NSF Product and Service Listings
These NSF Official Listings are current as of Saturday, July 12, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0840878&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
Shanghai Wancheng Environment Technology Co., Ltd. | |
No. 1 Bldg, No. 185 Ringfeng Road | |
Lixiang Town, Jinshan District | |
Shanghai 201500 | |
China | |
86 153 1727 9558 | |
Visit this company's website |
Facility : IWC China
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Reverse Osmosis Element[1] |
||||
IWCROM BW-4040 | 4" x 40" | CLD 23 | MLTPL | |
IWCROM BW-4040HF | 4" x 40" | CLD 23 | MLTPL | |
IWCROM BW-4040HR | 4" x 40" | CLD 23 | MLTPL | |
IWCROM BW-8040 | 8" x 40" | CLD 23 | MLTPL | |
IWCROM BW-8040HF | 8" x 40" | CLD 23 | MLTPL | |
IWCROM BW-8040HR | 8" x 40" | CLD 23 | MLTPL | |
IWCROM FR-4040 | 4" x 40" | CLD 23 | MLTPL | |
IWCROM FR-8040 | 8" x 40" | CLD 23 | MLTPL | |
IWCROM ULP-4040 | 4" x 40" | CLD 23 | MLTPL | |
IWCROM ULP-4040 HR | 4" x 40" | CLD 23 | MLTPL | |
IWCROM ULP-8040 | 8" x 40" | CLD 23 | MLTPL | |
IWCROM ULP-8040 HR | 8" x 40" | CLD 23 | MLTPL | |
IWCROM XLE-4040 | 4" x 40" | CLD 23 | MLTPL | |
IWCROM XLE-8040 | 8" x 40" | CLD 23 | MLTPL | |
[1] Products require the following pre-service flush using tap water at a pressure not to exceed 50 psi: IWCROM ULP-4040 requires a pre-service flush at a flow rate of 4 GPM (gallons per minute) for 24 hours. IWCROM ULP-8040 requires a pre-service flush at a flow rate of 12 GPM (gallons per minute) for 24 hours. IWCROM ULP-4040 HR requires a pre-service flush at a flow rate of 4 GPM (gallons per minute) for 24 hours. IWCROM ULP-8040 HR requires a pre-service flush at a flow rate of 12 GPM (gallons per minute) for 24 hours. IWCROM BW-4040HR requires a pre-service flush at a flow rate of 4 GPM (gallons per minute) for 24 hours. IWCROM BW-8040HR requires a pre-service flush at a flow rate of 12 GPM (gallons per minute) for 24 hours. IWCROM BW-4040HF requires a pre-service flush at a flow rate of 4 GPM (gallons per minute) for 24 hours. IWCROM BW-8040HF requires a pre-service flush at a flow rate of 12 GPM (gallons per minute) for 24 hours. IWCROM BW-4040 requires a pre-service flush at a flow rate of 4 GPM (gallons per minute) for 24 hours. IWCROM BW-8040 requires a pre-service flush at a flow rate of 12 GPM (gallons per minute) for 24 hours. IWCROM FR-4040 requires a pre-service flush at a flow rate of 4 GPM (gallons per minute) for 24 hours. IWCROM FR-8040 requires a pre-service flush at a flow rate of 12 GPM (gallons per minute) for 24 hours. IWCROM XLE-4040 requires a pre-service flush at a flow rate of 4 GPM (gallons per minute) for 24 hours. IWCROM XLE-8040 requires a pre-service flush at a flow rate of 12 GPM (gallons per minute) for 24 hours. |
Number of matching Manufacturers is 1
Number of matching Products is 14
Processing time was 0 seconds