NSF Product and Service Listings

These NSF Official Listings are current as of Tuesday, January 25, 2022 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0498921&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings.


 
Honeywell International Inc. 
315 East Stephenson Street
Freeport, IL 61032 
United States 
815-618-6279


Facility : Chihuahua, Mexico

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Transmitters/Gauges[1] [G]
Media Isolate Pressure Sensor with 1/4" 45° Female Shrader Port 1/4" CLD 23 MLTPL
Media Isolate Pressure Sensor with 1/4-18 NPT Port 1/4" CLD 23 MLTPL
Media Isolate Pressure Sensor with 1/8-27 NPT Port 1/8" CLD 23 MLTPL
Media Isolate Pressure Sensor with G1/4 A Port 1/4" CLD 23 MLTPL
Media Isolate Pressure Sensor with M12 X 1.5 Port 12 mm CLD 23 MLTPL

[1] MIPS Pressure Transducer Naming
    MIP-X-XX-X-X-XXXX-X-XX-X
    First X - Connector Type
    A - Metri-Pack 150 Series
    E - Cable, 1.0 m length
    F - Cable, 2.0 m length
    Second and Third X - Pressure Connection
    F1 - 1/4-in 45-degree Female Schrader
    G1 - G 1/4 A -G
    G2 - G 1/4 A -L
    M1 - M12 x 1.5
    N1 - 1/4-18 NPT
    N2 - 1/8-27 NPT
    Fourth and Fifth X - Not Defined
    Sixth thru Ninth X - Four Digit Alpha-Numeric Code For Pressure Range (bar or PSI)
    Tenth X - Pressure Reference
    A - Absolute
    S - Sealed Gage (only available at or above 100 psi or 8 bar)
    Eleventh and Twelfth X - Output Type
    AA - Ratiometric, 5.0V Vs: 10% to 90%
    AD - Ratiometric, 5.0 Vs: 10% to 90% Vs
    Thirteenth X - Open
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Number of matching Manufacturers is 1
Number of matching Products is 5
Processing time was 0 seconds