NSF Product and Service Listings
These NSF Official Listings are current as of Monday, October 27, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0336196&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| Tank Connection | |
| 3609 North 16th Street | |
| Parsons, KS 67357 | |
| United States | |
| 620-423-3010 |
Facility : Orange City, IA
Protective (Barrier) Materials
| Water | Water | |||
| Water Contact | Contact | Contact | ||
| Trade Designation | Size Restriction | Temp | Material | |
|
Coatings - Pipe[1] [G] |
||||
| LIQ Fusion 8000 FBE Aqua White | >= 2.5" | CLD 23 | PEC | |
| LIQ Fusion 8000 FBE Light Gray | >= 2.5" | CLD 23 | PEC | |
[1] Colors: Gray, White
Number of coats: 1-2
Maximum field use dry film thickness (in mils): 20 mils
Recoat cure time and temperature: 15 minutes at 350°F
Final cure time and temperature: 15 minutes at 350°F
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Coatings - Tank[1] [G] |
||||
| LIQ Fusion 8000 FBE Aqua White | >= 4000 gal | CLD 23 | PEC | |
| LIQ Fusion 8000 FBE Light Gray | >= 4000 gal | CLD 23 | PEC | |
[1] Colors: Gray, White
Number of coats: 1-2
Maximum field use dry film thickness (in mils): 20 mils
Recoat cure time and temperature: 15 minutes at 350°F
Final cure time and temperature: 15 minutes at 350°F
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 4
Processing time was 0 seconds

