colors: White
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness (in mils): 18 mils
    Maximum Thinner: 15% water
    Recoat Cure Time and Temperature: 6 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Series 44-700 Accelerator may be added up to 1 fl. oz./gal. Series
    1220 Tnemec Epoxy is approved for use as a primer or topcoat with any NSF Certified
    Tnemec topcoat or coating system providing that both primer and topcoat meet their
    individual Certified end uses. Mix ratio of Part A:Part B is 2:1 by volume.
[6] Colors: WH16 Off-White, 1255 Beige, 39BL Delft Blue, B5712 Westech Blue, 11SF True
    Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506
    Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 2
    Maximum Field Use Dry Thickness(in mils): 20 mils
    Maximum Thinner: None
    Recoat Cure Time and Temperature: 16 hours at 75F
    Final Cure Time/Temperature: 30 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. This is for pipe, fitting, pump and
    valve end use.
[7] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712
    Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592
    RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness(in mils): 20
    Maximum Thinner: 5% F041-0088 Thinner Clear by volume
    Recoat Cure Time and Temperature: 8 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for
    use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[8] Colors: Greenish-gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 4
    Maximum Thinner: 10% Thinner No. 2 or 10% Thinner No. 3 by volume
    Final Cure Time and Temperature: 4 hours at 75°F; 2 hours at 75°F when the accelerator
    is used 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 
    Series 91-H2O™ Hydro-Zinc™ is approved for use with any NSF Certified Tnemec topcoat or
    coating system providing that both primer and topcoat meet their individual Certified
    end uses.  Mix ratio of Part A:Part B is 70%:30% by volume.
[9] This coating used with Thinner #2 is Certified for use in pipes >=96", tanks >=50,000
    gallons, fittings >=1", pumps >=1", and valves >=4".
[10] This coatings used with Thinner #3 is Certified for use in pipes >=96", tanks >=40,000
     gallons, fittings >=1", pumps >=1/2", and valves >=1.75".
[11] Colors: Greenish-Gray
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% Thinner #2 by volume
     Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. 
     Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20
     Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system
     providing that both primer and topcoat meet their individual Certified end uses.
[12] Color: Greenish-Gray
     Number of Coats: 1
     Maximum Field Use Dry Film Thickness (in mils): 4
     Maximum Thinner: 15% Tnemec No. 49 by volume or 10% Thinner No. 3 or 10% Thinner No. 2
     Recoat Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator
     is used  
     Special Comments: Series 44-710 may be added up to 4 fl. oz/gal. 94-H2O is approved for
     use with any NSF Certified Tnemec topcoat or coating system.
[14] Colors: WH08 White, R4875A Akzo Red, B8869A Epoxoline Blue
     Number of Coats: 1
     Sequence of Coats: N/A
     Maximum Field Use Dry Film Thickness (in mils): 80
     Maximum Thinner: None
     Final Cure Time and Temperature: 24 hours at 75°F
     Special Comments: Mix ratio of Part A:Part B is 1:2 by volume.  Any Listed color of
     series N140 or N140F may be used as a topcoat or primer for Series FC22 Epoxoline.
[17] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606
     Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695
     Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 1
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% No. 4 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F (entire system)
     Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use
     as an optional primer or intermediate coat with any Tnemec NSF certified primer
     and topcoat coating system provided the primer, intermediate, and topcoat meet
     their certified end uses. Part C (Series 44-700 Accelerator) is an optional additive to
     Part A in the field and may be added at up to 4 fluid ounces per gallon of Part A.
[18] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of
     NSF/ANSI/CAN 61 for pump, valve, and fitting end use.
[19] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft
     Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896
     S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston
     Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 30 days at 75°F
     Special comments: Any listed color of Series 22, FC22, N140 or 141 may be substituted as
     a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat
     meet their individual Certified end uses.  The mix ratio of Part A:Part B is 1:1 by
     volume.
[22] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft
     Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096
     Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506
     Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F
     without accelerator
     Final Cure Time and Temperature: 30 days at 75°F
     Special Comments: Any Listed color of Series 22, FC22, N140, or 141 may be substituted
     as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and
     topcoat meet their individual Certified end uses.  The mix ratio of Part A:Part B is 1:1
     by volume.  Part C (Series 44-700 Accelerator) is an optional addititve to Part A in the
     field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B.
[23] This coating used with Thinner #49 is Certified for use in pumps >= ¾”. This coating
     used with Thinner #2 is Certified for use in pumps >= 1”. This coating used with Thinner
     #3 is Certified for use in pumps >= ½”.

Coatings - Tank
22 Epoxoline[1] [2] >= 700 gal. CLD 23 EPOXY
F098-0H20 Hydro-Zinc[2] [3] >= 70,000 gal. CLD 23 EPOXY
N140F Pota-Pox Plus Fast Cure[2] [4] >= 4,000 gal. CLD 23 EPOXY
Series 1 Omnithane 1216 Greenish-Gray[2] [20] >= 1000 gal. CLD 23 PUR
Series 1220 Tnemec Epoxy[2] [5] >= 200 gal. CLD 23 EPOXY
Series 21 Epoxoline[2] [7] >= 1,500 gal. CLD 23 EPOXY
Series 215[2] [24] >= 200 gal. CLD 23 EPOXY
Series 215ML[2] [24] >= 200 gal. CLD 23 EPOXY
Series 91-H2O ™ Hydro-Zinc™ [2] [8] [10] >= 40,000 gal. CLD 23 PUR
Series 91-H2O™ Hydro-Zinc™[2] [8] [9] >= 50,000 gal. CLD 23 PUR
Series 93-H20 Hydro-Zinc [11] >= 50,000 gal CLD 23 PUR
Series 94-H2O Hydro Zinc[2] [12] [25] CLD 23 PUR
Series FC22 Epoxoline[2] [26] >= 200 gal. CLD 23 EPOXY
Series L140 Pota-Pox Plus[2] [15] >= 50,000 gal. CLD 23 EPOXY
Series L140F Pota-Pox Plus Fast Cure[2] [16] >= 50,000 gal. CLD 23 EPOXY
Series N140 Pota-Pox Plus[2] [17] >= 4,000 gal. CLD 23 EPOXY

[1] Colors: 1255 Beige, 1218 Blue, WH11 White
    Number of Coats: 1-2
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: 5% Thinner #2
    Recoat Cure Time and Temperature: 16 hours at 75°F 
    Final Cure Time and Temperature: 5 days at 75°F
    Special Comments: Mix ratio of Part A to Part B is 1:1 by volume.  Optional use with
    fiberglass flake S211-0220.  The fiberglass flake can be added up to a rate of 1% by
    weight after the Parts A and B are mixed together.  Certified for use as a primer or
    topcoat with any NSF Certified Tnemec coating system provided that both primer and
    topcoat meet their individual certified end uses.
[2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements
    of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes,
    toluene, and ethylbenzene. 
[3] Colors: Greenish Gray
    Number of Coats: 1
    Maximum Field Use Dry Thickness (in mils): 4mils
    Maximum Thinner: 25% Water
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Series 44-780 Accelerator may be added up to 1 fl. oz/gal. Series
    98-H2O Hydro-Zinc is approved for use as a primer with any NSF Certified Tnemec topcoat
    or coating system providing that both primer and topcoat meet their individual Certified
    end uses. Cure for Series 98-H2O Hydro-Zinc primer is 5 hours at 75F. Top-coat is then
    applied. Final cure is 7 days. Mix ratio of Part A:B:C is 1.4:0.6:1 by volume.
[4] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac
    Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592
    RAL 5009 Azurblau,  B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
    Number of Coats: 1
    Sequence of Coats: 4 mils
    Maximum Thinner: 10% No. 4 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F (entire system)
    Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an
    optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat
    coating system provided the primer, intermediate, and topcoat meet their certified end
    uses. 
[5] Colors: White
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness (in mils): 18 mils
    Maximum Thinner: 15% water
    Recoat Cure Time and Temperature: 6 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Series 44-700 Accelerator may be added up to 1 fl. oz./gal. Series
    1220 Tnemec Epoxy is approved for use as a primer or topcoat with any NSF Certified
    Tnemec topcoat or coating system providing that both primer and topcoat meet their
    individual Certified end uses. Mix ratio of Part A:Part B is 2:1 by volume.
[7] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712
    Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592
    RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness(in mils): 20
    Maximum Thinner: 5% F041-0088 Thinner Clear by volume
    Recoat Cure Time and Temperature: 8 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for
    use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[8] Colors: Greenish-gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 4
    Maximum Thinner: 10% Thinner No. 2 or 10% Thinner No. 3 by volume
    Final Cure Time and Temperature: 4 hours at 75°F; 2 hours at 75°F when the accelerator
    is used 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 
    Series 91-H2O™ Hydro-Zinc™ is approved for use with any NSF Certified Tnemec topcoat or
    coating system providing that both primer and topcoat meet their individual Certified
    end uses.  Mix ratio of Part A:Part B is 70%:30% by volume.
[9] This coating used with Thinner #2 is Certified for use in pipes >=96", tanks >=50,000
    gallons, fittings >=1", pumps >=1", and valves >=4".
[10] This coatings used with Thinner #3 is Certified for use in pipes >=96", tanks >=40,000
     gallons, fittings >=1", pumps >=1/2", and valves >=1.75".
[11] Colors: Greenish-Gray
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% Thinner #2 by volume
     Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. 
     Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20
     Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system
     providing that both primer and topcoat meet their individual Certified end uses.
[12] Color: Greenish-Gray
     Number of Coats: 1
     Maximum Field Use Dry Film Thickness (in mils): 4
     Maximum Thinner: 15% Tnemec No. 49 by volume or 10% Thinner No. 3 or 10% Thinner No. 2
     Recoat Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator
     is used  
     Special Comments: Series 44-710 may be added up to 4 fl. oz/gal. 94-H2O is approved for
     use with any NSF Certified Tnemec topcoat or coating system.
[15] Colors: 00WH White, 1211 Red, 1255 Beige, 15BL Tank White
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18 (maximum of 6 mils per coat)
     Maximum Thinner: 5% Tnemec No. 49 Thinner by volume
     Recoat Cure Time and Temperature: 16 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F
     Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be
     substituted as a primer or topcoat for L140 provided that both primer and topcoat meet
     their individual Certified end uses. Series 44-700 accelerator (Part C) may be added up
     to 4 fluid ounces per two mixed gallons of L140 Parts A and B. Mix ratio of A:B is 1:1
     by volume.
[16] Colors: 1255 Beige, 15BL Tank White, 1211 Red, 00WH White
     Number of Coats: 2-3
     Sequence of coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18 (maximum of 6 mils per coat)
     Maximum Thinner: 5% Tnemec No. 49 by volume
     Recoat Cure Time and Temperature: 16 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F
     Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be
     substituted as a primer or topcoat for L140F provided that both primer and topcoat meet
     their individual Certified end uses. Mix ratio of Part A to Part B is 1:1 by volume.
[17] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606
     Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695
     Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 1
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% No. 4 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F (entire system)
     Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use
     as an optional primer or intermediate coat with any Tnemec NSF certified primer
     and topcoat coating system provided the primer, intermediate, and topcoat meet
     their certified end uses. Part C (Series 44-700 Accelerator) is an optional additive to
     Part A in the field and may be added at up to 4 fluid ounces per gallon of Part A.
[20] Colors: 1216 Greenish-Gray
     Number of Coats: 1
     Sequence of Coats: N/A
     Maximum Field Use Dry Film Thickness (in mils): 4
     Maximum Thinner: 10% Thinner No. 2
     Recoat Cure Time and Temperature: 8 hours at 75°F
     Special Comment: Series 44-710 may be added up to 4 fl. oz/gal. Approved for use as a
     primer with any NSF Certified Tnemec topcoat or coating system provided that both primer
     and topcoat meet their individual Certified end uses.
[24] Colors: 1200 White, 1212 Gray
     Number of Coats: 1
     Maximum Field Use Dry Film Thickness (in mils): Coating only: 80; With fiberglass mat:
     95
     Final Cure Time and Temperature: 7 days at 75°F
     Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with
     fiberglass mat S211-0215, S211-0216, and/or addition of fumed silica S211-0211 to
     coating. Mix ratio for fumed silica is 0.75:1 by volume. Approved for use with any NSF
     Certified Tnemec topcoat or coating system provided that both primer and topcoat meet
     their individual Certified end uses.
[25] This coating used with Thinner #49 is Certified for use in tanks >= 1,500 gallons. This
     coating used with Thinner #2 is Certified for use in tanks >= 50,000 gallons. This
     coating used with Thinner #3 is Certified for use in tanks >= 40,000 gallons.
[26] Colors: WH08 White, 35GR Epoxoline Black, R4875A Akzo Red, B8869A Epoxoline Blue
     Number of Coats: 1
     Sequence of Coats: N/A
     Maximum Field Use Dry Film Thickness (in mils): 80
     Maximum Thinner: None
     Final Cure Time and Temperature: 24 hours at 75° F
     Special Comments: Mix ratio of part A:Part B is 1:2 by volume.  Any Listed color of
     Series F020, FC20, L140, L140F, N140, N140F, V140, or V140F may be used as a topcoat or
     primer for SeriesFC22 Epoxoline.

Coatings - Valve
22 Epoxoline[1] [2] >= 4" CLD 23 EPOXY
F098-0H20 Hydro-Zinc[2] [3] >= 4" CLD 23 EPOXY
N140F Pota-Pox Plus Fast Cure[2] [4] >= 4" CLD 23 EPOXY
Series 1 Omnithane 1216 Greenish-Gray[2] [20] >= 4" CLD 23 PUR
Series 1220 Tnemec Epoxy[2] [5] >= 1 1/2" CLD 23 EPOXY
Series 21 Epoxoline[2] [7] >= 4" CLD 23 EPOXY
Series 21 Epoxoline [2] [6] >= 1/2" CLD 23 EPOXY
Series 91-H2O ™ Hydro-Zinc™[2] [8] [10] >= 1 3/4" CLD 23 EPOXY
Series 91-H2O™ Hydro-Zinc™[2] [8] [9] >= 4" CLD 23 PUR
Series 93-H20 Hydro-Zinc[11] >= 4" CLD 23 PUR
Series 94-H2O Hydro-Zinc[2] [12] [27] CLD 23 PUR
Series FC22 Epoxoline[2] [14] >= 2" CLD 23 EPOXY
Series N140 Pota-Pox Plus[18] [22] >= 4" CLD 23 EPOXY
Series N140 Pota-Pox Plus [2] [17] >= 4" CLD 23 EPOXY
Series N140F Pota-Pox Plus Fast Cure[18] [19] >= 4" CLD 23 EPOXY

[1] Colors: 1255 Beige, 1218 Blue, WH11 White
    Number of Coats: 1-2
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: 5% Thinner #2
    Recoat Cure Time and Temperature: 16 hours at 75°F 
    Final Cure Time and Temperature: 5 days at 75°F
    Special Comments: Mix ratio of Part A to Part B is 1:1 by volume.  Optional use with
    fiberglass flake S211-0220.  The fiberglass flake can be added up to a rate of 1% by
    weight after the Parts A and B are mixed together.  Certified for use as a primer or
    topcoat with any NSF Certified Tnemec coating system provided that both primer and
    topcoat meet their individual certified end uses.
[2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements
    of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes,
    toluene, and ethylbenzene. 
[3] Colors: Greenish Gray
    Number of Coats: 1
    Maximum Field Use Dry Thickness (in mils): 4mils
    Maximum Thinner: 25% Water
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Series 44-780 Accelerator may be added up to 1 fl. oz/gal. Series
    98-H2O Hydro-Zinc is approved for use as a primer with any NSF Certified Tnemec topcoat
    or coating system providing that both primer and topcoat meet their individual Certified
    end uses. Cure for Series 98-H2O Hydro-Zinc primer is 5 hours at 75F. Top-coat is then
    applied. Final cure is 7 days. Mix ratio of Part A:B:C is 1.4:0.6:1 by volume.
[4] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac
    Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592
    RAL 5009 Azurblau,  B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
    Number of Coats: 1
    Sequence of Coats: 4 mils
    Maximum Thinner: 10% No. 4 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F (entire system)
    Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an
    optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat
    coating system provided the primer, intermediate, and topcoat meet their certified end
    uses. 
[5] Colors: White
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness (in mils): 18 mils
    Maximum Thinner: 15% water
    Recoat Cure Time and Temperature: 6 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Series 44-700 Accelerator may be added up to 1 fl. oz./gal. Series
    1220 Tnemec Epoxy is approved for use as a primer or topcoat with any NSF Certified
    Tnemec topcoat or coating system providing that both primer and topcoat meet their
    individual Certified end uses. Mix ratio of Part A:Part B is 2:1 by volume.
[6] Colors: WH16 Off-White, 1255 Beige, 39BL Delft Blue, B5712 Westech Blue, 11SF True
    Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506
    Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 2
    Maximum Field Use Dry Thickness(in mils): 20 mils
    Maximum Thinner: None
    Recoat Cure Time and Temperature: 16 hours at 75F
    Final Cure Time/Temperature: 30 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. This is for pipe, fitting, pump and
    valve end use.
[7] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712
    Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592
    RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness(in mils): 20
    Maximum Thinner: 5% F041-0088 Thinner Clear by volume
    Recoat Cure Time and Temperature: 8 hours at 75F
    Final Cure Time/Temperature: 7 days at 75F
    Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for
    use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system
    providing that both primer and topcoat meet their individual Certified end uses.
[8] Colors: Greenish-gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 4
    Maximum Thinner: 10% Thinner No. 2 or 10% Thinner No. 3 by volume
    Final Cure Time and Temperature: 4 hours at 75°F; 2 hours at 75°F when the accelerator
    is used 
    Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 
    Series 91-H2O™ Hydro-Zinc™ is approved for use with any NSF Certified Tnemec topcoat or
    coating system providing that both primer and topcoat meet their individual Certified
    end uses.  Mix ratio of Part A:Part B is 70%:30% by volume.
[9] This coating used with Thinner #2 is Certified for use in pipes >=96", tanks >=50,000
    gallons, fittings >=1", pumps >=1", and valves >=4".
[10] This coatings used with Thinner #3 is Certified for use in pipes >=96", tanks >=40,000
     gallons, fittings >=1", pumps >=1/2", and valves >=1.75".
[11] Colors: Greenish-Gray
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% Thinner #2 by volume
     Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. 
     Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20
     Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system
     providing that both primer and topcoat meet their individual Certified end uses.
[12] Color: Greenish-Gray
     Number of Coats: 1
     Maximum Field Use Dry Film Thickness (in mils): 4
     Maximum Thinner: 15% Tnemec No. 49 by volume or 10% Thinner No. 3 or 10% Thinner No. 2
     Recoat Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator
     is used  
     Special Comments: Series 44-710 may be added up to 4 fl. oz/gal. 94-H2O is approved for
     use with any NSF Certified Tnemec topcoat or coating system.
[14] Colors: WH08 White, R4875A Akzo Red, B8869A Epoxoline Blue
     Number of Coats: 1
     Sequence of Coats: N/A
     Maximum Field Use Dry Film Thickness (in mils): 80
     Maximum Thinner: None
     Final Cure Time and Temperature: 24 hours at 75°F
     Special Comments: Mix ratio of Part A:Part B is 1:2 by volume.  Any Listed color of
     series N140 or N140F may be used as a topcoat or primer for Series FC22 Epoxoline.
[17] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft
     blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606
     Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695
     Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 1
     Maximum Field Use Dry Thickness(in mils): 4 mils
     Maximum Thinner: 10% No. 4 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 7 days at 75°F (entire system)
     Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use
     as an optional primer or intermediate coat with any Tnemec NSF certified primer
     and topcoat coating system provided the primer, intermediate, and topcoat meet
     their certified end uses. Part C (Series 44-700 Accelerator) is an optional additive to
     Part A in the field and may be added at up to 4 fluid ounces per gallon of Part A.
[18] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of
     NSF/ANSI/CAN 61 for pump, valve, and fitting end use.
[19] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft
     Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896
     S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston
     Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F
     Final Cure Time and Temperature: 30 days at 75°F
     Special comments: Any listed color of Series 22, FC22, N140 or 141 may be substituted as
     a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat
     meet their individual Certified end uses.  The mix ratio of Part A:Part B is 1:1 by
     volume.
[20] Colors: 1216 Greenish-Gray
     Number of Coats: 1
     Sequence of Coats: N/A
     Maximum Field Use Dry Film Thickness (in mils): 4
     Maximum Thinner: 10% Thinner No. 2
     Recoat Cure Time and Temperature: 8 hours at 75°F
     Special Comment: Series 44-710 may be added up to 4 fl. oz/gal. Approved for use as a
     primer with any NSF Certified Tnemec topcoat or coating system provided that both primer
     and topcoat meet their individual Certified end uses.
[22] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft
     Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096
     Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506
     Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red.
     Number of Coats: 2-3
     Sequence of Coats: Any combination of Listed colors
     Maximum Field Use Dry Film Thickness (in mils): 18
     Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
     Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F
     without accelerator
     Final Cure Time and Temperature: 30 days at 75°F
     Special Comments: Any Listed color of Series 22, FC22, N140, or 141 may be substituted
     as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and
     topcoat meet their individual Certified end uses.  The mix ratio of Part A:Part B is 1:1
     by volume.  Part C (Series 44-700 Accelerator) is an optional addititve to Part A in the
     field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B.
[27] This coating used with Thinner #49 is Certified for use in valves >= ¾”. This coating
     used with Thinner #2 is Certified for use in valves >= 4”. This coating used with
     Thinner #3 is Certified for use in valves >= 1.75”.



Facility : Jinshan District, Shanghai, China

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Fittings[1]
Series N140 Pota-Pox Plus[2] >= 8" CLD 23 EPOXY
Series N140F Pota-Pox Plus Fast Cure[3] >= 8" CLD 23 EPOXY

[1] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of
    NSF/ANSI/CAN 61 for pump, valve, and fitting end use.
[2] Colors: 1211 Red, 1255 Beige,15BL Tank White, 39BL Delft Blue, 35GR Black, 00WH Tnemec
    White, Y2606 Romac Yellow, B8314 Krausz Blue, B5712 Westech Blue, 11SF True Blue, B9118
    Baker Blue, A13096 Baker Dark Gray, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506
    Dezurik Blue,  A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
    Number of Coats: 2-3
    Sequence of Coats: Any combination of Listed colors
    Maximum Field Use Dry Film Thickness (in mils): 18
    Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F
    without accelerator
    Final Cure Time and Temperature: 30 days at 75°F
    Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted
    as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and
    topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1
    by volume. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the
    field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B.
[3] Colors: 1211 Red, 1255 Beige, B2506 DeZurik Blue, 15BL Tank White, 39BL Delft Blue, 35GR
    Black, 00WH Tnemec White, B7896 S-B Blue, Y2606 Romac Yellow, B5712 Blue, B2592 RAL 5009
    Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller
    Sienna Red.
    Number of Coats: 2
    Sequence of Coats: Any combination of Listed colors
    Maximum Field Use Dry film Thickness (in mils): 18
    Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75°F 
    Final Cure Time and Temperature: 30 days at 75°F
    Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted
    as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and
    topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1
    by volume.

Coatings - Mechanical Devices[1]
Series N140 Pota-Pox Plus [2] [4] CLD 23 EPOXY

[1] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of
    NSF/ANSI/CAN 61 for pump, valve, and fitting end use.
[2] Colors: 1211 Red, 1255 Beige,15BL Tank White, 39BL Delft Blue, 35GR Black, 00WH Tnemec
    White, Y2606 Romac Yellow, B8314 Krausz Blue, B5712 Westech Blue, 11SF True Blue, B9118
    Baker Blue, A13096 Baker Dark Gray, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506
    Dezurik Blue,  A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
    Number of Coats: 2-3
    Sequence of Coats: Any combination of Listed colors
    Maximum Field Use Dry Film Thickness (in mils): 18
    Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F
    without accelerator
    Final Cure Time and Temperature: 30 days at 75°F
    Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted
    as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and
    topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1
    by volume. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the
    field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B.
[4] Certified for mechanical device end use (other than pump and valve) for a maximum of 4.6
    sq. ft. per gpm.

Coatings - Pump[1]
Series N140 Pota-Pox Plus[2] >= 4" CLD 23 EPOXY
Series N140F Pota-Pox Plus Fast Cure[3] >= 4" CLD 23 EPOXY

[1] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of
    NSF/ANSI/CAN 61 for pump, valve, and fitting end use.
[2] Colors: 1211 Red, 1255 Beige,15BL Tank White, 39BL Delft Blue, 35GR Black, 00WH Tnemec
    White, Y2606 Romac Yellow, B8314 Krausz Blue, B5712 Westech Blue, 11SF True Blue, B9118
    Baker Blue, A13096 Baker Dark Gray, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506
    Dezurik Blue,  A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
    Number of Coats: 2-3
    Sequence of Coats: Any combination of Listed colors
    Maximum Field Use Dry Film Thickness (in mils): 18
    Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F
    without accelerator
    Final Cure Time and Temperature: 30 days at 75°F
    Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted
    as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and
    topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1
    by volume. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the
    field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B.
[3] Colors: 1211 Red, 1255 Beige, B2506 DeZurik Blue, 15BL Tank White, 39BL Delft Blue, 35GR
    Black, 00WH Tnemec White, B7896 S-B Blue, Y2606 Romac Yellow, B5712 Blue, B2592 RAL 5009
    Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller
    Sienna Red.
    Number of Coats: 2
    Sequence of Coats: Any combination of Listed colors
    Maximum Field Use Dry film Thickness (in mils): 18
    Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75°F 
    Final Cure Time and Temperature: 30 days at 75°F
    Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted
    as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and
    topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1
    by volume.

Coatings - Valve[1]
Series N140 Pota-Pox Plus[2] >= 4" CLD 23 EPOXY
Series N140F Pota-Pox Plus Fast Cure[3] >= 4" CLD 23 EPOXY

[1] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of
    NSF/ANSI/CAN 61 for pump, valve, and fitting end use.
[2] Colors: 1211 Red, 1255 Beige,15BL Tank White, 39BL Delft Blue, 35GR Black, 00WH Tnemec
    White, Y2606 Romac Yellow, B8314 Krausz Blue, B5712 Westech Blue, 11SF True Blue, B9118
    Baker Blue, A13096 Baker Dark Gray, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506
    Dezurik Blue,  A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red.
    Number of Coats: 2-3
    Sequence of Coats: Any combination of Listed colors
    Maximum Field Use Dry Film Thickness (in mils): 18
    Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F
    without accelerator
    Final Cure Time and Temperature: 30 days at 75°F
    Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted
    as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and
    topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1
    by volume. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the
    field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B.
[3] Colors: 1211 Red, 1255 Beige, B2506 DeZurik Blue, 15BL Tank White, 39BL Delft Blue, 35GR
    Black, 00WH Tnemec White, B7896 S-B Blue, Y2606 Romac Yellow, B5712 Blue, B2592 RAL 5009
    Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller
    Sienna Red.
    Number of Coats: 2
    Sequence of Coats: Any combination of Listed colors
    Maximum Field Use Dry film Thickness (in mils): 18
    Maximum Thinner: 5% Tnemec No. 60 Thinner by volume
    Recoat Cure Time and Temperature: 5 hours at 75°F 
    Final Cure Time and Temperature: 30 days at 75°F
    Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted
    as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and
    topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1
    by volume.


Number of matching Manufacturers is 1
Number of matching Products is 141
Processing time was 0 seconds