NSF Product and Service Listings

These NSF Official Listings are current as of Friday, December 26, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0755801&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
Wanhua Chemical Group Co., Ltd. 
No. 59 Chongqing Street
Yantai Econ. and Tech. Dev. Zone 
Yantai, Shandong 264006 
China 
86 535 202 6105
Visit this company's website


Facility : Yantai, Shandong, China

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Reverse Osmosis Element
BW-4040-FR[2] [4] 4" x 40" CLD 23 MLTPL
BW-4040-LP[2] [4] 4" x 40" CLD 23 MLTPL
BW-4040-ULP[2] [4] 4" x 40" CLD 23 MLTPL
BW-8040-400-FR[2] [4] 8" x 40" CLD 23 MLTPL
BW-8040-400-LP[2] [4] 8" x 40" CLD 23 MLTPL
BW-8040-400-ME[2] [4] 8" x 40" CLD 23 MLTPL
BW-8040-400-ULP[2] [4] 8" x 40" CLD 23 MLTPL
BW-8040-400-XFR[2] [4] 8" x 40" CLD 23 MLTPL
BW-8040-440-LP[2] [4] 8" x 40" CLD 23 MLTPL
BW-8040-440-ME[2] [4] 8" x 40" CLD 23 MLTPL
BW-8040-440-ULP[2] [4] 8" x 40" CLD 23 MLTPL
BW-8040-440-XLP[2] [4] 8" x 40" CLD 23 MLTPL
BW-FR[3] [5] CLD 23 MLTPL
BW-LP[3] [5] CLD 23 MLTPL
BW-ME[3] [5] CLD 23 MLTPL
BW-ULP[3] [5] CLD 23 MLTPL
BW-XFR[3] [5] CLD 23 MLTPL
BW-XLP[3] [5] CLD 23 MLTPL
HP200[3] [5] CLD 23 MLTPL
HP200-8040-270[2] [4] 8" x 40" CLD 23 MLTPL
SCW-4040-ULP[2] [4] 4" x 40" CLD 23 MLTPL
SCW-8040-400-ULP[2] [4] 8" x 40" CLD 23 MLTPL
SCW-8040-440-ULP[2] [4] 8" x 40" CLD 23 MLTPL
SCW-ULP[3] [5] CLD 23 MLTPL
SW-4040-HF[2] [4] 4" x 40" CLD 23 MLTPL
SW-4040-HP70[2] [4] 4" x 40" CLD 23 MLTPL
SW-4040-HR[2] [4] 4" x 40" CLD 23 MLTPL
SW-4040-XHF[2] [4] 4" x 40" CLD 23 MLTPL
SW-4040-XHR[2] [4] 4" x 40" CLD 23 MLTPL
SW-8040-370-HP120[2] [4] 8" x 40" CLD 23 MLTPL
SW-8040-400-HF[2] [4] 8" x 40" CLD 23 MLTPL
SW-8040-400-HR[2] [4] 8" x 40" CLD 23 MLTPL
SW-8040-400-XHF[2] [4] 8" x 40" CLD 23 MLTPL
SW-8040-400-XHR[2] [4] 8" x 40" CLD 23 MLTPL
SW-8040-440-HF[2] [4] 8" x 40" CLD 23 MLTPL
SW-8040-440-HP70[2] [4] 8" x 40" CLD 23 MLTPL
SW-8040-440-HR[2] [4] 8" x 40" CLD 23 MLTPL
SW-8040-440-XHF[2] [4] 8" x 40" CLD 23 MLTPL
SW-8040-440-XHR[2] [4] 8" x 40" CLD 23 MLTPL
SW-8040-HP70[2] [4] 8" x 40" CLD 23 MLTPL
SW-HF[3] [5] CLD 23 MLTPL
SW-HP120[3] [5] CLD 23 MLTPL
SW-HP70[3] [5] CLD 23 MLTPL
SW-HR[3] [5] CLD 23 MLTPL
SW-XHF[3] [5] CLD 23 MLTPL
SW-XHR[3] [5] CLD 23 MLTPL
WH-400-PRO[2] [4] 8" x 40" CLD 23 MLTPL
WH-400-PRO1[2] [4] 8" x 40" CLD 23 MLTPL
WH-400-PRO2[2] [4] 8" x 40" CLD 23 MLTPL
WH-400-PRO3[2] [4] 8" x 40" CLD 23 MLTPL
WH-PRO[3] [5] CLD 23 MLTPL
WH-PRO1[3] [5] CLD 23 MLTPL
WH-PRO2[3] [5] CLD 23 MLTPL
WH-PRO3[3] [5] CLD 23 MLTPL
WNF5010[3] [5] CLD 23 MLTPL
WNF5010-8040-400[2] [4] 8" x 40" CLD 23 MLTPL
WNF5010-8040-440[2] [4] 8" x 40" CLD 23 MLTPL
WNF8010[3] [5] CLD 23 MLTPL
WNF8010-8040-400[2] [4] 8" x 40" CLD 23 MLTPL
WNF8020[3] [5] CLD 23 MLTPL
WNF8020-8040-400[2] [4] 8" x 40" CLD 23 MLTPL
WNF9010[3] [5] CLD 23 MLTPL
WNF9010-8040-370-P80[2] [4] 8" x 40" CLD 23 MLTPL
WNF9010-8040-400[2] [4] 8" x 40" CLD 23 MLTPL
WNF9010-P80[3] [5] CLD 23 MLTPL

[2] Filter elements are certified for the following minimum daily (24 hour) permeate
    generation volumes for use in public water treatment facilities:
    BW-8040-400-LP: 9350 gallons
    BW-8040-440-LP: 10285 gallons
    BW-8040-400-FR: 9350 gallons
    BW-8040-400-ULP: 9350 gallons
    BW-8040-440-ULP: 10752 gallons
    BW-8040-400-XFR: 9350 gallons
    BW-8040-440-XLP: 10285 gallons
    BW-8040-400-ME: 8925 gallons
    BW-8040-440-ME: 9817 gallons
    SW-8040-HP70: 7480 gallons
    SW-8040-440-HP70: 8228 gallons
    SW-8040-400-HR: 6375 gallons
    SW-8040-440-HR: 7012 gallons
    SW-8040-400-HF: 7650 gallons
    SW-8040-440-HF: 8415 gallons
    SW-8040-400-XHR: 5100 gallons
    SW-8040-440-XHR: 5610 gallons
    SW-8040-400-XHF: 6993 gallons
    SW-8040-440-XHF: 8376 gallons
    SW-8040-370-HP120: 10200 gallons
    SCW-8040-400-ULP: 9350 gallons
    SCW-8040-440-ULP: 10752 gallons
    BW-4040-FR: 2400 gallons
    BW-4040-LP: 2400 gallons
    BW-4040-ULP: 2400 gallons
    SCW-4040-ULP: 2400 gallons
    SW-4040-HF: 1624 gallons
    SW-4040-HP70: 1588 gallons
    SW-4040-HR: 1353 gallons
    SW-4040-XHF: 1485 gallons
    SW-4040-XHR: 1083 gallons
    WNF5010-8040-400: 10625 gallons
    WNF5010-8040-440: 11687 gallons
    WNF8010-8040-400: 11900 gallons
    WNF8020-8040-400: 9350 gallons
    WNF9010-8040-370-P80: 5440 gallons
    WNF9010-8040-400: 6375 gallons
    HP200-8040-270: 5780 gallons
    WH-400-PRO: 9775 gallons
    WH-400-PRO1: 9775 gallons
    WH-400-PRO2: 9775 gallons
    WH-400-PRO3: 9775 gallons
[3] Membranes are certified to a maximum static surface area to volume ratio of 0.13 liters
    (L) per square meter of membrane surface area, and the following minimum daily (24 hour)
    permeate generation volumes for use in public water treatment facilities:
    BW-FR: 954 liters per square meter of membrane
    BW-LP: 954 liters per square meter of membrane
    BW-ME: 910 liters per square meter of membrane
    BW-ULP: 954 liters per square meter of membrane
    BW-XFR: 954 liters per square meter of membrane
    BW-XLP: 954 liters per square meter of membrane
    SCW-ULP: 954 liters per square meter of membrane
    SW-HF: 780 liters per square meter of membrane
    SW-HP70: 763 liters per square meter of membrane
    SW-HP120: 1125 liters per square meter of membrane
    SW-HR: 650 liters per square meter of membrane
    SW-XHF: 713 liters per square meter of membrane
    SW-XHR: 520 liters per square meter of membrane
    WNF5010: 1084 liters square meter of membrane
    WNF8010: 1214 liters square meter of membrane
    WNF8020: 954 liters per square meter of membrane
    WNF9010: 650 liters per square meter of membrane
    WNF9010-P80: 600 liters per square meter of membrane
    HP200: 873 liters per square meter of membrane
    WH-PRO: 997 liters per square meter of membrane
    WH-PRO1: 997 liters per square meter of membrane
    WH-PRO2: 997 liters per square meter of membrane
    WH-PRO3: 997 liters per square meter of membrane
[4] The following filter elements require a pre-service flush at a flow rate of 12 gallons
    per minute (12 gpm) for 2 hours using deionized water:
    BW-8040-400-LP
    BW-8040-440-LP
    BW-8040-400-FR
    BW-8040-400-ULP
    BW-8040-440-ULP
    BW-8040-400-XFR
    BW-8040-440-XLP
    BW-8040-400-ME
    BW-8040-440-ME
    SW-8040-HP70
    SW-8040-440-HP70
    SW-8040-400-HR
    SW-8040-440-HR
    SW-8040-400-HF
    SW-8040-440-HF
    SW-8040-400-XHR
    SW-8040-440-XHR
    SW-8040-400-XHF
    SW-8040-440-XHF
    SW-8040-370-HP120
    SCW-8040-400-ULP
    SCW-8040-440-ULP
    "BW-4040-FR
    BW-4040-LP
    BW-4040-ULP
    SCW-4040-ULP
    SW-4040-HF
    SW-4040-HP70
    SW-4040-HR
    SW-4040-XHF
     SW-4040-XHR
    WNF5010-8040-400
    WNF5010-8040-440
    WNF8010-8040-400
    WNF8020-8040-400
    WNF9010-8040-370-P80
    WNF9010-8040-400
    HP200-8040-270
    WH-400-PRO
    WH-400-PRO1
    WH-400-PRO2
    WH-400-PRO3
[5] The following membranes require a pre-service immersion in ambient deionized water for
    46 minutes, followed by a deonized water flush on both sides of the membrane for 30
    minutes:
    BW-FR
    BW-LP
    BW-ME
    BW-ULP
    BW-XFR
    BW-XLP
    SCW-ULP
    SW-HF
    SW-HP70
    SW-HP120
    SW-HR
    SW-XHF
    SW-XHR
    WNF5010
    WNF8010
    WNF8020
    WNF9010
    WNF9010-P80"								
    HP200
    WH-PRO
    WH-PRO1
    WH-PRO2
    WH-PRO3

Ultrafiltration Devices[1]
UF-0685-50 160 x 2418 mm CLD 23 MLTPL
UF-0685-65 160 x 2418 mm CLD 23 MLTPL
UF-0770 180 x 1919 mm CLD 23 MLTPL
UF-0860 225 x 1860 mm CLD 23 MLTPL
UF-0880 225 x 2360 mm CLD 23 MLTPL
UF-0880X 225 x 2360 mm CLD 23 MLTPL

[1] Products require a pre-service flush at a flow rate of twelve (12) gallons per minute
    (gpm) for two (2) hours using de-ionized water.
    UF-0860 is certified for a minimum daily flow of 42,000 liters for use in public water
    treatment facilities.
    UF-0880 is certified for a minimum daily flow of 65,000 liters for use in public water
    treatment facilities.
    UF-0880X is certified for a minimum daily flow of 67,000 liters for use in public water
    treatment facilities.
    UF-0770 is certified for a minimum daily flow of 47,000 liters for use in public water
    treatment facilities.
    UF-0685-50 is certified for a minimum daily flow of 42,000 liters for use in public
    water treatment facilities.
    UF-0685-65 is certified for a minimum daily flow of 55,000 liters for use in public
    water treatment facilities.


Number of matching Manufacturers is 1
Number of matching Products is 71
Processing time was 0 seconds