NSF Product and Service Listings

These NSF Official Listings are current as of Saturday, May 18, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0549199&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
IBG HydroTech GmbH 
Siemensstraße 39
D-63755 Alzenau 
Germany 
49 604 2956 4200
Visit this company's website


Facility : Alzenau, Germany

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Pipe Liner - Immediate Return to Service[1]
IBB16 >=6" CLD 23 MLTPL

[1] This product requires the following cures:
    -Outer layer non-wetted layer is UV cured.
    -Inner layer cured using controlled steam in the following manner:
    Throughout the duration of the curing process the temperature of the liner outside
    laminate must be monitored using an appropriate measuring device and documented on an
    installation log.  The processing pressure shall also be maintained within recommended
    limits and documented for future reference.  The minimum laminate temperature required
    is 60°C.  Keep this temperature for 6 hours.  If the laminate temperature is not reached
    at any of the measuring points, extend the curing time for every 5°C for 2 hours.  A
    minimum laminate temperature of 50°C is required.  Keep the curing pressure constant at
    cooling down and cool down by blowing cold air for not more than 15°C per hour till 35°C
    is reached.  After active cure is complete, flushing shall be performed per ANSI/AWWA
    C651-14 section 4.7 and Appendix B.  After flushing, an ambient cure of 39 days is
    required.


Number of matching Manufacturers is 1
Number of matching Products is 1
Processing time was 0 seconds