NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, January 20, 2022 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0286352&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings.


 
Insituform Technologies, LLC. 
170 Corporate Drive
Batesville, MS 38606 
United States 
662-561-7935
Visit this company's website


Facility : Batesville, MS

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Pipe Liner - Immediate Return to Service
InsituMain[1] [2] >= 6" CLD 23 MLTPL
InsituMain UVA[2] [3] [4] >= 6" CLD 23 MLTPL

[1] Evaluted for Immediate Return to Service. Method #1 Using potable water as the source
    for cure water, the temperature of the cure water is raised from ambient temperature
    until the water reaches 180°F (82°C) and is held for 5 hours. The water is then allowed
    to cool down to below 100°F over a period of at least 1 hour. An additional ambient cure
    of 2 days is required prior to placing into service. Method #2 Using potable water as
    the source for steam, steam at a minimum temperature of 200°F is used to cure and is
    held for 2 hours. The tube/liner is then allowed to cool down to below 110°F over a
    period of at least 30 minutes. An additional ambient cure of 2 days is required prior to
    placing into service.
[2] Certified for equivialent metric sizes.
[3] Evaluated for Immediate Return to Service.
[4] Product is cured when internal temperature reaches 160°F.

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Number of matching Manufacturers is 1
Number of matching Products is 2
Processing time was 0 seconds