NSF Product and Service Listings
These NSF Official Listings are current as of Monday, July 04, 2022 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?ProductType=Refrigerator+Filter&hdModlStd=ModlStd&
Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.
NSF/ANSI 42
Drinking Water Treatment Units - Aesthetic Effects
Drinking Water Treatment Units - Aesthetic Effects
A.O. Smith Corporation | |
11270 West Park Place | |
Milwaukee, WI 53224 | |
United States | |
800-527-1953 |
Facility : Haltom City, TX
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
AO-FF | AO-US-100-R | 200 | .5(1) | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
AGA IMPORTS LLC | |
70 Canary Drive | |
Lakewood, NJ 08701 | |
United States | |
917-533-0138 |
Facility : # 3 China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] |
||||||
CWMF003-S[Pb] | CWMF003 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
CWMF004-S[Pb] | CWMF004 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
CWMF021-S[Pb] | CWMF021 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
CWMF022-S[Pb] | CWMF022 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
CWMF031-S[Pb] | CWMF031 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
CWMF032-S[Pb] | CWMF032 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
CWMF035-S | CWMF035 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
CWMF041-S[Pb] | CWMF041 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
CWMF042-S[Pb] | CWMF042 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
CWMF046-S | CWMF046 | 200 | .5 | Nominal Particulate Reduction, Class I | ||
CWMF051-S[Pb] | CWMF051 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GVF033-S | GVF033 | 200 | .3 | Nominal Particulate Reduction, Class I | ||
GVF035-S | GVF035 | 300 | .47 | Nominal Particulate Reduction, Class I | ||
GVF041-S | GVF041 | 200 | .5 | Nominal Particulate Reduction, Class I | ||
GVF042-S | GVF042 | 200 | .41 | Nominal Particulate Reduction, Class I | ||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Altwell Tech Inc. | |
42-24, Daehwa-ro 150 beon-gil | |
Daedeok-gu, Daejeon | |
Korea, Republic of | |
888-637-3338 | |
213-637-5800 |
Facility : Daejeon, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
DA97-08006A-E[Pb] | DA29-00020B | 300(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Aquamor, LLC | ![]() |
42188 Rio Nedo | |
Temecula, CA 92590 | |
United States | |
866-218-8473 | |
951-541-9517 | |
Visit this company's website |
Facility : Temecula, CA
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
AQB-1 | AQB-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart A-1 | A-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart F-8 | F-8 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart G-1 | G-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart G-2 | G-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart G-3 | G-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart G-4 | G-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart G-6 | G-6 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart G-7 | G-7 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart H-1 | H-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart L-1 | L-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart L-2 | L-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart L-3 | L-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart L-4 | L-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart L-5 | L-5 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart M-1 | M-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart M-2 | M-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart S-1 | S-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart S-2 | S-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart S-4 | S-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart W-1 | W-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart W-2 | W-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart W-3 | W-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EarthSmart W-4 | W-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-F8 | GS-F8 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-G1 | GS-G1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-G2 | GS-G2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-G3 | GS-G3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-G4 | GS-G4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-H1 | GS-H1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-L1 | GS-L1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-L2 | GS-L2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-L3 | GS-L3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-L4 | GS-L4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-L5 | GS-L5 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-M1 | GS-M1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-M2 | GS-M2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-S1 | GS-S1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-S2 | GS-S2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-S4 | GS-S4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-W2 | GS-W2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GoldSeries GS-W4 | GS-W4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMA-1 | FMA-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMF-8 | FMF-8 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMG-1 | FMG-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMG-2 | FMG-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMG-3 | FMG-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FML-1 | FML-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FML-1-S | FML-1-S | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FML-2 | FML-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FML-3 | FML-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FML-3-S | FML-3-S | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FML-4 | FML-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FML-4-S | HDX FML-4-S | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FML-5 | HDX FML-5 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FML-5-S | HDX FML-5-S | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMM-1 | FMM-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMM-2 | FMM-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMM-2-S | FMM-2-S | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMS-1 | FMS-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMS-1-S | FMS-1-S | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMS-2 | FMS-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMS-2-S | FMS-2-S | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMS-4 | HDX FMS-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMW-2 | FMW-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMW-2-S | FMW-2-S | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMW-3 | FMW-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
HDX FMW-4 | FMW-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source A-1 | A-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source A-1-2 | A-1-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source F-8 | F-8 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source F-8-2 | F-1-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source G-1 | G-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source G-1-2 | G-1-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source G-2 | G-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source G-2-2 | G-2-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source G-3 | G-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source G-3-2 | G-3-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source G-4 | G-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source G-4-2 | G-4-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source H-1 | H-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source H-1-2 | H-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source L-1 | L-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source L-1-2 | L-1-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source L-2 | L-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source L-2-2 | L-2-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source L-3 | L-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source L-3-2 | L-3-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source L-4 | L-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source L-4-2 | L-4-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source L-5 | L-5 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source L-5-2 | L-5-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source M-1 | M-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source M-1-2 | M-1-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source M-2 | M-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source M-2-2 | M-2-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source S-1 | S-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source S-1-2 | S-1-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source S-2 | S-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source S-2-2 | S-2-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source S-4 | S-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source S-4-2 | S-4-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source W-1 | W-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source W-1-2 | W-1-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source W-2 | W-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source W-2-2 | W-2-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source W-4 | W-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
Project Source W-4-2 | W-4-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-A1 | SW-A1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-F8 | SW-F8 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-G1 | SW-G1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-G2 | SW-G2 | 300 | .5 | Taste and Odor Reduction Chlorine Reduction |
||
SafeWater SW-G3 | SW-G3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-G4 | SW-G4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-G6 | SW-G6 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-G7 | SW-G7 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-H1 | SW-H1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-L1 | SW-L1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-L2 | SW-L2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-L3 | SW-L3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-L4 | SW-L4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-L5 | SW-L5 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-M1 | SW-M1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-M2 | SW-M2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-S1 | SW-S1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-S2 | SW-S2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-S4 | SW-S4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-W1 | SW-W1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-W2 | SW-W2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-W3 | SW-W3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SafeWater SW-W4 | SW-W4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSA-1 | WSA-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSF-8 | WSF-8 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSG-1 | WSG-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSG-2 | WSG-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSG-3 | WSG-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSG-4 | WSG-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSG-6 | WSG-6 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSG-7 | WSG-7 | 3800 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSH-1 | WSH-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSL-1 | WSL-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSL-2 | WSL-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSL-3 | WSL-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSL-4 | WSL-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSL-5 | WSL-5 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSM-1 | WSM-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSM-2 | WSM-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSS-1 | WSS-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSS-2 | WSS-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSS-4 | WSS-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSW-1 | WSW-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSW-2 | WSW-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSW-3 | WSW-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WaterSentinel WSW-4 | WSW-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Aquazon Solutions Inc. | |
9720 Coit Road | |
Suite 220 307 | |
Plano, TX 75025 | |
United States | |
1 4697400561 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
N/A | ||||||
N/A | ||||||
N/A | ||||||
PP-RWF0100A-S | PP-RWF0100A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF0300A-S | PP-RWF0300A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF0400A-S | PP-RWF0400A | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF0500A-S | PP-RWF0500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF0600A-S | PP-RWF0600A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF0700A-S | PP-RWF0700A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF0900A-S | PP-RWF0900A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF1100A-S | PP-RWF1100A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF1200A-S | PP-RWF1200A | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF1300A-S | PP-RWF1300A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF1400A-S | PP-RWF1400A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF1500A-S | PP-RWF1500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF2000A-S | PP-RWF2000A | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF2900A-S | PP-RWF2900A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF3000A-S | PP-RWF3000A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF3100A-S | PP-RWF3100A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF3300A-S | PP-RWF3300A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF3400A-S | PP-RWF3400A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF3500A-S | PP-RWF3500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWF3600A-S | PP-RWF3600A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-RWFS1200AH | PP-RWF1200AH | 200 | .5 | Nominal Particulate Reduction, Class I | ||
PP-WFC2500A-S | PP-WFC2500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-WFC2600A-S | PP-WFC2600A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-WFC2800A-S | PP-WFC2800A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Best Things USA LLC | |
1607 Taft Street | |
Hollywood, FL 33020 | |
United States | |
764-231-2023 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
PP-DA29-00003G-S | PP-DA29-00003G | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-LT500P-S | PP-LT500P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-LT600P-S | PP-LT600P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-MWF-S | PP-MWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PP-UKF7003-S | PP-UKF7003 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Ekeytel, LLC | |
3422 Southwest 106th Avenue | |
Miami, FL 33165 | |
United States | |
786-580-4007 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
DWF-1-S | DWF-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-11-S | DWF-11 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-12-S | DWF-12 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-14-S | DWF-14 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-15-S | DWF-15 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-20-S | DWF-20 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-30-S | DWF-30 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-35-S | DWF-35 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-36-S | DWF-36 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-37-S | DWF-37 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-5-S | DWF-5 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-6-S | DWF-6 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-7-S | DWF-7 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DWF-9-S | DWF-9 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
N/A | ||||||
N/A | ||||||
N/A | ||||||
WFC1001-S | WFC1001 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC1201-s | WFC1201 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC1401-S | WFC1401 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC1801-S | WFC1801 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC1802-S | WFC1802 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC2201-S | WFC2201 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC2401-S | WFC2401 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC2701-S | WFC2701 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC3001-S | WFC3001 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC6001-S | WFC6001 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC7201-S | WFC7201 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Electrolux Home Products | |
10200 David Taylor Drive | |
Charlotte, NC 28262 | |
United States | |
877-435-3287 | |
980-236-2000 | |
Visit this company's website |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Prochill NGPT[2] | RWFVRF1 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
Pure Advantage NGFC-2000 | FC-100 FC-300 |
400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage NGFC-2000 | EWF2CBPA | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage PWF-1[5] | EPPWFU01 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage PWF-1-U[6] | EPPWFU01 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage Ultra[3] | EWF02 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage Ultra-U[4] | EWF02 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource 2 NGFC-2000 | FC-100 | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource 3 | WF3CB | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource Ultra | ULTRAWF | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource Ultra II[7] | EPTWFU01 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource Ultra II-U[8] | EPTWFU01 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
pure advantage ™ NGFC-2000 | WF2CB | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] ProChill NGPT with Performance Indicator Device. [3] PureAdvantage Ultra with Performance Indicator Device. [4] PureAdvantage Ultra-U without Performance Indicator Device. [5] PureAdvantage PWF-1 with Performance Indicator Device. [6] PureAdvantage PWF-1-U without Performance Indicator Device. [7] PureSource Ultra II with Performance Indicator Device. [8] PureSource Ultra II-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Singapore, Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Prochill NGPT[2] | RWFVRF1 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage NGFC-2000 | EWF2CBPA | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage PWF-1[5] | EPPWFU01 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage PWF-1-U[6] | EPPWFU01 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage PWF-2[9] | EPPWFU02 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage Ultra[3] | EWF02 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage Ultra-U[4] | EWF02 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource 2 NGFC-2000 | FC-100 | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource 3 | WF3CB | 200 | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource Ultra | ULTRAWF | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource Ultra II[7] | EPTWFU01 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource Ultra II-U[8] | EPTWFU01 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
pure advantage ™ NGFC-2000 | WF2CB | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
pure advantage™ NGFC-2000 | FC-100 FC-300 |
400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] ProChill NGPT with Performance Indicator Device. [3] PureAdvantage Ultra with Performance Indicator Device. [4] PureAdvantage Ultra-U without Performance Indicator Device. [5] PureAdvantage PWF-1 with Performance Indicator Device. [6] PureAdvantage PWF-1-U without Performance Indicator Device. [7] PureSource Ultra II with Performance Indicator Device. [8] PureSource Ultra II-U without Performance Indicator Device. [9] PureAdvantage PWF-2 with Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Filters Fast | |
13950 Ballantyne Corporate Place | |
Suite 100 | |
Charlotte, NC 28277 | |
United States | |
704-234-3711 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
FF21700-S | FF21700 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FFUS-003-S | FFUS-003 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FFUS-004-S | FFUS-004 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PH21100-S | PH21100 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PH21110-S | PH21110 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PH21200-S | PH21200 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PH21210-S | PH21210 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PH21220-S | PH21220 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PH21300-S | PH21300 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PH21310-S | PH21310 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PH21410-S | PH21410 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PH21420-S | PH21420 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PH21500-S | PH21500 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Foshan Micro Midea Filter Mfg. Co., Ltd. | |
B Area Cherry Blossom Park | |
No. 19 Lingang Road, Bejiao Town Shunde | |
Foshan, Guangdong 528311 | |
China | |
86 135 9090 8470 |
Facility : Foshan, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
M-SJWF200 | SJWF200 | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
MF-2008-R2 | MF-2008-R2R NS-WF26SS0-1 MIWF6200 MIWFT2100 |
200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
MF-2008-TG | WF200 | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
MFCMG14211F[Pb] | MFCMG14211FR | 300(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class III Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Freshlab LLC | |
9473 NW 24th Road | |
Gainesville, FL 32606 | |
United States | |
352-870-5923 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
FF-S-9010 | FF-N-9010 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FF-S-9490 | FF-N-9490 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FF-S-9690 | FF-N-9690 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FF-S-AF01 | FF-N-AF01 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FF-S-DA2900003G | FF-N-DA2900003G | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FF-S-DA2900020B | FF-N-DA2900020B | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FF-S-FR09 | FF-N-FR09 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FF-S-GSWF | FF-N-GSWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FF-S-LT500P | FF-N-LT500P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FF-S-MSWF | FF-N-MSWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FF-S-MWF | FF-N-MWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FF-S-UKF8003 | FF-N-UKF8003 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Frigidaire Home Products | |
10200 David Taylor Drive | |
Charlotte, NC 28262 | |
United States | |
1-800-559-7569 | |
980-236-2000 |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Frigidaire PureSource 3 | WF3CB | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
Frigidaire PureSource Ultra | ULTRAWF | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PurePour PWF-1 | EPPWFU01 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PurePour WF-1[2] | FPPWFU01 | 125 | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PurePour WF-1-U[3] | FPPWFU01 | 200 | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource Ultra II | EPTWFU01 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PurePour WF-1 with Performance Indicator Device. [3] PurePour WF-1-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Frigidaire PureSource 3 | WF3CB | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
Frigidaire PureSource Ultra | ULTRAWF | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PurePour Connect PWF-2[2] | FPPWFU02 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PurePour PWF-1 | EPPWFU01 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PurePour PWF-1[3] | FPPWFU01 | 125 | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PurePour WF-1-U[4] | FPPWFU01 | 200 | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PurePour WF-2[5] | FPPWFU02 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureSource Ultra II | EPTWFU01 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PurePour Connect PWF-2 with Performance Indicator Device. [3] PurePour WF-1-M with Performance Indicator Device. [4] PurePour WF-1-U without Performance Indicator Device. [5] PurePour WF-2 with Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Guangzhou JDone Network Co., Ltd. | ![]() |
Room 212, Building 22 | |
No. 67, Dongpu Second Road | |
Tianhe District, Guangzhou | |
China | |
86 208 203 8036 | |
Visit this company's website |
Facility : Guangdong, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] |
||||||
WHT-F01 | WHT-F01 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WHT-F02 | WHT-F02 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WHT-FF100 | WHT-FF100 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WHT-FF101 | WHT-FF101 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WHT-FF102 | WHT-FF102 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WHT-FF103 | WHT-FF103 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WHT-FF105 | WHT-FF105 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WHT-FF106 | WHT-FF106 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WHT-FF107 | WHT-FF107 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WHT-FF108 | WHT-FF108 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WHT-FF109 | WHT-FF109 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. |
Instapure Brands, Inc. | |
P.O. Box 271850 | |
Fort Collins, CO 80527 | |
United States | |
970-212-4100 |
Facility : # 1 USA
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
REF-IPA-1 | REF-IPA-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPG-1 | REF-IPG-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPG-2 | REF-IPG-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPG-3 | REF-IPG-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPG-4 | REF-IPG-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPL-1 | REF-IPL-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPL-2 | REF-IPL-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPL-3 | REF-IPL-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPL-4 | REF-IPL-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPL-5 | REF-IPL-5 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPM-1 | REF-IPM-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPM-2 | REF-IPM-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPS-1 | REF-IPS-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPS-2 | REF-IPS-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPW-2 | REF-IPW-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPW-3 | REF-IPW-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
REF-IPW-4 | REF-IPW-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
JFL Distributors Inc. / Pure Green Water Filters | |
1251 42nd Street Brooklyn | |
New York, NY 11219 | |
United States | |
800-659-6658 | |
347-534-4955 | |
Visit this company's website |
Facility : Guangdong, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] |
||||||
PG-4396508 | PG-4396508 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PG-4396508A | PG-4396508A | 300 | .31 | Chlorine Reduction Taste and Odor Reduction |
||
PG-500P | PG-500P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PG-600P | PG-600P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PG-700P | PG-700P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PG-700PA | PG-700PA | 200 | .31 | Chlorine Reduction Taste and Odor Reduction |
||
PG-8001 | PG-8001 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PG-8001A | PG-8001A | 300 | .31 | Chlorine Reduction Taste and Odor Reduction |
||
PG-800P | PG-800P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PG-DA03 | PG-DA03 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PG-DA20 | PG-DA20 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PG-DA20A | PG-DA20A | 300 | .31 | Chlorine Reduction Taste and Odor Reduction |
||
PG-GSWF | PG-GSWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PG-MWF | PG-MWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PG-MWFA | PG-MWFA | 300 | .31 | Chlorine Reduction Taste and Odor Reduction |
||
PG-RPWF | PG-RPWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. |
Jietai Purification Tech Co., Ltd. | |
No. 2, Meiping Street | |
Maling Village, Southern District | |
Zhongshan, Guangdong 528455 | |
China | |
86 760 8831 9329 | |
Visit this company's website |
Facility : Guangdong, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] |
||||||
JPR-20B | JPR-20B | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JPR-3G | JPR-3G | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JPR-500P | JPR-500P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JPR-600P | JPR-600P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JPR-700P | JPR-700P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JPR-8001 | JPR-8001 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JPR-800P | JPR-800P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JPR-800P | JPR-800P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JPR-F5 | JPR-F5 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JPR-GSWF | JPR-GSWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JPR-MWF | JPR-MWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JPR-RPWF | JPR-RPWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JTB-1385 | JTB-1385 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JTB-1386 | JTB-1386 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JTB-1387 | JTB-1387 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JTB-1388 | JTB-1388 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JTB-1391 | JTB-1391 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JTB-1393 | JTB-1393 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JTB-1394 | JTB-1394 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JTB-1397 | JTB-1397 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JTB-1398 | JTB-1398 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JTB-1398 | JTB-1398 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JTB-1399 | JTB-1399 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
JTB-1401 | JTB-1401 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-01G3 | WQ-01G3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-85G1 | WQ-85G1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-86S1 | WQ-86S1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-87S2 | WQ-87S2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-88M1 | WQ-88M1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-91L1 | WQ-91L1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-93W3 | WQ-93W3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-94G2 | WQ-94G2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-97L2 | WQ-97L2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-98L3 | WQ-98L3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-98L3 | WQ-98L3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-99L4 | WQ-99L4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-BX-G1 | WQ-BX-G1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-BX-G2 | WQ-BX-G2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-BX-G3 | WQ-BX-G3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-BX-L1 | WQ-BX-L1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-BX-L2 | WQ-BX-L2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-BX-L3 | WQ-BX-L3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-BX-L3 | WQ-BX-L3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-BX-L4 | WQ-BX-L4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-BX-M1 | WQ-BX-M1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-BX-S1 | WQ-BX-S1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-BX-S2 | WQ-BX-S2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WQ-BX-W3 | WQ-BX-W3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. |
JJ IMPORTS LLC | |
593 Vanderbilt Avenue | |
Suite 245 | |
Brooklyn, NY 11238 | |
United States | |
800-380-9110 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
PL-100-S | PL-100 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-1100-S | PL-1100 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-1200-S | PL-1200 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-1300-S | PL-1300 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-1400-S | PL-1400 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-1800-S | PL-1800 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-200-S | PL-200 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-2500-S | PL-2500 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-2700-S | PL-2700 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-2800-S | PL-2800 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-3200-S | PL-3200 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-400-S | PL-400 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-500-S | PL-500 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-600-S | PL-600 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-700-S | PL-700 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-900-S | PL-900 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
JJ imports LLC | |
319 East 54 Street | |
Elmwood Park, NJ 07407 | |
United States | |
800-380-9110 | |
Visit this company's website |
Facility : # 1 China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
PL-100 | PL-100 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-1100 | PL-1100 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-1200 | PL-1200 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-1300 | PL-1300 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-1400 | PL-1400 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-200 | PL-200 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-400 | PL-400 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-500 | PL-500 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-600 | PL-600 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-700 | PL-700 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PL-800 | PL-800 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
K&J Products LLC | |
24033 Madaca Ln Unit 204 | |
Port Charlotte, FL 33954 | |
United States | |
774-239-6576 | |
Visit this company's website |
Facility : # 1 China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
4 Filter-S | 4 Filter | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
5 Filter-S | 5 Filter | 300 | .5 | Taste and Odor Reduction Chlorine Reduction |
||
KJ 20B-S | KJ 20B | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
KJ 3G-S | KJ 3G | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
KJ 500-S | KJ 500 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
KJ 600-S | KJ 600 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
KJ 700-S | KJ 700 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
KJ 800-S | KJ 800 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
KJ GSWF-S | KJ GSWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
KJ MWF-S | KJ MWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
KJ RPWF-S | KJ RPWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
LG Electronics Inc. | |
170,Seongsanpaechong-ro | |
Seongsan-gu, Changwon-si | |
Gyeongsangnam-do, 642-711 | |
Korea, Republic of | |
82 55 268 4622 | |
Visit this company's website |
Facility : Gyeongsangnam-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
MDJ64844601 | LT1000P LT1000PC LT1000PCS |
200(1) | 0.5 | Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Microfilter Co., Ltd. | ![]() |
15-1, Gwinong 3-gil, Deoksan-eup | |
(162-1 Sansuri, Deoksan-eup) | |
Jincheon-gun, Chungcheongbuk-do | |
27856, | |
Korea, Republic of | |
82 43 536 5221 | |
Visit this company's website |
Facility : # 1 Chungcheongbuk-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
DA97-08006A-1[Pb] | DA29-00020B-1 DA29-00020B |
300 | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
DA97-08006A-2[Pb] | DA29-00020B-1 DA29-00020B |
300 | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Chungcheongbuk-Do, Korea, Republic of
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
8001036935 | 8001045102 | 250(1) | .55 | Chloramine Reduction Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
DA97-08006A-1[Pb] | DA29-00020B DA29-00020B-1 |
300(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
DA97-08006A-2[Pb] | DA29-00020B DA29-00020B-1 |
300(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
MORE Pure Inc. | |
2506 Blackberry Lane Northeast | |
Grand Rapids, MI 49525 | |
United States | |
800-284-2866 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
MPF15020-S | MPF15020 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
MPF15090-S | MPF15090 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
MPF15350-S | MPF15350 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
MPF16025-S | MPF16025 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
MPF16095-S | MPF16095 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
MPF16245-S | MPF16245 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
MPF16253-S | MPF16253 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
NOME TRADE Inc. | |
133 W Garvey Avenue | |
Suite B1305 | |
Monterey Park, CA 91754 | |
United States | |
765-607-3623 |
Facility : # 1 China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
SS-22 | SS-22 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
LT-31 | LT-31 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
LT-32 | LT-32 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
LT-33 | LT-33 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
LT-34 | LT-34 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
SS-21 | SS-21 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
TY-10 | TY-10 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
TY-11 | TY-11 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
TY-12 | TY-12 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WLP-D4 | WLP-D4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WLP-D5 | WLP-D5 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
Paragon Water Systems, Inc. | |
13805 Monroes Business Park | |
Tampa, FL 33635 | |
United States | |
727-538-4704 | |
Visit this company's website |
Facility : Tampa, FL
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
GV MWFGV | MWFGV | 300(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
HDX FMG-1 | FMG-1 | 300(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Power Src, LLC | |
296 Beauvoir Road | |
Suite 100-28 | |
Biloxi, MS 39531 | |
United States | |
228-218-7606 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
PS-DA29-00020B-S | PS-DA29-00020B | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PS-LT700P-S | PS-LT700P | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PS-LT800P-S | PS-LT800P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PS-MWF-S | PS-MWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
PS-UKF8001-S | PS-UKF8001 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Protect Plus LLC | |
11515 Vanstory Drive | |
Suite 110 | |
Huntersville, NC 28078 | |
United States | |
704-584-0704 |
Facility : Zhongshan, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
Brita RF-101[Pb] | N/A | 4000(1) | .5 | Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class V |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Refresh Filters, LLC | |
1460 Broadway | |
New York, NY 10036 | |
United States | |
855-357-8073 | |
929-999-5807 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
R-0003-S | R-0003 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-3600-S | R-3600 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-4396701-S | R-4396701 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-644845-S | R-644845 | 300 | .5 | Taste and Odor Reduction Chlorine Reduction |
||
R-8171413-S | R-8171413 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-9006-S | R-9006 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-9010-S | R-9010 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-9101-S | R-9101 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-9490-S | R-9490 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-9690-S | R-9690 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-9890-S | R-9890 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-9911-S | R-9911 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-9914-S | R-9914 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-9990-S | R-9990 | 300 | .5 | Nominal Particulate Reduction, Class I | ||
R-9991-S | R-9991 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-GXRTDR-S | R-GXRTDR | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
R-MSWF-S | R-MSWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Renew Parts LLC | |
1460 Broadway | |
New York, NY 10036 | |
United States | |
929-207-2582 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[3] |
||||||
0003RNW-S[Pb] | 0003RNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
3600RNW-S[Pb] | 3600RNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
4396701RNW-S[Pb] | 4396701RNW | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
644845RNW-S[Pb] | 644845RNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
8171413RNW-S[Pb] | 8171413RNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
9006RNW-S[Pb] | 9006RNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
9010ARNW-S[Pb] | 9010ARNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
9010BRNW-S[Pb] | 9010BRNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
9101RNW-S[Pb] | 9101RNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
9490RNW-S[Pb] | 9490RNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
9690RNW-S[Pb] | 9690RNW | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
9890RNW-S[Pb] | 9890RNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
9911RNW-S[Pb] | 9911RNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
9914RNW-S[Pb] | 9914RNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
9990RNW-S | 9990RNW | 300 | .5 | Nominal Particulate Reduction, Class I | ||
9991RNW-S[Pb] | 9991RNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
GXRTDRRNW-S[Pb] | GXRTDRRNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
MSWFRNW-S[Pb] | MSWFRNW | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
N/A | ||||||
  [3] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Rojo, LLC | |
172 Center Street | |
Suite 202 | |
P.O. Box 2869 | |
Jackson, WY 83001 | |
United States | |
208-559-0176 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
EBL7700-S | EBL7700 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EBL7770-S | EBL7770 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EBL7771-S | EBL7771 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
EBL7800-S | EBL7800 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Brands Management Corp | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2500 | |
Visit this company's website |
Facility : Gyeongsangnam-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
ADQ74793502 | ADQ74793502 | 200[1] | .5 | Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
  [1] Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Brands Management Corporation | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2500 | |
Visit this company's website |
Facility : Pingtung, Taiwan
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
P8KB2L | 9081 | 200 | .75 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P9KB2L | 9082 | 200 | .75 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Canada Inc. | |
290 Yonge Street | |
Toronto, ON M5B 2C3 | |
Canada | |
800-469-4663 |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Kenmore Ultra | 9919 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Roebuck and Co. | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2198 |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Kenmore NGFC 2000 | FC-100 | 400 | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
Kenmore NGRG 2000 | RG-200 | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class III Taste and Odor Reduction |
||
Kenmore Ultra | 9999 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
Kenmoreclear! | 9999 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
Kenmorepure! | 9911 | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sem Trading Company, Inc. | |
1942 Broadway Street | |
Suite 314C | |
Boulder, CO 80302 | |
United States | |
86 136 1301 4489 |
Facility : # 1 China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
DK-00003G | DK-00003G | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DK-00020B | DK-00020B | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DK-500P | DK-500P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DK-600P | DK-600P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DK-8001 | DK-8001 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DK-800P | DK-800P | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DK-9085 | DK-9085 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DK-9690 | DK-9690 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DK-GSWF | DK-GSWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DK-MWF | DK-MWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
DK-RPWF | DK-RPWF | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
Shenzhen Jiechuang Design Co., Ltd. | |
F-2, 8F, Building 3,Tingwei Ind. Park | |
No. 6 Liufang Road, Bao'an District | |
518101 | |
China | |
86 133 9241 7214 |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
FTAS050-S | FTAS050 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FTAS060-S | FTAS060 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FTAS070-S | FTAS070 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FTAS090-S | FTAS090 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FTAS100-S | FTAS100 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FTAS110-S | FTAS110 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FTAS130-S | FTAS130 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
FTAS140-S | FTAS140 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
IRHS050-S | IRHS050 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
IRHS060-S | IRHS060 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
IRHS070-S | IRHS070 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
IRHS090-S | IRHS090 | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
IRHS100-S | IRHS100 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
IRHS110-S | IRHS110 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
IRHS130-S | IRHS130 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
IRHS140-S | IRHS140 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
TOP PURE (USA), Inc. | |
3717 San Gabriel River Parkway | |
Pico Rivera, CA 90660 | |
United States | |
1 6262389070 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
RWF0100A-S | RWF0100A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0300A-S | RWF0300A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0400A-S | RWF0400A | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0500A-S | RWF0500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0600A-S | RWF0600A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0700A-S | RWF0700A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0900A-S | RWF0900A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1100A-S | RWF1100A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1200A-S | RWF1200A | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1300A-S | RWF1300A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1400A-S | RWF1400A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1500A-S | RWF1500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF2000A-S | RWF2000A | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF2900A-S | RWF2900A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3000A-S | RWF3000A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3100A-S | RWF3100A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3300A-S | RWF3300A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3400A-S | RWF3400A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3500A-S | RWF3500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3600A-S | RWF3600A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWFS0100AH | RWF0100AH | 300 | .42 | Nominal Particulate Reduction, Class I | ||
RWFS0500AH | RWF0500AH | 300 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS0600AH | RWF0600AH | 300 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS0700AH | RWF0700AH | 300 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS0900AH | RWF0900AH | 300 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS1000AH | RWF1000AH | 300 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS1100AH | RWF1100AH | 300 | .35 | Nominal Particulate Reduction, Class I | ||
RWFS1200AH | RWF1200AH | 200 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS3300AH | RWF3300AH | 300 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS3500AH | RWF3500AH | 200 | .41 | Nominal Particulate Reduction, Class I | ||
WFC2500A-S | WFC2500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC2600A-S | WFC2600A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC2800A-S | WFC2800A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Tozone National Inc. | |
9720 Coit Road | |
Suite 220, #307 | |
Plano, TX 75025 | |
United States | |
1 469 740 0568 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] [Pb] |
||||||
RWF0100A-S | RWF0100A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0300A-S | RWF0300A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0400A-S | RWF0400A | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0500A-S | RWF0500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0600A-S | RWF0600A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0700A-S | RWF0700A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0900A-S | RWF0900A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1100A-S | RWF1100A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1200A-S | RWF1200A | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1300A-S | RWF1300A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1400A-S | RWF1400A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1500A-S | RWF1500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF2000A-S | RWF2000A | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF2900A-S | RWF2900A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3000A-S | RWF3000A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3100A-S | RWF3100A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3300A-S | RWF3300A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3400A-S | RWF3400A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3500A-S | RWF3500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3600A-S | RWF3600A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC2500A-S | WFC2500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC2600A-S | WFC2600A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC2800A-S | WFC2800A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [1] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Viking Range, LLC | |
111 Front Street | |
Greenwood, MS 38930 | |
United States | |
1-888-845-4641 | |
Visit this company's website |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
TruWater NGFC 2000 | RWFVRF | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
Prochill NGPT[Pb] | RWFVRF1 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
TruWater NGFC[Pb] | RWFVRF | 400(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Water Channel Partners | |
1890 Woodlane Drive | |
Woodbury, MN 55125 | |
United States | |
800-869-2837 |
Facility : # 3 USA
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
Ecopure EPINL20 | N/A | 1350 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
North Star NSIF100 | N/A | 1350 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Watts Regulator Company | |
815 Chestnut Street | |
North Andover, MA 01845 | |
United States | |
978-689-1811 | |
Visit this company's website |
Facility : # 1 USA
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
A-1 | A-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
G-1 | G-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
G-2 | G-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
G-3 | G-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
G-4 | G-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
L-1 | L-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
L-2 | L-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
L-3 | L-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
L-4 | L-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
M-1 | M-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
M-2 | M-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
S-1 | S-1 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
S-2 | S-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
W-2 | W-2 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
W-3 | W-3 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
W-4 | W-4 | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
W-5 | W-5 | 400 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Whirlpool Corporation | |
2000 North M-63 | |
Benton Harbor, MI 49085 | |
United States | |
269-923-7688 |
Facility : # 1 Taiwan
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
9083[2] [Pb] | 9083 | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
9085[2] [Pb] | 9085 | 240(1) | 0.5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
EDR1RXD1B [2] [Pb] | EDR1RXD1B | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
EDR2RXD1B[2] [Pb] | EDR2RXD1B | 200(1) | .6 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
EDR3RXD1B[2] [Pb] | EDR3RXD1B | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
EDR5RXD1B [2] [Pb] | EDR5RXD1B | 240(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
EVFILTER5[2] [Pb] | EVFILTER5 | 240 | .5 | Chlorine Reduction | ||
EVFILTER5B[2] [Pb] | EVFILTER5B | 240 | .5 | Chlorine Reduction | ||
FILTER1B[2] [Pb] | FILTER1B | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
FILTER2B[2] [Pb] | FILTER2B | 200(1) | .6 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
FILTER3B[2] [Pb] | FILTER3B | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
FILTER5B[2] [Pb] | FILTER5B | 240(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P1WB2[2] [Pb] | EDR3RXD1 | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P1WB2[2] [Pb] | KAD3RXD1[7] | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P1WB2[2] [Pb] | WHR3RXD1[8] | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P1WB2L[2] [Pb] | EDR3RXD1 | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P1WB2L[2] [Pb] | KAD3RXD1[7] | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P1WB2L[2] [Pb] | WHR3RXD1[8] | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P8WB2L[2] [Pb] | EDR1RXD1 | 200 | .50 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P8WB2L[2] [Pb] | KAD1RXD1[7] | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P8WB2L[2] [Pb] | WHR1RXD1[8] | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P9WB2L[2] [Pb] | WHR2RXD1[8] | 200(1) | .6 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P9WB2L[2] [Pb] | EDR2RXD1 | 200 | .60 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
P9WB2L[2] [Pb] | KAD2RXD1[7] | 200(1) | .6 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PWF-NL240V[2] [Pb] | EDR5RXD1 | 240(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] Product is authorized to bear the NSF and/or the cNSFus Mark. [7] KitchenAid® [8] Whirlpool® [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
YUNDA H&H TECH (Tianjin) Co., Ltd. | |
No.29, Jinhai Road | |
Jinghai, Tianjin 301600 | |
China | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[2] |
||||||
RFS3902[Pb] | 7440 011 | 300 | 47 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
RWF0100A-S[Pb] | RWF0100A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0300A-S[Pb] | RWF0300A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0400A-S[Pb] | RWF0400A | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0500A-S[Pb] | RWF0500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0600A-S[Pb] | RWF0600A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0700A-S[Pb] | RWF0700A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF0900A-S[Pb] | RWF0900A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1100A-S[Pb] | RWF1100A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1200A-S[Pb] | RWF1200A | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1300A-S[Pb] | RWF1300A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1400A-S[Pb] | RWF1400A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF1500A-S[Pb] | RWF1500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF2000A-S[Pb] | RWF2000A | 200 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF2900A-S[Pb] | RWF2900A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3000A-S[Pb] | RWF3000A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3100A-S[Pb] | RWF3100A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3300AB-S[Pb] | RWF3300AB | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3400A-S[Pb] | RWF3400A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3500A-S[Pb] | RWF3500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWF3600A-S[Pb] | RWF3600A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
RWFS0100AH | RWF0100AH | 300 | .42 | Nominal Particulate Reduction, Class I | ||
RWFS0500AH | RWF0500AH | 300 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS0600AH | RWF0600AH | 300 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS0700AH | RWF0700AH | 300 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS0900AH | RWF0900AH | 300 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS1000AH | RWF1000AH | 300 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS1100AH | RWF1100AH | 300 | .35 | Nominal Particulate Reduction, Class I | ||
RWFS1200AH | RWF1200AH | 200 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS3000AH | RWF3000AH | 300 | .47 | Nominal Particulate Reduction, Class I | ||
RWFS3300ABH | RWF3300ABH | 300 | .5 | Nominal Particulate Reduction, Class I | ||
RWFS3500AH | RWF3500AH | 200 | .41 | Nominal Particulate Reduction, Class I | ||
RWFS3600AH | RWF3600AH | 200 | .3 | Nominal Particulate Reduction, Class I | ||
WFC2500A-S[Pb] | WFC2500A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC2600A-S[Pb] | WFC2600A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
WFC2800A-S[Pb] | WFC2800A | 300 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
  [2] Products comply with the material safety and structural integrity requirements of NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
NSF/ANSI 53
Drinking Water Treatment Units - Health Effects
Drinking Water Treatment Units - Health Effects
A.O. Smith Corporation | |
11270 West Park Place | |
Milwaukee, WI 53224 | |
United States | |
800-527-1953 |
Facility : Haltom City, TX
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
AO-FF | AO-US-100-R | 200 | .5(1) | Asbestos Reduction Cyst Reduction Lead Reduction MTBE Reduction Mercury Reduction Turbidity Reduction VOC Reduction ** PFOA Reduction PFOS Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
AGA IMPORTS LLC | |
70 Canary Drive | |
Lakewood, NJ 08701 | |
United States | |
917-533-0138 |
Facility : # 3 China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] |
||||||
GVF033-S | GVF033 | 200 | .3 | Cyst Reduction Lead Reduction Mercury Reduction |
||
GVF035-S | GVF035 | 300 | .47 | Cyst Reduction Lead Reduction Mercury Reduction |
||
GVF041-S | GVF041 | 200 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
GVF042-S | GVF042 | 200 | .41 | Cyst Reduction Lead Reduction Mercury Reduction |
||
  [1] Claims of capacity or rated service cycle are not applicable for mechanical filtration. |
Altwell Tech Inc. | |
42-24, Daehwa-ro 150 beon-gil | |
Daedeok-gu, Daejeon | |
Korea, Republic of | |
888-637-3338 | |
213-637-5800 |
Facility : Daejeon, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
DA97-08006A-E[Pb] | DA29-00020B | 300(1) | .5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Chlorobenzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction 1,2,4-Trichlorobenzene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Aquamor, LLC | ![]() |
42188 Rio Nedo | |
Temecula, CA 92590 | |
United States | |
866-218-8473 | |
951-541-9517 | |
Visit this company's website |
Facility : Temecula, CA
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
AQB-1 | AQB-1 | 300 | .5 | 1,2,4-Trichlorobenzene Reduction Endrin Reduction P-Dichlorobenzene Reduction |
||
EarthSmart A-1 | A-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart G-1 | G-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart G-2 | G-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart G-3 | G-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart G-4 | G-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart G-6 | G-6 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart G-7 | G-7 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart H-1 | H-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart L-1 | L-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart L-2 | L-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart L-3 | L-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart L-4 | L-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart L-5 | L-5 | 300 | .5 | 1,2,4-Trichlorobenzene Reduction Endrin Reduction P-Dichlorobenzene Reduction |
||
EarthSmart M-1 | M-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart M-2 | M-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart S-1 | S-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart S-2 | S-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart S-4 | S-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart W-1 | W-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart W-2 | W-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart W-3 | W-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
EarthSmart W-4 | W-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FMA-1 | FMA-1 | 300 | .5 | Benzene Reduction Carbofuran Reduction Endrin Reduction P-Dichlorobenzene Reduction Toxaphene Reduction |
||
HDX FMF-8 | FMF-8 | 300 | .5 | 1,2,4-Trichlorobenzene Reduction Endrin Reduction P-Dichlorobenzene Reduction |
||
HDX FMG-1 | FMG-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FMG-2 | FMG-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FMG-3 | FMG-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FML-1 | FML-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FML-2 | FML-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FML-3 | FML-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FML-4 | FML-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FML-5 | HDX FML-5 | 300 | .5 | 1,2,4-Trichlorobenzene Reduction Endrin Reduction P-Dichlorobenzene Reduction |
||
HDX FMM-1 | FMM-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FMM-2 | FMM-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FMS-1 | FMS-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FMS-2 | FMS-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FMS-4 | HDX FMS-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FMW-2 | FMW-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FMW-3 | FMW-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
HDX FMW-4 | FMW-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source A-1 | A-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source A-1-2 | A-1-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source F-8 | F-8 | 300 | .5 | 1,2,4-Trichlorobenzene Reduction Endrin Reduction P-Dichlorobenzene Reduction |
||
Project Source G-1 | G-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction |
||
Project Source G-1-2 | G-1-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source G-2 | G-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source G-2-2 | G-2-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source G-3 | G-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source G-3-2 | G-3-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source G-4 | G-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source G-4-2 | G-4-2 | 300 | .5 | 1,2,4-Trichlorobenzene Reduction Endrin Reduction P-Dichlorobenzene Reduction |
||
Project Source H-1 | H-1 | 300 | .5 | 1,2,4-Trichlorobenzene Reduction Endrin Reduction P-Dichlorobenzene Reduction |
||
Project Source H-1-2 | H-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source L-1 | L-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source L-1-2 | L-1-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source L-2 | L-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source L-2-2 | L-2-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source L-3 | L-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source L-3-2 | L-3-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source L-4 | L-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source L-4-2 | L-4-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source L-5 | L-5 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source L-5-2 | L-5-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source M-1 | M-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source M-1-2 | M-1-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source M-2 | M-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source M-2-2 | M-2-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source S-1 | S-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source S-1-2 | S-1-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source S-2 | S-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source S-2-2 | S-2-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source S-4 | S-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source S-4-2 | S-4-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source W-1 | W-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source W-1-2 | W-1-2 | 300 | .5 | 1,2,4-Trichlorobenzene Reduction Endrin Reduction P-Dichlorobenzene Reduction |
||
Project Source W-2 | W-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source W-2-2 | W-2-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source W-4 | W-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Project Source W-4-2 | W-4-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-A1 | SW-A1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-G1 | SW-G1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-G2 | SW-G2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-G3 | SW-G3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-G4 | SW-G4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-G6 | SW-G6 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-G7 | SW-G7 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-H1 | SW-H1 | 300 | .5 | 1,2,4-Trichlorobenzene Reduction Endrin Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-H1 | SW-H1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-L1 | SW-L1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-L2 | SW-L2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-L3 | SW-L3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-L4 | SW-L4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-L5 | SW-L5 | 300 | .5 | 1,2,4-Trichlorobenzene Reduction Endrin Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-M1 | SW-M1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-M2 | SW-M2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-S1 | SW-S1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-S2 | SW-S2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-S4 | SW-S4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-W1 | SW-W1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-W2 | SW-W2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-W3 | SW-W3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
SafeWater SW-W4 | SW-W4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Electrolux Home Products | |
10200 David Taylor Drive | |
Charlotte, NC 28262 | |
United States | |
877-435-3287 | |
980-236-2000 | |
Visit this company's website |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Prochill NGPT[2] | RWFVRF1 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction VOC Reduction ** Atrazine Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
Pure Advantage NGFC-2000 | FC-100 FC-300 |
400(1) | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Lindane Reduction |
||
PureAdvantage NGFC-2000 | EWF2CBPA | 400(1) | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Lindane Reduction |
||
PureAdvantage PWF-1[5] | EPPWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureAdvantage PWF-1-U[6] | EPPWFU01 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction |
||
PureAdvantage Ultra[3] | EWF02 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction VOC Reduction ** Atrazine Reduction |
||
PureAdvantage Ultra-U[4] | EWF02 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction Atrazine Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction Asbestos Reduction |
||
PureSource 2 NGFC-2000 | FC-100 | 400(1) | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
PureSource 3 | WF3CB | 200(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
PureSource Ultra | ULTRAWF | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction MTBE Reduction VOC Reduction ** |
||
PureSource Ultra II[7] | EPTWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction VOC Reduction ** Atrazine Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
PureSource Ultra II-U[8] | EPTWFU01 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction Atrazine Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
pure advantage ™ NGFC-2000 | WF2CB | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction Asbestos Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] ProChill NGPT with Performance Indicator Device. [3] PureAdvantage Ultra with Performance Indicator Device. [4] PureAdvantage Ultra-U without Performance Indicator Device. [5] PureAdvantage PWF-1 with Performance Indicator Device. [6] PureAdvantage PWF-1-U without Performance Indicator Device. [7] PureSource Ultra II with Performance Indicator Device. [8] PureSource Ultra II-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Singapore, Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Prochill NGPT[2] | RWFVRF1 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction VOC Reduction ** Atrazine Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
PureAdvantage NGFC-2000 | EWF2CBPA | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Asbestos Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Asbestos Reduction |
||
PureAdvantage PWF-1[5] | EPPWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureAdvantage PWF-1-U[6] | EPPWFU01 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureAdvantage Ultra[3] | EWF02 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction VOC Reduction ** Atrazine Reduction |
||
PureAdvantage Ultra-U[4] | EWF02 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction Atrazine Reduction |
||
PureSource 2 NGFC-2000 | FC-100 | 400(1) | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Asbestos Reduction |
||
PureSource 3 | WF3CB | 200 | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
PureSource Ultra | ULTRAWF | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction MTBE Reduction VOC Reduction ** |
||
PureSource Ultra II[7] | EPTWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction VOC Reduction ** Atrazine Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
PureSource Ultra II-U[8] | EPTWFU01 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction Atrazine Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
pure advantage ™ NGFC-2000 | WF2CB | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Asbestos Reduction |
||
pure advantage™ NGFC-2000 | FC-100 FC-300 |
400(1) | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] ProChill NGPT with Performance Indicator Device. [3] PureAdvantage Ultra with Performance Indicator Device. [4] PureAdvantage Ultra-U without Performance Indicator Device. [5] PureAdvantage PWF-1 with Performance Indicator Device. [6] PureAdvantage PWF-1-U without Performance Indicator Device. [7] PureSource Ultra II with Performance Indicator Device. [8] PureSource Ultra II-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Foshan Micro Midea Filter Mfg. Co., Ltd. | |
B Area Cherry Blossom Park | |
No. 19 Lingang Road, Bejiao Town Shunde | |
Foshan, Guangdong 528311 | |
China | |
86 135 9090 8470 |
Facility : Foshan, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
M-SJWF200 | SJWF200 | 200(1) | .5 | Cyst Reduction Lead Reduction |
||
MF-2008-R2 | MF-2008-R2R NS-WF26SS0-1 MIWF6200 MIWFT2100 |
200(1) | .5 | Cyst Reduction Lead Reduction |
||
MF-2008-TG | WF200 | 200(1) | .5 | Cyst Reduction Lead Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. |
Frigidaire Home Products | |
10200 David Taylor Drive | |
Charlotte, NC 28262 | |
United States | |
1-800-559-7569 | |
980-236-2000 |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Frigidaire PureSource 3 | WF3CB | 200(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
Frigidaire PureSource Ultra | ULTRAWF | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction MTBE Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction Turbidity Reduction |
||
PurePour PWF-1 | EPPWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction Trichloroethylene Reduction |
||
PurePour WF-1[2] | FPPWFU01 | 125 | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PurePour WF-1-U[3] | FPPWFU01 | 200 | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction Asbestos Reduction Benzene Reduction Carbofuran Reduction Endrin Reduction Ethylbenzene Reduction P-Dichlorobenzene Reduction |
||
PureSource Ultra II | EPTWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PurePourWF-1 with Performance Indicator Device. [3] PurePour WF-1-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Frigidaire PureSource 3 | WF3CB | 200(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
Frigidaire PureSource Ultra | ULTRAWF | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction MTBE Reduction VOC Reduction ** |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Asbestos Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
PurePour PWF-1 | EPPWFU01 | 125(1) | .65 | 2,4-D Reduction Atrazine Reduction Asbestos Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction VOC Reduction ** Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Trichloroethylene Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
PurePour PWF-1[2] | FPPWFU01 | 125 | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction Tetrachloroethylene Reduction P-Dichlorobenzene Reduction |
||
PurePour WF-1-U[3] | FPPWFU01 | 200 | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | 0.5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Asbestos Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
PureSource Ultra II | EPTWFU01 | 125(1) | .65 | 2,4-D Reduction Atrazine Reduction Asbestos Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction VOC Reduction ** Tetrachloroethylene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PurePour WF-1 with Performance Indicator Device. [3] PurePour WF-1-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Instapure Brands, Inc. | |
P.O. Box 271850 | |
Fort Collins, CO 80527 | |
United States | |
970-212-4100 |
Facility : # 1 USA
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
REF-IPA-1 | REF-IPA-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPG-1 | REF-IPG-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPG-2 | REF-IPG-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPG-3 | REF-IPG-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPG-4 | REF-IPG-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPL-1 | REF-IPL-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPL-2 | REF-IPL-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPL-3 | REF-IPL-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPL-4 | REF-IPL-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPL-5 | REF-IPL-5 | 300 | .5 | 1,2,4-Trichlorobenzene Reduction Endrin Reduction P-Dichlorobenzene Reduction |
||
REF-IPM-1 | REF-IPM-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPM-2 | REF-IPM-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPS-1 | REF-IPS-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPS-2 | REF-IPS-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPW-2 | REF-IPW-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPW-3 | REF-IPW-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
REF-IPW-4 | REF-IPW-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
JFL Distributors Inc. / Pure Green Water Filters | |
1251 42nd Street Brooklyn | |
New York, NY 11219 | |
United States | |
800-659-6658 | |
347-534-4955 | |
Visit this company's website |
Facility : Guangdong, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
PG-4396508A | PG-4396508A | 300 | .31 | Lead Reduction | ||
PG-700PA | PG-700PA | 200 | .31 | Lead Reduction | ||
PG-8001A | PG-8001A | 300 | .31 | Lead Reduction | ||
PG-DA20A | PG-DA20A | 300 | .31 | Lead Reduction | ||
PG-MWFA | PG-MWFA | 300 | .31 | Lead Reduction |
LG Electronics Inc. | |
170,Seongsanpaechong-ro | |
Seongsan-gu, Changwon-si | |
Gyeongsangnam-do, 642-711 | |
Korea, Republic of | |
82 55 268 4622 | |
Visit this company's website |
Facility : Gyeongsangnam-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
MDJ64844601 | LT1000P LT1000PC LT1000PCS |
200(1) | 0.5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Microfilter Co., Ltd. | ![]() |
15-1, Gwinong 3-gil, Deoksan-eup | |
(162-1 Sansuri, Deoksan-eup) | |
Jincheon-gun, Chungcheongbuk-do | |
27856, | |
Korea, Republic of | |
82 43 536 5221 | |
Visit this company's website |
Facility : # 1 Chungcheongbuk-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
DA97-08006A-1[Pb] | DA29-00020B-1 DA29-00020B |
300 | .5 | Asbestos Reduction Benzene Reduction Atrazine Reduction 2,4-D Reduction Carbofuran Reduction Chlorobenzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
DA97-08006A-2[Pb] | DA29-00020B-1 DA29-00020B |
300 | .5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Chlorobenzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Chungcheongbuk-Do, Korea, Republic of
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
8001036935 | 8001045102 | 250(1) | .55 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Ethylbenzene Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
DA97-08006A-1[Pb] | DA29-00020B DA29-00020B-1 |
300(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Ethylbenzene Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction 2,4-D Reduction Chlorobenzene Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
DA97-08006A-2[Pb] | DA29-00020B DA29-00020B-1 |
300(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Ethylbenzene Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction 2,4-D Reduction Chlorobenzene Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Paragon Water Systems, Inc. | |
13805 Monroes Business Park | |
Tampa, FL 33635 | |
United States | |
727-538-4704 | |
Visit this company's website |
Facility : Tampa, FL
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
GV MWFGV | MWFGV | 300(1) | .5 | Lead Reduction | ||
HDX FMG-1 | FMG-1 | 300(1) | .5 | Lead Reduction | ||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Brands Management Corp | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2500 | |
Visit this company's website |
Facility : Gyeongsangnam-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
ADQ74793502 | ADQ74793502 | 200[1] | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Lindane Reduction P-Dichlorobenzene Reduction 2,4-D Reduction Lead Reduction Mercury Reduction Cyst Reduction |
||
  [1] Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Brands Management Corporation | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2500 | |
Visit this company's website |
Facility : Pingtung, Taiwan
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
P8KB2L | 9081 | 200 | .75 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
P9KB2L | 9082 | 200 | .75 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Canada Inc. | |
290 Yonge Street | |
Toronto, ON M5B 2C3 | |
Canada | |
800-469-4663 |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Kenmore Ultra | 9919 | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Sears Roebuck and Co. | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2198 |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Kenmore NGFC 2000 | FC-100 | 400 | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Kenmoreclear! | 9999 | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** MTBE Reduction |
||
Kenmorepure! | 9911 | 400(1) | .5 | Alachlor Reduction Atrazine Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction 2,4-D Reduction |
||
Kenmore Ultra | 9999 | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** MTBE Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Sem Trading Company, Inc. | |
1942 Broadway Street | |
Suite 314C | |
Boulder, CO 80302 | |
United States | |
86 136 1301 4489 |
Facility : # 1 China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
DK-00003G | DK-00003G | 300 | .5 | Lead Reduction | ||
DK-00020B | DK-00020B | 300 | .5 | Lead Reduction | ||
DK-500P | DK-500P | 300 | .5 | Lead Reduction | ||
DK-600P | DK-600P | 300 | .5 | Lead Reduction | ||
DK-8001 | DK-8001 | 300 | .5 | Lead Reduction | ||
DK-9085 | DK-9085 | 300 | .5 | Lead Reduction | ||
DK-9690 | DK-9690 | 200 | .5 | Lead Reduction | ||
DK-GSWF | DK-GSWF | 300 | .5 | Lead Reduction | ||
DK-MWF | DK-MWF | 300 | .5 | Lead Reduction | ||
DK-RPWF | DK-RPWF | 300 | .5 | Lead Reduction |
TOP PURE (USA), Inc. | |
3717 San Gabriel River Parkway | |
Pico Rivera, CA 90660 | |
United States | |
1 6262389070 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
RWFS0100AH | RWF0100AH | 300(1) | .42 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0500AH | RWF0500AH | 300(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0600AH | RWF0600AH | 300(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0700AH | RWF0700AH | 300(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0900AH | RWF0900AH | 300(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS1000AH | RWF1000AH | 300(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS1100AH | RWF1100AH | 300(1) | .35 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS1200AH | RWF1200AH | 200(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS3300AH | RWF3300AH | 300(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS3500AH | RWF3500AH | 200(1) | .41 | Cyst Reduction Lead Reduction Mercury Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. |
Viking Range, LLC | |
111 Front Street | |
Greenwood, MS 38930 | |
United States | |
1-888-845-4641 | |
Visit this company's website |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
TruWater NGFC 2000 | RWFVRF | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Ethylbenzene Reduction Endrin Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
Prochill NGPT[Pb] | RWFVRF1 | 125(1) | .65 | 2,4-D Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
TruWater NGFC[Pb] | RWFVRF | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Watts Regulator Company | |
815 Chestnut Street | |
North Andover, MA 01845 | |
United States | |
978-689-1811 | |
Visit this company's website |
Facility : # 1 USA
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
A-1 | A-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
G-1 | G-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
G-2 | G-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
G-3 | G-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
G-4 | G-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
L-1 | L-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
L-2 | L-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
L-3 | L-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
L-4 | L-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
M-1 | M-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
M-2 | M-2 | 300 | .5 | Endrin Reduction P-Dichlorobenzene Reduction 1,2,4-Trichlorobenzene Reduction |
||
S-1 | S-1 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
S-2 | S-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
W-2 | W-2 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
W-3 | W-3 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
W-4 | W-4 | 300 | .5 | Endrin Reduction 1,2,4-Trichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
W-5 | W-5 | 400 | .5 | Benzene Reduction Carbofuran Reduction Endrin Reduction P-Dichlorobenzene Reduction Toxaphene Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Whirlpool Corporation | |
2000 North M-63 | |
Benton Harbor, MI 49085 | |
United States | |
269-923-7688 |
Facility : # 1 Taiwan
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
9083[4] [Pb] | 9083 | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
9085[4] [Pb] | 9085 | 240(1) | 0.5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
EDR1RXD1B[4] [Pb] | EDR1RXD1B | 200(1) | .5 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
EDR2RXD1B[4] [Pb] | EDR2RXD1B | 200(1) | .6 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
EDR3RXD1B[4] [Pb] | EDR3RXD1B | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
EDR5RXD1B[4] [Pb] | EDR5RXD1B | 240(1) | .5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
EVFILTER5[4] [Pb] | EVFILTER5 | 240 | .5 | Lead Reduction | ||
EVFILTER5B[4] [Pb] | EVFILTER5B | 240 | .5 | Lead Reduction | ||
FILTER1B[4] [Pb] | FILTER1B | 200(1) | .5 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
FILTER2B[4] [Pb] | FILTER2B | 200(1) | .6 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
FILTER3B[4] [Pb] | FILTER3B | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
FILTER5B[4] [Pb] | FILTER5B | 240(1) | .5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
P1WB2[4] [Pb] | KAD3RXD1[5] | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
P1WB2[4] [Pb] | WHR3RXD1[6] | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
P1WB2[4] [Pb] | EDR3RXD1 | 200(1) | .5 | Asbestos Reduction MTBE Reduction Trihalomethanes (TTHM) Reduction Carbofuran Reduction VOC Reduction ** Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
P1WB2L[4] [Pb] | EDR3RXD1 | 200(1) | .5 | Asbestos Reduction MTBE Reduction Trihalomethanes (TTHM) Reduction Carbofuran Reduction VOC Reduction ** Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
P1WB2L[4] [Pb] | KADR3RXD1[5] | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
P1WB2L[4] [Pb] | WHR3RXD1[6] | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
P8WB2L[4] [Pb] | WHR1RXD1[6] | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
P8WB2L[4] [Pb] | EDR1RXD1 | 200 | .50 | O-Dichlorobenzene Reduction Endrin Reduction Ethylbenzene Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Lead Reduction Toxaphene Reduction Turbidity Reduction P-Dichlorobenzene Reduction Lindane Reduction Tetrachloroethylene Reduction Toluene Reduction Styrene Reduction 1,2,4-Trichlorobenzene Reduction |
||
P8WB2L[4] [Pb] | KAD1RXD1[5] | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
P9WB2L[4] [Pb] | WHR2RXD1[6] | 200(1) | .6 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
P9WB2L[4] [Pb] | EDR2RXD1 | 200 | .60 | O-Dichlorobenzene Reduction Endrin Reduction Ethylbenzene Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Lead Reduction Toxaphene Reduction Turbidity Reduction P-Dichlorobenzene Reduction Lindane Reduction Tetrachloroethylene Reduction Toluene Reduction Styrene Reduction 1,2,4-Trichlorobenzene Reduction |
||
P9WB2L[4] [Pb] | KAD2RXD1[5] | 200(1) | .6 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
PWF-NL240V[4] [Pb] | EDR5RXD1 | 240(1) | .5 | Benzene Reduction Carbofuran Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction 2,4-D Reduction Atrazine Reduction Cyst Reduction Asbestos Reduction Turbidity Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [4] Product is authorized to bear the NSF and/or the cNSFus Mark. [5] KitchenAid® [6] Whirlpool® [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
YUNDA H&H TECH (Tianjin) Co., Ltd. | |
No.29, Jinhai Road | |
Jinghai, Tianjin 301600 | |
China | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] |
||||||
RFS3902[Pb] | 7440 011 | 300 | .47 | Cyst Reduction Lead Reduction |
||
RWFS0100AH | RWF0100AH | 300 | .42 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0500AH | RWF0500AH | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0600AH | RWF0600AH | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0700AH | RWF0700AH | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0900AH | RWF0900AH | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS1000AH | RWF1000AH | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS1100AH | RWF1100AH | 300 | .35 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS1200AH | RWF1200AH | 200 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS3000AH | RWF3000AH | 300 | .47 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS3300ABH | RWF3300ABH | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS3500AH | RWF3500AH | 200 | .41 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS3600AH | RWF3600AH | 200 | .3 | Cyst Reduction Lead Reduction Mercury Reduction |
||
  [1] Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
NSF/ANSI 401
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants
A.O. Smith Corporation | |
11270 West Park Place | |
Milwaukee, WI 53224 | |
United States | |
800-527-1953 |
Facility : Haltom City, TX
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
AO-FF | AO-US-100-R | 200 | .5(1) | Meprobamate Reduction Atenolol Reduction Carbamazepine Reduction DEET Reduction Metolachlor Reduction Trimethoprim Reduction Linuron Reduction TCEP Reduction TCPP Reduction Bisphenol A Reduction Estrone Reduction Ibuprofen Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Altwell Tech Inc. | |
42-24, Daehwa-ro 150 beon-gil | |
Daedeok-gu, Daejeon | |
Korea, Republic of | |
888-637-3338 | |
213-637-5800 |
Facility : Daejeon, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
DA97-08006A-E | DA29-00020B | 300(1) | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Meprobamate Reduction Metolachlor Reduction Microplastics Reduction Naproxen Reduction TCEP Reduction TCPP Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Electrolux Home Products | |
10200 David Taylor Drive | |
Charlotte, NC 28262 | |
United States | |
877-435-3287 | |
980-236-2000 | |
Visit this company's website |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Prochill NGPT[2] | RWFVRF1 | 125(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PureAdvantage NGFC-2000 | EWF2CBPA | 400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
PureAdvantage PWF-1[5] | EPPWFU01 | 125(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PureAdvantage PWF-1-U[6] | EPPWFU01 | 200(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PureAdvantage Ultra[3] | EWF02 | 125(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PureAdvantage Ultra-U[4] | EWF02 | 200(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
PureSource 2 NGFC-2000 | FC-100 | 400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction |
||
PureSource 3 | WF3CB | 200(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
PureSource Ultra | ULTRAWF | 200(1) | .65 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
PureSource Ultra II[7] | EPTWFU01 | 125(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PureSource Ultra II-U[8] | EPTWFU01 | 200(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
pure advantage ™ NGFC-2000 | WF2CB | 400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
pure advantage™ NGFC-2000 | FC-100 FC-300 |
400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] ProChill NGPT with Performance Indicator Device. [3] PureAdvantage Ultra with Performance Indicator Device. [4] PureAdvantage Ultra-U without Performance Indicator Device. [5] PureAdvantage PWF-1 with Performance Indicator Device. [6] PureAdvantage PWF-1-U without Performance Indicator Device. [7] PureSource Ultra II with Performance Indicator Device. [8] PureSource Ultra II-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Singapore, Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Prochill NGPT[2] | RWFVRF1 | 125(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PureAdvantage NGFC-2000 | EWF2CBPA | 400 | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400 | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
PureAdvantage PWF-1[5] | EPPWFU01 | 125(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PureAdvantage PWF-1-U[6] | EPPWFU01 | 200(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PureAdvantage Ultra[3] | EWF02 | 125(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PureAdvantage Ultra-U[4] | EWF02 | 200(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
PureSource 2 NGRC-2000 | FC-100 | 400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction |
||
PureSource 3 | WF3CB | 200 | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
PureSource Ultra | ULTRAWF | 400(1) | .65 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
PureSource Ultra II[7] | EPTWFU01 | 125(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PureSource Ultra II-U[8] | EPTWFU01 | 200(1) | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction |
||
pure advantage ™ NGFC-2000 | WF2CB | 400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
pure advantage ™ NGFC-2000 | FC-100 FC-300 |
400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] ProChill NGPT with Performance Indicator Device. [3] PureAdvantage Ultra with Performance Indicator Device. [4] PureAdvantage Ultra-U without Performance Indicator Device. [5] PureAdvantage PWF-1 with Performance Indicator Device. [6] PureAdvantage PWF-1-U without Performance Indicator Device. [7] PureSource Ultra II with Performance Indicator Device. [8] PureSource Ultra II-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Frigidaire Home Products | |
10200 David Taylor Drive | |
Charlotte, NC 28262 | |
United States | |
1-800-559-7569 | |
980-236-2000 |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Frigidaire PureSource 3 | WF3CB | 200(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction |
||
Frigidaire PureSource Ultra | ULTRAWF | 200(1) | .65 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400 | .5 | Atenolol Reduction Trimethoprim Reduction Ibuprofen Reduction |
||
PurePour PWF-1 | FPPWFU01 | 125 | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PurePour WF-1[2] | FPPWFU01 | 125 | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction |
||
PurePour WF-1-U[3] | FPPWFU01 | 200 | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction |
||
PureSource Ultra II | EPTWFU01 | 125 | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PurePour WF-1 with Performance Indicator Device. [3] PurePour WF-1-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Frigidaire PureSource 3 | WF3CB | 200(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
Frigidaire PureSource Ultra | ULTRAWF | 200(1) | .65 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400 | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction |
||
PurePour PWF-1 | EPPWFU01 | 125 | .65 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction |
||
PurePour PWF-1[2] | FPPWFU01 | 125 | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
PurePour WF-1-U[3] | FPPWFU01 | 200 | .65 | Atenolol Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
PureSource Ultra II | EPTWFU01 | 125 | .65 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Microplastics Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PurePourWF-1 with Performance Indicator Device. [3] PurePour WF-1-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
JFL Distributors Inc. / Pure Green Water Filters | |
1251 42nd Street Brooklyn | |
New York, NY 11219 | |
United States | |
800-659-6658 | |
347-534-4955 | |
Visit this company's website |
Facility : Guangdong, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
PG-4396508A | PG-4396508A | 300 | .31 | Estrone Reduction | ||
PG-700PA | PG-700PA | 200 | .31 | Estrone Reduction | ||
PG-8001A | PG-8001A | 300 | .31 | Estrone Reduction | ||
PG-DA20A | PG-DA20A | 300 | .31 | Estrone Reduction | ||
PG-MWFA | PG-MWFA | 300 | .31 | Estrone Reduction |
LG Electronics Inc. | |
170,Seongsanpaechong-ro | |
Seongsan-gu, Changwon-si | |
Gyeongsangnam-do, 642-711 | |
Korea, Republic of | |
82 55 268 4622 | |
Visit this company's website |
Facility : Gyeongsangnam-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
MDJ64844601 | LT1000P LT1000PC LT1000PCS |
200 | 0.5 | Atenolol Reduction Carbamazepine Reduction DEET Reduction Trimethoprim Reduction Linuron Reduction Phenytoin Reduction Ibuprofen Reduction Naproxen Reduction Estrone Reduction Bisphenol A Reduction Microplastics Reduction Nonylphenol Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Microfilter Co., Ltd. | ![]() |
15-1, Gwinong 3-gil, Deoksan-eup | |
(162-1 Sansuri, Deoksan-eup) | |
Jincheon-gun, Chungcheongbuk-do | |
27856, | |
Korea, Republic of | |
82 43 536 5221 | |
Visit this company's website |
Facility : # 1 Chungcheongbuk-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
DA97-08006A-1[Pb] | DA29-00020B-1 DA29-00020B |
300 | .5 | Atenolol Reduction Carbamazepine Reduction DEET Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Trimethoprim Reduction Microplastics Reduction |
||
DA97-08006A-2[Pb] | DA29-00020B-1 DA29-00020B |
300 | .5 | Atenolol Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Trimethoprim Reduction TCEP Reduction TCPP Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Nonylphenol Reduction Ibuprofen Reduction Microplastics Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Chungcheongbuk-Do, Korea, Republic of
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
8001036935 | 8001045102 | 250 | .55 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction |
||
DA97-08006A-1[Pb] | DA29-00020B DA29-00020B-1 |
300 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
DA97-08006A-1[Pb] | DA29-00020B DA29-00020B-1 |
300 | .5 | Atenolol Reduction Carbamazepine Reduction DEET Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Microplastics Reduction Trimethoprim Reduction |
||
DA97-08006A-2[Pb] | DA29-00020B DA29-00020B-1 |
300 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction Ibuprofen Reduction Microplastics Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Brands Management Corp | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2500 | |
Visit this company's website |
Facility : Gyeongsangnam-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
ADQ74793502 | ADQ74793502 | 200 | .5 | Atenolol Reduction Carbamazepine Reduction DEET Reduction Trimethoprim Reduction Linuron Reduction Phenytoin Reduction Ibuprofen Reduction Naproxen Reduction Estrone Reduction Bisphenol A Reduction Nonylphenol Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Brands Management Corporation | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2500 | |
Visit this company's website |
Facility : Pingtung, Taiwan
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
P8KB2L | 9081 | 200 | .75 | Atenolol Reduction Linuron Reduction Trimethoprim Reduction |
||
P9KB2L | 9082 | 200 | .75 | Atenolol Reduction Linuron Reduction Trimethoprim Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Roebuck and Co. | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2198 |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
Kenmoreclear! | 9999 | 200 | .65 | Microplastics Reduction | ||
Kenmorepure! | 9911 | 400 | .5 | Microplastics Reduction | ||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Viking Range, LLC | |
111 Front Street | |
Greenwood, MS 38930 | |
United States | |
1-888-845-4641 | |
Visit this company's website |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
TruWater NGFC 2000 | RWFVRF | 400(1) | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
Prochill NGPT[Pb] | RWFVRF1 | 125 | .65 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Bisphenol A Reduction Estrone Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Microplastics Reduction |
||
TruWater NGFC[Pb] | RWFVRF | 400 | .5 | Atenolol Reduction Ibuprofen Reduction Trimethoprim Reduction Microplastics Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Whirlpool Corporation | |
2000 North M-63 | |
Benton Harbor, MI 49085 | |
United States | |
269-923-7688 |
Facility : # 1 Taiwan
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
9083[1] [Pb] | Filter 3 | 200 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
9085[1] [Pb] | Filter 5 | 240 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
EDR1RXD1B [1] [Pb] | EDR1RXD1B | 200 | .5 | Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction |
||
EDR2RXD1B[1] [Pb] | EDR2RXD1B | 200 | .6 | Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction |
||
EDR3RXD1B[1] [Pb] | EDR3RXD1B | 200 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Nonylphenol Reduction Naproxen Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
EDR5RXD1B[1] [Pb] | EDR5RXD1B | 240 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
FILTER1B[1] [Pb] | FILTER1B | 200 | .5 | Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction |
||
FILTER2B[1] [Pb] | FILTER2B | 200 | .6 | Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction |
||
FILTER3B[1] [Pb] | FILTER3B | 200 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
FILTER5B[1] [Pb] | FILTER5B | 240 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
P1WB2[1] [Pb] | WHR3RXD1[3] | 200 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
P1WB2[1] [Pb] | EDR3RXD1 | 200 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
P1WB2[1] [Pb] | KAD3RXD1[2] | 200 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
P1WB2L[1] [Pb] | KAD3RXD1[2] | 200 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
P1WB2L[1] [Pb] | EDR3RXD1 | 200 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
P1WB2L[1] [Pb] | WHR3RXD1[3] | 200 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
P8WB2L[1] [Pb] | WHR1RXD1[3] | 200 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
P8WB2L[1] [Pb] | EDR1RXD1 | 200 | .50 | Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction |
||
P8WB2L[1] [Pb] | KAD1RXD1[2] | 200 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
P9WB2L[1] [Pb] | WHR2RXD1[3] | 200 | .6 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
P9WB2L[1] [Pb] | KAD2RXD1[2] | 200 | .6 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
P9WB2L[1] [Pb] | EDR2RXD1 | 200 | .60 | Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction |
||
PWF-NL240V[1] | EDR5RXD1 | 240 | .5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
  [1] Product is authorized to bear the NSF and/or the cNSFus Mark. [2] KitchenAid® [3] Whirlpool® [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
CSA Standard B483.1
Drinking Water Treatment Systems
Drinking Water Treatment Systems
Electrolux Home Products | |
10200 David Taylor Drive | |
Charlotte, NC 28262 | |
United States | |
877-435-3287 | |
980-236-2000 | |
Visit this company's website |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
PureAdvantage PWF-1[2] | EPPWFU01 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage PWF-1-U[3] | EPPWFU01 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PureAdvantage PWF-1 with Performance Indicator Device. [3] PureAdvantage PWF-1-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Singapore, Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
PureAdvantage PWF-1[2] | EPPWFU01 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage PWF-1-U[3] | EPPWFU01 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PureAdvantage PWF-2[4] | EPPWFU02 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PureAdvantage PWF-1 with Performance Indicator Device. [3] PureAdvantage PWF-1-U without Performance Indicator Device. [4] PureAdvantage PWF-2 with Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Frigidaire Home Products | |
10200 David Taylor Drive | |
Charlotte, NC 28262 | |
United States | |
1-800-559-7569 | |
980-236-2000 |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
PurePour WF-1[2] | FPPWFU01 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PurePour WF-1-U[3] | FPPWFU01 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PurePour WF-1-M with Performance Indicator Device. [3] PurePour WF-1-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
PurePour Connect PWF-2[2] | FPPWFU02 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PurePour WF-1[3] | EPPWFU01 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PurePour WF-1-U[4] | EPPWFU01 | 200(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
PurePour WF-2[5] | FPPWFU02 | 125(1) | .65 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PurePour Connect PWF-2 with Performance Indicator Device. [3] PurePour WF-1 with Performance Indicator Device. [4] PurePour WF-1-U without Performance Indicator Device. [5] PurePour WF-2 with Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Brands Management Corporation | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2500 | |
Visit this company's website |
Facility : Pingtung, Taiwan
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
P8KB2L | 9081 | 200 | .75 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Linuron Reduction Nominal Particulate Reduction, Class I O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Taste and Odor Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Trimethoprim Reduction Turbidity Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Whirlpool Corporation | |
2000 North M-63 | |
Benton Harbor, MI 49085 | |
United States | |
269-923-7688 |
Facility : # 1 Taiwan
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
9083 [2] [Pb] | Filter 3 | 200 | .5 | Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Bisphenol A Reduction Carbamazepine Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction DEET Reduction Endrin Reduction Estrone Reduction Ethylbenzene Reduction Ibuprofen Reduction Lead Reduction Lindane Reduction Linuron Reduction MTBE Reduction Meprobamate Reduction Mercury Reduction Metolachlor Reduction Naproxen Reduction Nominal Particulate Reduction, Class I Nonylphenol Reduction O-Dichlorobenzene Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Taste and Odor Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Trimethoprim Reduction Turbidity Reduction VOC Reduction ** |
||
9085[2] [Pb] | Filter 5 | 240(1) | .5 | 2,4-D Reduction Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Bisphenol A Reduction Carbamazepine Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Lead Reduction Linuron Reduction Meprobamate Reduction Mercury Reduction Metolachlor Reduction Naproxen Reduction Nominal Particulate Reduction, Class I Nonylphenol Reduction P-Dichlorobenzene Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Taste and Odor Reduction Toxaphene Reduction Trimethoprim Reduction Turbidity Reduction |
||
EDR1RXD1B[2] [Pb] | EDR1RXD1B | 200 | .5 | Chlorine Reduction 1,2,4-Trichlorobenzene Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I O-Dichlorobenzene Reduction Endrin Reduction Ethylbenzene Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Lead Reduction Toxaphene Reduction Turbidity Reduction P-Dichlorobenzene Reduction Lindane Reduction Tetrachloroethylene Reduction Toluene Reduction Styrene Reduction Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction |
||
EDR2RXD1B[2] [Pb] | EDR2RXD1B | 200(1) | .6 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction O-Dichlorobenzene Reduction Endrin Reduction Ethylbenzene Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Lead Reduction Toxaphene Reduction Turbidity Reduction P-Dichlorobenzene Reduction Lindane Reduction Tetrachloroethylene Reduction Toluene Reduction Styrene Reduction 1,2,4-Trichlorobenzene Reduction Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction |
||
EDR3RXD1B[2] [Pb] | EDR3RXD1B | 200(1) | .5 | Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Bisphenol A Reduction Carbamazepine Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction DEET Reduction Endrin Reduction Estrone Reduction Ethylbenzene Reduction Ibuprofen Reduction Lead Reduction Lindane Reduction Linuron Reduction MTBE Reduction Meprobamate Reduction Mercury Reduction Metolachlor Reduction Naproxen Reduction Nominal Particulate Reduction, Class I Nonylphenol Reduction O-Dichlorobenzene Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Taste and Odor Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Trimethoprim Reduction Turbidity Reduction VOC Reduction ** |
||
EDR5RXD1B[2] [Pb] | EDR5RXD1B | 240(1) | .5 | 2,4-D Reduction Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Bisphenol A Reduction Carbamazepine Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Lead Reduction Linuron Reduction Meprobamate Reduction Mercury Reduction Metolachlor Reduction Naproxen Reduction Nominal Particulate Reduction, Class I Nonylphenol Reduction P-Dichlorobenzene Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Taste and Odor Reduction Toxaphene Reduction Trimethoprim Reduction Turbidity Reduction |
||
EVFILTER5[2] [Pb] | EVFILTER5 | 240 | .5 | Chlorine Reduction Lead Reduction |
||
EVFILTER5B[2] [Pb] | EVFILTER5B | 240 | .5 | Chlorine Reduction Lead Reduction |
||
FILTER1B[2] [Pb] | FILTER1B | 200 | .5 | Chlorine Reduction 1,2,4-Trichlorobenzene Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I O-Dichlorobenzene Reduction Endrin Reduction Ethylbenzene Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Lead Reduction Toxaphene Reduction Turbidity Reduction P-Dichlorobenzene Reduction Lindane Reduction Tetrachloroethylene Reduction Toluene Reduction Styrene Reduction Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction |
||
FILTER2B[2] [Pb] | FILTER2B | 200(1) | .6 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction O-Dichlorobenzene Reduction Endrin Reduction Ethylbenzene Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Lead Reduction Toxaphene Reduction Turbidity Reduction P-Dichlorobenzene Reduction Lindane Reduction Tetrachloroethylene Reduction Toluene Reduction Styrene Reduction 1,2,4-Trichlorobenzene Reduction Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction |
||
FILTER3B[2] [Pb] | FILTER3B | 200(1) | .5 | Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Bisphenol A Reduction Carbamazepine Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction DEET Reduction Endrin Reduction Estrone Reduction Ethylbenzene Reduction Ibuprofen Reduction Lead Reduction Lindane Reduction Linuron Reduction MTBE Reduction Meprobamate Reduction Mercury Reduction Metolachlor Reduction Naproxen Reduction Nominal Particulate Reduction, Class I Nonylphenol Reduction O-Dichlorobenzene Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Taste and Odor Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Trimethoprim Reduction Turbidity Reduction VOC Reduction ** |
||
FILTER5B[2] [Pb] | FILTER5B | 240(1) | .5 | 2,4-D Reduction Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Bisphenol A Reduction Carbamazepine Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Lead Reduction Linuron Reduction Meprobamate Reduction Mercury Reduction Metolachlor Reduction Naproxen Reduction Nominal Particulate Reduction, Class I Nonylphenol Reduction P-Dichlorobenzene Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Taste and Odor Reduction Toxaphene Reduction Trimethoprim Reduction Turbidity Reduction |
||
P1WB2[2] | EDR3RXD1 | 200(1) | .5 | Bisphenol A Reduction Carbamazepine Reduction Taste and Odor Reduction Chlorine Reduction Asbestos Reduction DEET Reduction Nominal Particulate Reduction, Class I MTBE Reduction Trihalomethanes (TTHM) Reduction Carbofuran Reduction VOC Reduction ** Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Ibuprofen Reduction |
||
P1WB2[2] [Pb] | WHR3RXD1[8] | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction O-Dichlorobenzene Reduction Endrin Reduction Ethylbenzene Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Asbestos Reduction Atrazine Reduction Lead Reduction Toxaphene Reduction Turbidity Reduction Lindane Reduction Tetrachloroethylene Reduction Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction MTBE Reduction Trihalomethanes (TTHM) Reduction Mercury Reduction VOC Reduction ** Meprobamate Reduction Metolachlor Reduction TCEP Reduction TCPP Reduction Ibuprofen Reduction |
||
P1WB2L[2] [Pb] | KAD3RXD1[7] | 200(1) | .5 | Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Bisphenol A Reduction Carbamazepine Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction DEET Reduction Endrin Reduction Estrone Reduction Ethylbenzene Reduction Ibuprofen Reduction Lead Reduction Lindane Reduction Linuron Reduction MTBE Reduction Meprobamate Reduction Mercury Reduction Metolachlor Reduction Naproxen Reduction Nominal Particulate Reduction, Class I Nonylphenol Reduction O-Dichlorobenzene Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Taste and Odor Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Trimethoprim Reduction Turbidity Reduction VOC Reduction ** |
||
P1WB2L[2] | EDR3RXD1 | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction Asbestos Reduction MTBE Reduction Trihalomethanes (TTHM) Reduction Carbofuran Reduction VOC Reduction ** Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Ibuprofen Reduction |
||
P1WB2L[2] [Pb] | WHR3RXD1[8] | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction O-Dichlorobenzene Reduction Endrin Reduction Ethylbenzene Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Asbestos Reduction Atrazine Reduction Lead Reduction Toxaphene Reduction Turbidity Reduction Lindane Reduction Tetrachloroethylene Reduction Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction MTBE Reduction Trihalomethanes (TTHM) Reduction Mercury Reduction VOC Reduction ** Meprobamate Reduction Metolachlor Reduction TCEP Reduction TCPP Reduction Ibuprofen Reduction |
||
P1WB2 [2] [Pb] | KAD3RXD1[7] | 200(1) | .5 | Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Bisphenol A Reduction Carbamazepine Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction DEET Reduction Endrin Reduction Estrone Reduction Ethylbenzene Reduction Ibuprofen Reduction Lead Reduction Lindane Reduction Linuron Reduction MTBE Reduction Meprobamate Reduction Mercury Reduction Metolachlor Reduction Naproxen Reduction Nominal Particulate Reduction, Class I Nonylphenol Reduction O-Dichlorobenzene Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Taste and Odor Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Trimethoprim Reduction Turbidity Reduction VOC Reduction ** |
||
P8WB2L[2] | EDR1RXD1 | 200 | .50 | Chlorine Reduction 1,2,4-Trichlorobenzene Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I O-Dichlorobenzene Reduction Endrin Reduction Ethylbenzene Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Lead Reduction Toxaphene Reduction Turbidity Reduction P-Dichlorobenzene Reduction Lindane Reduction Tetrachloroethylene Reduction Toluene Reduction Styrene Reduction Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction |
||
P8WB2L[2] [Pb] | KAD1RXD1[7] | 200(1) | .5 | Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Bisphenol A Reduction Carbamazepine Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction DEET Reduction Endrin Reduction Estrone Reduction Ethylbenzene Reduction Ibuprofen Reduction Lead Reduction Lindane Reduction Linuron Reduction MTBE Reduction Meprobamate Reduction Mercury Reduction Metolachlor Reduction Naproxen Reduction Nominal Particulate Reduction, Class I Nonylphenol Reduction O-Dichlorobenzene Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Taste and Odor Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Trimethoprim Reduction Turbidity Reduction VOC Reduction ** |
||
P8WB2L[2] [Pb] | WHR1RXD1[8] | 200(1) | .5 | Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Bisphenol A Reduction Carbamazepine Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction DEET Reduction Endrin Reduction Estrone Reduction Ethylbenzene Reduction Ibuprofen Reduction Lead Reduction Lindane Reduction Linuron Reduction MTBE Reduction Meprobamate Reduction Mercury Reduction Metolachlor Reduction Naproxen Reduction Nominal Particulate Reduction, Class I Nonylphenol Reduction O-Dichlorobenzene Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Taste and Odor Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Trimethoprim Reduction Turbidity Reduction VOC Reduction ** |
||
P9WB2L[2] [Pb] | WHR2RXD1[8] | 200(1) | .6 | Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Bisphenol A Reduction Carbamazepine Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction DEET Reduction Endrin Reduction Estrone Reduction Ethylbenzene Reduction Ibuprofen Reduction Lead Reduction Lindane Reduction Linuron Reduction MTBE Reduction Meprobamate Reduction Mercury Reduction Metolachlor Reduction Naproxen Reduction Nominal Particulate Reduction, Class I Nonylphenol Reduction O-Dichlorobenzene Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Taste and Odor Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Trimethoprim Reduction Turbidity Reduction VOC Reduction ** |
||
P9WB2L[2] [Pb] | KAD2RXD1[7] | 200(1) | .6 | Asbestos Reduction Atenolol Reduction Atrazine Reduction Benzene Reduction Bisphenol A Reduction Carbamazepine Reduction Carbofuran Reduction Chlorine Reduction Cyst Reduction DEET Reduction Endrin Reduction Estrone Reduction Ethylbenzene Reduction Ibuprofen Reduction Lead Reduction Lindane Reduction Linuron Reduction MTBE Reduction Meprobamate Reduction Mercury Reduction Metolachlor Reduction Naproxen Reduction Nominal Particulate Reduction, Class I Nonylphenol Reduction O-Dichlorobenzene Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Taste and Odor Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Trimethoprim Reduction Turbidity Reduction VOC Reduction ** |
||
P9WB2L[2] [Pb] | EDR2RXD1 | 200(1) | .60 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction O-Dichlorobenzene Reduction Endrin Reduction Ethylbenzene Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Lead Reduction Toxaphene Reduction Turbidity Reduction P-Dichlorobenzene Reduction Lindane Reduction Tetrachloroethylene Reduction Toluene Reduction Styrene Reduction 1,2,4-Trichlorobenzene Reduction Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Phenytoin Reduction Naproxen Reduction Bisphenol A Reduction Carbamazepine Reduction |
||
PWF-NL240V[2] | EDR5RXD1 | 240(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction Benzene Reduction Carbofuran Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction 2,4-D Reduction Atrazine Reduction Cyst Reduction Asbestos Reduction Turbidity Reduction Atenolol Reduction Estrone Reduction Linuron Reduction Nonylphenol Reduction Trimethoprim Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Ibuprofen Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] Product is authorized to bear the NSF and/or the cNSFus Mark. [7] KitchenAid® [8] Whirlpool® [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Electrolux Home Products | |
10200 David Taylor Drive | |
Charlotte, NC 28262 | |
United States | |
877-435-3287 | |
980-236-2000 | |
Visit this company's website |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
PureAdvantage PWF-1[2] | EPPWFU01 | 125 (1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureAdvantage PWF-1-U[3] | EPPWFU01 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureAdvantage PWF-2[4] | EPPWFU02 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PureAdvantage PWF-1 with Performance Indicator Device. [3] PureAdvantage PWF-1-U without Performance Indicator Device. [4] PureAdvantage PWF-2 with Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Singapore, Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
PureAdvantage PWF-1[2] | EPPWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction Atrazine Reduction |
||
PureAdvantage PWF-1-U[3] | EPPWFU01 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureAdvantage PWF-2[4] | EPPWFU02 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PureAdvantage WF-1-M with Performance Indicator Device. [3] PureAdvantage WF-1-U without Performance Indicator Device. [4] PureAdvantage PWF-2 with Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Frigidaire Home Products | |
10200 David Taylor Drive | |
Charlotte, NC 28262 | |
United States | |
1-800-559-7569 | |
980-236-2000 |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
PurePour Connect PWF-2[2] | FPPWFU02 | 125(1) | .65 | Asbestos Reduction 2,4-D Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction Mercury Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction |
||
PurePour WF-1[3] | FPPWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction |
||
PurePour WF-1-U[4] | FPPWFU01 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction |
||
PurePour WF-2[5] | FPPWFU02 | 125(1) | .65 | Asbestos Reduction 2,4-D Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction Mercury Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PurePour Connect PWF-2 with Performance Indicator Device. [3] PurePour WF-1 with Performance Indicator Device. [4] PurePour WF-1-U without Performance Indicator Device. [5] PurePour WF-2 with Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
PurePour Connect PWF-2[2] | FPPWFU02 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction |
||
PurePour WF-1[3] | FPPWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction |
||
PurePour WF-1-U[4] | FPPWFU01 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction |
||
PurePour WF-2[5] | FPPWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PurePour Connect PWF-2 with Performance Indicator Device. [3] PurePour WF-1 with Performance Indicator Device. [4] PurePour WF-1-U without Performance Indicator Device. [5] PurePour WF-2 with Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Number of matching Manufacturers is 82
Number of matching Products is 1102