NSF Product and Service Listings
These NSF Official Listings are current as of Friday, December 26, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0318248&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| WILO USA LLC | |
| 550 East South Street | |
| Collierville, TN 38017 | |
| United States | |
| 888-945-6872 | |
| 229-584-0097 | |
| Visit this company's website |
Facility : Izmir, Turkey
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Submersible Motors [G] |
||||
| YY 304SS XX HP, ZZ, 3PH 3S, HT[1] [2] [3] [4] | 6" - 10" | CLD 23 | MLTPL | |
[1] Certified for a minimum daily flow of 80,000 L.
[2] YY - Motor diameter
[3] XX - Motor power
[4] ZZ - Motor voltage
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Submersible Pump - Pump Ends [G] |
||||
| SPI WW XX YY ZZ M S[1] [5] [6] [7] [8] [9] [10] | 6" - 10" | CLD 23 | MLTPL | |
[1] Certified for a minimum daily flow of 80,000 L.
[5] WW - Nominal diameter
06 - 6"
07 - 7"
08 - 8"
10 - 10"
[6] XX - Nominal capacity
50 - 10 m3/hour
90 - 17 m3/hour
150 - 30 m3/hour
230 - 45 m3/hour
300 - 60 m3/hour
400 - 75 m3/hour
500 - 95 m3/hour
650 - 125 m3/hour
800 - 160 m3/hour
1200 - 210 m3/hour
[7] YY - Number of stages
1 - 60
[8] S - Pump suction size
[9] ZZ - Motor power
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
[10] M - Suction Case type
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 2
Processing time was 0 seconds