NSF Product and Service Listings
These NSF Official Listings are current as of Monday, July 8, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=46690&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
Tnemec Company, Inc. | |
6800 Corporate Drive | |
Kansas City, MO 64120-1372 | |
United States | |
816-474-3400 | |
Visit this company's website |
Facility : Baltimore, MD
Protective (Barrier) Materials
Water | Water | |||
Water Contact | Contact | Contact | ||
Trade Designation | Size Restriction | Temp | Material | |
Coatings - Fittings |
||||
22 Epoxoline[1] [2] | >= 1/2" | CLD 23 | EPOXY | |
N140F Pota-Pox Plus Fast Cure [2] [3] | >= 2" | CLD 23 | EPOXY | |
Series 21 Epoxoline[2] [4] | >= 1" | CLD 23 | EPOXY | |
Series 91-H2O ™ Hydro-Zinc™ [2] [6] [7] | >= 1" | CLD 23 | EPOXY | |
Series 91-H2O ™ Hydro-Zinc™ [2] [5] [6] | >= 1/2" | CLD 23 | EPOXY | |
Series 93-H20 Hydro-Zinc[8] | >= 1" | CLD 23 | PUR | |
Series 94-H2O Hydro-Zinc[2] [9] | [10] | CLD 23 | PUR | |
Series L140 Pota-Pox Plus [2] [11] | >= 1" | CLD 23 | EPOXY | |
Series L140F Pota-Pox Plus Fast Cure [2] [12] | >= 1" | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus[2] [13] | >= 2" | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus[14] [15] | >= 4" | CLD 23 | EPOXY | |
Series N140F Pota-Pox Plus Fast Cure[15] [16] | >= 4" | CLD 23 | EPOXY | |
[1] Colors: 1255 Beige, 1218 Blue, WH11 White Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 50 Maximum Thinner: 5% Thinner #2 Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 5 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass flake S211-0220. The fiberglass flake can be added up to a rate of 1% by weight after the Parts A and B are mixed together. Certified for use as a primer or topcoat with any NSF Certified Tnemec coating system provided that both primer and topcoat meet their individual certified end uses. [2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes, toluene, and ethylbenzene. [3] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592 RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Sequence of Coats: 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F (entire system) Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [4] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 1-3 Maximum Field Use Dry Thickness (in mils): 20 Maximum Thinner: 5% F041-0088 Thinner Clear by volume Recoat Cure Time and Temperature: 8 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [5] This coating used with Thinner #3 is Certified for use in pipes >=24", tanks >=1500 gallons, fittings >=1/2", pumps >=1/2", valves >=2". [6] Colors: Greenish-Gray Number of Coats: 1 Maximum Field Use Dry Thickness (in mils): 4 Maximum Thinner: 10% Thinner #2 or Thinner #3 by volume Final Cure Time/Temperature: 4 hours at 75F; 2 hours at 75F wen accelerator is used. Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl.oz/gal. Series 91-H2O Hydro-Zinc ™ is approved for use with any NSF Certified Tnemec topcoat or coatings system providing that both primer and topcoat meet their individual Certified end uses. Mix Ratio Part A:B is 70%:30% by volume. [7] This coating used with Thinner #2 is Certified for use in pipes >=24", tanks >=3000 gallons, fittings >=1", pumps >=1/2", and valves >=4". [8] Colors: Greenish-Gray Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% Thinner #2 by volume Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20 Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [9] Colors: Greenish-gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 15% Tnemec No. 49 or 10% Thinner No. 2 or 10% Thinner No. 3 by volume Final Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 94-H2O is aproved for use with any NSF Certified Tnemec topcoat or coating system. [10] This coating used with Thinner #49 is Certified for use in fittings >= 1/2". This coating used with Thinner #2 is Certified for use in fittings >= 1". This coatings used with Thinner #3 is Certified for use in fittings >= 1/2". [11] Colors: 1255 Beige, 15BL Tank White, 1211 Red, 00WH White # of coats: 2-3 # Seq Of Coats: Any combination of listed colors Max Film Thickness: 18 (Maximum of 6 mils per coat) Max Thinner: 5% Tnemec No. 49 Thinner by volume Recoat Cure Time/ Temp.: 16 hours at 75° F Final Cure Time/ Temp.: 7 days at 75° F Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be substituted as a primer or topcoat for L140 provided that both primer and topcoat meet their individual Certified end uses. Series 44-700 accelerator (Part C) may be added up to 4 fluid ounces per two mixed gallons of L140 Parts A and B. Mix ratio of A:B is 1:1 by volume. [12] Colors: 1255 Beige, 15BL Tank White, 1211 Red, 00WH White # of coats: 2-3 # Seq Of Coats: Any combination of listed colors Max Film Thickness: 18 (Maximum of 6 mils per coat) Max Thinner: 5% Tnemec No. 49 Thinner by volume Recoat Cure Time/ Temp.: 16 hours at 75° F Final Cure Time/ Temp.: 7 days at 75° F Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be substituted as a primer or topcoat for L140F provided that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A to Part B is 1:1 by volume. [13] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 1 Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F (entire system) Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [14] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096 Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F without accelerator Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any Listed color of Series 22, FC22, or N140, may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A:Part B is 1:1 by volume. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per 2 mixed gallons of parts A and B. [15] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of NSF/ANSI/CAN 61 for pump, valve, and fitting end use. [16] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896 S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any listed color of series 22, FC22, or N140 may be substituted as a primer or topcoat for the Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 1:1 by volume. |
||||
Coatings - Mechanical Devices |
||||
22 Epoxoline [1] [2] | [26] | CLD 23 | EPOXY | |
Series 21 Epoxoline[2] [4] | [23] | CLD 23 | EPOXY | |
Series 91-H2O™ Hydro-Zinc™ [2] [5] [6] [7] | [24] | CLD 23 | PUR | |
Series 93-H20 Hydro-Zinc[8] | [27] | CLD 23 | PUR | |
Series 94-H2O Hydro Zinc [2] [9] | [24] [25] | CLD 23 | PUR | |
Series N140 Pota-Pox Plus[14] [15] | [22] | CLD 23 | EPOXY | |
Series N140F Pota-Pox Plus Fast Cure[15] [16] | [22] | CLD 23 | EPOXY | |
[1] Colors: 1255 Beige, 1218 Blue, WH11 White Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 50 Maximum Thinner: 5% Thinner #2 Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 5 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass flake S211-0220. The fiberglass flake can be added up to a rate of 1% by weight after the Parts A and B are mixed together. Certified for use as a primer or topcoat with any NSF Certified Tnemec coating system provided that both primer and topcoat meet their individual certified end uses. [2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes, toluene, and ethylbenzene. [4] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 1-3 Maximum Field Use Dry Thickness (in mils): 20 Maximum Thinner: 5% F041-0088 Thinner Clear by volume Recoat Cure Time and Temperature: 8 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [5] This coating used with Thinner #3 is Certified for use in pipes >=24", tanks >=1500 gallons, fittings >=1/2", pumps >=1/2", valves >=2". [6] Colors: Greenish-Gray Number of Coats: 1 Maximum Field Use Dry Thickness (in mils): 4 Maximum Thinner: 10% Thinner #2 or Thinner #3 by volume Final Cure Time/Temperature: 4 hours at 75F; 2 hours at 75F wen accelerator is used. Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl.oz/gal. Series 91-H2O Hydro-Zinc ™ is approved for use with any NSF Certified Tnemec topcoat or coatings system providing that both primer and topcoat meet their individual Certified end uses. Mix Ratio Part A:B is 70%:30% by volume. [7] This coating used with Thinner #2 is Certified for use in pipes >=24", tanks >=3000 gallons, fittings >=1", pumps >=1/2", and valves >=4". [8] Colors: Greenish-Gray Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% Thinner #2 by volume Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20 Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [9] Colors: Greenish-gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 15% Tnemec No. 49 or 10% Thinner No. 2 or 10% Thinner No. 3 by volume Final Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 94-H2O is aproved for use with any NSF Certified Tnemec topcoat or coating system. [14] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096 Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F without accelerator Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any Listed color of Series 22, FC22, or N140, may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A:Part B is 1:1 by volume. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per 2 mixed gallons of parts A and B. [15] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of NSF/ANSI/CAN 61 for pump, valve, and fitting end use. [16] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896 S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any listed color of series 22, FC22, or N140 may be substituted as a primer or topcoat for the Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 1:1 by volume. [22] Certified for mechanical device end use (other than pump and valve) for a maximum of 4.6 sq. ft. per gpm. [23] Certified for mechanical device end use (other than pump and valve) for a maximum of 50.5 sq. ft. per gpm. [24] Certified for mechanical device end use (other than pump and valve) for a maximum of 151 sq. ft. per gpm when used with Thinner #2 and 189 sq. ft. per gpm when used with Thinner #3. [25] This coating used with Thinner #49 is Certified for mechanical device end use (other than pump and valve) for a maximum of 310 sq. ft. per gpm. [26] Certified for mechanical device end use (other than pump and valve) for a maximum of 635 sq. ft. per gpm. [27] Certified for mechanical device end use (other than pump and valve) for a maximum of 151 sq. ft per gpm. |
||||
Coatings - Pipe |
||||
22 Epoxoline[1] [2] | >= 10" | CLD 23 | EPOXY | |
N140F Pota-Pox Plus Fast Cure [2] [3] | >= 36" | CLD 23 | EPOXY | |
Series 91-H2O ™ Hydro-Zinc™ [2] [5] [6] [7] | >= 24" | CLD 23 | EPOXY | |
Series 93-H20 Hydro-Zinc[8] | >= 24" | CLD 23 | PUR | |
Series 94-H2O Hydro-Zinc[2] [9] | [17] | CLD 23 | PUR | |
Series N140 Pota-Pox Plus[2] [13] | >= 36" | CLD 23 | EPOXY | |
[1] Colors: 1255 Beige, 1218 Blue, WH11 White Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 50 Maximum Thinner: 5% Thinner #2 Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 5 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass flake S211-0220. The fiberglass flake can be added up to a rate of 1% by weight after the Parts A and B are mixed together. Certified for use as a primer or topcoat with any NSF Certified Tnemec coating system provided that both primer and topcoat meet their individual certified end uses. [2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes, toluene, and ethylbenzene. [3] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592 RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Sequence of Coats: 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F (entire system) Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [5] This coating used with Thinner #3 is Certified for use in pipes >=24", tanks >=1500 gallons, fittings >=1/2", pumps >=1/2", valves >=2". [6] Colors: Greenish-Gray Number of Coats: 1 Maximum Field Use Dry Thickness (in mils): 4 Maximum Thinner: 10% Thinner #2 or Thinner #3 by volume Final Cure Time/Temperature: 4 hours at 75F; 2 hours at 75F wen accelerator is used. Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl.oz/gal. Series 91-H2O Hydro-Zinc ™ is approved for use with any NSF Certified Tnemec topcoat or coatings system providing that both primer and topcoat meet their individual Certified end uses. Mix Ratio Part A:B is 70%:30% by volume. [7] This coating used with Thinner #2 is Certified for use in pipes >=24", tanks >=3000 gallons, fittings >=1", pumps >=1/2", and valves >=4". [8] Colors: Greenish-Gray Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% Thinner #2 by volume Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20 Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [9] Colors: Greenish-gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 15% Tnemec No. 49 or 10% Thinner No. 2 or 10% Thinner No. 3 by volume Final Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 94-H2O is aproved for use with any NSF Certified Tnemec topcoat or coating system. [13] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 1 Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F (entire system) Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [17] This coating used with Thinner #49 is Certified for use in pipes >= 18". This coating used with Thinner #2 and Thinner #3 is Certified for use in pipes >=24". |
||||
Coatings - Pump |
||||
22 Epoxoline[1] [2] | >= 1/2" | CLD 23 | EPOXY | |
N140F Pota-Pox Plus Fast Cure[2] [3] | >= 4" | CLD 23 | EPOXY | |
Series 21 Epoxoline[2] [4] | >= 4” | CLD 23 | EPOXY | |
Series 91-H2O ™ Hydro-Zinc™ [2] [5] [6] [7] | >= 1/2" | CLD 23 | EPOXY | |
Series 93-H20 Hydro-Zinc[8] | >= 1/2" | CLD 23 | PUR | |
Series 94-H2O Hydro-Zinc[2] [9] [18] | >1/2" | CLD 23 | PUR | |
Series N140 Pota-Pox Plus[14] [15] | >= 4" | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus [2] [13] | >= 4" | CLD 23 | EPOXY | |
Series N140F Pota-Pox Plus Fast Cure[15] [16] | >= 4" | CLD 23 | EPOXY | |
[1] Colors: 1255 Beige, 1218 Blue, WH11 White Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 50 Maximum Thinner: 5% Thinner #2 Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 5 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass flake S211-0220. The fiberglass flake can be added up to a rate of 1% by weight after the Parts A and B are mixed together. Certified for use as a primer or topcoat with any NSF Certified Tnemec coating system provided that both primer and topcoat meet their individual certified end uses. [2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes, toluene, and ethylbenzene. [3] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592 RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Sequence of Coats: 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F (entire system) Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [4] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 1-3 Maximum Field Use Dry Thickness (in mils): 20 Maximum Thinner: 5% F041-0088 Thinner Clear by volume Recoat Cure Time and Temperature: 8 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [5] This coating used with Thinner #3 is Certified for use in pipes >=24", tanks >=1500 gallons, fittings >=1/2", pumps >=1/2", valves >=2". [6] Colors: Greenish-Gray Number of Coats: 1 Maximum Field Use Dry Thickness (in mils): 4 Maximum Thinner: 10% Thinner #2 or Thinner #3 by volume Final Cure Time/Temperature: 4 hours at 75F; 2 hours at 75F wen accelerator is used. Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl.oz/gal. Series 91-H2O Hydro-Zinc ™ is approved for use with any NSF Certified Tnemec topcoat or coatings system providing that both primer and topcoat meet their individual Certified end uses. Mix Ratio Part A:B is 70%:30% by volume. [7] This coating used with Thinner #2 is Certified for use in pipes >=24", tanks >=3000 gallons, fittings >=1", pumps >=1/2", and valves >=4". [8] Colors: Greenish-Gray Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% Thinner #2 by volume Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20 Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [9] Colors: Greenish-gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 15% Tnemec No. 49 or 10% Thinner No. 2 or 10% Thinner No. 3 by volume Final Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 94-H2O is aproved for use with any NSF Certified Tnemec topcoat or coating system. [13] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 1 Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F (entire system) Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [14] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096 Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F without accelerator Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any Listed color of Series 22, FC22, or N140, may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A:Part B is 1:1 by volume. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per 2 mixed gallons of parts A and B. [15] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of NSF/ANSI/CAN 61 for pump, valve, and fitting end use. [16] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896 S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any listed color of series 22, FC22, or N140 may be substituted as a primer or topcoat for the Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 1:1 by volume. [18] This coating used with Thinner #49, Thinner #2 and Thinner #3 is Certified for use in pumps >= 1/2". |
||||
Coatings - Tank |
||||
22 Epoxoline[1] [2] | >= 50 gal. | CLD 23 | EPOXY | |
N140F Pota-Pox Plus Fast Cure [2] [3] | >= 1,500 gal. | CLD 23 | EPOXY | |
Series 21 Epoxoline [2] [4] | >= 90,000 gal. | CLD 23 | EPOXY | |
Series 406 Elastoshield[2] [19] | >= 50,000 gal. | CLD 23 | PUR | |
Series 91-H2O ™ Hydro-Zinc™ [2] [5] [6] | >= 1500 gal. | CLD 23 | EPOXY | |
Series 91-H2O ™ Hydro-Zinc™ [2] [6] [7] | >= 3000 gal. | CLD 23 | EPOXY | |
Series 93-H20 Hydro-Zinc[8] | >= 3,000 gal | CLD 23 | PUR | |
Series 94-H2O Hydro Zinc[2] [9] | [20] | CLD 23 | PUR | |
Series L140 Pota-Pox Plus [2] [12] | >= 50,000 gal. | CLD 23 | EPOXY | |
Series L140F Pota-Pox Plus Fast Cure [2] [12] | >= 50,000 gal. | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus [2] [13] | >= 1,500 gal. | CLD 23 | EPOXY | |
[1] Colors: 1255 Beige, 1218 Blue, WH11 White Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 50 Maximum Thinner: 5% Thinner #2 Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 5 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass flake S211-0220. The fiberglass flake can be added up to a rate of 1% by weight after the Parts A and B are mixed together. Certified for use as a primer or topcoat with any NSF Certified Tnemec coating system provided that both primer and topcoat meet their individual certified end uses. [2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes, toluene, and ethylbenzene. [3] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592 RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Sequence of Coats: 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F (entire system) Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [4] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 1-3 Maximum Field Use Dry Thickness (in mils): 20 Maximum Thinner: 5% F041-0088 Thinner Clear by volume Recoat Cure Time and Temperature: 8 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [5] This coating used with Thinner #3 is Certified for use in pipes >=24", tanks >=1500 gallons, fittings >=1/2", pumps >=1/2", valves >=2". [6] Colors: Greenish-Gray Number of Coats: 1 Maximum Field Use Dry Thickness (in mils): 4 Maximum Thinner: 10% Thinner #2 or Thinner #3 by volume Final Cure Time/Temperature: 4 hours at 75F; 2 hours at 75F wen accelerator is used. Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl.oz/gal. Series 91-H2O Hydro-Zinc ™ is approved for use with any NSF Certified Tnemec topcoat or coatings system providing that both primer and topcoat meet their individual Certified end uses. Mix Ratio Part A:B is 70%:30% by volume. [7] This coating used with Thinner #2 is Certified for use in pipes >=24", tanks >=3000 gallons, fittings >=1", pumps >=1/2", and valves >=4". [8] Colors: Greenish-Gray Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% Thinner #2 by volume Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20 Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [9] Colors: Greenish-gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 15% Tnemec No. 49 or 10% Thinner No. 2 or 10% Thinner No. 3 by volume Final Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 94-H2O is aproved for use with any NSF Certified Tnemec topcoat or coating system. [12] Colors: 1255 Beige, 15BL Tank White, 1211 Red, 00WH White # of coats: 2-3 # Seq Of Coats: Any combination of listed colors Max Film Thickness: 18 (Maximum of 6 mils per coat) Max Thinner: 5% Tnemec No. 49 Thinner by volume Recoat Cure Time/ Temp.: 16 hours at 75° F Final Cure Time/ Temp.: 7 days at 75° F Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be substituted as a primer or topcoat for L140F provided that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A to Part B is 1:1 by volume. [13] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 1 Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F (entire system) Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [19] Colors: WH06 Off-White Number of Coats: 1-2 Sequence of Coats: Primer (optional), Series 406 Elastoshield (topcoat) Maximum Field Use Dry Film Thickness (in mils): Topcoat-75 Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 72 hours at 75°F Special Comments: Mix ratio for primers must meet their individual certified parameters. Mix ratio of A:B is 1:2 by volume for Topcoat. Certified for use as a topcoat with any Tnemec NSF Certified coating system provided both primer and topcoat meet their individual certified end uses. [20] This coating used with Thinner #49 is Certified for use in tanks >= 400 gallons. This coating used with Thinner #2 is Certified for use in tank >=3000 gallons. This coating used with Thinner #3 is Certified for use in tanks >=1500 gallons. |
||||
Coatings - Valve |
||||
22 Epoxoline[1] [2] | >= 1/2" | CLD 23 | EPOXY | |
N140F Pota-Pox Plus Fast Cure[2] [3] | >= 4" | CLD 23 | EPOXY | |
Series 21 Epoxoline[2] [4] | >= 4" | CLD 23 | EPOXY | |
Series 406 Elastoshield[2] [19] | >= 4" | CLD 23 | PUR | |
Series 91-H2O ™ Hydro-Zinc™ [2] [5] [6] | >= 2" | CLD 23 | EPOXY | |
Series 91-H2O™ Hydro-Zinc™ [2] [6] [7] | >= 4" | CLD 23 | EPOXY | |
Series 93-H20 Hydro-Zinc[8] | >= 4" | CLD 23 | PUR | |
Series 94-H2O Hydro-Zinc[2] [9] | [21] | CLD 23 | PUR | |
Series N140 Pota-Pox Plus[14] [15] | >= 4" | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus [2] [13] | >= 4" | CLD 23 | EPOXY | |
Series N140F Pota-Pox Plus Fast Cure[15] [16] | >= 4" | CLD 23 | EPOXY | |
[1] Colors: 1255 Beige, 1218 Blue, WH11 White Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 50 Maximum Thinner: 5% Thinner #2 Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 5 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass flake S211-0220. The fiberglass flake can be added up to a rate of 1% by weight after the Parts A and B are mixed together. Certified for use as a primer or topcoat with any NSF Certified Tnemec coating system provided that both primer and topcoat meet their individual certified end uses. [2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes, toluene, and ethylbenzene. [3] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592 RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Sequence of Coats: 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F (entire system) Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [4] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 1-3 Maximum Field Use Dry Thickness (in mils): 20 Maximum Thinner: 5% F041-0088 Thinner Clear by volume Recoat Cure Time and Temperature: 8 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [5] This coating used with Thinner #3 is Certified for use in pipes >=24", tanks >=1500 gallons, fittings >=1/2", pumps >=1/2", valves >=2". [6] Colors: Greenish-Gray Number of Coats: 1 Maximum Field Use Dry Thickness (in mils): 4 Maximum Thinner: 10% Thinner #2 or Thinner #3 by volume Final Cure Time/Temperature: 4 hours at 75F; 2 hours at 75F wen accelerator is used. Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl.oz/gal. Series 91-H2O Hydro-Zinc ™ is approved for use with any NSF Certified Tnemec topcoat or coatings system providing that both primer and topcoat meet their individual Certified end uses. Mix Ratio Part A:B is 70%:30% by volume. [7] This coating used with Thinner #2 is Certified for use in pipes >=24", tanks >=3000 gallons, fittings >=1", pumps >=1/2", and valves >=4". [8] Colors: Greenish-Gray Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% Thinner #2 by volume Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20 Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [9] Colors: Greenish-gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 15% Tnemec No. 49 or 10% Thinner No. 2 or 10% Thinner No. 3 by volume Final Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. 94-H2O is aproved for use with any NSF Certified Tnemec topcoat or coating system. [13] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 1 Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F (entire system) Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [14] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096 Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F without accelerator Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any Listed color of Series 22, FC22, or N140, may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A:Part B is 1:1 by volume. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per 2 mixed gallons of parts A and B. [15] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of NSF/ANSI/CAN 61 for pump, valve, and fitting end use. [16] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896 S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any listed color of series 22, FC22, or N140 may be substituted as a primer or topcoat for the Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 1:1 by volume. [19] Colors: WH06 Off-White Number of Coats: 1-2 Sequence of Coats: Primer (optional), Series 406 Elastoshield (topcoat) Maximum Field Use Dry Film Thickness (in mils): Topcoat-75 Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 72 hours at 75°F Special Comments: Mix ratio for primers must meet their individual certified parameters. Mix ratio of A:B is 1:2 by volume for Topcoat. Certified for use as a topcoat with any Tnemec NSF Certified coating system provided both primer and topcoat meet their individual certified end uses. [21] This coating used with Thinner #49 is Certified for use in valves >=1/2". This coatings used with Thinner #2 is Certified for use in valves >= 4". This coating used with Thinner #3 is Certified for use in valves >= 2". |
Facility : North Kansas City, MO
Protective (Barrier) Materials
Water | Water | |||
Water Contact | Contact | Contact | ||
Trade Designation | Size Restriction | Temp | Material | |
Coatings - Fittings |
||||
22 Epoxoline[1] [2] | >= 6" | CLD 23 | EPOXY | |
F098-0H20 Hydro-Zinc[2] [3] | >= 1" | CLD 23 | EPOXY | |
N140F Pota-Pox Plus Fast Cure[2] [4] | >= 2" | CLD 23 | EPOXY | |
Series 1220 Tnemec Epoxy[5] | >= 1/2" | CLD 23 | EPOXY | |
Series 21 Epoxoline[2] [7] | >= 3/4" | CLD 23 | EPOXY | |
Series 21 Epoxoline[2] [6] | >= 1/2" | CLD 23 | EPOXY | |
Series 91-H2O™ Hydro-Zinc™[2] [8] [9] [10] | >= 1" | CLD 23 | PUR | |
Series 93-H20 Hydro-Zinc[11] | >= 1" | CLD 23 | PUR | |
Series 94-H2O Hydro-Zinc[2] [12] | [13] | CLD 23 | PUR | |
Series FC22 Epoxoline[2] [14] | >= 1/2" | CLD 23 | EPOXY | |
Series L140 Pota-Pox Plus[2] [15] | >= 1" | CLD 23 | EPOXY | |
Series L140F Pota-Pox Plus Fast Cure[2] [16] | >= 1" | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus[18] [22] | >= 4" | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus [2] [17] | >= 2" | CLD 23 | EPOXY | |
Series N140F Pota-Pox Plus Fast Cure[18] [19] | >= 4" | CLD 23 | EPOXY | |
[1] Colors: 1255 Beige, 1218 Blue, WH11 White Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 50 Maximum Thinner: 5% Thinner #2 Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 5 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass flake S211-0220. The fiberglass flake can be added up to a rate of 1% by weight after the Parts A and B are mixed together. Certified for use as a primer or topcoat with any NSF Certified Tnemec coating system provided that both primer and topcoat meet their individual certified end uses. [2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes, toluene, and ethylbenzene. [3] Colors: Greenish Gray Number of Coats: 1 Maximum Field Use Dry Thickness (in mils): 4mils Maximum Thinner: 25% Water Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Series 44-780 Accelerator may be added up to 1 fl. oz/gal. Series 98-H2O Hydro-Zinc is approved for use as a primer with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Cure for Series 98-H2O Hydro-Zinc primer is 5 hours at 75F. Top-coat is then applied. Final cure is 7 days. Mix ratio of Part A:B:C is 1.4:0.6:1 by volume. [4] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592 RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Sequence of Coats: 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F (entire system) Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [5] Colors: White Number of Coats: 1-3 Maximum Field Use Dry Thickness (in mils): 18 mils Maximum Thinner: 15% water Recoat Cure Time and Temperature: 6 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Series 44-700 Accelerator may be added up to 1 fl. oz./gal. Series 1220 Tnemec Epoxy is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 2:1 by volume. [6] Colors: WH16 Off-White, 1255 Beige, 39BL Delft Blue, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 2 Maximum Field Use Dry Thickness(in mils): 20 mils Maximum Thinner: None Recoat Cure Time and Temperature: 16 hours at 75F Final Cure Time/Temperature: 30 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. This is for pipe, fitting, pump and valve end use. [7] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 1-3 Maximum Field Use Dry Thickness(in mils): 20 Maximum Thinner: 5% F041-0088 Thinner Clear by volume Recoat Cure Time and Temperature: 8 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [8] Colors: Greenish-gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 10% Thinner No. 2 or 10% Thinner No. 3 by volume Final Cure Time and Temperature: 4 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. Series 91-H2O™ Hydro-Zinc™ is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 70%:30% by volume. [9] This coating used with Thinner #2 is Certified for use in pipes >=96", tanks >=50,000 gallons, fittings >=1", pumps >=1", and valves >=4". [10] This coatings used with Thinner #3 is Certified for use in pipes >=96", tanks >=40,000 gallons, fittings >=1", pumps >=1/2", and valves >=1.75". [11] Colors: Greenish-Gray Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% Thinner #2 by volume Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20 Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [12] Color: Greenish-Gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 15% Tnemec No. 49 by volume or 10% Thinner No. 3 or 10% Thinner No. 2 Recoat Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 may be added up to 4 fl. oz/gal. 94-H2O is approved for use with any NSF Certified Tnemec topcoat or coating system. [13] This coating used with Thinner #49 is Certified for use in fittings >= ½”. This coating used with Thinner #2 and #3 is Certified for use in fittings >= 1”. [14] Colors: WH08 White, R4875A Akzo Red, B8869A Epoxoline Blue Number of Coats: 1 Sequence of Coats: N/A Maximum Field Use Dry Film Thickness (in mils): 80 Maximum Thinner: None Final Cure Time and Temperature: 24 hours at 75°F Special Comments: Mix ratio of Part A:Part B is 1:2 by volume. Any Listed color of series N140 or N140F may be used as a topcoat or primer for Series FC22 Epoxoline. [15] Colors: 00WH White, 1211 Red, 1255 Beige, 15BL Tank White Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 (maximum of 6 mils per coat) Maximum Thinner: 5% Tnemec No. 49 Thinner by volume Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be substituted as a primer or topcoat for L140 provided that both primer and topcoat meet their individual Certified end uses. Series 44-700 accelerator (Part C) may be added up to 4 fluid ounces per two mixed gallons of L140 Parts A and B. Mix ratio of A:B is 1:1 by volume. [16] Colors: 1255 Beige, 15BL Tank White, 1211 Red, 00WH White Number of Coats: 2-3 Sequence of coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 (maximum of 6 mils per coat) Maximum Thinner: 5% Tnemec No. 49 by volume Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be substituted as a primer or topcoat for L140F provided that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A to Part B is 1:1 by volume. [17] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F (entire system) Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per gallon of Part A. [18] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of NSF/ANSI/CAN 61 for pump, valve, and fitting end use. [19] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896 S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 30 days at 75°F Special comments: Any listed color of Series 22, FC22, N140 or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A:Part B is 1:1 by volume. [22] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096 Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F without accelerator Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any Listed color of Series 22, FC22, N140, or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A:Part B is 1:1 by volume. Part C (Series 44-700 Accelerator) is an optional addititve to Part A in the field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B. |
||||
Coatings - Mechanical Devices |
||||
22 Epoxoline [1] [2] | [31] | CLD 23 | EPOXY | |
Series 21 Epoxoline [2] [7] | [29] | CLD 23 | EPOXY | |
Series 91-H2O™ Hydro-Zinc™[2] [9] [10] [12] | [30] | CLD 23 | PUR | |
Series 93-H20 Hydro-Zinc[11] | [33] | CLD 23 | PUR | |
Series 94-H2O Hydro Zinc [2] [12] | [30] [32] | CLD 23 | PUR | |
Series N140 Pota-Pox Plus [18] [22] | [28] | CLD 23 | EPOXY | |
Series N140F Pota-Pox Plus Fast Cure[17] [19] | [28] | CLD 23 | EPOXY | |
[1] Colors: 1255 Beige, 1218 Blue, WH11 White Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 50 Maximum Thinner: 5% Thinner #2 Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 5 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass flake S211-0220. The fiberglass flake can be added up to a rate of 1% by weight after the Parts A and B are mixed together. Certified for use as a primer or topcoat with any NSF Certified Tnemec coating system provided that both primer and topcoat meet their individual certified end uses. [2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes, toluene, and ethylbenzene. [7] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 1-3 Maximum Field Use Dry Thickness(in mils): 20 Maximum Thinner: 5% F041-0088 Thinner Clear by volume Recoat Cure Time and Temperature: 8 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [9] This coating used with Thinner #2 is Certified for use in pipes >=96", tanks >=50,000 gallons, fittings >=1", pumps >=1", and valves >=4". [10] This coatings used with Thinner #3 is Certified for use in pipes >=96", tanks >=40,000 gallons, fittings >=1", pumps >=1/2", and valves >=1.75". [11] Colors: Greenish-Gray Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% Thinner #2 by volume Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20 Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [12] Color: Greenish-Gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 15% Tnemec No. 49 by volume or 10% Thinner No. 3 or 10% Thinner No. 2 Recoat Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 may be added up to 4 fl. oz/gal. 94-H2O is approved for use with any NSF Certified Tnemec topcoat or coating system. [17] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F (entire system) Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per gallon of Part A. [18] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of NSF/ANSI/CAN 61 for pump, valve, and fitting end use. [19] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896 S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 30 days at 75°F Special comments: Any listed color of Series 22, FC22, N140 or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A:Part B is 1:1 by volume. [22] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096 Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F without accelerator Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any Listed color of Series 22, FC22, N140, or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A:Part B is 1:1 by volume. Part C (Series 44-700 Accelerator) is an optional addititve to Part A in the field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B. [28] Certified for mechanical device end use (other than pump and valve) for a maximum of 4.6 sq. ft. per gpm. [29] Certified for mechanical device end use (other than pump and valve) for a maximum of 189 sq. ft. per gpm. [30] Certified for mechanical device end use (other than pump and valve) for a minimum of 60 sq. ft. per gpm when used with Thinner #2 and 64 sq. ft. per gpm when used with Thinner #3. [31] Certified for mechanical device end use (other than pump and valve) for a maximum of 249 sq. ft. per gpm. [32] This coating used with Thinner #49 is Certified for mechanical device end use (other than pump and valve) for a maximum of 189 sq. Ft. per gpm. [33] Certified for mechanical device end use (other than pump and valve) for a maximum of 60 sq. ft per gpm. |
||||
Coatings - Pipe |
||||
22 Epoxoline[1] [2] | >= 24" | CLD 23 | EPOXY | |
F098-0H20 Hydro-Zinc[2] [3] | >= 120" | CLD 23 | EPOXY | |
N140F Pota-Pox Plus Fast Cure [2] [4] | >= 42" | CLD 23 | EPOXY | |
Series 1 Omnithane 1216 Greenish-Gray[2] [20] | >= 36" | CLD 23 | PUR | |
Series 1220 Tnemec Epoxy[2] [5] | >= 6" | CLD 23 | EPOXY | |
Series 21 Epoxoline[2] [6] | >= 18" | CLD 23 | EPOXY | |
Series 91-H2O™ Hydro-Zinc™[2] [8] [9] [10] | >= 96" | CLD 23 | PUR | |
Series 93-H20 Hydro-Zinc [11] | >= 96" | CLD 23 | PUR | |
Series 94-H2O Hydro-Zinc[2] [12] | [21] | CLD 23 | PUR | |
Series FC22 Epoxoline[2] [14] | >= 8" | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus [2] [17] | >= 42" | CLD 23 | EPOXY | |
[1] Colors: 1255 Beige, 1218 Blue, WH11 White Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 50 Maximum Thinner: 5% Thinner #2 Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 5 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass flake S211-0220. The fiberglass flake can be added up to a rate of 1% by weight after the Parts A and B are mixed together. Certified for use as a primer or topcoat with any NSF Certified Tnemec coating system provided that both primer and topcoat meet their individual certified end uses. [2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes, toluene, and ethylbenzene. [3] Colors: Greenish Gray Number of Coats: 1 Maximum Field Use Dry Thickness (in mils): 4mils Maximum Thinner: 25% Water Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Series 44-780 Accelerator may be added up to 1 fl. oz/gal. Series 98-H2O Hydro-Zinc is approved for use as a primer with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Cure for Series 98-H2O Hydro-Zinc primer is 5 hours at 75F. Top-coat is then applied. Final cure is 7 days. Mix ratio of Part A:B:C is 1.4:0.6:1 by volume. [4] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592 RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Sequence of Coats: 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F (entire system) Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [5] Colors: White Number of Coats: 1-3 Maximum Field Use Dry Thickness (in mils): 18 mils Maximum Thinner: 15% water Recoat Cure Time and Temperature: 6 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Series 44-700 Accelerator may be added up to 1 fl. oz./gal. Series 1220 Tnemec Epoxy is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 2:1 by volume. [6] Colors: WH16 Off-White, 1255 Beige, 39BL Delft Blue, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 2 Maximum Field Use Dry Thickness(in mils): 20 mils Maximum Thinner: None Recoat Cure Time and Temperature: 16 hours at 75F Final Cure Time/Temperature: 30 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. This is for pipe, fitting, pump and valve end use. [8] Colors: Greenish-gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 10% Thinner No. 2 or 10% Thinner No. 3 by volume Final Cure Time and Temperature: 4 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. Series 91-H2O™ Hydro-Zinc™ is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 70%:30% by volume. [9] This coating used with Thinner #2 is Certified for use in pipes >=96", tanks >=50,000 gallons, fittings >=1", pumps >=1", and valves >=4". [10] This coatings used with Thinner #3 is Certified for use in pipes >=96", tanks >=40,000 gallons, fittings >=1", pumps >=1/2", and valves >=1.75". [11] Colors: Greenish-Gray Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% Thinner #2 by volume Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20 Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [12] Color: Greenish-Gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 15% Tnemec No. 49 by volume or 10% Thinner No. 3 or 10% Thinner No. 2 Recoat Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 may be added up to 4 fl. oz/gal. 94-H2O is approved for use with any NSF Certified Tnemec topcoat or coating system. [14] Colors: WH08 White, R4875A Akzo Red, B8869A Epoxoline Blue Number of Coats: 1 Sequence of Coats: N/A Maximum Field Use Dry Film Thickness (in mils): 80 Maximum Thinner: None Final Cure Time and Temperature: 24 hours at 75°F Special Comments: Mix ratio of Part A:Part B is 1:2 by volume. Any Listed color of series N140 or N140F may be used as a topcoat or primer for Series FC22 Epoxoline. [17] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F (entire system) Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per gallon of Part A. [20] Colors: 1216 Greenish-Gray Number of Coats: 1 Sequence of Coats: N/A Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 10% Thinner No. 2 Recoat Cure Time and Temperature: 8 hours at 75°F Special Comment: Series 44-710 may be added up to 4 fl. oz/gal. Approved for use as a primer with any NSF Certified Tnemec topcoat or coating system provided that both primer and topcoat meet their individual Certified end uses. [21] This coating used with Thinner #49 is Certified for use in pipes <= 22”. This coating used with Thinner #2 and #3 is Certified for use in pipes >= 96”. |
||||
Coatings - Pump |
||||
22 Epoxoline[1] [2] | >= 4" | CLD 23 | EPOXY | |
F098-0H20 Hydro-Zinc[2] [3] | >= 4" | CLD 23 | EPOXY | |
N140F Pota-Pox Plus Fast Cure[2] [4] | >= 4" | CLD 23 | EPOXY | |
Series 1220 Tnemec Epoxy[2] [5] | >= 1 1/2" | CLD 23 | EPOXY | |
Series 21 Epoxoline[2] [7] | >= 4" | CLD 23 | EPOXY | |
Series 21 Epoxoline[2] [6] | >= 1/2" | CLD 23 | EPOXY | |
Series 91-H2O ™ Hydro-Zinc™ [2] [8] [10] | >= 1/2" | CLD 23 | PUR | |
Series 91-H2O™ Hydro-Zinc™[2] [8] [9] | >= 1" | CLD 23 | PUR | |
Series 93-H20 Hydro-Zinc [11] | >= 1" | CLD 23 | PUR | |
Series 94-H2O Hydro-Zinc[2] [12] | [23] | CLD 23 | PUR | |
Series FC22 Epoxoline[2] [14] | >= 2" | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus[18] [22] | >= 4" | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus[2] [17] | >= 4" | CLD 23 | EPOXY | |
Series N140F Pota-Pox Plus Fast Cure[18] [19] | >= 4" | CLD 23 | EPOXY | |
[1] Colors: 1255 Beige, 1218 Blue, WH11 White Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 50 Maximum Thinner: 5% Thinner #2 Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 5 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass flake S211-0220. The fiberglass flake can be added up to a rate of 1% by weight after the Parts A and B are mixed together. Certified for use as a primer or topcoat with any NSF Certified Tnemec coating system provided that both primer and topcoat meet their individual certified end uses. [2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes, toluene, and ethylbenzene. [3] Colors: Greenish Gray Number of Coats: 1 Maximum Field Use Dry Thickness (in mils): 4mils Maximum Thinner: 25% Water Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Series 44-780 Accelerator may be added up to 1 fl. oz/gal. Series 98-H2O Hydro-Zinc is approved for use as a primer with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Cure for Series 98-H2O Hydro-Zinc primer is 5 hours at 75F. Top-coat is then applied. Final cure is 7 days. Mix ratio of Part A:B:C is 1.4:0.6:1 by volume. [4] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592 RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Sequence of Coats: 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F (entire system) Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [5] Colors: White Number of Coats: 1-3 Maximum Field Use Dry Thickness (in mils): 18 mils Maximum Thinner: 15% water Recoat Cure Time and Temperature: 6 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Series 44-700 Accelerator may be added up to 1 fl. oz./gal. Series 1220 Tnemec Epoxy is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 2:1 by volume. [6] Colors: WH16 Off-White, 1255 Beige, 39BL Delft Blue, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 2 Maximum Field Use Dry Thickness(in mils): 20 mils Maximum Thinner: None Recoat Cure Time and Temperature: 16 hours at 75F Final Cure Time/Temperature: 30 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. This is for pipe, fitting, pump and valve end use. [7] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 1-3 Maximum Field Use Dry Thickness(in mils): 20 Maximum Thinner: 5% F041-0088 Thinner Clear by volume Recoat Cure Time and Temperature: 8 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [8] Colors: Greenish-gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 10% Thinner No. 2 or 10% Thinner No. 3 by volume Final Cure Time and Temperature: 4 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. Series 91-H2O™ Hydro-Zinc™ is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 70%:30% by volume. [9] This coating used with Thinner #2 is Certified for use in pipes >=96", tanks >=50,000 gallons, fittings >=1", pumps >=1", and valves >=4". [10] This coatings used with Thinner #3 is Certified for use in pipes >=96", tanks >=40,000 gallons, fittings >=1", pumps >=1/2", and valves >=1.75". [11] Colors: Greenish-Gray Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% Thinner #2 by volume Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20 Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [12] Color: Greenish-Gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 15% Tnemec No. 49 by volume or 10% Thinner No. 3 or 10% Thinner No. 2 Recoat Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 may be added up to 4 fl. oz/gal. 94-H2O is approved for use with any NSF Certified Tnemec topcoat or coating system. [14] Colors: WH08 White, R4875A Akzo Red, B8869A Epoxoline Blue Number of Coats: 1 Sequence of Coats: N/A Maximum Field Use Dry Film Thickness (in mils): 80 Maximum Thinner: None Final Cure Time and Temperature: 24 hours at 75°F Special Comments: Mix ratio of Part A:Part B is 1:2 by volume. Any Listed color of series N140 or N140F may be used as a topcoat or primer for Series FC22 Epoxoline. [17] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F (entire system) Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per gallon of Part A. [18] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of NSF/ANSI/CAN 61 for pump, valve, and fitting end use. [19] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896 S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 30 days at 75°F Special comments: Any listed color of Series 22, FC22, N140 or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A:Part B is 1:1 by volume. [22] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096 Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F without accelerator Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any Listed color of Series 22, FC22, N140, or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A:Part B is 1:1 by volume. Part C (Series 44-700 Accelerator) is an optional addititve to Part A in the field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B. [23] This coating used with Thinner #49 is Certified for use in pumps >= ¾”. This coating used with Thinner #2 is Certified for use in pumps >= 1”. This coating used with Thinner #3 is Certified for use in pumps >= ½”. |
||||
Coatings - Tank |
||||
22 Epoxoline[1] [2] | >= 700 gal. | CLD 23 | EPOXY | |
F098-0H20 Hydro-Zinc[2] [3] | >= 70,000 gal. | CLD 23 | EPOXY | |
N140F Pota-Pox Plus Fast Cure[2] [4] | >= 4,000 gal. | CLD 23 | EPOXY | |
Series 1 Omnithane 1216 Greenish-Gray[2] [20] | >= 1000 gal. | CLD 23 | PUR | |
Series 1220 Tnemec Epoxy[2] [5] | >= 200 gal. | CLD 23 | EPOXY | |
Series 21 Epoxoline[2] [7] | >= 1,500 gal. | CLD 23 | EPOXY | |
Series 215[2] [24] | >= 200 gal. | CLD 23 | EPOXY | |
Series 215ML[2] [24] | >= 200 gal. | CLD 23 | EPOXY | |
Series 91-H2O ™ Hydro-Zinc™ [2] [8] [10] | >= 40,000 gal. | CLD 23 | PUR | |
Series 91-H2O™ Hydro-Zinc™[2] [8] [9] | >= 50,000 gal. | CLD 23 | PUR | |
Series 93-H20 Hydro-Zinc [11] | >= 50,000 gal | CLD 23 | PUR | |
Series 94-H2O Hydro Zinc[2] [12] | [25] | CLD 23 | PUR | |
Series FC22 Epoxoline[2] [26] | >= 200 gal. | CLD 23 | EPOXY | |
Series L140 Pota-Pox Plus[2] [15] | >= 50,000 gal. | CLD 23 | EPOXY | |
Series L140F Pota-Pox Plus Fast Cure[2] [16] | >= 50,000 gal. | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus[2] [17] | >= 4,000 gal. | CLD 23 | EPOXY | |
[1] Colors: 1255 Beige, 1218 Blue, WH11 White Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 50 Maximum Thinner: 5% Thinner #2 Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 5 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass flake S211-0220. The fiberglass flake can be added up to a rate of 1% by weight after the Parts A and B are mixed together. Certified for use as a primer or topcoat with any NSF Certified Tnemec coating system provided that both primer and topcoat meet their individual certified end uses. [2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes, toluene, and ethylbenzene. [3] Colors: Greenish Gray Number of Coats: 1 Maximum Field Use Dry Thickness (in mils): 4mils Maximum Thinner: 25% Water Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Series 44-780 Accelerator may be added up to 1 fl. oz/gal. Series 98-H2O Hydro-Zinc is approved for use as a primer with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Cure for Series 98-H2O Hydro-Zinc primer is 5 hours at 75F. Top-coat is then applied. Final cure is 7 days. Mix ratio of Part A:B:C is 1.4:0.6:1 by volume. [4] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592 RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Sequence of Coats: 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F (entire system) Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [5] Colors: White Number of Coats: 1-3 Maximum Field Use Dry Thickness (in mils): 18 mils Maximum Thinner: 15% water Recoat Cure Time and Temperature: 6 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Series 44-700 Accelerator may be added up to 1 fl. oz./gal. Series 1220 Tnemec Epoxy is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 2:1 by volume. [7] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 1-3 Maximum Field Use Dry Thickness(in mils): 20 Maximum Thinner: 5% F041-0088 Thinner Clear by volume Recoat Cure Time and Temperature: 8 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [8] Colors: Greenish-gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 10% Thinner No. 2 or 10% Thinner No. 3 by volume Final Cure Time and Temperature: 4 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. Series 91-H2O™ Hydro-Zinc™ is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 70%:30% by volume. [9] This coating used with Thinner #2 is Certified for use in pipes >=96", tanks >=50,000 gallons, fittings >=1", pumps >=1", and valves >=4". [10] This coatings used with Thinner #3 is Certified for use in pipes >=96", tanks >=40,000 gallons, fittings >=1", pumps >=1/2", and valves >=1.75". [11] Colors: Greenish-Gray Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% Thinner #2 by volume Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20 Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [12] Color: Greenish-Gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 15% Tnemec No. 49 by volume or 10% Thinner No. 3 or 10% Thinner No. 2 Recoat Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 may be added up to 4 fl. oz/gal. 94-H2O is approved for use with any NSF Certified Tnemec topcoat or coating system. [15] Colors: 00WH White, 1211 Red, 1255 Beige, 15BL Tank White Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 (maximum of 6 mils per coat) Maximum Thinner: 5% Tnemec No. 49 Thinner by volume Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be substituted as a primer or topcoat for L140 provided that both primer and topcoat meet their individual Certified end uses. Series 44-700 accelerator (Part C) may be added up to 4 fluid ounces per two mixed gallons of L140 Parts A and B. Mix ratio of A:B is 1:1 by volume. [16] Colors: 1255 Beige, 15BL Tank White, 1211 Red, 00WH White Number of Coats: 2-3 Sequence of coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 (maximum of 6 mils per coat) Maximum Thinner: 5% Tnemec No. 49 by volume Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F Special Comments: Series N140, N140F, V140, V140F, L140 and Series 22, FC22 may be substituted as a primer or topcoat for L140F provided that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A to Part B is 1:1 by volume. [17] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F (entire system) Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per gallon of Part A. [20] Colors: 1216 Greenish-Gray Number of Coats: 1 Sequence of Coats: N/A Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 10% Thinner No. 2 Recoat Cure Time and Temperature: 8 hours at 75°F Special Comment: Series 44-710 may be added up to 4 fl. oz/gal. Approved for use as a primer with any NSF Certified Tnemec topcoat or coating system provided that both primer and topcoat meet their individual Certified end uses. [24] Colors: 1200 White, 1212 Gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): Coating only: 80; With fiberglass mat: 95 Final Cure Time and Temperature: 7 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass mat S211-0215, S211-0216, and/or addition of fumed silica S211-0211 to coating. Mix ratio for fumed silica is 0.75:1 by volume. Approved for use with any NSF Certified Tnemec topcoat or coating system provided that both primer and topcoat meet their individual Certified end uses. [25] This coating used with Thinner #49 is Certified for use in tanks >= 1,500 gallons. This coating used with Thinner #2 is Certified for use in tanks >= 50,000 gallons. This coating used with Thinner #3 is Certified for use in tanks >= 40,000 gallons. [26] Colors: WH08 White, 35GR Epoxoline Black, R4875A Akzo Red, B8869A Epoxoline Blue Number of Coats: 1 Sequence of Coats: N/A Maximum Field Use Dry Film Thickness (in mils): 80 Maximum Thinner: None Final Cure Time and Temperature: 24 hours at 75° F Special Comments: Mix ratio of part A:Part B is 1:2 by volume. Any Listed color of Series F020, FC20, L140, L140F, N140, N140F, V140, or V140F may be used as a topcoat or primer for SeriesFC22 Epoxoline. |
||||
Coatings - Valve |
||||
22 Epoxoline[1] [2] | >= 4" | CLD 23 | EPOXY | |
F098-0H20 Hydro-Zinc[2] [3] | >= 4" | CLD 23 | EPOXY | |
N140F Pota-Pox Plus Fast Cure[2] [4] | >= 4" | CLD 23 | EPOXY | |
Series 1 Omnithane 1216 Greenish-Gray[2] [20] | >= 4" | CLD 23 | PUR | |
Series 1220 Tnemec Epoxy[2] [5] | >= 1 1/2" | CLD 23 | EPOXY | |
Series 21 Epoxoline[2] [7] | >= 4" | CLD 23 | EPOXY | |
Series 21 Epoxoline [2] [6] | >= 1/2" | CLD 23 | EPOXY | |
Series 91-H2O ™ Hydro-Zinc™[2] [8] [10] | >= 1 3/4" | CLD 23 | EPOXY | |
Series 91-H2O™ Hydro-Zinc™[2] [8] [9] | >= 4" | CLD 23 | PUR | |
Series 93-H20 Hydro-Zinc[11] | >= 4" | CLD 23 | PUR | |
Series 94-H2O Hydro-Zinc[2] [12] | [27] | CLD 23 | PUR | |
Series FC22 Epoxoline[2] [14] | >= 2" | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus[18] [22] | >= 4" | CLD 23 | EPOXY | |
Series N140 Pota-Pox Plus [2] [17] | >= 4" | CLD 23 | EPOXY | |
Series N140F Pota-Pox Plus Fast Cure[18] [19] | >= 4" | CLD 23 | EPOXY | |
[1] Colors: 1255 Beige, 1218 Blue, WH11 White Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 50 Maximum Thinner: 5% Thinner #2 Recoat Cure Time and Temperature: 16 hours at 75°F Final Cure Time and Temperature: 5 days at 75°F Special Comments: Mix ratio of Part A to Part B is 1:1 by volume. Optional use with fiberglass flake S211-0220. The fiberglass flake can be added up to a rate of 1% by weight after the Parts A and B are mixed together. Certified for use as a primer or topcoat with any NSF Certified Tnemec coating system provided that both primer and topcoat meet their individual certified end uses. [2] Meets the health effects requirements of NSF/ANSI/CAN 600 according to the requirements of NSF/ANSI/CAN 61 including the most current health effects criteria for xylenes, toluene, and ethylbenzene. [3] Colors: Greenish Gray Number of Coats: 1 Maximum Field Use Dry Thickness (in mils): 4mils Maximum Thinner: 25% Water Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Series 44-780 Accelerator may be added up to 1 fl. oz/gal. Series 98-H2O Hydro-Zinc is approved for use as a primer with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Cure for Series 98-H2O Hydro-Zinc primer is 5 hours at 75F. Top-coat is then applied. Final cure is 7 days. Mix ratio of Part A:B:C is 1.4:0.6:1 by volume. [4] Colors: 15BL Tank White, 1255 Beige, 1211 Red, 35GR Black, 39BL Delft Blue, Y2606 Romac Yellow, 00WH Tnemec White, 11SF True Blue, B9118 Baker Blue, B5712 Westech Blue, B2592 RAL 5009 Azurblau, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Sequence of Coats: 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75F Final Cure Time/Temperature: 7 days at 75F (entire system) Special Comments: Mix ration is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate topcoat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. [5] Colors: White Number of Coats: 1-3 Maximum Field Use Dry Thickness (in mils): 18 mils Maximum Thinner: 15% water Recoat Cure Time and Temperature: 6 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Series 44-700 Accelerator may be added up to 1 fl. oz./gal. Series 1220 Tnemec Epoxy is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 2:1 by volume. [6] Colors: WH16 Off-White, 1255 Beige, 39BL Delft Blue, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 2 Maximum Field Use Dry Thickness(in mils): 20 mils Maximum Thinner: None Recoat Cure Time and Temperature: 16 hours at 75F Final Cure Time/Temperature: 30 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. This is for pipe, fitting, pump and valve end use. [7] Colors: WH16 OFF-WHITE, 35GR Black, 33GR Gray, 39BL Delft Blue, 1255 Beige, B5712 Westech Blue, 11SF True Blue/Safety, 1211 Red Primer, A13096 Baker Dark Gray, B2592 RAL5009 Azurblau, B2506 Dezurik Blue, B9918 New Baker Blue Number of Coats: 1-3 Maximum Field Use Dry Thickness(in mils): 20 Maximum Thinner: 5% F041-0088 Thinner Clear by volume Recoat Cure Time and Temperature: 8 hours at 75F Final Cure Time/Temperature: 7 days at 75F Special Comments: Mix ratio of A:B is 2:1 by volume. Series 21 Epoxoline is approved for use as a primer or topcoat with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [8] Colors: Greenish-gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 10% Thinner No. 2 or 10% Thinner No. 3 by volume Final Cure Time and Temperature: 4 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 Urethane Accelerator may be added up to 4 fl. oz/gal. Series 91-H2O™ Hydro-Zinc™ is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. Mix ratio of Part A:Part B is 70%:30% by volume. [9] This coating used with Thinner #2 is Certified for use in pipes >=96", tanks >=50,000 gallons, fittings >=1", pumps >=1", and valves >=4". [10] This coatings used with Thinner #3 is Certified for use in pipes >=96", tanks >=40,000 gallons, fittings >=1", pumps >=1/2", and valves >=1.75". [11] Colors: Greenish-Gray Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% Thinner #2 by volume Final Cure Time/Temperature: 8 hours at 75F. 4 hours at 75F if accelerator is used. Special Comments: Series 44-710 accelerator may be used up to 4 fluid oz/gal. 93-H20 Hydro-Zinc is approved for use with any NSF Certified Tnemec topcoat or coating system providing that both primer and topcoat meet their individual Certified end uses. [12] Color: Greenish-Gray Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 15% Tnemec No. 49 by volume or 10% Thinner No. 3 or 10% Thinner No. 2 Recoat Cure Time and Temperature: 8 hours at 75°F; 2 hours at 75°F when the accelerator is used Special Comments: Series 44-710 may be added up to 4 fl. oz/gal. 94-H2O is approved for use with any NSF Certified Tnemec topcoat or coating system. [14] Colors: WH08 White, R4875A Akzo Red, B8869A Epoxoline Blue Number of Coats: 1 Sequence of Coats: N/A Maximum Field Use Dry Film Thickness (in mils): 80 Maximum Thinner: None Final Cure Time and Temperature: 24 hours at 75°F Special Comments: Mix ratio of Part A:Part B is 1:2 by volume. Any Listed color of series N140 or N140F may be used as a topcoat or primer for Series FC22 Epoxoline. [17] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank white, 35GR Black, 39BL Delft blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 1 Maximum Field Use Dry Thickness(in mils): 4 mils Maximum Thinner: 10% No. 4 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 7 days at 75°F (entire system) Special Comments: Mix ratio is 1 Part A to 1 Part B by volume. Certified for use as an optional primer or intermediate coat with any Tnemec NSF certified primer and topcoat coating system provided the primer, intermediate, and topcoat meet their certified end uses. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per gallon of Part A. [18] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of NSF/ANSI/CAN 61 for pump, valve, and fitting end use. [19] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft Blue, B2506 DeZurik Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B7896 S-B Blue, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 30 days at 75°F Special comments: Any listed color of Series 22, FC22, N140 or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A:Part B is 1:1 by volume. [20] Colors: 1216 Greenish-Gray Number of Coats: 1 Sequence of Coats: N/A Maximum Field Use Dry Film Thickness (in mils): 4 Maximum Thinner: 10% Thinner No. 2 Recoat Cure Time and Temperature: 8 hours at 75°F Special Comment: Series 44-710 may be added up to 4 fl. oz/gal. Approved for use as a primer with any NSF Certified Tnemec topcoat or coating system provided that both primer and topcoat meet their individual Certified end uses. [22] Colors: 00WH Tnemec White, 1211 Red, 1255 Beige, 15BL Tank White, 35GR Black, 39BL Delft Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, B8314 Krausz Blue, A13096 Baker Dark Gray, Y2606 Romac Yellow, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F without accelerator Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any Listed color of Series 22, FC22, N140, or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A:Part B is 1:1 by volume. Part C (Series 44-700 Accelerator) is an optional addititve to Part A in the field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B. [27] This coating used with Thinner #49 is Certified for use in valves >= ¾”. This coating used with Thinner #2 is Certified for use in valves >= 4”. This coating used with Thinner #3 is Certified for use in valves >= 1.75”. |
Facility : Jinshan District, Shanghai, China
Protective (Barrier) Materials
Water | Water | |||
Water Contact | Contact | Contact | ||
Trade Designation | Size Restriction | Temp | Material | |
Coatings - Fittings[1] |
||||
Series N140 Pota-Pox Plus[2] | >= 8" | CLD 23 | EPOXY | |
Series N140F Pota-Pox Plus Fast Cure[3] | >= 8" | CLD 23 | EPOXY | |
[1] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of NSF/ANSI/CAN 61 for pump, valve, and fitting end use. [2] Colors: 1211 Red, 1255 Beige,15BL Tank White, 39BL Delft Blue, 35GR Black, 00WH Tnemec White, Y2606 Romac Yellow, B8314 Krausz Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, A13096 Baker Dark Gray, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F without accelerator Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1 by volume. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B. [3] Colors: 1211 Red, 1255 Beige, B2506 DeZurik Blue, 15BL Tank White, 39BL Delft Blue, 35GR Black, 00WH Tnemec White, B7896 S-B Blue, Y2606 Romac Yellow, B5712 Blue, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1 by volume. |
||||
Coatings - Mechanical Devices[1] |
||||
Series N140 Pota-Pox Plus [2] | [4] | CLD 23 | EPOXY | |
[1] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of NSF/ANSI/CAN 61 for pump, valve, and fitting end use. [2] Colors: 1211 Red, 1255 Beige,15BL Tank White, 39BL Delft Blue, 35GR Black, 00WH Tnemec White, Y2606 Romac Yellow, B8314 Krausz Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, A13096 Baker Dark Gray, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F without accelerator Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1 by volume. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B. [4] Certified for mechanical device end use (other than pump and valve) for a maximum of 4.6 sq. ft. per gpm. |
||||
Coatings - Pump[1] |
||||
Series N140 Pota-Pox Plus[2] | >= 4" | CLD 23 | EPOXY | |
Series N140F Pota-Pox Plus Fast Cure[3] | >= 4" | CLD 23 | EPOXY | |
[1] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of NSF/ANSI/CAN 61 for pump, valve, and fitting end use. [2] Colors: 1211 Red, 1255 Beige,15BL Tank White, 39BL Delft Blue, 35GR Black, 00WH Tnemec White, Y2606 Romac Yellow, B8314 Krausz Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, A13096 Baker Dark Gray, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F without accelerator Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1 by volume. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B. [3] Colors: 1211 Red, 1255 Beige, B2506 DeZurik Blue, 15BL Tank White, 39BL Delft Blue, 35GR Black, 00WH Tnemec White, B7896 S-B Blue, Y2606 Romac Yellow, B5712 Blue, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1 by volume. |
||||
Coatings - Valve[1] |
||||
Series N140 Pota-Pox Plus[2] | >= 4" | CLD 23 | EPOXY | |
Series N140F Pota-Pox Plus Fast Cure[3] | >= 4" | CLD 23 | EPOXY | |
[1] Meets the health effects requirements of NSF/ANSI/CAN 600 according to requirements of NSF/ANSI/CAN 61 for pump, valve, and fitting end use. [2] Colors: 1211 Red, 1255 Beige,15BL Tank White, 39BL Delft Blue, 35GR Black, 00WH Tnemec White, Y2606 Romac Yellow, B8314 Krausz Blue, B5712 Westech Blue, 11SF True Blue, B9118 Baker Blue, A13096 Baker Dark Gray, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B2506 Dezurik Blue, A14130 Mueller Gray, B9695 Houston Blue, R5477 Mueller Sienna Red. Number of Coats: 2-3 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry Film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F with accelerator, 9 hours at 75°F without accelerator Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1 by volume. Part C (Series 44-700 Accelerator) is an optional additive to Part A in the field and may be added at up to 4 fluid ounces per two mixed gallons of parts A and B. [3] Colors: 1211 Red, 1255 Beige, B2506 DeZurik Blue, 15BL Tank White, 39BL Delft Blue, 35GR Black, 00WH Tnemec White, B7896 S-B Blue, Y2606 Romac Yellow, B5712 Blue, B2592 RAL 5009 Azurblau, B7011 Crispin Blue, B9695 Houston Blue, A14130 Mueller Gray, R5477 Mueller Sienna Red. Number of Coats: 2 Sequence of Coats: Any combination of Listed colors Maximum Field Use Dry film Thickness (in mils): 18 Maximum Thinner: 5% Tnemec No. 60 Thinner by volume Recoat Cure Time and Temperature: 5 hours at 75°F Final Cure Time and Temperature: 30 days at 75°F Special Comments: Any listed color of Series 22, FC22, N140, or 141 may be substituted as a primer of topcoat for Series N140 Pota-Pox Plus provided that both primer and topcoat meet their individual Certified end uses. The mix ratio of Part A: Part B is 1:1 by volume. |
Number of matching Manufacturers is 1
Number of matching Products is 141