NSF Product and Service Listings
These NSF Official Listings are current as of Saturday, October 25, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0549199&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| IBG HydroTech GmbH | |
| Siemensstraße 39 | |
| D-63755 Alzenau | |
| Germany | |
| 49 604 2956 4200 | |
| Visit this company's website |
Facility : Alzenau, Germany
Protective (Barrier) Materials
| Water | Water | |||
| Water Contact | Contact | Contact | ||
| Trade Designation | Size Restriction | Temp | Material | |
|
Pipe Liner - Immediate Return to Service[1] |
||||
| IBB16 | >=6" | CLD 23 | MLTPL | |
[1] This product requires the following cures:
-Outer layer non-wetted layer is UV cured.
-Inner layer cured using controlled steam in the following manner:
Throughout the duration of the curing process the temperature of the liner outside
laminate must be monitored using an appropriate measuring device and documented on an
installation log. The processing pressure shall also be maintained within recommended
limits and documented for future reference. The minimum laminate temperature required
is 60°C. Keep this temperature for 6 hours. If the laminate temperature is not reached
at any of the measuring points, extend the curing time for every 5°C for 2 hours. A
minimum laminate temperature of 50°C is required. Keep the curing pressure constant at
cooling down and cool down by blowing cold air for not more than 15°C per hour till 35°C
is reached. After active cure is complete, flushing shall be performed per ANSI/AWWA
C651-14 section 4.7 and Appendix B. After flushing, an ambient cure of 39 days is
required.
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 1
Processing time was 0 seconds

