NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| GC Valves, LLC | |
| 456 Crompton Street | |
| Charlotte, NC 28273 | |
| United States | |
| 800-828-0484 | |
| 805-582-0065 | |
| Visit this company's website |
Facility : Charlotte, NC
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Solenoid Valves [G] |
||||
| NC4 C H CC V SL B P O OP[1] | 1/8" - 1/4" | CLD 23 | MLTPL | |
| NC5 C H CC V SL B P O OP[1] | 1/8" | CLD 23 | MLTPL | |
| NP4 C H CC V SL B P O OP[2] | 1/4 - 2" | CLD 23 | MLTPL | |
| NP5 C H CC V SL B P O OP[2] | 3/8" - 2" | CLD 23 | MLTPL | |
| NS71 (C)(H)(CC)(V)(SL)(B)(P)(O)(OP)[3] | 3/8" - 2" | C. HOT | MLTPL | |
[1] NC Series Direct Acting Valves
(C) Configuration/function
1 - 2-way normally closed
2 - 2-way normally open
3 - 3-way normally closed
4 - 3-way normally open
(H) Housing
G - Encapsulated housing, wire leads
Y - Encapsulated housing, 43650B DIN connection
(CC) Coil Class
N - 200
(V) Voltage, any value
(SL) Seals
C - EPDM
(B) Body
D - Stainless steel body and operator
G -Polyamide and stainless steel operator
(P) Pipe size
A - 1/8 NPT
B - 1/4 NPT
(O) Orifice size
A0 - 0.8mm
A1 - 1.0mm
A2 - 1.2mm
A3 - 1.6mm
A4 - 2.0mm
A5 - 2.4mm
A6 - 3.0mm
A7 - 4.0mm
A8 - 4.5mm
06 - 6.0mm
08 - 8.0mm
(OP) Options
E - Applicable Canadian Ratings
C - CE Certification
M - Manual Override
A - Angled Body
[2] NP Series Piloted valves
(C) Configuration/function
1 - 2-way normally closed
2 - 2-way normally open
(H) Housing
G - Encapsulated housing, wire leads
Y - Encapsulated housing, 43650B DIN connection
(CC) Coil Class
N - 200
(V) Voltage, any value
(SL) Seals
C - EPDM
(B) Body
G - Polyamide and Stainless steel operator
L - Stainless steel body and operator
Z - Stainless steel body and operator
(P) Pipe size:
B - 1/4 in NPT
C - 3/8 in NPT
D - 1/2 in NPT
E - 3/4 in NPT
F - 1 in NPT
H - 1 1/2 in NPT
I - 2 in NPT
(O) Orifice size
08 - 0.8mm
12 - 12.0mm
20 - 20.0mm
25 - 25.0mm
27 - 27.0mm
55 - 55.0mm
(OP) Options
E - Applicable Canadian Ratings
C - CE Certification
M - Manual Override
[3] NS71 Series
(C) Configuration
1 - Normally Closed
2 - Normally Open
(H) Housing
A - Metal Housing, 1/2" Conduit, Wire Leads
B - Metal Housing, Grommet, Wire Leads
G - Encapsulated Housing, 1/2" Conduit, Wire Leads
P - Plated Steel Open Frame, Wire Leads
R - Plated Steel Open Frame, Quick Connect
S - Metal Housing, Junction Box, Wire Leads
U - Metal Housing, Side Junction Box, Wire Leads
W - Metal Housing, Rain Tight, NEMA 3, Wire Leads
Y - Encapsulated Housing, 43650 Din Connection
(CC) Coil Class -
F - Coil Class 155
H - Coil Class 180
N - Coil Class 200
(V) Voltage -
01 - 24 V, 60Hz
02 - 120 V, 60Hz & 110 V, 50Hz
03 - 208 V, 60Hz
04 - 240 V, 60Hz & 220 V, 50Hz
05 - 120/240 V, 60Hz & 110/220 V, 50Hz
07 - 480 V, 60Hz & 440 V, 50Hz
13 - 550 V, 60Hz & 500 V, 50Hz
14 - 6 V dc
15 - 12 V dc
16 - 24 V dc
17 - 32 V dc
18 - 120 V dc
19 - 240 V dc
25 - 100 V dc
30 - 480 V dc
33 - 48 V dc
37 - 64 V dc
54 - 240 V, 50 Hz
55 - 380 V, 50 Hz
66 - 12 V, 60Hz
74 - 74 V dc
88 - 100 V, 50/60 Hz
94 - 200 V, 50/60 Hz
(SL) Seals
C - EPDM
(B) Body
9 - Lead Free Brass
(P) Pipe Size
C - 3/8”
D - 1/2"
E - 3/4"
F - 1"
G - 1 1/4"
H - 1 1/2"
J - 2"
(O) Orifice
F5 3/8"
G1 - 1/2"
G4 5/8"
G5 3/4"
G9 1"
J2 1 1/4"
J5 - 1 1/2"
J7 - 2”
(OP) Options
E - Applicable Canadian Ratings
C - CE Certification
K - Mounting bracket
M - Manual override
T - Time saver quick connect
T1 - Time saver quick connect
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Valves [G] |
||||
| (S)(C)(H)(CC)(V)(SL)(B)(P)(O)(OP)[4] | 1/8" - 2" | C. HOT | MLTPL | |
| (S)(C)(H)(CC)(V)(SL)(B)(P)(O)(OP) [5] | 3/8" - 1" | C. HOT | MLTPL | |
| (S)(C)(H)(CC)(V)(SL)(B)(P)(OP)[6] | 3/8" - 1" | CLD 23 | MLTPL | |
[4] (S) Series
NS20 - Zero differential diaphragm valve
NS21 - Diaphragm valve
NS30 - zero differential direct acting valve
NS31 - zero differential direct acting valve
(C) Configuration
1 - Normally closed
2 - Normally open
(H) Housing
A - Metal housing, 1/2" conduit, wire leads
B - Metal housing, grommet, wire leads
G - Encapsulated housing, 1/2" conduit, wire leads
N - Stainless steel open frame, wire leads
P - Plated steel open frame, wire leads
R - Plated steel open frame, quick connect
S - Metal housing, junction box, wire leads
U - Metal housing, side junction box, wire leads
W - Metal housing, rain tight, NEMA 3, wire leads
Y - Encapsulated housing, 43650 din connection
(CC) Coil class
F - Coil class 155 (F)
H - Coil class 180 (H)
N - Coil class 200 (N)
(V) Voltage, any value
(SL) Seals
F - EPDM/santoprene seals
C - EPDM
(B) Body
7 - SS 316 stainless steel body
2 - 303 stainless steel body
3 - 303 stainless steel body
(P) Pipe size
A - 1/8"
B - 1/4"
C - 3/8"
D - 1/2"
E - 3/4"
F - 1"
G - 1 1/4"
H - 1 1/2"
J - 2"
(O) Orifice
G4 - 5/8"
G5 - 3/4"
G9 - 1"
C1 - 1/32"
C3 - 3/64"
C5 - 1/16"
C7 - 5/64"
C9 - 3/32"
D5 - 1/8"
D7 - 5/32"
E1 - 3/16"
E7 - 1/4"
F1 - 9/32"
F5 - 3/8"
J2 - 1 1/4"
(OP) Options
E - Applicable Canadian Ratings
C - CE Certification
K - Mounting bracket
M - Manual override
[5] (S) Series
NP31 - Diaphragm Valve
NS20 - Zero Differential Diaphragm Valve
NS21 - Diaphragm Valve
(C) Configuration
1 - Normally Closed
2 - Normally Open
(H) Housing
A - Metal Housing, 1/2" Conduit, Wire Leads
B - Metal Housing, Grommet, Wire Leads
G - Encapsulated Housing, 1/2" Conduit, Wire Leads
N - Stainless Steel Open Frame, Wire Leads
P - Plated Steel Open Frame, Wire Leads
R - Plated Steel Open Frame, Quick Connect
S - Metal Housing, Junction Box, Wire Leads
U - Metal Housing, Side Junction Box, Wire Leads
W - Metal Housing, Rain Tight, NEMA 3, Wire Leads
Y - Encapsulated Housing, 43650 Din Connection
(CC) Coil Class
F - Coil Class 155 (F)
H - Coil Class 180 (H)
N - Coil Class 200 (N)
(V) Voltage
Any value
(SL) Seals
F - EPDM/Santoprene Seals
C - EPDM
(B) Body
P - Durethan BKV 130 CS 600091 or Ultramid B3EG6
(P) Pipe Size
C - 3/8"
D - 1/2"
E - 3/4"
F - 1"
(O) Orifice
C1 - 1/32"
C3 - 3/64"
C5 - 1/16"
C7 - 5/64"
C9 - 3/32"
D5 - 1/8"
D7 - 5/32"
E1 - 3/16"
E7 - 1/4"
F1 - 9/32"
F5 - 3/8"
G4 - 5/8"
G5 - 3/4"
G9 - 1"
J2 - 1 1/4"
(OP) Options
C - CE Certification
E - Applicable Canadian Ratings
K - Mounting Bracket
M - Manual Override
T - Time saver quick connect - IN and OUT ports (Durethan BKV 130 CS, Ultramid
B3EG6)
T1 - Time saver quick connect - IN port only (Durethan BKV 130 CS, Ultramid
B3EG6)
[6] (S) Series
NTP3 - Diaphragm Valve - True Union Connections, 3/8" - 3/4"
NT20 - Zero Differential Diaphragm Valve - True Union Connections, 3/8" - 1"
NT21 - Diaphragm Valve - True Union Connections, 3/8" - 3/4"
(C) Configuration
1 - Normally Closed
2 - Normally Open
(H) Housing
A - Metal Housing, 1/2" Conduit, Wire Leads
B - Metal Housing, Grommet, Wire Leads
G - Encapsulated Housing, 1/2" Conduit, Wire Leads
P - Plated Steel Open Frame, Wire Leads
R - Plated Steel Open Frame, Quick Connect
S - Metal Housing, Junction Box, Wire Leads
U - Metal Housing, Side Junction Box, Wire Leads
W - Metal Housing, Rain Tight, NEMA 3, Wire Leads
Y - Encapsulated Housing, 43650 Din Connection
(CC) Coil class
F - Coil Class 155
H - Coil Class 180
N - Coil Class 200
(V) Voltage
01 - 24 V, 60Hz
02 - 120 V, 60Hz & 110 V, 50Hz
03 - 208 V, 60Hz
04 - 240 V, 60Hz & 220 V, 50Hz
05 - 120/240 V, 60Hz & 110/220 V, 50Hz
07 - 480 V, 60Hz & 440 V, 50Hz
13 - 550 V, 60Hz & 500 V, 50Hz
14 - 6 V dc
15 - 12 V dc
16 - 24 V dc
17 - 32 V dc
18 - 120 V dc
19 - 240 V dc
24 - 24V, 50/60 Hz
25 - 100 V dc
30 - 480 V dc
33 - 48 V dc
37 - 64 V dc
45 - 12 V dc
46 - 24 V dc
54 - 240 V, 50 Hz
55 - 380 V, 50 Hz
66 - 12 V, 60Hz
74 - 74 V dc
88 - 100 V, 50/60 Hz
94 - 200 V, 50/60 Hz
(SL) Seals
C - NSF EPDM
F - NSF EPDM/ Santoprene Seals
(B) Body
P - Ultramid B3EG6
(P) Pipe size
C - 3/8”
D - 1/2"
E - 3/4"
F - 1"
(OP) Options
E - Applicable Canadian Ratings
K - Mounting bracket
M - Manual override
P - Operator Nicklel Plating
0 - True Union Connections - Union Fittings not Included
1 - True Union Connections - One Union Fitting Included
2 - True Union Connections - Two Union Fittings Included
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 8
Processing time was 1 seconds