NSF Product and Service Listings
These NSF Official Listings are current as of Friday, December 26, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0703132&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| Henkel Corporation DBA Fyfe | |
| 1 Henkel Way | |
| Rocky Hill, CT 06067 | |
| United States | |
| 855-708-3617 | |
| Visit this company's website |
Facility : Houston, TX
Protective (Barrier) Materials
| Water | Water | |||
| Water Contact | Contact | Contact | ||
| Trade Designation | Size Restriction | Temp | Material | |
|
Coatings - Fittings [G] |
||||
| LOCTITE® Tyfo® PWC[1] [2] | >= 6" | CLD 23 | EPOXY | |
[1] Number of Coats: 2
Maximum Field Use Dry Film Thickness (in mils): 19
Maximum Thinner: None
Recoat Cure Time and Temperature: 24 hours at 72°F
Final Cure Time and Temperature: 24 hours at 72°F
Special Comments: Mix ratio A:B is 100:32.4 by weight.
[2] Only products bearing the NSF mark are NSF Certified.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Coatings - Pipe |
||||
| LOCTITE® Tyfo® PWC[1] [2] | >= 14" | CLD 23 | EPOXY | |
| LOCTITE® Tyfo® System[2] [3] | >= 36" | CLD 23 | EPOXY | |
[1] Number of Coats: 2
Maximum Field Use Dry Film Thickness (in mils): 19
Maximum Thinner: None
Recoat Cure Time and Temperature: 24 hours at 72°F
Final Cure Time and Temperature: 24 hours at 72°F
Special Comments: Mix ratio A:B is 100:32.4 by weight.
[2] Only products bearing the NSF mark are NSF Certified.
[3] Product Application:
Layer 1: 10 wet mils of Tyfo S. This layer must cure for 1 hour at 75°F. Mix ratio of
Tyfo S Part A:B is 100:34.5 by weight.
Layer 2: 40 wet mils of Tyfo TC, Tyfo S or thickened Tyfo S. No cure time required.
Mix ratio of Tyfo TC Part A:B is 100:23.4 by weight. Mix ratio of Tyfo S Part A:B is
100:34.5 by weight. Thickened Tyfo S is mixed as (Mixed Tyfo S Epoxy) : (Filler
Material) 100:7 Parts by weight. Filler Material may be a combination of fumed silica or
polyethylene fibers.
Layer 3: 8 coats of the reinforcement Layer saturated with Tyfo S. This layer must cure
for 3 hours at 75F. Mix ratio of Part A:B is 100:34.5 by weight. Reinforcement layer
may be a combination of Tyfo SCH-41, Tyfo SCH-41 2X, Tyfo SEH-51A, Tyfo BCC (carbon)
SEH-81A (glass), Tyfo WEB (glass),Tyfo BC (glass), Tyfo SEH-31A (glass), Tyfo SEH-31A
(glass), Tyfo SCH-41S (carbon) and Tyfo SCH-41S-2X (carbon).
Layer 4: 20 wet mils of Thickened Tyfo S. Final cure is 48 hours at 80°F. Minimum Shore
D hardness of 80. Mix ratio of Tyfo S Part A:B is 100:34.5 by weight, then (Mixed Epoxy)
: (Filler Material) 100:7 Parts by weight. If 80 hardness is not achieved, continue
curing in 3 hour intervals. Hardness shall be based on average of 5 measurements.
Filler material may be a combination of fumed silica or polyethylene fibers.
Alternate Part 4: 2 coats (13 we mils each) of Tyfo PWC. First coat must cure for 24
hours at 75°F prior to the application of the second coat. Final cure is 24 hours at
72°F. Mix ratio of Part A:B is 100:32.4 by weight.
|
||||
|
Coatings - Tank |
||||
| LOCTITE® Tyfo® PWC[1] [2] | >= 500 gal. | CLD 23 | EPOXY | |
| LOCTITE® Tyfo® System[2] [3] | >= 2000 gal. | CLD 23 | EPOXY | |
[1] Number of Coats: 2
Maximum Field Use Dry Film Thickness (in mils): 19
Maximum Thinner: None
Recoat Cure Time and Temperature: 24 hours at 72°F
Final Cure Time and Temperature: 24 hours at 72°F
Special Comments: Mix ratio A:B is 100:32.4 by weight.
[2] Only products bearing the NSF mark are NSF Certified.
[3] Product Application:
Layer 1: 10 wet mils of Tyfo S. This layer must cure for 1 hour at 75°F. Mix ratio of
Tyfo S Part A:B is 100:34.5 by weight.
Layer 2: 40 wet mils of Tyfo TC, Tyfo S or thickened Tyfo S. No cure time required.
Mix ratio of Tyfo TC Part A:B is 100:23.4 by weight. Mix ratio of Tyfo S Part A:B is
100:34.5 by weight. Thickened Tyfo S is mixed as (Mixed Tyfo S Epoxy) : (Filler
Material) 100:7 Parts by weight. Filler Material may be a combination of fumed silica or
polyethylene fibers.
Layer 3: 8 coats of the reinforcement Layer saturated with Tyfo S. This layer must cure
for 3 hours at 75F. Mix ratio of Part A:B is 100:34.5 by weight. Reinforcement layer
may be a combination of Tyfo SCH-41, Tyfo SCH-41 2X, Tyfo SEH-51A, Tyfo BCC (carbon)
SEH-81A (glass), Tyfo WEB (glass),Tyfo BC (glass), Tyfo SEH-31A (glass), Tyfo SEH-31A
(glass), Tyfo SCH-41S (carbon) and Tyfo SCH-41S-2X (carbon).
Layer 4: 20 wet mils of Thickened Tyfo S. Final cure is 48 hours at 80°F. Minimum Shore
D hardness of 80. Mix ratio of Tyfo S Part A:B is 100:34.5 by weight, then (Mixed Epoxy)
: (Filler Material) 100:7 Parts by weight. If 80 hardness is not achieved, continue
curing in 3 hour intervals. Hardness shall be based on average of 5 measurements.
Filler material may be a combination of fumed silica or polyethylene fibers.
Alternate Part 4: 2 coats (13 we mils each) of Tyfo PWC. First coat must cure for 24
hours at 75°F prior to the application of the second coat. Final cure is 24 hours at
72°F. Mix ratio of Part A:B is 100:32.4 by weight.
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 5
Processing time was 0 seconds