NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| Ceme SPA | |
| Via Dell'industria, 5 | |
| 27020 Trivolzio, PV | |
| Italy | |
| 39 0382 18051 | |
| Visit this company's website |
Facility : Zhongshan, China
Mechanical Plumbing Devices
| Trade Designation | ||||
|
Hot Water Dispenser Components[1] [2] [G] |
||||
| Series W[Q] | ||||
[Q] This product meets the reduced Q test statistic criteria of 1 ug or 0.5 ug for lead per
Section 9.5.1.1 of NSF/ANSI/CAN 61.
|
||||
[1] Valves are named as follows: W A B CDE F G H I WXX, where:
W - Series W Valve
A - Inlet
2 - MOULD BODY WITH 3/4" INLET, 3/4"(OUTPUT PUSHFIT)
A - MOULD WATER VALVE FITTINGS MALE 180°, G 3/4"
B - MOULD WATER VALVE FITTINGS MALE 180°, G 1/2"
C - MOULD WATER VALVE FITTINGS MALE 180°, G 3/8"
D - MOULD WATER VALVE FITTINGS MALE 180° CUSTOMIZE FOR KEURIG 180°, 3/4"
F - MOULD WATER VALVE FITTINGS MALE 90°, G 1/2"
G - MOULD WATER VALVE FITTINGS MALE 90°, G 3/4"
0 - ONLY PILOT, NO BODY
B - Outlet
2 - MOULD BODY WITH 3/4" INLET, JG6mm
3 - MOULD BODY WITH 3/4" INLET, JG10mm
4 - MOULD BODY WITH 3/4" INLET, JG8mm
7 - MOULD BODY WITH 3/4" INLET, JG1/4”
A - MOULD WATER VALVE FITTINGS MALE 180°, G 3/4"
B - MOULD WATER VALVE FITTINGS MALE 180°, G 1/2"
C - MOULD WATER VALVE FITTINGS MALE 180°, G 3/8"
F - MOULD WATER VALVE FITTINGS MALE 90°, G 1/2"
0 - ONLY PILOT, NO BODY
CDE - DN mm 00,0
100 - 10 mm
F - FLOW RESTRICTOR
0 - WITHOUT
1 - (1,2) liters
2 - (2,2) liters
G - FLOW REGULATOR
0 - WITHOUT
H - FILTER
0 - WITHOUT
1 - 80 mesh
2 - 150 mesh
3 - Check Valve
I - CUSTOMIZATION
0 - WITHOUT
1 - WITH (SPECIAL EXECUTION)
3 - NEEDLE
WXX - COIL
[2] Series W valves are solenoid valves intended for use with hot water dispensers up to 65
degrees Celsius.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Solenoid Valves[3] [G] |
||||
| V3 Series[Q] | ||||
| V7 Series[Q] | ||||
| VD Series[Q] | ||||
[Q] This product meets the reduced Q test statistic criteria of 1 ug or 0.5 ug for lead per
Section 9.5.1.1 of NSF/ANSI/CAN 61.
|
||||
[3] Valves are named as follows: VJ XX YY ZZZ P WWW KKKK
SERIES
V - Fixed
J - 3 for 3 way
7 for 2 way
D for Dump
VERSION
XX - Sequential number for hydraulic connections
(in V3 models) - 18, 19, 30, 33, 40, 53, 54, 55, 70, 73, 82, 83, 91, 92, 93, 95,
97, 99
(in V7 models) - 19, 30, 31, 39, 40, 42, 43, 44, 45, 70, 82, 91, 93, 95, 99
(in VD models) - 00, 03
KIND OF SEALING
YY - LS for LSR liquid silicone
VN for Silicone neutral
EN for EPDM black
SEAT DIAMETER - Two or three digits
ZZ or ZZZ - Internal fluid passage diameter
(in V3 models ) - 10, 12, 15, 20, 25, 26, 27
(in V7 models) - 10, 12, 15, 20, 25
(in VD models) - 100
BODY TREATMENT
P - Plastic body
SPECIAL EXECUTION - Not in contact with water
WWW - In case of NO special execution NO digit
STANDARD COIL - Not in contact with water
KKKK - It depends on type of coil.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
Facility : Cavenago di Brianza (MB), Italy
Mechanical Plumbing Devices
| Trade Designation | ||||
|
Solenoid Valves[3] [G] |
||||
| Series L Valves[Q] | ||||
[Q] This product meets the reduced Q test statistic criteria of 1 ug or 0.5 ug for lead per
Section 9.5.1.1 of NSF/ANSI/CAN 61.
|
||||
[3] L - Series L Valve
AAA - Version
400 - Body thread M20*1
500 - Body thread M22*2
BB - Seat Diameter
50 - 5 mm
CC - Kind of Seals
LS - LSR Liquid Silicone
P - Plastic Body
DD - Special Execution
EEE - Coil Type
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Hot Water Dispenser Components[1] [2] [G] |
||||
| Series W[Q] | ||||
[Q] This product meets the reduced Q test statistic criteria of 1 ug or 0.5 ug for lead per
Section 9.5.1.1 of NSF/ANSI/CAN 61.
|
||||
[1] Valves are named as follows: W A B CDE F G H I WXX, where:
W - Series W Valve
A - Inlet
2 - MOULD BODY WITH 3/4" INLET, 3/4"(OUTPUT PUSHFIT)
A - MOULD WATER VALVE FITTINGS MALE 180°, G ¾”
B - MOULD WATER VALVE FITTINGS MALE 180°, G ½”
C - MOULD WATER VALVE FITTINGS MALE 180°, G 3/8"
D - MOULD WATER VALVE FITTINGS MALE 180° CUSTOMIZE FOR KEURIG 180°, 3/4"
F - MOULD WATER VALVE FITTINGS MALE 90°, G ½”
G - MOULD WATER VALVE FITTINGS MALE 90°, G ¾”
L - MOULD WATER VALVE FITTINGS, Push fit Ø6mm
M - MOULD WATER VALVE FITTINGS, Push fit Ø8mm
N - MOULD WATER VALVE FITTINGS, Push fit Ø10mm
P - MOULD WATER VALVE FITTINGS, Push fit Ø1/4”
R - MOULD WATER VALVE FITTINGS, Push fit Ø3/8”
0 - ONLY PILOT, NO BODY
B - Outlet
2 - MOULD BODY WITH 3/4" INLET, JG6mm
3 - MOULD BODY WITH 3/4" INLET, JG10mm
4 - MOULD BODY WITH 3/4" INLET, JG8mm
7 - MOULD BODY WITH 3/4" INLET, JG1/4”
A - MOULD WATER VALVE FITTINGS MALE 180°, G 3/4"
B - MOULD WATER VALVE FITTINGS MALE 180°, G 1/2"
C - MOULD WATER VALVE FITTINGS MALE 180°, G 3/8"
F - MOULD WATER VALVE FITTINGS MALE 90°, G 1/2"
L - MOULD WATER VALVE FITTINGS, Push fit Ø6mm
M - MOULD WATER VALVE FITTINGS, Push fit Ø8mm
N - MOULD WATER VALVE FITTINGS, Push fit Ø10mm
P - MOULD WATER VALVE FITTINGS, Push fit Ø1/4”
R - MOULD WATER VALVE FITTINGS, Push fit Ø3/8”
0 - ONLY PILOT, NO BODY
CDE - DN mm 00,0
100 - 10 mm
F - FLOW RESTRICTOR
0 - WITHOUT
1 - (1,2) liters
2 - (2,2) liters
G - FLOW REGULATOR
0 - WITHOUT
H - FILTER
0 - WITHOUT
1 - 80 mesh
2 - 150 mesh
3 - Check Valve
I - CUSTOMIZATION
0 - WITHOUT
1 - WITH (SPECIAL EXECUTION
3 - NEEDLE
WXX - COIL
[2] Series W valves are solenoid valves intended for use with hot water dispensers up to 65
degrees Celsius.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
Facility : Inzago, Italy
Mechanical Plumbing Devices
| Trade Designation | ||||
|
Solenoid Valves[1] [G] |
||||
| V3 Series[Q] | ||||
| V7 Series[Q] | ||||
[Q] This product meets the reduced Q test statistic criteria of 1 ug or 0.5 ug for lead per
Section 9.5.1.1 of NSF/ANSI/CAN 61.
|
||||
[1] Valves are named as follows: VJ XX YY ZZZ P WWW KKKK
SERIES
V - Fixed
J - 3 for 3 way
7 for 2 way
VERSION
XX - Sequential number for hydraulic connections
(in V3 models) - 18, 19, 30, 40, 53, 54, 55, 70, 73, 82, 83, 91, 92, 93, 95, 97, 99
(in V7 models) - 19, 30, 31, 39, 40, 42, 43, 44, 45, 70, 82, 91, 93, 95, 99
KIND OF SEALING
YY - LS for LSR liquid silicone
VN for Silicone neutral
EN for EPDM black
SEAT DIAMETER - Two or three digits
ZZ or ZZZ - Internal fluid passage diameter
(in V3 models ) - 10, 12, 15, 20, 25, 26, 27
(in V7 models) - 10, 12, 15, 20, 25
BODY TREATMENT
P - Plastic body
SPECIAL EXECUTION - Not in contact with water
WWW - In case of NO special execution NO digit
STANDARD COIL - Not in contact with water
KKKK - It depends on type of coil.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 8
Processing time was 0 seconds