NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| Protech Water India | |
| Shyam3, 78 Industrial Hub | |
| Panchratna Estate, Changodar | |
| Ahmedabad, Gujarat 382213 | |
| India | |
| 91 982 0032292 | |
| Visit this company's website |
Facility : # 1 China
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Reverse Osmosis Element[1] [2] [3] |
||||
| BW-400 | 8" x 40" | CLD 23 | MLTPL | |
| BW-XFR-4040 | 4" x 40" | CLD 23 | MLTPL | |
| BW-XFR400/34 | 8" x 40" | CLD 23 | MLTPL | |
| LP-4040 | 4" x 40" | CLD 23 | MLTPL | |
| NF90-4040 | 4" x 40" | CLD 23 | MLTPL | |
| NF90400/34 | 8" x 40" | CLD 23 | MLTPL | |
| ULP-4040 | 4" x 40" | CLD 23 | MLTPL | |
| ULP-8040 | 8" x 40" | CLD 23 | MLTPL | |
[1] Certified for the following minimum daily flow rates:
LP-4040 and ULP-4040 are certified for a minimum flow of 2600 gallons per day.
ULP-8040 is certified for a minimum flow of 12000 gallons per day.
BW-400 is certified for a minimum flow of 10500 gallons per day.
BW-XFR400/34 is certified for a minimum flow of 9500 gallons per day.
BW-XFR-4040 is certified for a minimum flow of 2300 gallons per day.
NF90400/34 is certified for a minimum flow of 14500 gallons per day.
NF90-4040 is certified for a minimum flow of 3500 gallons per day.
[2] LP-4040 and ULP-4040 require a 2 hour flush at a flow rate of 1.805 gallons per minute
(gpm) with tap water.
ULP-8040 requires a 2 hour flush at a flow rate of 8.33 gallons per minute (gpm) with
tap water.
BW-400 requires a 2 hour flush at a flow rate of 7.291 gallons per minute (gpm) with tap
water.
BW-XFR400/34 requires a 2 hour flush at a flow rate of 6.597gallons per minute (gpm)
with tap water.
BW-XFR-4040 requires a 2 hour flush at a flow rate of 1.597 gallons per minute (gpm)
with tap water.
NF90400/34 requires a 2 hour flush at a flow rate of 10.069 gallons per minute (gpm)
with tap water.
NF90-4040 requires a 2 hour flush at a flow rate of 2.431 gallons per minute (gpm) with
tap water.
[3] Naming Convention:
ULP - Ultra Low Pressure
LP - Low Pressure
FR - Fouling Resistance and can be used to High Salt water
BW - Bitter water, which can be used for bitter water
|
||||