NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0887469&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
| Environmental World Products (China) Inc | |
| No.3, Lane 1015, South Boxue Road, Malu Town, Jiading District | |
| Shanghai, | |
| China | |
| 021-59153059 |
Facility : # 1 China
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Reverse Osmosis Element[1] [G] |
||||
| BW-4040 | 4" x 40" | CLD 23 | MLTPL | |
| ECO-4040 | 4" x 40" | CLD 23 | MLTPL | |
| ECO-8040 | 8" x 40" | CLD 23 | MLTPL | |
| FR-4040 | 4" x 40" | CLD 23 | MLTPL | |
| FR-8040 | 8" x 40" | CLD 23 | MLTPL | |
| PAN-BW8040HR | 8" x 40" | CLD 23 | MLTPL | |
| PAN-ULP4040HF | 4" x 40" | CLD 23 | MLTPL | |
| PAN-ULP4040HR | 4" x 40" | CLD 23 | MLTPL | |
| PAN-ULP8040HF | 8" x 40" | CLD 23 | MLTPL | |
| PAN-ULP8040HR | 8" x 40" | CLD 23 | MLTPL | |
| PAN-ULP8040SHF | 8" x 40" | CLD 23 | MLTPL | |
| ULP-4040 | 4" x 40" | CLD 23 | MLTPL | |
[1] ECO-4040 and ULP-4040 require a pre-service flush at 1.875 gallons per minute (gpm) for
6 hours using tap water.
ECO-8040, PAN-ULP8040HF and PAN-BW8040HR require a pre-service flush at 8.33
gallons per minute (gpm) for 6 hours using tap water.
PAN-ULP8040HR and FR-8040 require a pre-service flush at 7.29 gallons per minute
(gpm) for 6 hours using tap water.
BW-4040 and FR-4040 require a pre-service flush at 1.67 gallons per minute (gpm)
for 6 hours using tap water.
PAN-ULP8040SHF requires a pre-service flush at 9.71 gallons per minute (gpm) for
6 hours using tap water.
PAN-ULP4040HR requires a pre-service flush at 1.53 gallons per minute (gpm) for
6 hours using tap water.
PAN-ULP4040HF requires a pre-service flush at 2.153 gallons per minute (gpm) for
6 hours using tap water.
PAN-ULP4040HR is certified for a minimum daily flow of 2200 gallons per day for
use in public water treatment facilities.
BW-4040 and FR-4040 are certified for a minimum daily flow of 2400 gallons per
day for use in public water treatment facilities.
ECO-4040 and ULP-4040 are certified for a minimum daily flow of 2700 gallons per
day for use in public water treatment facilities.
PAN-ULP4040HF is certified for a minimum daily flow of 3100 gallons per day for
use in public water treatment facilities.
PAN-ULP8040HR and FR-8040 are certified for a minimum daily flow of 10500
gallons per day for use in public water treatment facilities.
ECO-8040, PAN-ULP8040HF and PAN-BW8040HR are certified for a minimum daily flow
of 12000 gallons per day for use in public water treatment facilities.
PAN-ULP8040SHF is certified for a minimum daily flow of 14000 gallons per day
for use in public water treatment facilities."
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 12
Processing time was 0 seconds