NSF Product and Service Listings
These NSF Official Listings are current as of Friday, December 26, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0319497&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| Radius Systems Ltd. | |
| Radius House, Berristow Lane | |
| South Normanton, Alfreton | |
| Derbyshire DE55 2JJ | |
| United Kingdom | |
| 44 177 381 1112 | |
| Visit this company's website |
Facility : Derbyshire, United Kingdom
Protective (Barrier) Materials
| Water | Water | |||
| Water Contact | Contact | Contact | ||
| Trade Designation | Size Restriction | Temp | Material | |
|
Coatings - Fittings[1] [2] [G] |
||||
| Subcote FLP II | >= 3" | CLD 23 | PUR | |
[1] Colors: Pale Sage Green
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 40-276
Maximum thinner: None
Final Cure Time and Temperature: 1 hour at 3°C
Special Comments: Mix ratio of Part A:B is 3:2 by volume or 100:72 by weight. 100%
solids. Product requires disinfection using 100mg/liter of free chlorine for periods up
to 30 minutes. After disinfection, the main shall be flushed with cold water for a
minimum period of 1 hour at a minimum flow velocity of 0.5 m.s-1.
[2] Product requires disinfection using a maximum of 100mg/liter of free chlorine for
periods up to 30 minutes maximum. After disinfection, the main shall be flushed with
cold water for a minimum period of 1 hour at a minimum flow velocity of 0.5 m.s-1.
Please reference manufacturer's product instructions for flushing recommendations for
additional product size ranges.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Coatings - Pipe - Immediate Return to Service[1] [2] [3] [G] |
||||
| Subcote FLP II | >= 3" | CLD 23 | PUR | |
[1] Colors: Pale Sage Green
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 40-276
Maximum thinner: None
Final Cure Time and Temperature: 1 hour at 3°C
Special Comments: Mix ratio of Part A:B is 3:2 by volume or 100:72 by weight. 100%
solids. Product requires disinfection using 100mg/liter of free chlorine for periods up
to 30 minutes. After disinfection, the main shall be flushed with cold water for a
minimum period of 1 hour at a minimum flow velocity of 0.5 m.s-1.
[2] Product requires disinfection using a maximum of 100mg/liter of free chlorine for
periods up to 30 minutes maximum. After disinfection, the main shall be flushed with
cold water for a minimum period of 1 hour at a minimum flow velocity of 0.5 m.s-1.
Please reference manufacturer's product instructions for flushing recommendations for
additional product size ranges.
[3] Evaluated for Immediate Return to Service.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Coatings - Tank[1] [2] [G] |
||||
| Subcote FLP II | >= 264 gal | CLD 23 | PUR | |
[1] Colors: Pale Sage Green
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 40-276
Maximum thinner: None
Final Cure Time and Temperature: 1 hour at 3°C
Special Comments: Mix ratio of Part A:B is 3:2 by volume or 100:72 by weight. 100%
solids. Product requires disinfection using 100mg/liter of free chlorine for periods up
to 30 minutes. After disinfection, the main shall be flushed with cold water for a
minimum period of 1 hour at a minimum flow velocity of 0.5 m.s-1.
[2] Product requires disinfection using a maximum of 100mg/liter of free chlorine for
periods up to 30 minutes maximum. After disinfection, the main shall be flushed with
cold water for a minimum period of 1 hour at a minimum flow velocity of 0.5 m.s-1.
Please reference manufacturer's product instructions for flushing recommendations for
additional product size ranges.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Coatings - Valve[1] [2] [G] |
||||
| Subcote FLP II | >= 3" | CLD 23 | PUR | |
[1] Colors: Pale Sage Green
Number of Coats: 1
Maximum Field Use Dry Film Thickness (in mils): 40-276
Maximum thinner: None
Final Cure Time and Temperature: 1 hour at 3°C
Special Comments: Mix ratio of Part A:B is 3:2 by volume or 100:72 by weight. 100%
solids. Product requires disinfection using 100mg/liter of free chlorine for periods up
to 30 minutes. After disinfection, the main shall be flushed with cold water for a
minimum period of 1 hour at a minimum flow velocity of 0.5 m.s-1.
[2] Product requires disinfection using a maximum of 100mg/liter of free chlorine for
periods up to 30 minutes maximum. After disinfection, the main shall be flushed with
cold water for a minimum period of 1 hour at a minimum flow velocity of 0.5 m.s-1.
Please reference manufacturer's product instructions for flushing recommendations for
additional product size ranges.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 4
Processing time was 0 seconds