NSF/ANSI 419
Public Drinking Water Equipment Performance - Filtration
Facility : Israel
|
|
|
Microfiber Filter[1]
|
|
AMF-36K DW[2] |
|
AMF-370K DW[4] |
|
AMF-93K DW[3] |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 2.76 log, and a minimum LRV of 2.15 log.
[2] Tested at maximum design flow rate of 44 gpm (10 m3/hr).
[3] Certified flow rate of 114.4 gpm (26 m3/hr).
[4] Certified flow rate of 457.5 gpm (103.9 m3/hr).
|
DDP Specialty Electronic Materials US, Inc. | |
1803 Building | |
Midland, MI 48674 | |
United States | |
1-800-FILMTEC | |
989-638-6231 | |
Visit this company's website |
Facility : Zhejiang, China
|
|
|
Ultrafiltration Devices
|
|
DOW IntegraFlux™ Ultrafiltration Module SFD-2860XP[1] |
|
DOW IntegraFlux™ Ultrafiltration Module SFD-2880XP[1] |
|
DOW IntegraPac™ Ultrafiltration Module IPD-51XP[1] |
|
DOW IntegraPac™ Ultrafiltration Module IPD-77XP[1] |
|
IntegraFlo IC-50XP Ultrafiltration Module[1] |
|
UXA-2680XP Ultrafiltration Module[1] |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.33 log, and a minimum LRV of 6.22 log. The maximum Certified filtrate flux
is 70 gfd. Also tested for virus reduction on 11/18/2020, with a mean LRV of 2.00 log,
and a minimum LRV of 1.85 log.
|
Facility : Windsor, Australia
|
|
|
Ultrafiltration Devices
|
|
L10N Module / 120283[1] |
|
L20N Module / 120285[1] |
|
L40N Module / 120309[2] |
|
L40N Module / 120492[2] |
|
S10N Module / 119221, 119222[1] |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.16, and a minimum LRV of 6.10 log. The maximum certified filtrate flux is
155 gfd, which equals a flow rate of 32.5 gpm.
[2] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 5.71, and a minimum LRV of 3.48 log. The maximum Certified filtrate flux is 85
gfd, which equals a flow rate of 42.6 gpm.
|
Facility : Oceanside, CA
|
|
|
Ultrafiltration Devices[1]
|
|
HYDRAcap® AM |
|
HYDRAcap® MAX 40 |
|
HYDRAcap® MAX 60 |
|
HYDRAcap® MAX 80 |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 5.81 log, and a minimum LRV of 5.54 log. The maximum certified filtrate flux
rate is 120 gfd.
|
Facility : Greifenberg, Germany
|
|
|
Ultrafiltration Devices[1]
|
|
dizzer® P 2514-0.5 |
|
dizzer® P 2521-1.0 |
|
dizzer® P 4021-2.5 |
|
dizzer® P 4040-6.0 |
|
dizzer® L 0.9 MB 40 PB |
|
dizzer® XL 0.9 MB 60 |
|
dizzer® XL 0.9 MB 60W |
|
dizzer® XL 0.9 MB 60 WT |
|
dizzer® XL 0.9 MB 70W |
|
dizzer® XL 0.9 MB 70WT |
|
dizzer® XL 0.9 MB 80W |
|
dizzer® XL 0.9 MB 80WT |
|
dizzer® XL 1.5 MB 40W |
|
dizzer® XL 1.5 MB 50W |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
LRV) of 6.48 log, and a minimum LRV of 6.41 log. The maximum Certified filtrate flux is
106 gfd.
|
Meidensha Corporation | |
Meiko Building | |
5-5-5 Osaki Shinagawa-ku | |
Tokyo 1418616 | |
Japan | |
81 3 6420 7409 | |
Facility : Aichi, Japan
|
|
|
Ultrafiltration Devices[1]
|
|
CH250-1000E01K-5NA |
|
CH250-1000E02K-5NA |
|
CH250-1000E03K-5NA |
|
CH250-1000TM100-U1DJ-EKFPA0 |
|
CH250-1000TM100-U1DJ-ETLWA0 |
|
CH250-1000TM100-U2DJ-EKFPA0 |
|
CH250-1000TM100-U2DJ-ETLWA0 |
|
CH250-1000TM50-U1SJ-EKFPA0 |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.09 log and a minimum LRV of 5.87 log. The maximum certified filtrate flow
rate is 100 LPH (GPH), maximum flux rate is 200 LMH (GFD). Also tested 11/10/2015 for
bacteria removal efficiency, with a mean LRV of 5.93 log and a minimum LRV of 5.48 log.
Also tested 11/10/2015 for virus removal efficiency with aluminum sulfate, with a mean
LRV of 4.18 log and a minimum LRV of 4.10 log.
|
Facility : Beijing Scinor Membrane Technology Co., Ltd., China
|
|
|
Ultrafiltration Devices
|
|
SMT600-P23[1] |
|
SMT600-P38[1] |
|
SMT600-P50[2] |
|
SMT600-P51[2] |
|
SMT600-P52[2] |
|
SMT600-P53[2] |
|
SMT600-P55[2] |
|
SMT600-P56[2] |
|
SMT600-P57[2] |
|
SMT600-P60[2] |
|
SMT600-P72[2] |
|
SMT600-P80[2] |
|
SMT600-P81[2] |
|
SMT600-S26[3] |
|
SMT600-S40[3] |
|
SMT600-S48[3] |
|
SMT600-S51[3] |
|
SMT600-S60[3] |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.25 log, and a minimum LRV of 6.08 log. The maximum certified filtrate flux
rate is 120 gfd. Also tested 2/22/2016 for virus removal efficiency, with a mean LRV of
4.34 and a minimum LRV of 2.69 log.
[2] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.32 log, and a minimum LRV of 6.19 log. The maximum certified filtrate flux
rate is 120 gfd. Also tested 01/06/2021 for virus removal efficiency, with a mean LRV of
5.20 and a minimum LRV of 5.07 log.
[3] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.37 log, and a minimum LRV of 6.19 log. The maximum certified filtrate flux
rate is 120 gfd. Also tested 2/22/2016 for virus removal efficiency, with a mean LRV of
4.37 and a minimum LRV of 3.63 log.
|
SUEZ Water Technologies & Solutions | |
4636 Somerton Road | |
Trevose, PA 19053 | |
United States | |
888-898-6766 | |
215-942-3534 | |
Facility : Oroszlány, Hungary
|
|
|
Ultrafiltration Device
|
|
ZeeWeed 500d UF[1] |
[1] Certified by NSF for Cryptosporidium, with a mean log removal value (LRV) of 6.02 log
and a minimum LRV of 5.02 log. The maximum certified filtrate flux rate is 50 gfd,
which equals a flow rate of 15.3 gpm.
|
Facility : Zeewolde, The Netherlands
|
|
|
Ultrafiltration Devices[1]
|
|
ZW700B - 8060 |
|
ZW700B -10060 |
|
ZW700B-4100 |
|
ZW700B-4150 |
|
ZW700B-450 |
|
ZW700B-6100 |
|
ZW700B-9060 |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.01 log, and a minimum LRV of 5.41 log. The maximum certified filtrate flux
rate is 100 gfd, which equals a flow rate of 29.9 gpm.
|
Facility : # 1 China
|
|
|
Ultrafiltration Devices[1]
|
|
HFU-2020AN |
|
HFUG-2020AN |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.28 log, and a minimum LRV of 5.20 log. Maximum Certified filtrate flow rate
is 244 LPM (64.6 GPM), and maximum Certified flux is 204 LMH (120 GFD). Also tested for
virus removal efficiency on December 4-5, 2018, with a mean LRV of 2.16 log, and a
minimum LRV of 1.67 log.
|
Facility : # 1 Korea
|
|
|
Ultrafiltration Devices
|
|
HFU-2020AN[1] |
|
HFU-B2315AN[2] |
|
HFUG-2020AN[1] |
|
HFUG-B2315AN[2] |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.28 log, and a minimum LRV of 5.20 log. Maximum Certified filtrate flow rate
is 244 LPM (64.6 GPM), and maximum Certified flux is 204 LMH (120 GFD). Also tested for
virus removal efficiency on December 4-5, 2018, with a mean LRV of 2.16 log, and a
minimum LRV of 1.67 log.
[2] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.05 log, and a minimum LRV of 5.05 log. Maximum Certified filtrate flow rate
is 204 LPM (53.8 GPM), and maximum Certified flux is 204 LMH (120 GFD). Also tested for
virus removal efficiency on May 6-7, 2019, with a mean LRV of 1.39 log, and a minimum
LRV of 1.14 log.
|
X-Flow B.V. | |
Marssteden 50 | |
7547 Tc Enschede | |
The Netherlands | |
31-53 428 7350 | |
Facility : Enschede, The Netherlands
|
|
|
Nanofiltration Device[1] [2]
|
|
HFW 1000 |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
of 6.32 log, and a minimum LRV of 5.75 log. The maximum certified filtration flux rate
is 23.5 gfd.
[2] Also tested 6/20/2016 for virus removal efficiency, with a mean LRV of 5.54 and a
minimum LRV of 5.44 log.
|
Ultrafiltration Device[3] [4]
|
|
Aquaflex |
|
Aquaflex HP |
|
XIGA |
|
XIGA HP |
[3] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.39 log, and a minimum LRV of 6.29 log. The maximum certified filtrate flux
is 73.5 gfd.
[4] X-Flow membrane filtration elements are available in Xiga and Aquaflex types with
membrane filtration surfaces of 40m2 and the Aquaflex HP and Xiga HP types, whereas HP
is a placeholder for 55 or 64 m2.
|
NSF Certification Guideline
Public Drinking Water Equipment Performance
NeoTech Aqua Solutions, Inc. | |
5893 Oberlin Drive | |
Suite 104 | |
San Diego, CA 92121 | |
United States | |
888-718-5040 | |
858-571-6590 | |
Visit this company's website |
Facility : San Diego, CA
|
|
|
Ultraviolet Reactor Devices[1]
|
|
NeoTech Aqua D438™ |
[1] Certified by NSF as achieving a minimum of 3-log inactivation of Cryptosporidium at
three conditions of sensor readings and flow rates (control set points). The three
control set points determined for a minimum 3-log inactivation of Cryptosporidium are
151 gpm - 7.9 mW/cm2; 251 gpm - 10.4 mW/cm2; and 501 gpm - 12.5 mW/cm2.
|
Number of matching Manufacturers is 11
Number of matching Products is 78