NSF Product and Service Listings
These NSF Official Listings are current as of Saturday, July 12, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0822367&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
AlKawther Industries Co, Ltd. | |
Jeddah Industrial City , ST 33 | |
P.O.Box 7771 | |
Jeddah, 21472 | |
Saudi Arabia | |
00966(12)6360644 | |
Visit this company's website |
Facility : Jeddah, Saudi Arabia
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Microfiltration Devices[1] |
||||
Microfiltration Polypropylene (PP) Cartridge Filter- xx- Filtration Rating YY | 10 in-70 in | D. HOT | MLTPL | |
[1] XX:Length 10 = 10" 20 = 20" 30 = 30" 40 = 40" 50 = 50" 60 = 60" 70 = 70" YY: Pore Size 1=1 m 2=2 m 3=3 m 5=5 m 7=7 m 10=10 m 15=15 m 20=20 m 25=25 m 30=30 m 40=40 m 50=50 m 10" models are certified for a minimum daily permeate generation of 1,000 liters for use in public water treatment facilities. 20" models are certified for a minimum daily permeate generation of 2,000 liters for use in public water treatment facilities. 30" models are certified for a minimum daily permeate generation of 3,000 liters for use in public water treatment facilities. 40" models are certified for a minimum daily permeate generation of 4,000 liters for use in public water treatment facilities. 50" models are certified for a minimum daily permeate generation of 5,000 liters for use in public water treatment facilities. 60" models are certified for a minimum daily permeate generation of 6,000 liters for use in public water treatment facilities. 70" models are certified for a minimum daily permeate generation of 7,000 liters for use in public water treatment facilities. |
Number of matching Manufacturers is 1