NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, May 16, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=51220&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
Xypex Chemical Corporation 
13731 Mayfield Place
Richmond, BC V6V 2G9 
Canada 
604-273-5265


Facility : Richmond, British Columbia, Canada

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Patching Materials
Xypex Patch'n Plug[1] [2] CLD 23 CMNT

[1] Mix ratio is 1 part water to 3-3.5 parts Patch'n Plug by volume, mixed to the
    consistency of a stiff putty or workable mortar.  Certified for a 24 hour cure time at
    ambient temperature.
[2] Certified for use as a patching material for up to 5% of the surface area in pipes 8"
    and greater and tanks 1000 gallons and greater.


Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Tank[1]
HD-150[2] >= 100,000 gal. CLD 23 CMNT
Megamix I / Xycrylic Admix[3] >= 5,000 gal. CLD 23 CMNT
Xypex Concentrate[4] >= 12,000 gal. CLD 23 CMNT
Xypex Concentrate/Modified Coating System[2] >= 100,000 gal. CLD 23 CMNT
Xypex Megamix II[5] >= 1000 gal. CLD 23 CMNT

[1] Only products bearing the NSF Mark are Certified.
[2] Number of Coats: 2
    Sequence of Coats: 1 coat Concentrate, 1 coat Modified
    Recoat Cure Time and Temperature: 2 hours at 23ºC
    Final Cure Time and Temperature: 3 days moist cure followed by 12 days set time prior to
    water contact
    Special Comments: Mix ratio of powder:water is 5:2 by volume. Maximum film thickness is
    1/16 in (1.25mm).
[3] Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 126 (3.2 mm)
    Maximum Thinner: None
    Final Cure Time and Temperature: 3 days at 20°C
    Special Comments: Combine 1 part Xycrylic Admix with 2 parts water. Then, mix 0.23
    gallons of the liquid mixture with 10 lbs. of dry Megamix I Powder. Certified for
    Megamix I and Xycrylic-Admix as a system mixed and applied as described. Neither
    component is Certified on its own.
[4] Number of Coats: 2
    Recoat Cure Time and Temperature: 2 hours at 23ºC
    Final Cure Time and Temperature: 3 days moist cure followed by 12 days set time prior to
    water contact
    Special Comments: Mix ratio of powder:water is 5:2 by volume. Maximum film thickness is
    1/16 in (1.25mm).
[5] Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 500 - 2000
    Final Cure Time and Temperature: 3 days moist cure at 72°F
    Special Comments: Mix ratio of water:powder is 0.9 gallons:55 lbs or 1 gallon:60 lbs.

Concrete Admixtures[1]
Admix C-1000[6] >= 10,000 gal. C. HOT CMNT
Admix C-2000[6] >= 10,000 gal. C. HOT CMNT
Admix C-500[6] >= 10,000 gal. C. HOT CMNT

[1] Only products bearing the NSF Mark are Certified.
[6] Certified for Regular Mix Grade at a level not to exceed 2% by weight of cement and No
    Fines Grade at a level not to exceed 1% by weight of cement.


Number of matching Manufacturers is 1