NSF Product and Service Listings
These NSF Official Listings are current as of Friday, December 26, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0600944&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| Hydronix Water Technology | |
| 8630 Rochester Avenue | |
| Rancho Cucamonga, CA 91730 | |
| United States | |
| 909-527-6996 | |
| Visit this company's website |
Facility : 3C
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Filtration Devices/Components[1] [2] [G] |
||||
| Sediment Bonded Cartridge (SBC-XXYYZZ) | [3] | CLD 23 | PP | |
| Sediment Bonded Cartridge (SBX-XXYYZZ) | [3] | CLD 23 | PP | |
| Sediment Bonded Cartridge (WW-SBXXYYZZ) | [4] | CLD 23 | PP | |
| Sediment Depth Cartridge (SDC-XXYYZZ) | [3] | CLD 23 | PP | |
| Sediment Depth Cartridge (SDX-XXYYZZ) | [3] | CLD 23 | PP | |
| Sediment Depth Cartridge (WW-SDXXYYZZ) | [4] | CLD 23 | PP | |
| Sediment Grooved Cartridge (SGC-XXYYZZ) | [3] | CLD 23 | PP | |
| Sediment Grooved Cartridge (SGX-XXYYZZ) | [3] | CLD 23 | PP | |
| Sediment Grooved Cartridge (WW-SGXXYYZZ) | [4] | CLD 23 | PP | |
| Sediment Wound Cartridge (SWC-XXYYZZ) | [3] | CLD 23 | PP | |
| Sediment Wound Cartridge (SWX-XXYYZZ) | [3] | CLD 23 | PP | |
[1] Certified for point-of-entry (POE) and municipal end uses.
[2] Certification does not include inner core, adapters, o-rings, gaskets, or end caps.
[3] XX - 1.5" – 8" Diameter
YY - 2" – 60" Length
ZZ - 0.5m – 200m Micron Rating
*Special lengths and diameters within the certified range are included in the
certification such as 2 1/4" diameter and 30 1/4" length.
[4] WW - Internal Code AA-ZZ
XX - 1.5" – 8" Diameter
YY - 2" – 60" Length
ZZ - 0.5m – 200m Micron Rating
*Special lengths and diameters within the certified range are included in the
certification such as 2 1/4" diameter and 30 1/4" length.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Reverse Osmosis Element[5] |
||||
| BW-2521-PRO | 2.5" x 21" | CLD 23 | MLTPL | |
| BW-2540-PRO | 2.5" x 40" | CLD 23 | MLTPL | |
| BW-4021-PRO | 4" x 21" | CLD 23 | MLTPL | |
| BW-4040-PRO | 4" x 40" | CLD 23 | MLTPL | |
| BW-8040-PRO | 8" x 40" | CLD 23 | MLTPL | |
| HLE-4040-PRO | 4" x 40" | CLD 23 | MLTPL | |
| HLP-8040-PRO | 8" x 40" | CLD 23 | MLTPL | |
| UHLE-4040-PRO | 4" x 40" | CLD 23 | MLTPL | |
| XHLE-4040-PRO | 4" x 40" | CLD 23 | MLTPL | |
[5] Certified for the following minimum daily flow rates:
BW-2521 is certified for a minimum flow of 300 gallons per day.
BW-2540 is certified for a minimum flow of 800 gallons per day.
BW-4021 is certified for a minimum flow of 1000 gallons per day.
BW-4040 is certified for a minimum flow of 2600 gallons per day.
BW-4040-LP is certified for a minimum flow of 2800 gallons per day.
BW-8040 is certified for a minimum flow of 11500 gallons per day.
BW-8040-LP is certified for a minimum flow of 13000 gallons per day.
These models require the following flush:
BW-2521 requires a 2 hour flush at a flow rate of 2.6 gallons per minute (gpm) with
de-ionized water.
BW-2540 requires a 2 hour flush at a flow rate of 3.7 gallons per minute (gpm) with
BW-4021 requires a 2 hour flush at a flow rate of 8.68 gallons per minute (gpm) with
de-ionized water.
BW-4040 requires a 2 hour flush at a flow rate of 12.04 gallons per minute (gpm) with
de-ionized water.
BW-4040-LP requires a 2 hour flush at a flow rate of 12.96 gallons per minute (gpm)
with de-ionized water.
BW-8040 requires a 2 hour flush at a flow rate of 53.24 gallons per minute (gpm) with
de-ionized water.
BW-8040-LP requires a 2 hour flush at a flow rate of 60.19 gallons per minute (gpm)
with de-ionized water.
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 20
Processing time was 0 seconds