NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, November 21, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0048917&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
H.B. Fuller Company | |
1200 Willow Lake Boulevard | |
St. Paul, MN 55110-5101 | |
United States | |
651-236-5900 | |
Visit this company's website |
Facility : Grand Rapids, MI
Joining and Sealing Materials
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Adhesives |
||||
H.B. Fuller® UR-3501-A and H.B. Fuller® UR-3501-B[1] | [3] | D. HOT | ADH | |
H.B. Fuller® UR-3577-A and H.B. Fuller® UR-3577-B[2] [G] | [3] | D. HOT | ADH | |
H.B. Fuller® UR-3577-ALV and H.B. Fuller® UR-3577-B[2] [G] | [3] | D. HOT | ADH | |
H.B. Fuller® UR-3577-MA and H.B. Fuller® UR-3577-MB[2] [G] | [3] | D. HOT | ADH | |
H.B. Fuller® UR-3579-A and H.B. Fuller® UR-3579-B[2] [G] | [3] | D. HOT | ADH | |
[1] Mix ratio is 100:50 (A:B) by volume or 100:62.5 (A:B) by weight. Minimum cure time is 7 days at 77°F then 3 hours at 158°F. [2] Mix ratio is 100:100 (A:B) by volume or 100:110 (A:B) by weight with a maximum dry film thickness of 50 mils. Minimum cure time is 7 days at 77°F then 3 hours at 158°F [3] Certified for a maximum surface area to volume ratio of 7.26 sq. in/L. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Potting Compounds |
||||
H.B. Fuller® UR-2187-A and H.B. Fuller® UR-2187-B | [1] | CLD 23 | PUR | |
[1] Certified for use as a potting material in hollow fiber filtration devices 8 inches in diameter and larger with a minimum daily flow of 2000 Liters. |
Facility : Jiangsu Province, China
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Adhesives |
||||
UR3519 A and UR3519 B[1] | [2] | D. HOT | PUR | |
UR3519 A(I) and UR3519 B(I)[1] | [2] | D. HOT | PUR | |
UR3519LV A and UR3519LV B[1] | [2] | D. HOT | PUR | |
UR3528 A and UR3528 B[1] | [2] | D. HOT | PUR | |
UR3539 A and UR3539 B[3] | [2] | D. HOT | PUR | |
UR3559 A and UR3559 B[1] | [2] | D. HOT | PUR | |
[1] Mix ratio: By weight: 0.9 Part A:1.0 Part B By volume: 100 Part A:100 Part B Product cure: Minimum cure time is 7 days at 77°F. [2] Certified for a maximum surface area to volume ratio of 20 sq. in./L in spiral-wound filter elements with a minimum daily flow of 12,000 liters per day. [3] Mix ratio: By weight: 1.0 Part A: 1.1 Part B By volume: 1 Part A: 1 Part B Product cure: Minimum cure time is 7 days at 77°F. |
Number of matching Manufacturers is 1
Number of matching Products is 12