NSF Product and Service Listings
These NSF Official Listings are current as of Saturday, July 12, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0600944&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
Hydronix Water Technology | |
8630 Rochester Avenue | |
Rancho Cucamonga, CA 91730 | |
United States | |
909-527-6996 | |
Visit this company's website |
Facility : 3C
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Filtration Devices/Components[1] [2] [G] |
||||
Sediment Bonded Cartridge (SBC-XXYYZZ) | [3] | CLD 23 | PP | |
Sediment Bonded Cartridge (SBX-XXYYZZ) | [3] | CLD 23 | PP | |
Sediment Bonded Cartridge (WW-SBXXYYZZ) | [4] | CLD 23 | PP | |
Sediment Depth Cartridge (SDC-XXYYZZ) | [3] | CLD 23 | PP | |
Sediment Depth Cartridge (SDX-XXYYZZ) | [3] | CLD 23 | PP | |
Sediment Depth Cartridge (WW-SDXXYYZZ) | [4] | CLD 23 | PP | |
Sediment Grooved Cartridge (SGC-XXYYZZ) | [3] | CLD 23 | PP | |
Sediment Grooved Cartridge (SGX-XXYYZZ) | [3] | CLD 23 | PP | |
Sediment Grooved Cartridge (WW-SGXXYYZZ) | [4] | CLD 23 | PP | |
Sediment Wound Cartridge (SWC-XXYYZZ) | [3] | CLD 23 | PP | |
Sediment Wound Cartridge (SWX-XXYYZZ) | [3] | CLD 23 | PP | |
[1] Certified for point-of-entry (POE) and municipal end uses. [2] Certification does not include inner core, adapters, o-rings, gaskets, or end caps. [3] XX - 1.5" – 8" Diameter YY - 2" – 60" Length ZZ - 0.5m – 200m Micron Rating *Special lengths and diameters within the certified range are included in the certification such as 2 1/4" diameter and 30 1/4" length. [4] WW - Internal Code AA-ZZ XX - 1.5" – 8" Diameter YY - 2" – 60" Length ZZ - 0.5m – 200m Micron Rating *Special lengths and diameters within the certified range are included in the certification such as 2 1/4" diameter and 30 1/4" length. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||
Reverse Osmosis Element[5] |
||||
BW-2521-PRO | 2.5" x 21" | CLD 23 | MLTPL | |
BW-2540-PRO | 2.5" x 40" | CLD 23 | MLTPL | |
BW-4021-PRO | 4" x 21" | CLD 23 | MLTPL | |
BW-4040-PRO | 4" x 40" | CLD 23 | MLTPL | |
BW-8040-PRO | 8" x 40" | CLD 23 | MLTPL | |
HLE-4040-PRO | 4" x 40" | CLD 23 | MLTPL | |
HLP-8040-PRO | 8" x 40" | CLD 23 | MLTPL | |
UHLE-4040-PRO | 4" x 40" | CLD 23 | MLTPL | |
XHLE-4040-PRO | 4" x 40" | CLD 23 | MLTPL | |
[5] Certified for the following minimum daily flow rates: BW-2521 is certified for a minimum flow of 300 gallons per day. BW-2540 is certified for a minimum flow of 800 gallons per day. BW-4021 is certified for a minimum flow of 1000 gallons per day. BW-4040 is certified for a minimum flow of 2600 gallons per day. BW-4040-LP is certified for a minimum flow of 2800 gallons per day. BW-8040 is certified for a minimum flow of 11500 gallons per day. BW-8040-LP is certified for a minimum flow of 13000 gallons per day. These models require the following flush: BW-2521 requires a 2 hour flush at a flow rate of 2.6 gallons per minute (gpm) with de-ionized water. BW-2540 requires a 2 hour flush at a flow rate of 3.7 gallons per minute (gpm) with BW-4021 requires a 2 hour flush at a flow rate of 8.68 gallons per minute (gpm) with de-ionized water. BW-4040 requires a 2 hour flush at a flow rate of 12.04 gallons per minute (gpm) with de-ionized water. BW-4040-LP requires a 2 hour flush at a flow rate of 12.96 gallons per minute (gpm) with de-ionized water. BW-8040 requires a 2 hour flush at a flow rate of 53.24 gallons per minute (gpm) with de-ionized water. BW-8040-LP requires a 2 hour flush at a flow rate of 60.19 gallons per minute (gpm) with de-ionized water. |
Number of matching Manufacturers is 1
Number of matching Products is 20
Processing time was 0 seconds