NSF Product and Service Listings
These NSF Official Listings are current as of Friday, December 26, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0881839&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| ICON PROCESS CONTROLS LTD., | |
| 1075 NORTH SERVICE RD. W. UNIT 1-4 | |
| OAKVILLE | |
| ON L6M 2G2 | |
| Canada | |
| +1-905-469-9283 | |
| Visit this company's website |
Facility : #1CA
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Switches/Sensors |
||||
| TIA-B-C-D-E[1] [G] | 1 - 24" | CLD 23 | MLTPL | |
[1] Nomenclature: TIA-B-C-D-E
A - Type
B - Battery type flow meter & flow total meter 1” - 24”
P - Flow rate meter & flow total meter with Pulse | RS-485 CLD 23
M - Flow rate meter & flow total meter with Pulse | 4-20mA | Voltage
W - Flow meter with transmitter
R - Flow rate meter with Pulse | 4-20mA Water Contact Material MLTPL
F - Flow rate meter & flow total meter (batching) with 2x Relay
B - Material of inserting tube:
P - for PVC
C - Length of inserting tube
S - for Pipe 1” – 4”
L - for Pipe 6” – 24”
D - Function option
Non - Standard type
R - TIP type with MODBUS RTU
E – Type of Seals
Non - Viton
E - EPDM
K - FFKM (Kalrez®)
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
|
Water Meters |
||||
| TKA-B-C-D-E[2] [G] | 15 - 100 mm | CLD 23 | MLTPL | |
[2] Nomenclature of TK Series Paddle Flow Sensor & Flow Meter: TKA-B-C-D-E
A - Type
B - Battery type LCD flow rate meter & flow total meter
S - Flow rate meter with Pulse | Relay
P - Flow rate meter & flow total meter with Pulse | RS485
M - Flow rate meter & flow total meter with Pulse | 4-20mA
W - Flow sensor with Pulse | Voltage | 4-20mA
B - Pipe size
15 - 1/2” (DN 15)
20 - 3/4” (DN 20)
25 - 1” (DN 25)
40 - 1 1/2” (DN 40)
50 - 2” (DN 50)
65 - 2 1/2” (DN 65)
80 - 3” (DN 80)
100 - 4” (DN 100)
C - Function option
Non - Standard type
RS - TKP type with MODBUS communication
A - TKW type with transmitter (4 - 20 mA)
V - TKW type with transmitter (0 – 5 V)
PA - TKW type with 4-20mA + pulse output
D - Material of union:
P - for PVC
E – Type of Seals
Non - Viton
E - EPDM
K - FFKM (Kalrez®)
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 2
Processing time was 0 seconds