NSF/ANSI 40
Residential Wastewater Treatment Systems
Residential Wastewater Treatment Systems
| Eljen Corporation | |
| 90 Meadow Road | ![]() |
| Windsor, CT 06095 | |
| United States | |
| 800-444-1359 | |
| 860-610-0426 |
Facility : Windsor, CT
| Model Number | Rated Capacity Gallons/Day |
Classification | ||
|
Eljen GSF Denitrification System |
||||
| DN450 | 450 | Class I | ||
| DN600 | 600 | Class I | ||
| DN800 | 800 | Class I | ||
| DN1000 | 1000 | Class I | ||
|
GSF Advanced Treatment (AT) Systems[1] [2] [3] [4] [5] [6] |
||||
| LT-450 | 450 | Class I | ||
| SP-450 | 450 | Class I | ||
| LT-600 | 600 | Class I | ||
| SP-600 | 600 | Class I | ||
| LT-750 | 750 | Class I | ||
| SP-750 | 750 | Class I | ||
| LT-900 | 900 | Class I | ||
| SP-900 | 900 | Class I | ||
| LT-1050 | 1050 | Class I | ||
| SP-1050 | 1050 | Class I | ||
| LT-1200 | 1200 | Class I | ||
| SP-1200 | 1200 | Class I | ||
| LT-1350 | 1350 | Class I | ||
| SP-1350 | 1350 | Class I | ||
| LT-1500 | 1500 | Class I | ||
| SP-1500 | 1500 | Class I | ||
[1] Prefix SP denotes combined or bottomless discharge. Prefix LT denotes single point
discharge.
[2] Table A, Minimum Sizing and Dimensions
NSF 40 Class I Certified GSF Advanced Treatment (AT) Systems SP and LT Models
Model Number Design Daily Minimum Minimum Units
Flow Total Footprint Tank Size Required
(ft2) (gal.)
SP-450 & LT-450 450 225 1000 18
SP-600 & LT-600 600 297 1250 24
SP-750 & LT-750 750 369 1500 30
SP-900 & LT-900 900 441 2000 36
SP-1050 & LT-1050 1050 513 2250 42
SP-1200 & LT-1200 1200 585 2500 48
SP-1350 & LT-1350 1350 657 2750 54
SP-1500 & LT-1500 1500 729 3000 60
[3] Maximum loading rate of 3 gallons per square foot onto the Eljen GSF Media, while
maintaining a maximum hydraulic loading to the underlying soil system as 2 gallons
per square foot per day. The GSF Advanced Treatment (AT) Systems can be installed in
a bed configuration with a minimum spacing along both sides of modules of 6 inches.
A minimum of 6 inches of Specified Sand is placed at the beginning and end of each row.
[4] Minimum requirement of 6 inches of system sand below the GSF Wastewater Treatment System.
[5] While the GSF Advanced Treatment (AT) Systems includes design specifications similar to
a dispersal field, the scope of the NSF/ANSI Standard 40 Class I Certification does NOT
include management methods for the treated effluent discharged from the system.
[6] The GSF Advanced Treatment (AT) Systems are approved with the modules A66 (6 inch
height), A42 (7 inch height), and B43 (7 inch height, 36 inches wide).
|
||||