NSF Product and Service Listings

These NSF Official Listings are current as of Monday, May 13, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Plumbing/Listings.asp?MaterialType=PEX&

Did you know?

The new NSF Product Listings website is available for NSF/ANSI 14-Certified products with a new look and feel. Click on "Try it Now" to check it out!

NSF/ANSI 14
Plastics Piping System Components and Related Materials


Click here for a list of End Use Code Designations.

Click on Product Standards or footnote in blue to view the referenced document



 
Alro Products International 
2348 Linden Boulevard
Brooklyn 
New York, NY 11208 
United States 
718-566-1000
Visit this company's website

Facility : Barcelona, Spain

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
ALROPEX
 
ASTM F876/F877
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2" sizes. Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
ALROPEX
 
CSA B137.5
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2" sizes. Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* @ ¢ §
 
PEX 5106
 
ALROPEX
 
ASTM F876/F877
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue,white and orange) are certified for the following sizes: 3/8", 1/2", 5/8",
  3/4", 1'', 1 1/2", & 2".
  
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and ASTM F2098.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh),	applications only.				
  
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* @ ¢ §
 
PEX 5106
 
ALROPEX
 
CSA B137.5
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue,white and orange) are certified for the following sizes: 3/8", 1/2", 5/8",
  3/4", 1'', 1 1/2", & 2".
  
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and ASTM F2098.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh),	applications only.				
  
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
ATI Systems, Inc. 
4339 Main Street
Conestoga, PA 17516 
United States 
717-871-9851
Visit this company's website

Facility : Guangdong, China

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * §
 
PEX 5006
 
American Hydronics
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * ¢ § [1]
 
PEX
 
American Hydronics
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1]  Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
     fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
     marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
     F1960, F2098.

Tubing* ^ ¢ ~  +++ [G]
 
PEX 5006
 
American Hydronics
 
ASTM F876/F877
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
~  Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
   red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ ~  +++ [G] [1]
 
PEX 5006
 
American Hydronics
 
CSA B137.5
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
~  Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
   red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[1]  Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
     fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
     marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
     F1960, F2098.



 
Auray Managing, S.L.U. 
P.I. Riera de Caldes
Carrer dels Mercaders, 42, Palau-solità 
i Plegamans, Barcelona 08184 
Spain 
34 93 748 10 36
Visit this company's website

Facility : Barcelona, Spain

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
PIPEX
 
ASTM F876/F877
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes. 
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
PIPEX
 
CSA B137.5
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes. 
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* @ ¢ §
 
PEX 5106
 
PIPEX
 
ASTM F876/F877
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white and orange) are certified for the following sizes: 3/8", 1/2", 5/8",
  3/4", 1", 1-1/4", 1-1/2" & 2".
  
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and ASTM F2098.
@ This tubing product has been evaluated against the performance requirements of
  ASTM	F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable
  water distribution system.  This product has been evaluated for use in radiant floor
  heating, (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* @ ¢ §
 
PEX 5106
 
PIPEX
 
CSA B137.5
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white and orange) are certified for the following sizes: 3/8", 1/2", 5/8",
  3/4", 1", 1-1/4", 1-1/2" & 2".
  
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and ASTM F2098.
@ This tubing product has been evaluated against the performance requirements of
  ASTM	F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable
  water distribution system.  This product has been evaluated for use in radiant floor
  heating, (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
Borealis AB 
SE 444 86 Stenungsund
Sweden 
46 303 860 00
Visit this company's website

Facility : Stenungsund, Sweden

Potable Water - Materials

Material Type End Use Trade Name Product Standard
PEX 5006* ^ +++ 1 HE1878E-C2 N/A
PEX 5106* ^ +++ 1 HE1878E-C3 N/A

* Use of this material in NSF Certified tubing requires NSF's prior authorization.  Tubing
  produced from this material was tested to the performance requirements of ASTM F876.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).


Radiant Floor Heating - Materials

Material Type End Use Trade Name Product Standard
PEX 5006* 1 HE1878E-C2 N/A
PEX 5106* 1 HE1878E-C3 N/A

* Use of this material in NSF Certified tubing requires NSF's prior authorization.  Tubing
  produced from this material was tested to the performance requirements of ASTM F876.

NSF Certified materials and generic ingredients are exempt from bearing an NSF Certification Mark. Certified materials and generic ingredients are identified by the manufacturer name, facility location, and trade designation as shown in the Official Listing.



 
Bow Plumbing Group, Inc. 
5700 Cote de Liesse
Montreal, QC H4T 1B1 
Canada 
450-372-5481
Visit this company's website

Facility : # 2 Granby, Quebec, Canada

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing# [1]
 
PEX
 
Bowpex
 
ASTM E84
1/2" (without insulation)

# Certified Bowpex tubing is natural, red, or white.
[1] Flame Spread Index <=25, Smoke Developed Index <=50.
    Flame Spread Index and Smoke Developed Index for ASTM E84 is based on minimum spacing of
    18 inches between tubing runs.  Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2
    FS25/SD50].

Tubing# ¢ [2]
 
PEX
 
Bowpex
 
CAN/ULC S102.2
1/2" (without insulation)

# Certified Bowpex tubing is natural, red, or white.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] Flame Spread Value <=25, Smoke Developed Value <=50.
    Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50].

Tubing# ¢ [3]
 
PEX
 
Bowpex
 
CAN/ULC S102.2
1/8", 1/4", 3/8", 3/4", 1" (with insulation)

# Certified Bowpex tubing is natural, red, or white.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[3] Flame Spread Value <=25, Smoke Developed Value <=50.
    The Flame Spread Value and Smoke Developed Value is based on when tubing is field
    insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation as per Bow
    installation instructions.   Tubing shall be marked [cNSF®-fs ULCS102.2 FS25/SD50].

Tubing% [1]
 
PEX
 
Oxypex
 
ASTM E84
1/2" (without insulation)

% Certified Oxypex tubing has a red outer layer.
[1] Flame Spread Index <=25, Smoke Developed Index <=50.
    Flame Spread Index and Smoke Developed Index for ASTM E84 is based on minimum spacing of
    18 inches between tubing runs.  Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2
    FS25/SD50].

Tubing% ¢ [2]
 
PEX
 
Oxypex
 
CAN/ULC S102.2
1/2" (without insulation)

% Certified Oxypex tubing has a red outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] Flame Spread Value <=25, Smoke Developed Value <=50.
    Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50].

Tubing% ¢ [3]
 
PEX
 
Oxypex
 
CAN/ULC S102.2
1/4", 3/8", 5/8", 3/4", 1" (with insulation)

% Certified Oxypex tubing has a red outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[3] Flame Spread Value <=25, Smoke Developed Value <=50.
    The Flame Spread Value and Smoke Developed Value is based on when tubing is field
    insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation as per Bow
    installation instructions.   Tubing shall be marked [cNSF®-fs ULCS102.2 FS25/SD50].

Tubing@ [1]
 
PEX
 
Superpex
 
ASTM E84
1/2" (without insulation)

@ Certified Bow Superpex tubing has a blue, red, or white outer layer.
[1] Flame Spread Index <=25, Smoke Developed Index <=50.
    Flame Spread Index and Smoke Developed Index for ASTM E84 is based on minimum spacing of
    18 inches between tubing runs.  Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2
    FS25/SD50].

Tubing@ ¢ [2]
 
PEX
 
Superpex
 
CAN/ULC S102.2
1/2" (without insulation)

@ Certified Bow Superpex tubing has a blue, red, or white outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] Flame Spread Value <=25, Smoke Developed Value <=50.
    Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50].

Tubing@ ¢ [3]
 
PEX
 
Superpex
 
CAN/ULC S102.2
1/4", 3/8", 3/4", 1" (with insulation)

@ Certified Bow Superpex tubing has a blue, red, or white outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[3] Flame Spread Value <=25, Smoke Developed Value <=50.
    The Flame Spread Value and Smoke Developed Value is based on when tubing is field
    insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation as per Bow
    installation instructions.   Tubing shall be marked [cNSF®-fs ULCS102.2 FS25/SD50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing! $ * ^ § ++ [G]
 
PEX 5106/5306
 
Bowpex
 
ASTM F876/F877
1/8" - 2" SDR 9

! Product may or may not bear the NSF U.P. code marking.
$ Certified Bowpex tubing is natural (PEX 5106), red, white, and blue (PEX 5306).
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ & ¢ ++ [G]
 
PEX
 
Bowpex
 
CSA B137.5
1/8" - 2" SDR 9

$ Certified Bowpex tubing is natural (PEX 5106), red, white, and blue (PEX 5306).
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting
  system(s) for which the tubing is recommended by the manufacturer, and shall be marked
  with the
  following fitting system designations: ASTM F1807, ASTM F2159.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * @ ^ § ++ [G]
 
PEX 5306
 
Bow Superpex
 
ASTM F876/F877

SDR 9
1/4" - 1 1/4"  

! Product may or may not bear the NSF U.P. code marking.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Certified Bow Superpex tubing has a blue, red, or white outer layer.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * @ ^ § ++ [G]
 
PEX 5306
 
Bow Superpex
 
AWWA C904
1/2" - 1 1/4" SDR 9

! Product may or may not bear the NSF U.P. code marking.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Certified Bow Superpex tubing has a blue, red, or white outer layer.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& @ ¢ ++ [G]
 
PEX
 
Bow Superpex
 
CSA B137.5
1/4" - 1 1/4" SDR 9

& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting
  system(s) for which the tubing is recommended by the manufacturer, and shall be marked
  with the
  following fitting system designations: ASTM F1807, ASTM F2159.
@ Certified Bow Superpex tubing has a blue, red, or white outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! $ % * ^ ¢ ++ [G]
 
PEX 5106
 
Oxypex
 
ASTM F876/F877
1/4" - 2" SDR 9

! Product may or may not bear the NSF U.P. code marking.
$ Certified Bowpex tubing is natural (PEX 5106), red, white, and blue (PEX 5306).
% Certified Oxypex tubing has a red outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing% & ¢ ++ [G]
 
PEX
 
Oxypex
 
CSA B137.5
1/4" - 2" SDR 9

% Certified Oxypex tubing has a red outer layer.
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting
  system(s) for which the tubing is recommended by the manufacturer, and shall be marked
  with the
  following fitting system designations: ASTM F1807, ASTM F2159.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing! % * ^ ¢ §
 
PEX 5106
 
Oxypex
 
ASTM F876/F877
1/4" - 2" SDR 9

! Product may or may not bear the NSF U.P. code marking.
% Certified Oxypex tubing has a red outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing% ¢
 
PEX
 
Oxypex
 
CSA B137.5
1/4" - 2" SDR 9

% Certified Oxypex tubing has a red outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.

$ Bow OXYPERT is red, green or blue in color.


 
Calefactio Solutions Inc. 
1120 Boulevard Michele-Bohec
Blainville 
Quebec, QC J7C 5N5 
Canada 
450-951-0818

Facility : Barcelona, Spain

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* ¢ § +++ [G]
 
PEX 5106
 
CALEFACTIO
 
ASTM F876/F877
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes. Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following
  fitting system designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM F2098.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
CALEFACTIO
 
CSA B137.5
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes. Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following
  fitting system designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106 : Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* @ ¢ §
 
PEX 5106
 
CALEFACTIO
 
ASTM F876/F877

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue,white and orange) are certified for the following sizes: 3/8", 1/2", 5/8",
  3/4", 1", 1-1/2" & 2".
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and
  ASTM F2098.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* @ ¢ §
 
PEX 5106
 
CALEFACTIO
 
CSA B137.5

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue,white and orange) are certified for the following sizes: 3/8", 1/2", 5/8",
  3/4", 1", 1-1/2" & 2".
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and
  ASTM F2098.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
Cash Acme / Reliance Worldwide 
2400 7th Avenue Southwest
Cullman, AL 35055 
United States 
256-775-8184

Facility : Middlefield, OH

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing# @ ^ § +++ [G]
 
PEX 5106
 
SHARKBITE®
 
ASTM F876/F877
1/4" - 1" SDR 9

# Authorized for gray and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# & @ ¢ +++ [G]
 
PEX 5106
 
SHARKBITE®
 
CSA B137.5
1/4" - 1" SDR 9

# Authorized for gray and white.
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations: ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061, and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing# * @ ^ ¢ §
 
PEX 5006
 
SHARKBITE®
 
ASTM F876/F877
3/8" - 1" SDR 9

# Authorized for orange color.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# & * @ ¢
 
PEX 5006
 
SHARKBITE®
 
CSA B137.5
3/8" - 1" SDR 9

# Authorized for orange color.
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations: ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061, and ASTM F1960.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.



 
CB Supplies Ltd. 
3325 190th Street
Surrey, BC V3S 0L5 
Canada 
800-665-1851 
604-535-5088

Facility : Surrey, British Columbia, Canada

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
CANFLEX™
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing? @ ^ ~ § +++ [G]
 
PEX 5306
 
Canflex
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ @ ^ ~ ¢ § +++ [3] [G]
 
PEX 5306
 
CANFLEX™
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
CANPEX™
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing? @ ^ ~ § +++ [G]
 
PEX 5306
 
CanPEX
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ @ ^ ~ ¢ § +++ [3] [G]
 
PEX 5306
 
CANPEX™
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ § +++ [G]
 
PEX 5206
 
CanPEX Barrier
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ ¢ § +++ [3] [G]
 
PEX 5206
 
CanPEX Barrier
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ § +++ [G]
 
PEX 5206
 
CanPEX OXY Barrier
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ ¢ § +++ [3] [G]
 
PEX 5206
 
CanPEX OXY Barrier
 
CSA B137.5
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ^ ~ § µ +++ [G]
 
PEX 5306
 
CanPEX Ultra
 
ASTM F876/F877
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ^ ~ ¢ § µ +++ [3] [G]
 
PEX 5306
 
CanPEX Ultra
 
CSA B137.5
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
CANPEX™ UV
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing? @ ^ ~ § +++ [G]
 
PEX 5306
 
CanPEX UV
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [3] [G]
 
PEX 5306
 
CANPEX™ UV
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
CANPEX™ UV +
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing? @ ^ ~ § +++ [G]
 
PEX 5306
 
CanPEX UV+
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [3] [G]
 
PEX 5306
 
CANPEX™ UV +
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
CANPEX™ UV + MD
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing? @ ^ ~ § +++ [G]
 
PEX 5306
 
CanPEX UV+MD
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [3] [G]
 
PEX 5306
 
CANPEX™ UV + MD
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
CANPEX™ UV Plus
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing? @ ^ ~ § +++ [G]
 
PEX 5306
 
CanPEX UV Plus
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [3] [G]
 
PEX 5306
 
CANPEX™ UV Plus
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
CANPEX™ UV Plus MD
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing? @ ^ ~ § +++ [G]
 
PEX 5306
 
CanPEX UV Plus MD
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [3] [G]
 
PEX 5306
 
CANPEX™ UV Plus MD
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
CANPLUMB™
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing? @ ^ ~ § +++ [G]
 
PEX 5306
 
CanPLUMB
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ @ ^ ~ ¢ § +++ [3] [G]
 
PEX 5306
 
CANPLUMB™
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ § +++ [G]
 
PEX 5206
 
CanRay
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ ¢ § +++ [3] [G]
 
PEX 5206
 
CanRay
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ § Þ
 
PEX 5206
 
Embassy / LiquiPEX w/O2 Barrier
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
Þ Product is Certified to the International Plumbing Code. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  International Plumbing Code.

Tubing! # $ % ^ ~ ¢ § Þ [3]
 
PEX 5206
 
Embassy / LiquiPEX w/O2 Barrier
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
Þ Product is Certified to the International Plumbing Code. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  International Plumbing Code.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
LYNX-PEX
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing? @ ^ ~ § +++ [G]
 
PEX 5306
 
LYNX-PEX
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [3] [G]
 
PEX 5306
 
LYNX-PEX
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
Radiant Floor Company/ DURA-POLY XL
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [3] [G]
 
PEX 5306
 
Radiant Floor Company/ DURA-POLY XL
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ ^ ~ § +++ [G]
 
PEX 5206
 
Radiant Floor Company / DURA-POLY XL
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ ¢ § +++ [3] [G]
 
PEX 5206
 
Radiant Floor Company/ DURA-POLY XL
 
CSA B137.5
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ @ ^ ~ § +++ [G]
 
PEX 5206
 
Radiantec Company Inc. / Radiantec
 
ASTM F876/F877
1/2" - 3/4" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ ¢ § +++ [3] [G]
 
PEX 5206
 
Radiantec Company Inc. / Radiantec
 
CSA B137.5
1/2" - 3/4" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ § +++ [G]
 
PEX 5206
 
RadiantMax
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ ¢ § +++ [3] [G]
 
PEX 5206
 
RadiantMax
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
Vanex
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing? @ ^ ~ § +++ [G]
 
PEX 5306
 
Vanex
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ @ ^ ~ ¢ § +++ [3] [G]
 
PEX 5306
 
Vanex
 
CSA B137.5
1/4" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ ¢ § +++ [3] [G]
 
PEX 5206
 
Vanex Barrier
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ % ^ ~ § +++ [G]
 
PEX 5206
 
Vanex Barrier
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ^ ~ § µ +++ [G]
 
PEX 5306
 
Vanex Ultra
 
ASTM F876/F877
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ^ ~ ¢ § µ +++ [3] [G]
 
PEX 5306
 
Vanex Ultra
 
CSA B137.5
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Reclaimed Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe# @ §
 
PEX 5306
 
Canflex
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe@ §
 
PEX 5306
 
Canflex
 
AWWA C904
1/2" - 2" SDR 9

@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# @ ¢ § [1]
 
PEX 5306
 
Canflex
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASSE 1061.

Pipe# @ §
 
PEX 5306
 
CanPEX
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe@ §
 
PEX 5306
 
CanPEX
 
AWWA C904
1/2" - 2" SDR 9

@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# @ ¢ § [1]
 
PEX 5306
 
CanPEX
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASSE 1061.

Pipe# @ §
 
PEX 5306
 
CanPex UV
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe@ §
 
PEX 5306
 
CanPex UV
 
AWWA C904
1/2" - 2" SDR 9

@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# @ ¢ § [1]
 
PEX 5306
 
CanPex UV
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASSE 1061.

Pipe# @ §
 
PEX 5306
 
CanPex UV Plus
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe@ §
 
PEX 5306
 
CanPex UV Plus
 
AWWA C904
1/2" - 2" SDR 9

@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# @ ¢ § [1]
 
PEX 5306
 
CanPex UV Plus
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASSE 1061.

Pipe# @ §
 
PEX 5306
 
CanPex UV Plus MD
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe@ §
 
PEX 5306
 
CanPex UV Plus MD
 
AWWA C904
1/2" - 2" SDR 9

@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# @ ¢ § [1]
 
PEX 5306
 
CanPex UV Plus MD
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASSE 1061.

Pipe# @ §
 
PEX 5306
 
CanPEX UV+
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe@ §
 
PEX 5306
 
CanPEX UV+
 
AWWA C904
1/2" - 2" SDR 9

@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# @ ¢ § [1]
 
PEX 5306
 
CanPEX UV+
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASSE 1061.

Pipe# @ §
 
PEX 5306
 
CanPEX UV+MD
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe@ §
 
PEX 5306
 
CanPEX UV+MD
 
AWWA C904
1/2" - 2" SDR 9

@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# @ ¢ § [1]
 
PEX 5306
 
CanPEX UV+MD
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASSE 1061.

Pipe# @ §
 
PEX 5306
 
CanPLUMB
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe@ §
 
PEX 5306
 
CanPLUMB
 
AWWA C904
1/2" - 2" SDR 9

@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# @ ¢ § [1]
 
PEX 5306
 
CanPLUMB
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASSE 1061.

Pipe# @ §
 
PEX 5306
 
LYNX-PEX
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe@ §
 
PEX 5306
 
LYNX-PEX
 
AWWA C904
1/2" - 2" SDR 9

@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# @ ¢ § [1]
 
PEX 5306
 
LYNX-PEX
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASSE 1061.

Pipe# @ §
 
PEX 5306
 
Radiant Floor Company/DURA-POLY XL
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe@ §
 
PEX 5306
 
Radiant Floor Company/DURA-POLY XL
 
AWWA C904
1/2" - 2" SDR 9

@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# @ ¢ § [1]
 
PEX 5306
 
Radiant Floor Company/DURA-POLY XL
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASSE 1061.

Pipe# @ §
 
PEX 5306
 
Vanex
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe@ §
 
PEX 5306
 
Vanex
 
AWWA C904
1/2" - 2" SDR 9

@ Certified for purple color.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# @ ¢ § [1]
 
PEX 5306
 
Vanex
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd.
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
@ Certified for purple color.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASSE 1061.


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ ? @ ^ ~ ¢ §
 
PEX 5306
 
CANFLEX™
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ @ ^ ~ ¢ § [1]
 
PEX 5306
 
CANFLEX™
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ? @ ^ ~ §
 
PEX 5306
 
CANPEX™
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ @ ^ ~ ¢ § [1]
 
PEX 5306
 
CANPEX™
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing! # $ % ^ ~ §
 
PEX 5206
 
CanPEX Barrier
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! # $ % ^ ~ ¢ § [1]
 
PEX 5206
 
CanPEX Barrier
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing! # $ % ^ ~ §
 
PEX 5206
 
CanPEX OXY Barrier
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! # $ % ^ ~ ¢ § [1]
 
PEX 5206
 
CanPEX OXY Barrier
 
CSA B137.5
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ^ ~ § µ
 
PEX 5306
 
CanPEX Ultra
 
ASTM F876/F877
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.

Tubing# $ ^ ~ ¢ § µ [1]
 
PEX 5306
 
CanPEX Ultra
 
CSA B137.5
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ? @ ^ ~ §
 
PEX 5306
 
CANPEX™ UV
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ ? @ ^ ~ ¢ § [1]
 
PEX 5306
 
CANPEX™ UV
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ? @ ^ ~ §
 
PEX 5306
 
CANPEX™ UV +
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ ? @ ^ ~ ¢ § [1]
 
PEX 5306
 
CANPEX™ UV +
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ? @ ^ ~ §
 
PEX 5306
 
CANPEX™ UV + MD
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ ? @ ^ ~ ¢ § [1]
 
PEX 5306
 
CANPEX™ UV + MD
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ? @ ^ ~ §
 
PEX 5306
 
CANPEX™ UV Plus
 
ASTM F876/F877
3/8" - 2' SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ ? @ ^ ~ ¢ § [1]
 
PEX 5306
 
CANPEX™ UV Plus
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ? @ ^ ~ §
 
PEX 5306
 
CANPEX™ UV Plus MD
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ ? @ ^ ~ ¢ § [1]
 
PEX 5306
 
CANPEX™ UV Plus MD
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ? @ ^ ~ §
 
PEX 5306
 
CANPLUMB™
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ @ ^ ~ ¢ § [1]
 
PEX 5306
 
CANPLUMB™
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing! # $ % ^ ~ §
 
PEX 5206
 
CanRay
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! # $ % ^ ~ ¢ § [1]
 
PEX 5206
 
CanRay
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing! # $ % ^ ~ § Þ
 
PEX 5206
 
Embassy / LiquiPEX w/O2 Barrier
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
Þ Product is Certified to the International Plumbing Code. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  International Plumbing Code.

Tubing! # $ % ^ ~ ¢ § Þ [1]
 
PEX 5206
 
Embassy / LiquiPEX w/O2 Barrier
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
Þ Product is Certified to the International Plumbing Code. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  International Plumbing Code.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ? @ ^ ~ §
 
PEX 5306
 
LYNX-PEX
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing? @ ^ ~ §
 
PEX 5306
 
LYNX-PEX
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ ? @ ^ ~ ¢ § [1]
 
PEX 5306
 
LYNX-PEX
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ? @ ^ ~
 
PEX 5306
 
Radiant Floor Company/ DURA-POLY XL
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.

Tubing# $ ? @ ^ ~ ¢ § [1]
 
PEX 5306
 
Radiant Floor Company/ DURA-POLY XL
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing! # $ % ^ ~ §
 
PEX 5206
 
Radiant Floor Company/ DURA-POLY XL
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! # $ % ^ ~ ¢ § [1]
 
PEX 5206
 
Radiant Floor Company/ DURA-POLY XL
 
CSA B137.5
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing! # $ % ^ ~ §
 
PEX 5206
 
Radiantec Company Inc. / Radiantec
 
ASTM F876/F877
1/2" - 3/4" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! # $ % ^ ~ §
 
PEX 5206
 
RadiantMax
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! # $ % ^ ~ ¢ § [1]
 
PEX 5206
 
RadiantMax
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ? @ ^ ~ §
 
PEX 5306
 
Vanex
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ @ ^ ~ ¢ § [1]
 
PEX 5306
 
Vanex
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing! # $ % ^ ~ §
 
PEX 5206
 
Vanex Barrier
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! # $ % ^ ~ ¢ § [1]
 
PEX 5206
 
Vanex Barrier
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.

Tubing# $ ^ ~ § µ
 
PEX 5306
 
Vanex Ultra
 
ASTM F876/F877
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.

Tubing# $ ^ ~ ¢ § µ [1]
 
PEX 5306
 
Vanex Ultra
 
CSA B137.5
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.



 
Cirque Sales & Distribution, Inc 
13504 Northeast 84th Street
Suite 103-267 
Vancover, WA 98682 
United States 
888-710-6667 
360-326-7003

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX® Pro Blue UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX® Pro Blue UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX® Pro Red UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX® Pro Red UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX® Pro White UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX® Pro White UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

$ Non-barrier pipe.


 
Elkhart Supply Corporation 
1126 Kent Street
Elkhart, IN 46514-1740 
United States 
574-264-4156

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX® Pro Blue UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX® Pro Blue UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX® Pro Red UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX® Pro Red UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX® Pro White UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX® Pro White UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

$ Non-barrier pipe.


 
Embassy Industries, Inc. 
10 Hub Drive
Melville, NY 11747 
United States 
631-694-1800
Visit this company's website

Facility : Middlefield, OH

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing# * @ ^ ¢ §
 
PEX 5006
 
Embassy LiquiPEX
 
ASTM F876/F877
3/8" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# & * @ ¢
 
PEX
 
Embassy LiquiPEX
 
CSA B137.5
3/8" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.



 
Everflow Supplies Inc. 
100 Middlesex Avenue
Carteret, NJ 07008 
United States 
908-436-1100

Facility : Foshan, China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
PEXFLOW™
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for blue and red without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ § +++ [3] [G]
 
PEX
 
PEXFLOW™
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for blue and red without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be 
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ § +++
 
PEX 5006
 
PEXFLOW™
 
ASTM F876/F877
1/2" - 1" SDR 9

$ Certified for blue and red without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing$ * ^ ¢ § +++
 
PEX
 
PEXFLOW™
 
CSA B137.5
1/2" - 1" SDR 9

$ Certified for blue and red without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing& * ^ ~ ¢ +++ [G]
 
PEX 5106[6]
 
Everflow
 
CSA B137.5

>= 1/8" SDR 9
PFW-R12100   PFW-B12100   PFW-W12100   PFW-R12300  
PFW-B12300   PFW-W12300   PFW-R12500   PFW-B12500  
PFW-W12500   PFW-R34100   PFW-B34100   PFW-W34100  
PFW-R34300   PFW-B34300   PFW-W34300   PFW-R34500  
PFW-B34500   PFW-W34500   PFW-B1100   PFW-R1100  
PFW-W1100   PFW-R1300   PFW-B1300   PFW-W1300  
PFW-R1500   PFW-B1500   PFW-W1500   PFW-R1220  
PFW-B1220   PFW-W1220   PFW-R3420   PFW-B3420  
PFW-W3420   PFW-R120   PFW-B120   PFW-W120  
PFW-R1210   PFW-B1210   PFW-W1210   PFW-R3410  
PFW-B3410   PFW-W3410   PFW-R110   PFW-B110  
PFW-W110  

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G]
 
PEX 5106[6]
 
Everflow
 
ASTM F876/877

>= 1/8" SDR 9
PFW-R12100   PFW-B12100   PFW-W12100   PFW-R12300  
PFW-B12300   PFW-W12300   PFW-R12500   PFW-B12500  
PFW-W12500   PFW-R34100   PFW-B34100   PFW-W34100  
PFW-R34300   PFW-B34300   PFW-W34300   PFW-R34500  
PFW-B34500   PFW-W34500   PFW-B1100   PFW-R1100  
PFW-W1100   PFW-R1300   PFW-B1300   PFW-W1300  
PFW-R1500   PFW-B1500   PFW-W1500   PFW-R1220  
PFW-B1220   PFW-W1220   PFW-R3420   PFW-B3420  
PFW-W3420   PFW-R120   PFW-B120   PFW-W120  
PFW-R1210   PFW-B1210   PFW-W1210   PFW-R3410  
PFW-B3410   PFW-W3410   PFW-R110   PFW-B110  
PFW-W110  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Fittings[4] [G]
 
PEX
 
Everflow
 
ASTM F1960

PEX Ring with Stop
3/8" - 2"  

[4] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted product.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Fittings[4] [G]
 
PEX
 
Everflow
 
CSA B137.5

PEX Ring with Stop
3/8" - 2"  

[4] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted product.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
Everflow
 
ASTM F876/877

1/8" - 6" SDR 9
PFW-R12100   PFW-B12100   PFW-W12100   PFW-R12300  
PFW-B12300   PFW-W12300   PFW-R12500   PFW-B12500  
PFW-W12500   PFW-R34100   PFW-B34100   PFW-W34100  
PFW-R34300   PFW-B34300   PFW-W34300   PFW-R34500  
PFW-B34500   PFW-W34500   PFW-B1100   PFW-R1100  
PFW-W1100   PFW-R1300   PFW-B1300   PFW-W1300  
PFW-R1500   PFW-B1500   PFW-W1500   PFW-R1220  
PFW-B1220   PFW-W1220   PFW-R3420   PFW-B3420  
PFW-W3420   PFW-R120   PFW-B120   PFW-W120  
PFW-R1210   PFW-B1210   PFW-W1210   PFW-R3410  
PFW-B3410   PFW-W3410   PFW-R110   PFW-B110  
PFW-W110  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
Everflow
 
CSA B137.5

1/8" - 6" SDR 9
PFW-R12100   PFW-B12100   PFW-W12100   PFW-R12300  
PFW-B12300   PFW-W12300   PFW-R12500   PFW-B12500  
PFW-W12500   PFW-R34100   PFW-B34100   PFW-W34100  
PFW-R34300   PFW-B34300   PFW-W34300   PFW-R34500  
PFW-B34500   PFW-W34500   PFW-B1100   PFW-R1100  
PFW-W1100   PFW-R1300   PFW-B1300   PFW-W1300  
PFW-R1500   PFW-B1500   PFW-W1500   PFW-R1220  
PFW-B1220   PFW-W1220   PFW-R3420   PFW-B3420  
PFW-W3420   PFW-R120   PFW-B120   PFW-W120  
PFW-R1210   PFW-B1210   PFW-W1210   PFW-R3410  
PFW-B3410   PFW-W3410   PFW-R110   PFW-B110  
PFW-W110  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G]
 
PEX 5106[7]
 
Everflow
 
ASTM F876/877

3/8" - 1"
PFW-R12100   PFW-B12100   PFW-W12100   PFW-R12300  
PFW-B12300   PFW-W12300   PFW-R12500   PFW-B12500  
PFW-W12500   PFW-R34100   PFW-B34100   PFW-W34100  
PFW-R34300   PFW-B34300   PFW-W34300   PFW-R34500  
PFW-B34500   PFW-W34500   PFW-B1100   PFW-R1100  
PFW-W1100   PFW-R1300   PFW-B1300   PFW-W1300  
PFW-R1500   PFW-B1500   PFW-W1500   PFW-R1220  
PFW-B1220   PFW-W1220   PFW-R3420   PFW-B3420  
PFW-W3420   PFW-R120   PFW-B120   PFW-W120  
PFW-R1210   PFW-B1210   PFW-W1210   PFW-R3410  
PFW-B3410   PFW-W3410   PFW-R110   PFW-B110  
PFW-W110  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[7] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8",3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
    5/8",3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[8]
 
Everflow
 
ASTM F876/877
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[8] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [5] [G]
 
PEX 5106[8]
 
Everflow
 
CSA B137.5
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159.
[8] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [5] [G]
 
PEX 5006
 
Everflow
 
CSA B137.5
1/8" - 3"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing& * ^ ~ ¢ +++
 
PEX 5106[7] [8]
 
Everflow
 
CSA B137.5
PFR-R1100
PFR-R120
PFR-R12100
PFR-R121000
PFR-R121200
PFR-R1220
PFR-R12300
PFR-R12500
PFR-R1300
PFR-R1500
PFR-R34100
PFR-R341000
PFR-R3420
PFR-R34300
PFR-R34500
PFR-R38100
PFR-R38300
PFR-R58100
PFR-R58500

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with  
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange,natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[7] Certified for red and white PEX 5106 monowall pipe.
[8] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, ASTM F2098 and ASSE 1061.

Tubing* ^ ¢ +++
 
PEX 5106[7]
 
Everflow
 
ASTM F876/877

>= 1/8"
PFR-R1100   PFR-R120   PFR-R12100   PFR-R121000  
PFR-R121200   PFR-R1220   PFR-R12300   PFR-R12500  
PFR-R1300   PFR-R1500   PFR-R34100   PFR-R341000  
PFR-R3420   PFR-R34300   PFR-R34500   PFR-R38100  
PFR-R38300   PFR-R58100   PFR-R58500  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with  
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[7] Certified for red and white PEX 5106 monowall pipe.

Fittings[6]
 
PEX
 
Everflow
 
ASTM F1960

PEX Ring with Stop
3/8" - 2"  

[6] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted product.

Fittings[6]
 
PEX
 
Everflow
 
CSA B137.5

PEX Ring with Stop
3/8" - 2"  

[6] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted product.

Tubing$ * ¢ § [8]
 
PEX
 
Everflow
 
CSA B137.5

>= 1/8" SDR 9
PFR-R1100   PFR-R120   PFR-R12100   PFR-R121000  
PFR-R121200   PFR-R1220   PFR-R12300   PFR-R12500  
PFR-R1300   PFR-R1500   PFR-R34100   PFR-R341000  
PFR-R3420   PFR-R34300   PFR-R34500   PFR-R38100  
PFR-R38300   PFR-R58100   PFR-R58500  

$ Certified for blue and red with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[8] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, ASTM F2098 and ASSE 1061.

Tubing! * ^ §
 
PEX 5106
 
Everflow
 
ASTM F876/877

>= 1/8" SDR 9
PFR-R1100   PFR-R120   PFR-R12100   PFR-R121000  
PFR-R121200   PFR-R1220   PFR-R12300   PFR-R12500  
PFR-R1300   PFR-R1500   PFR-R34100   PFR-R341000  
PFR-R3420   PFR-R34300   PFR-R34500   PFR-R38100  
PFR-R38300   PFR-R58100   PFR-R58500  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with  
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5106
 
Everflow
 
AWWA C904

1/2" - 1 1/2" SDR 9
PFR-R1100   PFR-R120   PFR-R12100   PFR-R121000  
PFR-R121200   PFR-R1220   PFR-R12300   PFR-R12500  
PFR-R1300   PFR-R1500   PFR-R34100   PFR-R341000  
PFR-R3420   PFR-R34300   PFR-R34500   PFR-R38100  
PFR-R38300   PFR-R58100   PFR-R58500  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with  
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5106
 
Everflow
 
CSA B137.5

>= 1/8" SDR 9
PFR-R1100   PFR-R120   PFR-R12100   PFR-R121000  
PFR-R121200   PFR-R1220   PFR-R12300   PFR-R12500  
PFR-R1300   PFR-R1500   PFR-R34100   PFR-R341000  
PFR-R3420   PFR-R34300   PFR-R34500   PFR-R38100  
PFR-R38300   PFR-R58100   PFR-R58500  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with  
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5006
 
Everflow
 
ASTM F876/877
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with  
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange,natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[5]
 
Everflow
 
ASTM F876/877
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with  
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange,natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5006[4]
 
Everflow
 
CSA B137.5
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with  
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange,natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[4] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be 
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [5] [G]
 
PEX 5106[4]
 
Everflow
 
CSA B137.5
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with  
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange,natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[4] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be 
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, F2098.
[5] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * §
 
PEX 5006
 
PEXFLOW™
 
ASTM F876/F877
1/2" - 1" SDR 9

$ Certified for blue and red with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * ¢ §
 
PEX
 
PEXFLOW™
 
CSA B137.5
1/2" - 1" SDR 9

$ Certified for blue and red with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * §
 
PEX 5006
 
PEXFLOW™
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for blue and red with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * ¢ § [4]
 
PEX
 
PEXFLOW™
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for blue and red with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be 
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, F2098.

Tubing$ * §
 
PEX 5006
 
PEXFLOW™
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for blue and red with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
Everflow Supplies, Inc. 
100 Middlesex Avenue
Carteret, NJ 07008 
United States 
877-941-7800 
908-436-1100
Visit this company's website

Facility : Barcelona, Spain

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
PEXFLOW
 
ASTM F876/F877
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes. Red, blue, white or orange PEX
  pipe (2
  layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes. Tubing
  certified
  against CSA B137.5 shall include the standard designation(s) of the fitting system(s)
  for which the
  tubing is recommended by the manufacturer, and shall be marked, as applicable, with the
  following
  fitting system designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
PEXFLOW
 
CSA B137.5
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes. Red, blue, white or orange PEX
  pipe (2
  layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes. Tubing
  certified
  against CSA B137.5 shall include the standard designation(s) of the fitting system(s)
  for which the
  tubing is recommended by the manufacturer, and shall be marked, as applicable, with the
  following
  fitting system designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* @ ¢ §
 
PEX 5106
 
PEXFLOW
 
CSA B137.5
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white and orange) are certified for the following sizes: 3/8", 1/2", 5/8",
  3/4", 1", 1 1/2", & 2".
  
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and ASTM F2098
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA
  which the tubing is recommended by the 
  B137.5. This product is not NSF Certified for use in a potable water distribution
  system. This
  product has been evaluated for use in radiant floor heating, (NSF-rfh), applications only
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* @ ¢ §
 
PEX 5106
 
PEXFLOW
 
ASTM F876/F877
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white and orange) are certified for the following sizes: 3/8", 1/2", 5/8",
  3/4", 1", 1 1/2", & 2".
  
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and ASTM F2098
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA
  which the tubing is recommended by the 
  B137.5. This product is not NSF Certified for use in a potable water distribution
  system. This
  product has been evaluated for use in radiant floor heating, (NSF-rfh), applications only
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
Everhot Inc. 
5407 Foster Avenue
Brooklyn, NY 11234 
United States 
347-492-7660

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ *
 
PEX
 
Everhot
 
ASTM E84

3/8", 1/2" - 2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing$ &
 
PEX
 
Everhot
 
CAN/ULC S102.2

3/8", 1/2" - 2"
Flame Spread Rating <= 25   Smoke Developed Classification <= 50  

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ ¢ § +++ [G]
 
PEX
 
Everhot
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
Everhot
 
ASTM F876/F877
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
Everhot
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ¢ §
 
PEX
 
Everhot
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for blue, natural, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * §
 
PEX 5006
 
Everhot
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for blue, natural, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
EZ Flo International 
1605 Research Circle
Rockwall, TX 75032 
United States 
800-486-5256
Visit this company's website

Facility : # 2 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing# @ ^ § +++ [G]
 
PEX 5106
 
Eastman® PEX
 
ASTM F876/F877
1/8" - 1 1/4" SDR 9

# Authorized for gray and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing@ ^ § +++ [G]
 
PEX 5106
 
Eastman® PEX
 
ASTM F876/F877
1/8" CTS x 1/4" OD SDR 9

@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# & @ ¢ +++ [G]
 
PEX 5106
 
Eastman® PEX
 
CSA B137.5
1/8" - 1 1/4" SDR 9

# Authorized for gray and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations: ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& @ ¢ +++ [G]
 
PEX 5106
 
Eastman® PEX
 
CSA B137.5
1/8" CTS x 1/4" OD SDR 9

& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations: ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# @ ^ § +++ [G]
 
PEX 5106
 
Merflex PEX
 
ASTM F876/F877
1/8" - 1 1/4" SDR 9

# Authorized for gray and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing@ ^ § +++ [G]
 
PEX 5106
 
Merflex PEX
 
ASTM F876/F877
1/8" CTS x 1/4" OD SDR 9

@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# & @ ¢ +++ [G]
 
PEX 5106
 
Merflex PEX
 
CSA B137.5
1/8" - 1 1/4" SDR 9

# Authorized for gray and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations: ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& @ ¢ +++ [G]
 
PEX 5106
 
Merflex PEX
 
CSA B137.5
1/8" CTS x 1/4" OD SDR 9

& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations: ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Finproject S.p.A. 
Compounding BU – Roccabianca Plant
Via Paganina 3 
I-43010 Roccabianca (PR) 
Italy 
0039 0521 5291

Facility : Roccabianca, Italy

Potable Water - Materials

Material Type End Use Trade Name Product Standard
PEX 3006$ * +++ 1 Polidan T/A + Catalyst Masterbatch PS/2 N/A
PEX 3006$ * +++ 1 Polidan T/A + Catalyst Masterbatch PS/4 N/A
PEX 3006$ * +++ 1 Polidan T/A HF + Catalyst Masterbatch PS/2 N/A
PEX 3006$ * +++ 1 olidan T/A HF + Catalyst Masterbatch PS/4 N/A

$ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
* Tubing manufactured using this material is cure process dependent. Use of this material
  in NSF Certified tubing requires NSF's prior authorization.  Tubing produced from this
  material was tested to the performance requirements of ASTM F876.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).



 
GE Appliances, a Haier Company 
Appliance Park
Louisville, KY 40225 
United States 
502-452-3332
Visit this company's website

Facility : # 1 USA

Potable Water - Appurtenances

Product Type   Material Type   Trade Name   Product Standard

Refrigerator Supply Line# & ¢ § [G]
 
PEX
 
GE Appliances
 
ASME A112.18.6/CSA B125.6
1/8" C.T.S.

# This product may be marked via a flag type label.
& Certified up to 8 feet in length.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Giacomini S.P.A. 
Via Per Alzo 39
28017 S. Maurizio D' Opaglio (NO) 
Italy 
39 0322 923372
Visit this company's website

Facility : D'Opaglio (NO), Italy

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe
 
PEX 0006
 
L996 PE-X Pipe
 
ASTM F876/F877
3/8" - 1"

Pipe
 
PEX 0006
 
L996 PE-X Pipe
 
CSA B137.5
3/8" - 1"

Pipe
 
PEX 0006
 
R996 PE-X Pipe
 
ASTM F876/F877
3/8" - 1"

Pipe
 
PEX 0006
 
R996 PE-X Pipe
 
CSA B137.5
3/8" - 1"



 
Golan Plastic Products Ltd. 
Kibbutz Shaar Hagolan
M.P. Jordan Valley 15145 
Israel 
972 46 677432
Visit this company's website

Facility : Jordan Valley, Israel

Oil and Gas Producing Applications - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing
 
PEX 0006
 
Pexgol PE-Xa Black
 
ASTM F2905
3" - 18" SDR 7.3
3" - 20" SDR 8.3
3" - 24" SDR 9
3" - 36" SDR 11
3" - 36" SDR 13.5
3" - 48" SDR 15.5
3" - 54" SDR 17
3" - 54" SDR 21
16 mm - 355 mm SDR 6
16 mm - 450 mm SDR 7.4
16 mm - 800 mm SDR 9
16 mm - 630 mm SDR 11
16 mm - 630 mm SDR 13.6
16 mm - 630 mm SDR 16.2
16 mm - 630 mm SDR 17
16 mm - 630 mm SDR 21


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe^ § $$ +++
 
PEX 5106
 
AquaHeat PE-Xa Natural
 
ASTM F876/F877
3/8" - 1" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 3106
 
AquaHeat PE-Xa Natural
 
ASTM F2788/F2788M
1/2" - 14" SDR 6 DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" DR 9
16 mm - 630 mm DR 9
3/4" - 25" DR 11
20 mm - 630 mm DR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" DR 17
32 mm - 630 mm DR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 3106
 
AquaHeat PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 3106
 
AquaHeat PE-Xa Natural
 
CSA B137.5
3/8" - 6" DR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 5106
 
AquaHeat PE-Xa Natural
 
CSA B137.5
3/8" - 1" DR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaHeat PE-Xc Black
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" DR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaHeat PE-Xc Blue
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" DR 9
16 mm - 25 mm DR 9
3/4" - 1" DR 11
20 mm - 25 mm DR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaHeat PE-Xc Natural
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" DR 9
16 mm - 25 mm DR 9
3/4" - 1" DR 11
20 mm - 25 mm DR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaHeat PE-Xc Red
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" DR 9
16 mm - 25 mm DR 9
3/4" - 1" DR 11
20 mm - 25 mm DR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 3106
 
AquaSeal PE-Xa Natural
 
ASTM F2788/F2788M
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 3106
 
AquaSeal PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ § $$ +++
 
PEX 5106
 
AquaSeal PE-Xa Natural
 
ASTM F876/F877
3/8" - 1" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 3106
 
AquaSeal PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 5106
 
AquaSeal PE-Xa Natural
 
CSA B137.5
3/8" - 1" DR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaSeal PE-Xc Black
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaSeal PE-Xc Blue
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaSeal PE-Xc Natural
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaSeal PE-Xc Red
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 3106
 
HeatFlow PEX PE-Xa Natural
 
ASTM F2788/F2788M
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ $$ +++
 
PEX 3106
 
HeatFlow PEX PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ § $$ +++
 
PEX 5106
 
HeatFlow PEX PE-Xa Natural
 
ASTM F876/F877
3/8" - 1" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 5106
 
HeatFlow PEX PE-Xa Natural
 
CSA B137.5
3/8" - 1" DR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 3106
 
HeatFlow PEX PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
HeatFlow PEX PE-Xc Black
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
HeatFlow PEX PE-Xc Blue
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
HeatFlow PEX PE-Xc Red
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
HeatFlow PEX PE-Xc Natural
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 3106
 
Pexgol PE-Xa Black
 
ASTM F876/F877
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing* ^ ¢ § $$ +++
 
PEX 3106
 
Pexgol PE-Xa Black
 
ASTM F2788/F2788M
3" SDR 9
16 mm - 76 mm SDR 9
3" - 14" SDR 6 DR 6
16 mm - 355 mm DR 6
3" - 18" DR 7.4
16 mm - 450 mm DR 7.4
3" - 25" DR 9
16 mm - 630 mm DR 9
3" - 25" DR 11
20 mm - 630 mm DR 11
3" - 25" DR 13.6
25 mm - 630 mm DR 13.6
3" - 25" DR 16.2
32 mm - 630 mm DR 16.2
3" - 25" DR 17
32 mm - 630 mm DR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 5006
 
Pexgol PE-Xa Black
 
CSA B137.5
3/8" - 1" DR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 3106
 
Pexgol PE-Xa Natural
 
ASTM F2788/F2788M
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 3106
 
Pexgol PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ § $$ +++
 
PEX 5106
 
Pexgol PE-Xa Natural
 
ASTM F876/F877
3/8" - 1" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 3106
 
Pexgol PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 5106
 
Pexgol PE-Xa Natural
 
CSA B137.5
3/8" - 1" DR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 3106
 
Sioux Chief PE-Xa Natural
 
ASTM F2788/F2788M
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Pexgol PE-Xc Black
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Pexgol PE-Xc Blue
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Pexgol PE-Xc Red
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Pexgol PE-Xc Natural
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 3106
 
Plumber Friendly PE-Xa Natural
 
ASTM F2788/F2788M
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 3106
 
Plumber Friendly PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ § $$ +++
 
PEX 5106
 
Plumber Friendly PE-Xa Natural
 
ASTM F876/F877
3/8" - 1" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 3106
 
Plumber Friendly PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 3106
 
Sioux Chief PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 5106
 
Plumber Friendly PE-Xa Natural
 
CSA B137.5
3/8" - 1" DR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Plumber Friendly PE-Xc Black
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Plumber Friendly PE-Xc Blue
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm SDR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Plumber Friendly PE-Xc Natural
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" DR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Plumber Friendly PE-Xc Red
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm SDR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 3106
 
Slant/Fin Heating PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 3106
 
Sioux Chief PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ § $$ +++
 
PEX 5106
 
Sioux Chief PE-Xa Natural
 
ASTM F876/F877
3/8" - 1" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 5106
 
Sioux Chief PE-Xa Natural
 
CSA B137.5
3/8" - 1" DR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ § $$ +++
 
PEX 5106
 
Slant/FIN Heating PE-Xa Natural
 
ASTM F876/F877
3/8" - 1" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 3106
 
Slant/Fin Heating PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Heating PE-Xc Black
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Heating PE-Xc Blue
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" Sch 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 3106
 
Slant/Fin Heating PE-Xa Natural
 
ASTM F2788/F2788M
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 16.2
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Heating PE-Xc Natural
 
ASTM F2788/F2788M
20 mm - 25 mm SDR 11
3/4" - 1" SDR 11
16 mm - 25 mm SDR 9
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
25 mm DR 13.6
1" DR 13.6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 6
1/2" - 1" DR 6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Heating PE-Xc Red
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 3106
 
Slant/Fin Plumbing PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 3106
 
Slant/Fin Plumbing PE-Xa Natural
 
ASTM F2788/F2788M
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ § $$ +++
 
PEX 5106
 
Slant/FIN Plumbing PE-Xa Natural
 
ASTM F876/F877
3/8" - 1" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 5106
 
Slant/FIN Plumbing PE-Xa Natural
 
CSA B137.5
3/8" - 1" DR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 3106
 
Slant/Fin Plumbing PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Black
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm SIDR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Blue
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Natural
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Red
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Sioux Chief PE-Xc Black
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 3106
 
Terratherma PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 3106
 
Terratherma PE-Xa Natural
 
ASTM F2788/F2788M
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ § $$ +++
 
PEX 5106
 
Terratherma PE-Xa Natural
 
ASTM F876/F877
3/8" - 1" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 5106
 
Terratherma PE-Xa Natural
 
CSA B137.5
3/8" - 1" DR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ^ ¢ § $$ +++
 
PEX 3106
 
Terratherma PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Terratherma PE-Xc Black
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Terratherma PE-Xc Blue
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Terratherma PE-Xc Natural
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Terratherma PE-Xc Red
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Sioux Chief PE-Xc Blue
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Sioux Chief PE-Xc Natural
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Sioux Chief PE-Xc Red
 
ASTM F2788/F2788M
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe¢ § $$
 
PEX 3106
 
Sioux Chief PEX PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe# ¢ § $$
 
PEX 3106
 
Sioux Chief PEX PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
Sioux Chief PEX PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Sioux Chief PEX PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Sioux Chief PEX PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Sioux Chief PEX PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Slant/Fin Heating PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Slant/Fin Heating PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 3106
 
Slant/Fin Heating PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe# ¢ § $$
 
PEX 3106
 
Slant/Fin Heating PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
Slant/Fin Heating PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Slant/Fin Heating PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 3106
 
Slant/Fin Plumbing PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe# ¢ § $$
 
PEX 3106
 
Slant/Fin Plumbing PE-Xa Natural
 
CSA B137.5

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Red
 
ASTM F876/F877
3/8" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 3106
 
Pexgol PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe# ¢ § $$
 
PEX 3106
 
Pexgol PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
Pexgol PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Pexgol PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Pexgol PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Pexgol PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 3106
 
Terratherma PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe# ¢ § $$
 
PEX 3106
 
Terratherma PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
Terratherma PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Terratherma PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Terratherma PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Terratherma PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 3106
 
AquaSeal PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe# ¢ § $$
 
PEX 3106
 
AquaSeal PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
AquaSeal PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
AquaSeal PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
AquaSeal PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
AquaSeal PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 3106
 
AquaHeat PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe# ¢ § $$
 
PEX 3106
 
AquaHeat PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
AquaHeat PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
AquaHeat PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
AquaHeat PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
AquaHeat PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe! &
 
PEX 5006
 
PENTAGOL
 
ASTM F876/F877
1/2", 5/8" SDR 9

! Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing. Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s): ASTM F2080, ASTM F1960.
& This is a 5 layer construction pipe (PEX-adhesive-EVOH-adhesive-PEX). This product is
  produced in red, blue, black and natural.

Pipe! & ¢
 
PEX 5006
 
PENTAGOL
 
CSA B137.5
1/2", 5/8" SDR 9

! Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing. Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s): ASTM F2080, ASTM F1960.
& This is a 5 layer construction pipe (PEX-adhesive-EVOH-adhesive-PEX). This product is
  produced in red, blue, black and natural.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.

Pipe¢ § $$
 
PEX 3106
 
Plumber Friendly PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe# ¢ § $$
 
PEX 3106
 
Plumber Friendly PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  qualified through testing.  Please verify that tubing certified against CSA B137.5 is
  only marked with the following fitting system designation(s):  ASTM F877, ASTM F2080,
  ASTM F1960.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
Plumber Friendly PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Plumber Friendly PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Plumber Friendly PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Plumber Friendly PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
HAB Inc. 
306 Broadway
Providencia, RI 02908 
United States 
508-615-1308

Facility : Barcelona, Spain

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
HAB
 
ASTM F876/F877
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8"" - 2""sizes.  Red, blue, white or orange
  PEX pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8"" - 2""
  sizes. Tubing certified against CSA B137.5 shall include the standard designation(s) of
  the fitting system(s) for which the tubing is recommended by the manufacturer, and shall
  be marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023. 
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
HAB
 
CSA B137.5
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8"" - 2""sizes.  Red, blue, white or orange
  PEX pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8"" - 2""
  sizes. Tubing certified against CSA B137.5 shall include the standard designation(s) of
  the fitting system(s) for which the tubing is recommended by the manufacturer, and shall
  be marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023. 
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* @ ¢ §
 
PEX 5106
 
HAB
 
ASTM F876/F877
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white and orange) are certified for the following sizes: 3/8", 1/2", 5/8",
  3/4", 1", 1-1/4", 1-1/2" & 2".
  
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and ASTM F2098.			
  
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* @ ¢ §
 
PEX 5106
 
HAB
 
CSA B137.5
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white and orange) are certified for the following sizes: 3/8", 1/2", 5/8",
  3/4", 1", 1-1/4", 1-1/2" & 2".
  
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and ASTM F2098.			
  
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.				
      


 
HDC Hyundai Engineering Plastics Co., Ltd. 
1221-32 Daehoman-ro, Seokmum-myeon
Dangjin-si, Chungnam 343-856 
Korea, Republic of 
82 41 350 0593
Visit this company's website

Facility : Chungcheongnam-do, Korea, Republic of

Potable Water - Materials

Material Type End Use Trade Name Product Standard
PEX 5306* ^ ¢ +++ 1 Polylink XP650/XC200 (Black) N/A
PEX 5106* ^ ¢ +++ 1 Polylink XP650/XC200 (Natural) N/A
PEX 5306* ^ ¢ +++ 1 Polylink XP650/XC200 (Red) N/A
PEX 5306* ^ ¢ +++ 1 Polylink XP650/XC200 (White) N/A
PEX 5306* ^ ¢ +++ 1 Polylink XP650/XC200B (Blue) N/A

* Tubing manufactured from this material is cure process dependent.  Use of this material
  in NSF Standard 14/61 Certified pipe requires NSF's prior authorization.  Tubing
  produced from this material was evaluated for 1/2" and greater diameters.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).



 
Heatlink Group 
4306E-13 Street NE
Calgary, AB T2E 6M3 
Canada 
403-717-3820

Facility : P3 USA

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing^ § **
 
PEX
 
PureLink Plus
 
ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <= 50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing^ § **
 
PEX
 
SureLink
 
ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <= 50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing! # * ¢ § ++ [G]
 
PEX 5106/5306
 
PureLink Plus
 
ASTM F876/F877
3/8" - 2"

! Certified for blue, natural, red colors, PEX 5106 only.
# Certified for Blue and Red adhesive outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # * ^ ~ ¢ § ++ [1] [G]
 
PEX 5106/5306
 
PureLink Plus
 
CSA B137.5
3/8" - 2"

! Certified for blue, natural, red colors, PEX 5106 only.
# Certified for Blue and Red adhesive outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Pipe may have a blue, red or white coating, PEX 5106 only.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[1]  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * ¢ § ++ [G]
 
PEX 5306
 
PureLink Plus
 
AWWA C904
1/2" - 2" SDR 9

# Certified for Blue and Red adhesive outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ¢ § +++ [1] [2] [G]
 
PEX 5306
 
PurePEX
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1]  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[2] Certified for Red, Blue and White Colors
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ¢ § +++ [1] [2] [G]
 
PEX 5306
 
PurePEX
 
CSA B137.5
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1]  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[2] Certified for Red, Blue and White Colors
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ¢ § +++ [1] [2] [G]
 
PEX 5306
 
PurePEX
 
AWWA C904
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1]  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[2] Certified for Red, Blue and White Colors
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # * ^ ~ ¢ § ++ [G]
 
PEX 5106/5306
 
SureLink
 
ASTM F876/F877
3/8" - 2"

! Certified for blue, natural, red colors, PEX 5106 only.
# Certified for Blue and Red adhesive outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Pipe may have a blue, red or white coating, PEX 5106 only.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # * ^ ~ ¢ § ++ [1] [G]
 
PEX 5106/5306
 
SureLink
 
CSA B137.5
3/8" - 2"

! Certified for blue, natural, red colors, PEX 5106 only.
# Certified for Blue and Red adhesive outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Pipe may have a blue, red or white coating, PEX 5106 only.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[1]  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * ¢ § ++ [G]
 
PEX 5306
 
SureLink
 
AWWA C904
1/2" - 2" SDR 9

# Certified for Blue and Red adhesive outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Facility : Calgary, Alberta, Canada

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing^ § **
 
PEX
 
PureLink Plus
 
ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <= 50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing^ § **
 
PEX
 
SureLink
 
ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <= 50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing! # * ^ ~ ¢ § ++ [G]
 
PEX 5106/5306
 
PureLink Plus
 
ASTM F876/F877
3/8" - 2"

! Certified for blue, natural, red colors, PEX 5106 only.
# Certified for Blue and Red adhesive outer layer, PEX 5306 only.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Pipe may have a blue, red or white coating, PEX 5106 only.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # * ^ ~ ¢ § ++ [1] [G]
 
PEX 5106/5306
 
PureLink Plus
 
CSA B137.5
3/8" - 2"

! Certified for blue, natural, red colors, PEX 5106 only.
# Certified for Blue and Red adhesive outer layer, PEX 5306 only.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Pipe may have a blue, red or white coating, PEX 5106 only.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * ~ ¢ § ++ [G]
 
PEX 5306
 
PureLink Plus
 
AWWA C904
1/2" - 2" SDR 9

# Certified for Blue and Red adhesive outer layer, PEX 5306 only.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # * ^ ~ ¢ § ++ [G]
 
PEX 5106/5306
 
SureLink
 
ASTM F876/F877
3/8" - 2"

! Certified for blue, natural, red colors, PEX 5106 only.
# Certified for Blue and Red adhesive outer layer, PEX 5306 only.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Pipe may have a blue, red or white coating, PEX 5106 only.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # * ~ ¢ § ++ [1] [G]
 
PEX 5106/5306
 
SureLink
 
CSA B137.5
3/8" - 2"

! Certified for blue, natural, red colors, PEX 5106 only.
# Certified for Blue and Red adhesive outer layer, PEX 5306 only.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * ~ ¢ § ++ [G]
 
PEX 5306
 
SureLink
 
AWWA C904
1/2" - 2" SDR 9

# Certified for Blue and Red adhesive outer layer, PEX 5306 only.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Reclaimed Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing¢
 
PEX 5106
 
PureLink Reclaim
 
ASTM F876/F877
3/8" - 2"

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.

Tubing¢ [1]
 
PEX 5106
 
PureLink Reclaim
 
CSA B137.5
3/8" - 2"

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, and ASTM F2098.


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* @ ^ ¢ ¥
 
PEX 0306
 
HeatLink
 
ASTM F876/F877
3/8" - 1 1/2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This barrier tubing product has been evaluated against the performance requirements of
  ASTM F876/F877. This product is not NSF Certified for use in a potable water
  distribution system. This product has been evaluated for use in radiant floor heating
  (NSF-rfh) applications only.
^ Available in black, orange and red.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.

Tubing* @ ^ ¢ ¥
 
PEX 5106
 
HeatLink
 
ASTM F876/F877
3/8" - 1 1/2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This barrier tubing product has been evaluated against the performance requirements of
  ASTM F876/F877. This product is not NSF Certified for use in a potable water
  distribution system. This product has been evaluated for use in radiant floor heating
  (NSF-rfh) applications only.
^ Available in black, orange and red.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.

Tubing* @ ^ ¢ ¥ [1]
 
PEX
 
HeatLink
 
CSA B137.5
3/8" - 1 1/2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This barrier tubing product has been evaluated against the performance requirements of
  ASTM F876/F877. This product is not NSF Certified for use in a potable water
  distribution system. This product has been evaluated for use in radiant floor heating
  (NSF-rfh) applications only.
^ Available in black, orange and red.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.



 
HeatLink Group 
3615 32 Street Northeast
Calgary, AB T1Y 5Y9 
Canada 
800-661-5332 
403-717-3820
Visit this company's website

Facility : A Sweden

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing# *
 
PEX 0006
 
HeatLink (Natural tubing with O2 barrier)
 
ASTM F876/F877
3/8", 1/2", 5/8", 3/4", 1", 1 1/4", 1 1/2", 2" SDR 9

# This barrier tubing product has been evaluated against the performance requirements of
  ASTM F876/F877.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.



 
HongYue Plastic Group Co., Ltd. DBA OnePlus Piping Systems Inc. 
#81, LongHai Road, Economic & Tech
Development Zone, Qinhuangdao City 
Heibei Province 066004 
China 
86 335 888 6666
Visit this company's website

Facility : Heibei Province, China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fittings[1]
 
PEX
 
 
ASTM F1960

One Plus PEX Ring
1/2" - 2"  

[1] PEX rings are non-wetted components of PEX fitting systems.

PEX Ring with Stop[1]
 
PEX
 
 
ASTM F1960
3/8" (ring38)   5/8" (ring58)   1/2" (ring12)   3/4" (ring34)  
1" (ring1)   1 1/4" (ring114)   1 1/2" (ring112)   2" (ring2)  

[1] PEX rings are non-wetted components of PEX fitting systems.

PEX Ring with Stop¢ [1]
 
PEX
 
 
CSA B137.5
3/4" (ring34)   2" (ring2)   1/2" (ring12)   1" (ring1)  
1 1/4" (ring114)   1 1/2" (ring112)   3/8" (ring38)   5/8" (ring58)  

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[1] PEX rings are non-wetted components of PEX fitting systems.

Pipe! § +++ [G]
 
PEX 5306
 
 
ASTM F876/F877
1/4" - 2"  

! Certified for natural,red, white and blue without oxygen barrier. 
  Natural - PEX 5006; Red, white, blue- PEX 5306
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! ¢ § +++ [2] [G]
 
PEX 5306
 
 
CSA B137.5
1/4" - 2"  

! Certified for natural,red, white and blue without oxygen barrier. 
  Natural - PEX 5006; Red, white, blue- PEX 5306
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Pipe Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159.	
    
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Fittings[1]
 
PEX
 
 
ASTM F1960

One Plus PEX Ring
1/2" - 2"  

[1] PEX rings are non-wetted components of PEX fitting systems.

PEX Ring with Stop[1]
 
PEX
 
 
ASTM F1960
1/2" (ring12)   2" (ring2)   3/4" (ring34)   3/8" (ring38)  
5/8" (ring58)   1 1/4" (ring114)   1 1/2" (ring112)   1" (ring1)  

[1] PEX rings are non-wetted components of PEX fitting systems.

PEX Ring with Stop[1]
 
PEX
 
 
CSA B137.5
5/8" (ring58)   1 1/2" (ring112)   1 1/4" (ring114)   1" (ring1)  
1/2" (ring12)   2" (ring2)   3/4" (ring34)   3/8" (ring38)  

[1] PEX rings are non-wetted components of PEX fitting systems.

Pipe! § +++ [G]
 
PEX 5306
 
 
ASTM F876/F877
1/4" - 2"  

! Certified for natural,red, white and blue without oxygen barrier.
  Natural - PEX 5006; Red, white, blue - PEX 5306.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! ¢ § +++ [2] [G]
 
PEX 5306
 
 
CSA B137.5
1/4" - 2"  

! Certified for natural,red, white and blue without oxygen barrier.
  Natural - PEX 5006; Red, white, blue - PEX 5306.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Pipe Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159.
    
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Huaru Pipe Inc 
116 Maple Street
Commerce, TX 75428 
United States 
315-418-0770

Facility : Commerce, TX

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing[1] [2]
 
PEX
 
Valtec
 
CAN/ULC S102.2
1/2"

[1] Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].
[2] Flame Spread Value (FSV) <= 25
    Smoke Developed Value (SDV) <= 50

Tubing[1] [3]
 
PEX
 
Valtec
 
ASTM E84
1/2"

[1] Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].
[3] Flame Spread Index <= 25
    Smoke Developed Index <=50


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe# § +++ [G]
 
PEX 5306
 
Valtec
 
ASTM F876/F877
1/2" - 1" SDR 9

# Tubing is solid wall, Red, White, or Blue.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# § +++ [G]
 
PEX 5306
 
Valtec
 
AWWA C904
1/2" - 1" SDR 9

# Tubing is solid wall, Red, White, or Blue.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# % ¢ § +++ [G]
 
PEX 5306
 
Valtec
 
CSA B137.5
1/2" - 1" SDR 9

# Tubing is solid wall, Red, White, or Blue.
% Tubing Certified against CSA B137.5 Shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2098, ASTM F2159 and ASSE 1061.
  
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe# §
 
PEX 5306
 
Valtec
 
ASTM F876/F877
1/2" - 1" SDR 9

# Tubing is solid wall, Red, White, or Blue.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# §
 
PEX 5306
 
Valtec
 
AWWA C904
1/2" - 1" SDR 9

# Tubing is solid wall, Red, White, or Blue.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# % §
 
PEX 5306
 
Valtec
 
CSA B137.5
1/2" - 1" SDR 9

# Tubing is solid wall, Red, White, or Blue.
% Tubing Certified against CSA B137.5 Shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2098, ASTM F2159 and ASSE 1061.
  
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


 
Infloor Sales & Service 
503 Gregg Drive
Buena Vista, CO 81211 
United States 
800-608-0562 
719-395-3400
Visit this company's website

Facility : Peculiar, MO

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing! % ^ §
 
PEX 5006
 
BPEX Tubing Oxygen Barrier
 
ASTM F876/F877
1/8" - 1"

! Product may or may not bear the NSF U.P. code marking.
% Certified product is orange or natural in color.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing% ^ ¢
 
PEX 5006
 
BPEX Tubing Oxygen Barrier
 
CSA B137.5
1/8" - 1"

% Certified product is orange or natural in color.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.



 
IPEX Incorporated 
3 Place Du Commerce, Suite 101
Île-Des-Soeurs 
Verdun, QC H3E 1H7 
Canada 
514-769-2200
Visit this company's website

Facility : L'Assomption, Québec, Canada

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe^ ¢ § ** +++ [G]
 
PEX 5106/5306
 
Blue 904
 
ASTM F876/F877
3/4" - 2" SDR 9

^ Meets the Chlorine Resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Certified Blue 904 tubing is blue in color.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe^ ¢ § ** +++ [G]
 
PEX 5306
 
Blue 904
 
AWWA C904
3/4" - 2" SDR 9

^ Meets the Chlorine Resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Certified Blue 904 tubing is blue in color.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe^ ¢ ** +++ [G]
 
PEX
 
Blue 904
 
CSA B137.5
3/4" - 2" SDR 9

^ Meets the Chlorine Resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
** Certified Blue 904 tubing is blue in color.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
John L Schultz Ltd. 
1723 55é Avenue
Dorval, QC H9P 2W3 
Canada 
800-363-6240

Facility : Guangdong, China

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ * [1] [2]
 
PEX
 
aqua-dynamic
 
ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] ASTM E84, 1/2'' - 2'' The Flame Spread Index and Smoke Developed Index for 1/2"-2"
    tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
    performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
    tubing is not insulated.
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50

Tubing$ & [2] [3]
 
PEX
 
aqua-dynamic
 
CAN/ULC S102.2
3/8", 1/2" - 2"

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] 3/8" Tubing (without insulation)
    Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
    1/2" through 2" Tubing (with insulation)
    Flame Spread Rating and Smoke Developed Classification based on when the tubing is field
    insulated with JM Microlok HP Hi Performance
    Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing
    shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[4] [5]
 
PEX
 
aqua-dynamic
 
ASTM E84
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].

Tubing[4] [6]
 
PEX
 
aqua-dynamic
 
CAN/ULC S102.2
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[7] [8]
 
PEX
 
aqua-dynamic
 
ASTM E84
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[8] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance	fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater than
    or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on
    minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM
    E84 FS<=25/SD<=50].

Tubing[7] [9]
 
PEX
 
aqua-dynamic
 
CAN/ULC S102.2
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[9] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions (all listed construction/color/size
    combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked
    [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[5] [10]
 
PEX
 
aqua-dynamic PEX-A
 
ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.		
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[6] [10]
 
PEX
 
aqua-dynamic PEX-A
 
CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.		
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[5] [11]
 
PEX
 
aqua-dynamic PEX-A
 
ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[11] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
     Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
     sizes only.  

Tubing[6] [11]
 
PEX
 
aqua-dynamic PEX-A
 
CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[11] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
     Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
     sizes only.  


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ ¢ § +++ [5] [G]
 
PEX
 
aqua-dynamic
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for natural, without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5006
 
aqua-dynamic
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
aqua-dynamic
 
ASTM F876/F877
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
aqua-dynamic
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[6]
 
aqua-dynamic PEX-A
 
ASTM F876/F877
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] PEX 5106 Certified for Red, Blue ,White 2-layer for  1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [5] [G]
 
PEX 5006
 
aqua-dynamic PEX-A
 
CSA B137.5
1/8" - 3"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [5] [G]
 
PEX 5106[6]
 
aqua-dynamic PEX-A
 
CSA B137.5
1/2", 5/8", 3/4", 1"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, F2098.
[6] PEX 5106 Certified for Red, Blue ,White 2-layer for  1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G]
 
PEX 5106[9]
 
aqua-dynamic
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[9] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8",3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
    5/8",3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [G]
 
PEX 5106[9]
 
aqua-dynamic
 
CSA B137.5
3/8" - 1"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[9] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8",3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
    5/8",3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

[4] This product represents the following configurations:
    Equal Straight Union, PF15c-S, 1/8" - 2 1/2"
    Equal Elbow, PF15c-L, 1/8" - 2 1/2"
    Equal Straight Union PF15c(II)-S, 1/8" - 2-1/2"
    Equal Elbow, PF15c(II)-L, 1/8" - 2-1/2"
[7] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5.  This is a non wetted product.
[8] n - Number of ports. 
    n - 4 - 8 for Branch Tees and n - 3 - 8 for Flow-through Tees.
    

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing& * ^ ~ ¢ +++ [G]
 
PEX 5106[7] [8]
 
aqua-dynamic
 
CSA B137.5

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  Certified
  for		
    red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  Certified for
  red,		
    white, blue, orange,natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[7] Certified for red and white PEX 5106 monowall pipe.
[8] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, ASTM F2098 and ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G]
 
PEX 5106[7]
 
aqua-dynamic
 
ASTM F876/F877
>= 1/8"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[7] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ¢ § [4]
 
PEX
 
aqua-dynamic
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.

Tubing$ * §
 
PEX 5006
 
aqua-dynamic
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5106
 
aqua-dynamic
 
ASTM F876/F877
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5106
 
aqua-dynamic
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5006
 
aqua-dynamic PEX-A
 
ASTM F876/F877
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  Certified
  for		
    red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  Certified for
  red,		
    white, blue, orange,natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[5]
 
aqua-dynamic PEX-A
 
ASTM F876/F877
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  Certified
  for		
    red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  Certified for
  red,		
    white, blue, orange,natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [4] [G]
 
PEX 5006
 
aqua-dynamic PEX-A
 
CSA B137.5
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  Certified
  for		
    red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  Certified for
  red,		
    white, blue, orange,natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[4] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [4] [G]
 
PEX 5106[5]
 
aqua-dynamic PEX-A
 
CSA B137.5
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  Certified
  for		
    red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  Certified for
  red,		
    white, blue, orange,natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[4] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.
[5] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G]
 
PEX 5106[6]
 
aqua-dynamic
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [G]
 
PEX 5106[6]
 
aqua-dynamic
 
CSA B137.5
3/8" - 1"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  Certified
  for		
    red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  Certified for
  red,		
    white, blue, orange,natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Jones Stephens Corp. 
3249 Moody Parkway
P.O. Box 580 
Moody, AL 35004 
United States 
800-355-6637
Visit this company's website

Facility : Barcelona, Spain

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
JONES STEPHENS
 
ASTM F876/F877
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes. 
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
JONES STEPHENS
 
CSA B137.5
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes. 
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* @ ¢ §
 
PEX 5106
 
JONES STEPHENS
 
ASTM F876/F877
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white and orange) are Certified for the following sizes: 3/8'', 1/2'',
  5/8'', 3/4'', 1'', 1-1/2'' & 2''.
  
  Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and ASTM F2098.
@ This tubing product has been evaluated against the performance requirements of
  ASTM	F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable
  water distribution system.  This product has been evaluated for use in radiant floor
  heating, (NSF-rfh), applications only.	
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* @ ¢ §
 
PEX 5106
 
JONES STEPHENS
 
CSA B137.5
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white and orange) are Certified for the following sizes: 3/8'', 1/2'',
  5/8'', 3/4'', 1'', 1-1/2'' & 2''.
  
  Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and ASTM F2098.
@ This tubing product has been evaluated against the performance requirements of
  ASTM	F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable
  water distribution system.  This product has been evaluated for use in radiant floor
  heating, (NSF-rfh), applications only.	
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
Jones Stephens Corp. 
3249 Moody Pkwy
Moody, AL 35004 
United States 
800-355-6637

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing* ¢ § +++ [1] [2]
 
PEX 5306
 
Jones Stephens
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[2] Certified for Red, Blue and White Colors.

Tubing* ¢ § +++ [1] [2]
 
PEX 5306
 
Jones Stephens
 
CSA B137.5
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[2] Certified for Red, Blue and White Colors.

Tubing* ¢ § +++ [1] [2]
 
PEX 5306
 
Jones Stephens
 
AWWA C904
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[2] Certified for Red, Blue and White Colors.



 
K-Flex USA, LLC 
100 K-Flex Way
Youngsville, NC 27596 
United States 
919-435-5538
Visit this company's website

Facility : Nuevo Leon, Mexico

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing* ^ ¢ +++ [1] [2] [G]
 
PEX 5306
 
K-FLEX PE-Xb Pipe
 
ASTM F876/F877
1/4" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for red, white, and blue colors.
[2] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F1960, ASTM F2098, and ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [1] [2] [G]
 
PEX 5306
 
K-FLEX PE-Xb Pipe
 
CSA B137.5
1/4" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for red, white, and blue colors.
[2] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F1960, ASTM F2098, and ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* ^ ¢ +++ [1] [2]
 
PEX 5306
 
K-FLEX PE-Xb Pipe
 
ASTM F876/F877
1/4" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for red, white, and blue colors.
[2] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F1960, ASTM F2098, and ASTM F2159.

Tubing* ^ ¢ +++ [1] [2]
 
PEX 5306
 
K-FLEX PE-Xb Pipe
 
CSA B137.5
1/4" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for red, white, and blue colors.
[2] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F1960, ASTM F2098, and ASTM F2159.

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


 
Kafrit NA Ltd. 
5411 - 275th Street
Langley, BC V4W 3X8 
Canada 
604-607-6730
Visit this company's website

Facility : Langley, British Columbia, Canada

Potable Water - Materials

Material Type End Use Trade Name Product Standard
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2410 CL Red N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2411 CL Blue N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2412 CL White N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2417 CL Black N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2418 CL Red N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2419 CL White N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2420 CL Natural N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2421 CL Light Blue N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2422 CL Purple N/A

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing manufactured using this material is cure process dependent.  Use of this material
    in NSF Certified tubing requires NSF's prior authorization.  Tubing produced from this
    material was tested to the performance requirements of ASTM F876 and CSA B137.5.  Tubing
    produced from this material is being evaluated for 1/4" and greater diameters.



 
Legend 
300 North Opdyke Road
Auburn Hills, MI 48326 
United States 
800-752-2082 
586-566-7400

Facility : D'Opaglio (NO), Italy

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe
 
PEX
 
LegendFlex
 
ASTM F876/F877
3/8" - 1"

Pipe
 
PEX
 
LegendFlex
 
CSA B137.5
3/8" - 1"



 
Legend Valve 
300 North Opdyke Road
Auburn Hills, MI 48326 
United States 
248-630-7437

Facility : Ulricehamn, Sweden

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * @
 
PEX
 
LegendFlex w/Oxygen Barrier
 
ASTM F876/F877
3/8", 1/2", 5/8", 3/4", 1", 1 1/4", 1 1/2", 2" SDR 9

$ Tubing tested as a system using Georg Fischer S.r.l. brass compression fittings which
  comply with ASTM F877.
*  Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877.  This product is not NSF Certified for use in a potable water distribution
  system.  This product has been evaluated for use in radiant floor heating, (NSF-rfh),
  applications only.		
  



 
Legend Valve 
300 North Opdyke Road
Auburn Hills, MI 48326 
United States 
248-630-7437
Visit this company's website

Facility : Barcelona, Spain

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
LegendFlex
 
ASTM F876/F877
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
LegendFlex
 
CSA B137.5
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe* @ ¢ §
 
PEX 5106
 
LegendFlex
 
ASTM F876/F877
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe* @ ¢ §
 
PEX 5106
 
LegendFlex
 
CSA B137.5
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
Leggett Supply Inc. DBA Flair-It Sales & Mobile Mart 
1701 South Cherokee
Muskogee, OK 74403 
United States 
918-681-2211

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX® Pro Blue UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX® Pro Blue UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX® Pro Red UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX® Pro Red UV-Shield
 
CSA B137.5

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX® Pro White UV-Shield
 
ASTM F876/F877

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX® Pro White UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

$ Non-barrier pipe.


 
Mercury Plastics LLC 
15760 Madison Road
P.O. Box 989 
Middlefield, OH 44062 
United States 
440-632-5281

Facility : Middlefield, OH

Potable Water - Appurtenances

Product Type   Material Type   Trade Name   Product Standard

Refrigerator Supply Line# ¢ § [1] [G]
 
PEX
 
GE SmartConnect™
 
ASME A112.18.6/CSA B125.6
1/4 in. OD Tube

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Certified up to 8 feet in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Refrigerator Supply Line# ¢ § [2] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/8" C.T.S.

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[2] Certified up to 6 feet in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tank Tube/Riser PW# ¢ § [3] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Certified up to 20" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Basin Tube/Riser PW# ¢ § [4] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Dishwasher Supply Line# ¢ § [5] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/4" CTS X 3/8" OD

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[5] Certified up to 72" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Univ Dishwash Supply Line# ¢ § [5] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/4" CTS X 3/8" OD

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[5] Certified up to 72" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Basin Tube/Riser PW# § [4] [G]
 
PEX
 
DURAPEX
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Basin Tube/Riser# ¢ [4] [6] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD - P2-XX-A
1/4" CTS x 3/8" OD - P2-XX-B

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Certified up to 96" in length.
[6] XX indicates length in inches.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Double Ended Hook-Up# ¢ [4] [6] [7] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
SEZ-XX-SB
SEZ-XX-ST

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Certified up to 96" in length.
[6] XX indicates length in inches.
[7] B indicates basin/lav end.
    T indicates closet/tank end.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

MEZ Double Ended Hook-Up# ¢ [4] [6] [8] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
MEZ-XX-PTW
MEZ-XX-PW9W
MEZ-XX-PW9W9
MEZ-XX-PWW

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Certified up to 96" in length.
[6] XX indicates length in inches.
[8] W9W denotes one 90-degree bend.
    W9W9 denotes two 90-degree bends.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tank Tube/Riser# ¢ [3] [6] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD - P2-XX-DL
1/4" CTS x 3/8" OD - P2-XX-T

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[3] Certified up to 20" in length.
[6] XX indicates length in inches.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Refrigerator Supply Line# ¢ § [2] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/8" C.T.S.

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[2] Certified up to 6 feet in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tank Tube/Riser PW# ¢ § [3] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Certified up to 20" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Basin Tube/Riser PW# ¢ § [4] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Dishwasher Supply Line# ¢ § [5] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[5] Certified up to 72" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Basin Tube/Riser# ¢ [4] [6] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD - P2-XX-A
1/4" CTS x 3/8" OD - P2-XX-B

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Certified up to 96" in length.
[6] XX indicates length in inches.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Double Ended Hook-Up# ¢ [6] [7] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
SEZ-XX-SB[4]

SEZ-XX-ST[3]

[4] Certified up to 96" in length.
[3] Certified up to 20" in length.
# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[6] XX indicates length in inches.
[7] B indicates basin/lav end.
    T indicates closet/tank end.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

MEZ Double Ended Hook-Up# ¢ [4] [6] [8] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
MEZ-XX-PTW
MEZ-XX-PW9W
MEZ-XX-PW9W9
MEZ-XX-PWW

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Certified up to 96" in length.
[6] XX indicates length in inches.
[8] W9W denotes one 90-degree bend.
    W9W9 denotes two 90-degree bends.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tank Tube/Riser# ¢ [3] [6] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD - P2-XX-DL
1/4" CTS x 3/8" OD - P2-XX-T

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[3] Certified up to 20" in length.
[6] XX indicates length in inches.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Supply Tube Assembly PW§ [4] [G]
 
PEX
 
AJ Hookup
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Supply Tube Assembly PW§ [4] [G]
 
PEX
 
DLJ Hookup
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Supply Tube Assembly PW§ [G]
 
PEX
 
MEZ Hookup
 
ASME A112.18.6/CSA B125.6
1/4"[4]

3/8"[9]

[4] Certified up to 96" in length.
[9] Certified up to 60" in length.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Supply Tube Assembly PW§ [4] [G]
 
PEX
 
SEZ Hookup
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing# @ ^ § +++ [G]
 
PEX 5106
 
Zurn®PEX
 
ASTM F876/F877
1/8" - 1 1/4" SDR 9

# Authorized for gray and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# & @ +++ [G]
 
PEX 5106
 
Zurn®PEX
 
CSA B137.5
1/8" - 1 1/4" SDR 9

# Authorized for gray and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# @ ^ § +++ [G]
 
PEX 5106
 
Merflex® PEX OT®
 
ASTM F876/F877
1/8" - 1 1/4" SDR 9

# Authorized for gray and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing@ ^ § +++ [G]
 
PEX 5106
 
Merflex® PEX OT®
 
ASTM F876/F877
1/8" CTS x 1/4" OD SDR 9

@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# & @ ¢ +++ [G]
 
PEX 5106
 
Merflex® PEX OT®
 
CSA B137.5
1/8" - 1 1/4" SDR 9

# Authorized for gray and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& @ ¢ +++ [G]
 
PEX 5106
 
Merflex® PEX OT®
 
CSA B137.5
1/8" CTS x 1/4" OD SDR 9

& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing# * @ ^ ¢ §
 
PEX 5006
 
Embassy/LiquiPEX w/O2 Barrier
 
ASTM F876/F877
3/8" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# & * @ ¢
 
PEX 5006
 
Embassy/LiquiPEX w/O2 Barrier
 
CSA B137.5
3/8" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.

Tubing# * @ ^ ¢ §
 
PEX 5006
 
Merflex® PEX OT® Oxygen Barrier
 
ASTM F876/F877
3/8" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# & * @ ¢
 
PEX 5006
 
Merflex® PEX OT® Oxygen Barrier
 
CSA B137.5
3/8" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.



 
MrPEX Systems  
14799 Jackal Street NW
Suite 100 
Ramsey, MN 55303 
United States 
612 810 0891

Facility : Barcelona, Spain

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
MrPEX
 
ASTM F876/F877
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2" sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 2" sizes.
  Tubing certified against CSA
  B137.5 shall include the standard designation(s) of the fitting system(s) for which the
  tubing is
  recommended by the manufacturer, and shall be marked, as applicable, with the following
  fitting system
  designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023. 
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
MrPEX
 
CSA B137.5
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2" sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 2" sizes.
  Tubing certified against CSA
  B137.5 shall include the standard designation(s) of the fitting system(s) for which the
  tubing is
  recommended by the manufacturer, and shall be marked, as applicable, with the following
  fitting system
  designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023. 
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Note: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* @ ¢ §
 
PEX 5106
 
MrPEX
 
ASTM F876/F877
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white
  and orange) are certified for the following sizes: 3/8", 1/2", 5/8", 3/4", 1", 1-1/4",
  1-1/2" & 2".
  
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s)
  for which the tubing is recommended by the manufacturer, and shall be marked, as
  applicable with the
  following fitting system designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM
  F2098.
  
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* @ ¢ §
 
PEX 5106
 
MrPEX
 
CSA B137.5
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white
  and orange) are certified for the following sizes: 3/8", 1/2", 5/8", 3/4", 1", 1-1/4",
  1-1/2" & 2".
  
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s)
  for which the tubing is recommended by the manufacturer, and shall be marked, as
  applicable with the
  following fitting system designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM
  F2098.
  
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
MrPEX Systems (a division of Safelink Systems, Inc.) 
14799 Jackal Street NW
Suite 100 
Ramsey, MN 55303 
United States 
800-716-3406 
952-440-7704

Facility : Ulricehamn, Sweden

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing§ ** [1]
 
PEX
 
Mr. PEX (3-layer and 4-layer Tubing)
 
ASTM E84

1/2", 5/8", 3/4"

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * @
 
PEX
 
Mr. PEX (Natural tubing)
 
ASTM F876/F877
3/8", 1/2", 5/8", 3/4", 1", 1 1/4", 1 1/2", 2" SDR 9

$ Tubing tested as a system using Georg Fischer S.r.l. brass compression fittings which
  comply with ASTM F877.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877.  This product is not NSF Certified for use in a potable water distribution
  system.  This product has been evaluated for use in radiant floor heating, (NSF-rfh),
  applications only.

Tubing# $ *
 
PEX
 
Mr. PEX (Red tubing with O2 barrier)
 
ASTM F876/F877
3/8", 1/2", 5/8", 3/4", 1", 1 1/4", 1 1/2", 2" SDR 9

# This barrier tubing product has been evaluated against the performance requirements of
  ASTM F876/F877.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
$ Tubing tested as a system using Georg Fischer S.r.l. brass compression fittings which
  comply with ASTM F877.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.

Tubing# $ *
 
PEX
 
Mr. PEX (Natural tubing with O2 barrier)
 
ASTM F876/F877
3/8", 1/2", 5/8", 3/4", 1", 1 1/4", 1 1/2", 2" SDR 9

# This barrier tubing product has been evaluated against the performance requirements of
  ASTM F876/F877.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
$ Tubing tested as a system using Georg Fischer S.r.l. brass compression fittings which
  comply with ASTM F877.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.



 
OnePlus New Material Technology Co., Ltd. 
Pou Thoeung Village, Bet Trang Commune
& Smach Deng Village, Ream Commune 
Prey Nob District, Sihanoukville Province 
Cambodia 
855 87 1357 3159

Facility : Prey Nob District, Cambodia

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe! § +++ [G]
 
PEX 5306
 
One Plus PEX
 
ASTM F876/F877
1/4" - 2"

! Certified for natural, red, white and blue without oxygen barrier. 
  Natural-PEX 5006; red, white, blue- PEX 5306
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! ¢ § +++ [1] [G]
 
PEX 5306
 
One Plus PEX
 
CSA B137.5
1/4" - 2"

! Certified for natural, red, white and blue without oxygen barrier. 
  Natural-PEX 5006; red, white, blue- PEX 5306
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Pipe Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Fittings[2]
 
PEX
 
One Plus PEX
 
ASTM F1960

One Plus PEX Ring with stop
3/8" - 3"  

[2] PEX rings are non-wetted components of PEX fitting systems.

Fittings[2]
 
PEX
 
One Plus PEX
 
CSA B137.5

One Plus PEX Ring with stop
3/8" - 3"  

[2] PEX rings are non-wetted components of PEX fitting systems.


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe! § +++ [G]
 
PEX 5306
 
One Plus PEX
 
ASTM F876/F877
1/4" - 2"

! ! Certified for natural,red, white and blue without oxygen barrier. 
  Natural-PEX 5006; red, white, blue- PEX 5306
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! ¢ § +++ [1] [G]
 
PEX 5306
 
One Plus PEX
 
CSA B137.5
1/4" - 2"

! ! Certified for natural,red, white and blue without oxygen barrier. 
  Natural-PEX 5006; red, white, blue- PEX 5306
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Pipe Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Fittings[2]
 
PEX
 
One Plus PEX
 
ASTM F1960

One Plus PEX Ring with stop
3/8" - 3"  

[2] PEX rings are non-wetted components of PEX fitting systems.

Fittings[2]
 
PEX
 
One Plus PEX
 
CSA B137.5

One Plus PEX Ring with stop
3/8" - 3"  

[2] PEX rings are non-wetted components of PEX fitting systems.



 
PEX GUY 
14710 Yorba Court
Chino, CA 91710 
United States 
877-235-6352 
909-606-0988

Facility : # 1 China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ § +++
 
PEX 5006
 
PEX GUY
 
ASTM F876/F877
3/8" - 1 1/4" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing$ * ¢ § +++
 
PEX
 
PEX GUY
 
CSA B137.5
3/8" - 1" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing& * ^ ~ ¢ +++ [G]
 
PEX 5106[1]
 
PEX GUY
 
CSA B137.5
>= 1/8"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[1]
 
PEX GUY
 
ASTM F876/F877
>= 1/8"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
PEX GUY
 
ASTM F876/F877
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
PEX GUY
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * §
 
PEX 5006
 
PEX GUY
 
ASTM F876/F877
3/8" - 1 1/4" SDR 9

$ Certified for red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * ¢ §
 
PEX
 
PEX GUY
 
CSA B137.5
3/8" - 1" SDR 9

$ Certified for red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5006
 
PEX GUY
 
ASTM F876/F877
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified
  for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
  Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
  sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [1] [G]
 
PEX 5006
 
PEX GUY
 
CSA B137.5
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified
  for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
  Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
  sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * §
 
PEX 5006
 
PEX GUY
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
PEX GUY 
14710 Yorba Court
Chino, CA 91710 
United States 
877-235-6352
Visit this company's website

Facility : # 1 European Union

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
ALPHA PEX GUY
 
ASTM F876/F877
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes. Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following
  fitting system designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106:  Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023. 
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
ALPHA PEX GUY
 
CSA B137.5
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes. Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 1" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following
  fitting system designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106:  Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023. 
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* @ ¢ §
 
PEX 5106
 
ALPHA PEX GUY
 
ASTM F876/F877
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue,white and orange) are certified for the following sizes: 3/8", 1/2", 5/8",
  3/4", 1", 1-1/2" & 2".
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and
  ASTM F2098.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* @ ¢ §
 
PEX 5106
 
ALPHA PEX GUY
 
CSA B137.5
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue,white and orange) are certified for the following sizes: 3/8", 1/2", 5/8",
  3/4", 1", 1-1/2" & 2".
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable with the following fitting system designation(s): ASTM F1960, ASTM
  F1807, ASTM F2159, and
  ASTM F2098.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
PEXhouse.com. Inc. 
68 Healey Road Unit 4 -5
Bolton, ON L7E 5A4 
Canada 
844-548-8739
Visit this company's website

Facility : # 1 China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing& * ^ ~ ¢ +++ [G]
 
PEX 5106[1]
 
VesiPEX PEX-B
 
CSA B137.5
>= 1/8"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G]
 
PEX 5106[1]
 
VesiPEX PEX-B
 
ASTM F876/F877
>= 1/8"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [2] [G]
 
PEX
 
VesiPEX PEX-B
 
CSA B137.5
>= 1/8" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
VesiPEX PEX-B
 
ASTM F876/F877
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.			
  Natural - 5006			
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
VesiPEX PEX-B
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.			
  Natural - 5006			
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[3]
 
VesiPEX PEX-A
 
ASTM F876/F877
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] PEX 5106 Certified for Red, Blue ,White 2-layer for  1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [2] [G]
 
PEX 5106[3]
 
VesiPEX PEX-A
 
CSA B137.5
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, F2098.
[3] PEX 5106 Certified for Red, Blue ,White 2-layer for  1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G]
 
PEX 5106[4]
 
VesiPEX PEX-B
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[4] Certified for the following:			
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8",3/4" & 1"			
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
    5/8",3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [G]
 
PEX 5106[4]
 
VesiPEX PEX-B
 
CSA B137.5
3/8" - 1"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[4] Certified for the following:			
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8",3/4" & 1"			
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
    5/8",3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

$ Certified for natural, orange, red, and white with oxygen barrier.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[1] [2]
 
VesiPEX PEX-B
 
CSA B137.5

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for red and white PEX 5106 monowall pipe.
[2] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, ASTM F2098 and ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G]
 
PEX 5106[1]
 
VesiPEX PEX-B
 
ASTM F876/F877
>= 1/8"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ¢ § [5]
 
PEX
 
VesiPEX PEX-B
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.

Tubing$ * §
 
PEX 5006
 
VesiPEX PEX-B
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5106
 
VesiPEX PEX-B
 
ASTM F876/F877
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.		
  Natural - 5006
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5106
 
VesiPEX PEX-B
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.		
  Natural - 5006
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5006
 
VesiPEX PEX-A
 
ASTM F876/F877
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[6]
 
VesiPEX PEX-A
 
ASTM F876/F877
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [5] [G]
 
PEX 5006
 
VesiPEX PEX-A
 
CSA B137.5
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [5] [G]
 
PEX 5106[6]
 
VesiPEX PEX-A
 
CSA B137.5
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.
[6] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G]
 
PEX 5106[7]
 
VesiPEX PEX-B
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[7] Certified for the following:			
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"			
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [G]
 
PEX 5106[7]
 
VesiPEX PEX-B
 
CSA B137.5
3/8" - 1"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[7] Certified for the following:			
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"			
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
REHAU Construction LLC 
1501 Edwards Ferry Road, N.E.
Leesburg, VA 20176 
United States 
800-247-9445 
703-777-5255
Visit this company's website

Facility : # 1 Germany

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing[3] [4]
 
PEX
 
Raupex® Red UV Shield
 
CAN/ULC S102.2
1/2" - 2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
    Fittings as per Rehau installation instructions. 
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing[3] [4]
 
PEX
 
Raupex® White UV Shield
 
CAN/ULC S102.2
1/2" - 2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
    Fittings as per Rehau installation instructions. 
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing* [1]
 
PEX
 
Municipex®
 
ASTM E84
3/4" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]
 
PEX
 
Municipex®
 
ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a   
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
    
    
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[2] [3]
 
PEX
 
Municipex®
 
CAN/ULC S102.2
3/4" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing* [1]
 
PEX
 
Raupex® O2 Barrier
 
ASTM E84
1/2" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing** [1]
 
PEX
 
Raupex® O2 Barrier
 
ASTM E84
<= 1/2"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
   
   
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[3]
 
PEX
 
Raupex® O2 Barrier
 
CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]
 
PEX
 
Raupex® O2 Barrier
 
CAN/ULC S102.2
5/8" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing* [1]
 
PEX
 
Raupex®
 
ASTM E84
1/2" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing** [1]
 
PEX
 
Raupex®
 
ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
   
   
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]
 
PEX
 
Raupex®
 
ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a   
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
    
    
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[3]
 
PEX
 
Raupex®
 
CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]
 
PEX
 
Raupex®
 
CAN/ULC S102.2
1/2" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing* [1]
 
PEX
 
Raupex® Blue UV Shield
 
ASTM E84
1/2" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing** [1]
 
PEX
 
Raupex® Blue UV Shield
 
ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
   
   
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]
 
PEX
 
Raupex® Blue UV Shield
 
ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a   
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
    
    
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[1] *****
 
PEX
 
Raupex® Blue UV Shield
 
ASTM E84
1/2" - 2"

[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
***** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
      with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
      Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
      marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[3]
 
PEX
 
Raupex® Blue UV Shield
 
CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]
 
PEX
 
Raupex® Blue UV Shield
 
CAN/ULC S102.2
1/2" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing* [1]
 
PEX
 
Raupex® Red UV Shield
 
ASTM E84
1/2" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[3] [4]
 
PEX
 
Raupex® Blue UV Shield
 
CAN/ULC S102.2
1/2" - 2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
    Fittings as per Rehau installation instructions. 
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing** [1]
 
PEX
 
Raupex® Red UV Shield
 
ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
   
   
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]
 
PEX
 
Raupex® Red UV Shield
 
ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a   
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
    
    
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[1] *****
 
PEX
 
Raupex® Red UV Shield
 
ASTM E84
1/2" - 2"

[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
***** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
      with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
      Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
      marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[3]
 
PEX
 
Raupex® Red UV Shield
 
CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]
 
PEX
 
Raupex® Red UV Shield
 
CAN/ULC S102.2
1/2" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing* [1]
 
PEX
 
Raupex® White UV Shield
 
ASTM E84
1/2" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing** [1]
 
PEX
 
Raupex® White UV Shield
 
ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
   
   
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]
 
PEX
 
Raupex® White UV Shield
 
ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a   
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
    
    
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[1] *****
 
PEX
 
Raupex® White UV Shield
 
ASTM E84
1/2" - 2"

[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
***** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
      with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
      Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
      marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[3]
 
PEX
 
Raupex® White UV Shield
 
CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]
 
PEX
 
Raupex® White UV Shield
 
CAN/ULC S102.2
1/2" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]
 
PEX
 
RAUGEO
 
CAN/ULC S102.2
1/2" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* ^ +++ [G]
 
PEX 3306
 
MUNICIPEX
 
ASTM F876/F877
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction,
  including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ +++ [G]
 
PEX 3306
 
MUNICIPEX
 
AWWA C904
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction,
  including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe& * ^ ¢ § +++ [G]
 
PEX
 
MUNICIPEX
 
CSA B137.5
1/2" - 2" SDR 9

& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): AWWA C800.
* Accepted by NSF for use in residential and commercial construction,
  including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 3306
 
RAUPEX® Blue UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction,
  including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe% * ^ ¢ § +++ [G]
 
PEX
 
RAUPEX® Blue UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction,
  including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 3306
 
RAUPEX Red UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction,
  including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe% * ^ ¢ § +++ [G]
 
PEX
 
RAUPEX Red UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction,
  including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 3306
 
RAUPEX White UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction,
  including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe% * ^ ¢ § +++ [G]
 
PEX
 
RAUPEX White UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction,
  including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe$ * ^ §
 
PEX 3006
 
RAUPEX®
 
ASTM F876/F877
3/8" - 2" SDR 9

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with 
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ % * §
 
PEX 3006
 
RAUPEX®
 
CSA B137.5
3/8" - 2" SDR 9

$ Non-barrier pipe.
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe* ¥
 
PEX 0306
 
Raupex Black UV Shield
 
ASTM F876/F877
3/8" - 2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.

Pipe% * ¢ ¥
 
PEX
 
Raupex Black UV Shield
 
CSA B137.5
3/8" - 2"

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.


Facility : # 7 USA

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing* [1]
 
PEX
 
Municipex®
 
ASTM E84
3/4" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]
 
PEX
 
Municipex®
 
ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[2] [3]
 
PEX
 
Municipex®
 
CAN/ULC S102.2
3/4" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing* [1]
 
PEX
 
Municipex® Reclaim
 
ASTM E84
3/4" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]
 
PEX
 
Municipex® Reclaim
 
ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[2] [3]
 
PEX
 
Municipex® Reclaim
 
CAN/ULC S102.2
3/4" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing** [1]
 
PEX
 
Raupex® O2 Barrier
 
ASTM E84
<= 1/2"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing* [1]
 
PEX
 
Raupex® O2 Barrier
 
ASTM E84
5/8" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[3]
 
PEX
 
Raupex® O2 Barrier
 
CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]
 
PEX
 
Raupex® O2 Barrier
 
CAN/ULC S102.2
5/8" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing** [1]
 
PEX
 
Raupex®
 
ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing* [1]
 
PEX
 
Raupex®
 
ASTM E84
5/8" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]
 
PEX
 
Raupex®
 
ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[3]
 
PEX
 
Raupex®
 
CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]
 
PEX
 
Raupex®
 
CAN/ULC S102.2
5/8" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing** [1]
 
PEX
 
Raupex® Blue UV Shield
 
ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing* [1]
 
PEX
 
Raupex® Blue UV Shield
 
ASTM E84
5/8" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]
 
PEX
 
Raupex® Blue UV Shield
 
ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[1] ****
 
PEX
 
Raupex® Blue UV Shield
 
ASTM E84
1/2" - 2"

[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
**** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
     with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
     Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
     marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[3]
 
PEX
 
Raupex® Blue UV Shield
 
CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]
 
PEX
 
Raupex® Blue UV Shield
 
CAN/ULC S102.2
5/8" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[3] [4]
 
PEX
 
Raupex® Blue UV Shield
 
CAN/ULC S102.2
1/2" - 2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
    Fittings as per Rehau installation instructions.
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing** [1]
 
PEX
 
Raupex® Red UV Shield
 
ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing* [1]
 
PEX
 
Raupex® Red UV Shield
 
ASTM E84
5/8" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]
 
PEX
 
Raupex® Red UV Shield
 
ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[1] ****
 
PEX
 
Raupex® Red UV Shield
 
ASTM E84
1/2" - 2"

[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
**** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
     with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
     Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
     marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[3]
 
PEX
 
Raupex® Red UV Shield
 
CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]
 
PEX
 
Raupex® Red UV Shield
 
CAN/ULC S102.2
5/8" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[3] [4]
 
PEX
 
Raupex® Red UV Shield
 
CAN/ULC S102.2
1/2" - 2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
    Fittings as per Rehau installation instructions.
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing** [1]
 
PEX
 
Raupex® White UV Shield
 
ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing* [1]
 
PEX
 
Raupex® White UV Shield
 
ASTM E84
5/8" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]
 
PEX
 
Raupex® White UV Shield
 
ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[1] ****
 
PEX
 
Raupex® White UV Shield
 
ASTM E84
1/2" - 2"

[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
**** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
     with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
     Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
     marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[3]
 
PEX
 
Raupex® White UV Shield
 
CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]
 
PEX
 
Raupex® White UV Shield
 
CAN/ULC S102.2
5/8" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[3] [4]
 
PEX
 
Raupex® White UV Shield
 
CAN/ULC S102.2
1/2" - 2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
    Fittings as per Rehau installation instructions.
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing[2] [3]
 
PEX
 
RAUGEO
 
CAN/ULC S102.2
3/4" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* ^ § +++ [G]
 
PEX 3306
 
MUNICIPEX
 
ASTM F876/F877
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 3306
 
MUNICIPEX
 
AWWA C904
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe% * ^ ¢ § +++ [G]
 
PEX
 
MUNICIPEX
 
CSA B137.5
3/4" - 2"

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ +++ [G]
 
PEX 3306
 
MUNICIPEX Protect
 
ASTM F876/F877
3/4" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ +++ [G]
 
PEX 3306
 
MUNICIPEX Protect
 
AWWA C904
3/4" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe% * ^ ¢ § +++ [G]
 
PEX
 
MUNICIPEX Protect
 
CSA B137.5
3/4" - 2" SDR 9

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 3306
 
RAUPEX® Blue UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe% * ^ ¢ § +++ [G]
 
PEX
 
RAUPEX® Blue UV-Shield
 
CSA B137.5
1/2" - 2" SDR 9
3/8" - 2"

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 5306
 
RAUPEX® Blue UV-Shield
 
ASTM F876/F877
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 3306
 
RAUPEX® Red UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe% * ^ ¢ § +++ [G]
 
PEX
 
RAUPEX® Red UV-Shield
 
CSA B137.5
1/2” - 2" SDR 9
3/8" - 2"

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 5306
 
RAUPEX® Red UV-Shield
 
ASTM F876/F877
1/2” - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 3306
 
RAUPEX® White UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe% * ^ ¢ § +++ [G]
 
PEX
 
RAUPEX® White UV-Shield
 
CSA B137.5
1/2” - 2" SDR 9
3/8" - 2"

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 5306
 
RAUPEX® White UV-Shield
 
ASTM F876/F877
1/2” - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Fittings¢ §
 
PEX
 
Rehau
 
ASTM F877

EVERLOC+Sleeves
3/8" (104815)   1/2" (104816)   5/8" (104817)   3/4" (104818)  
1" (104819)   1 1/4" (104820)   1 1/2" (104821)   2" (104822)  

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Fittings¢ §
 
PEX
 
Rehau
 
CSA B137.5

EVERLOC+Sleeves
3/8" (104815)   1/2" (104816)   5/8" (104817)   3/4" (104818)  
1" (104819)   1 1/4" (104820)   1 1/2" (104821)   2" (104822)  

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): AWWA C800.
@ Product is exempted from bearing NSF-pw marking.

Reclaimed Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

PEX Pipe§
 
PEX 3306
 
MUNICIPEX Reclaim
 
ASTM F876/F877
1/2" - 2"

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

PEX Pipe§
 
PEX 3306
 
MUNICIPEX Reclaim
 
AWWA C904
1/2" - 2"

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

PEX Pipe% ¢
 
PEX
 
MUNICIPEX Reclaim
 
CSA B137.5
1/2" - 2"

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as
  applicable, with the following fitting system designation(s): AWWA C800.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.


Sewer Main - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe
 
PEX 3306
 
MUNICIPEX Force Main
 
ASTM F876/F877
1" - 2"

Pipe% ¢
 
PEX
 
MUNICIPEX Force Main
 
CSA B137.5
1" - 2"

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer,  and shall be
  marked, as applicable, with the following fitting system designation(s): AWWA C800.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.


Geothermal Applications

Product Type   Material Type   Trade Name   Product Standard

Fittings¢
 
PEX
 
REHAU® Raugeo
 
CSA C448

U-Bend
1"   2"  

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.

Pipe^ ¢
 
PEX
 
REHAU® Raugeo
 
CSA C448
3/4" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.

Pipe% ^ ¢
 
PEX
 
REHAU® Raugeo
 
CSA B137.5
3/4" - 2"

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe$ * ^ §
 
PEX 3006
 
RAUPEX®
 
ASTM F876/F877
3/8" - 2" SDR 9

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ % * §
 
PEX
 
RAUPEX®
 
CSA B137.5
3/8" - 2" SDR 9

$ Non-barrier pipe.
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe* ¥
 
PEX 0306
 
Raupex Black UV Shield
 
ASTM F876/F877
3/8" - 2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.

Pipe* ¥
 
PEX 0006
 
Raupex Black UV Shield
 
ASTM F876/F877
3/8" - 2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.

Pipe% * ¢ ¥
 
PEX
 
Raupex Black UV Shield
 
CSA B137.5
3/8" - 2"

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.

Pipe
 
PEX 3206
 
RAUPEX O2 Barrier
 
SE 1091
10.1 mm x 1.1 mm


Facility : # 11 Switzerland

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe# * ^ § +++ [G]
 
PEX 3306
 
Municipex PI
 
ASTM F876/F877
1" - 2" SDR 9

# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# * ^ § +++ [G]
 
PEX 3306
 
Municipex PI
 
AWWA C904
1" - 2" SDR 9

# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# & * ^ ¢ § +++ [G]
 
PEX
 
Municipex PI
 
CSA B137.5
1" - 2" SDR 9

# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): AWWA C800.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# % * ^ ¢ § +++ [G]
 
PEX
 
Insulpex Blue UV Shield
 
CSA B137.5
1" - 2" SDR 9

# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# * ^ § +++ [G]
 
PEX 3306
 
Insulpex Blue UV Shield
 
ASTM F876/F877
1" - 2" SDR 9

# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# * ^ § +++ [G]
 
PEX 3306
 
Insulpex Red UV Shield
 
ASTM F876/F877
1" - 2" SDR 9

# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# % * ^ ¢ § +++ [G]
 
PEX
 
Insulpex Red UV Shield
 
CSA B137.5
1" - 2" SDR 9

# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# * ^ § +++ [G]
 
PEX 3306
 
Insulpex White UV Shield
 
ASTM F876/F877
1" - 2" SDR 9

# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# % * ^ ¢ § +++ [G]
 
PEX
 
Insulpex White UV Shield
 
CSA B137.5
1" - 2" SDR 9

# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F877,
  F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Rehau Construction LLC 
1501 Edwards Ferry Road
Leesburg, VA 20176 
United States 
703-777-5255

Facility : # 5 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fitting Components§
 
PEX
 
Rehau
 
ASTM F1960
1/2" Ring [499702]   3/4" Ring [499704]   3/8" Ring [499701]   5/8" Ring [499703]  
1" Ring [499705]   1 1/4" Ring [499706]   1 1/2" Ring [499707]   2" Ring [499708]  

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Fitting Components¢ §
 
PEX
 
Rehau
 
CSA B137.5
1/2" Ring [499702]   3/4" Ring [499704]   3/8" Ring [499701]   5/8" Ring [499703]  
1" Ring [499705]   1 1/4" Ring [499706]   1 1/2" Ring [499707]   2" Ring [499708]  

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
REHAU Construction, LLC 
1501 Edwards Ferry Road Northeast
Leesburg, VA 20176 
United States 
703-779-4001

Facility : # 2 China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

PEX Ring with Stop[1]
 
PEX
 
REHAU
 
ASTM F1960
PEX Reinforcing Ring, 1 1/2" 499707   PEX Reinforcing Ring, 1 1/4" 499706   PEX Reinforcing Ring, 1" 499705   PEX Reinforcing Ring, 1/2" 499702  
PEX Reinforcing Ring, 2" 499708   PEX Reinforcing Ring, 3/4" 499704   PEX Reinforcing Ring, 3/8 in. 499701   PEX Reinforcing Ring, 5/8" 499703  

[1] PEX rings are non-wetted components o fPEX fitting systems.

PEX Ring with Stop[1]
 
PEX
 
REHAU
 
CSA B137.5
PEX Reinforcing Ring, 1 1/2" 499707   PEX Reinforcing Ring, 1 1/4" 499706   PEX Reinforcing Ring, 1" 499705   PEX Reinforcing Ring, 1/2" 499702  
PEX Reinforcing Ring, 2" 499708   PEX Reinforcing Ring, 3/4" 499704   PEX Reinforcing Ring, 3/8" 499701   PEX Reinforcing Ring, 5/8" 499703  

[1] PEX rings are non-wetted components o fPEX fitting systems.


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

PEX Ring with Stop[1]
 
PEX
 
REHAU
 
ASTM F1960
PEX Reinforcing Ring, 1 1/2" 499707   PEX Reinforcing Ring, 1 1/4" 499706   PEX Reinforcing Ring, 1" 499705   PEX Reinforcing Ring, 1/2" 499702  
PEX Reinforcing Ring, 2" 499708   PEX Reinforcing Ring, 3/4" 499704   PEX Reinforcing Ring, 3/8" 499701   PEX Reinforcing Ring, 5/8" 499703  

[1] PEX rings are non-wetted components of PEX fitting systems.

PEX Ring with Stop[1]
 
PEX
 
REHAU
 
CSA B137.5
PEX Reinforcing Ring, 1 1/2" 499707   PEX Reinforcing Ring, 1 1/4" 499706   PEX Reinforcing Ring, 1" 499705   PEX Reinforcing Ring, 1/2" 499702  
PEX Reinforcing Ring, 2" 499708   PEX Reinforcing Ring, 3/4" 499704   PEX Reinforcing Ring, 3/8" 499701   PEX Reinforcing Ring, 5/8" 499703  

[1] PEX rings are non-wetted components of PEX fitting systems.



 
Reliance Worldwide / Cash Acme 
2400 7th Avenue Southwest
Cullman, AL 35055 
United States 
877-700-4242 
256-775-8184

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* ^ § +++ [G]
 
PEX 3306
 
SharkBite 2XL
 
ASTM F876/F877
1 1/4" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SharkBite 2XL
 
CSA B137.5
1 1/4" - 2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Reliance Worldwide Corporation 
2300 Defoor Hills Road NW
Atlanta, GA 30318 
United States 
770-863-4000
Visit this company's website

Facility : # 1 Canada

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
Sharkbite®
 
ASTM F876/F877
1/4" - 2" SDR 9

$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F. System components consist of tubing and/or fittings. To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing? @ ^ ~ § +++ [G]
 
PEX 5306
 
Sharkbite®
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ ? @ ^ ~ ¢ § +++ [1] [G]
 
PEX 5306
 
Sharkbite®
 
CSA B137.5
1/4" - 2" SDR 9

$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F. System components consist of tubing and/or fittings. To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing! $ % ^ ~ §
 
PEX 5006
 
SharkBite®
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in of
  180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with 
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including 
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! $ % ^ ~ ¢ § [1]
 
PEX 5006
 
SharkBite®
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in of
  180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with 
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including 
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.



 
Reliance Worldwide Corporation 
2300 Defoor Hills
Atlanta, GA 30318 
United States 
877-800-4242
Visit this company's website

Facility : # 1 China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fittings* [1]
 
PEX
 
SharkBite
 
ASTM F1960

RIFENG PEX Ring with Stop 3/8" - 2"
UA23102   UA23102A25   UA23102CA25   UA23102Z25  
UA23103   UA23103A25   UA23103CA25   UA23103Z25  
UA23104   UA23104A25   UA23104Z25  

* Model numbers listed are base part numbers. Saleable items may include an additional 1-8
  alpha/numeric characters after the base part number that indicated specific packaging
  configurations only.
[1] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted product.

Fittings* [1]
 
PEX
 
SharkBite
 
CSA B137.5

RIFENG PEX Ring with Stop 3/8" - 2"
UA23102   UA23102A25   UA23102CA25   UA23102Z25  
UA23103   UA23103A25   UA23103CA25   UA23103Z25  
UA23104   UA23104A25   UA23104Z25  

* Model numbers listed are base part numbers. Saleable items may include an additional 1-8
  alpha/numeric characters after the base part number that indicated specific packaging
  configurations only.
[1] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted product.


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Fittings* [1]
 
PEX
 
SharkBite
 
ASTM F1960

RIFENG PEX Ring with Stop 3/8" - 2"
UA23102   UA23102A25   UA23102CA25   UA23102Z25  
UA23103   UA23103A25   UA23103CA25   UA23103Z25  
UA23104   UA23104A25   UA23104Z25  

* Model numbers listed are base part numbers. Saleable items may include an additional 1-8
  alpha/numeric characters after the base part number that indicated specific packaging
  configurations only.
[1] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted product.

Fittings* [1]
 
PEX
 
SharkBite
 
CSA B137.5

RIFENG PEX Ring with Stop 3/8" - 2"
UA23102   UA23102A25   UA23102CA25   UA23102Z25  
UA23103   UA23103A25   UA23103CA25   UA23103Z25  
UA23104   UA23104A25   UA23104Z25  

* Model numbers listed are base part numbers. Saleable items may include an additional 1-8
  alpha/numeric characters after the base part number that indicated specific packaging
  configurations only.
[1] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted product.



 
RHT Radiant Heating Technologies 
P.O. Box 2270
Vashon, WA 98070 
United States 
206-274-4510

Facility : # 1 China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
RHT™
 
ASTM F876/F877
3/8" - 1" SDR 9

$ Certified for blue, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ¢ § +++ [G]
 
PEX
 
RHT™
 
CSA B137.5
3/8" - 1" SDR 9

$ Certified for blue, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ @ §
 
PEX 5006
 
RHT™
 
ASTM F876/F877
3/8" - 1"

$ Certified for red with oxygen barrier.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ @ ¢ §
 
PEX
 
RHT™
 
CSA B137.5
3/8" - 1"

$ Certified for red with oxygen barrier.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
Rifeng Enterprise (Foshan) Co., Ltd. 
5th/F, Rifeng Building
16 Zumiao Road 
Foshan, Guangdong 528000 
China 
86 757 8230 1768

Facility : Foshan, China

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ * [2] [10]
 
PEX
 
Rifeng
 
ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[10] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2"
     tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
     performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
     tubing is not insulated.

Tubing$ & [2] [11]
 
PEX
 
Rifeng
 
CAN/ULC S102.2
3/8", 1/2" - 2"

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[11] 3/8" Tubing (without insulation)
     Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
     1/2" through 2" Tubing (with insulation)
     Flame Spread Rating and Smoke Developed Classification based on when the tubing is field
     insulated with JM Microlok HP Hi Performance
     Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing
     shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[1] [3]
 
PEX
 
RIFENG PEX
 
ASTM E84
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[1] Certified for red and white PEX 5106 monowall pipe.
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].

Tubing[1] [4]
 
PEX
 
RIFENG PEX
 
CAN/ULC S102.2
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[1] Certified for red and white PEX 5106 monowall pipe.
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[5] [6]
 
PEX
 
RIFENG PEX
 
ASTM E84
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[6] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance	fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater than
    or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on
    minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM
    E84 FS<=25/SD<=50].

Tubing[5] [7]
 
PEX
 
RIFENG PEX
 
CAN/ULC S102.2
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[7] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions (all listed construction/color/size
    combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked
    [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[3] [8]
 
PEX
 
RIFENG PEXa
 
ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[8] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.		
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[4] [8]
 
PEX
 
RIFENG PEXa
 
CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[8] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.		
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[3] [9]
 
PEX
 
RIFENG PEXa
 
ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[9] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
    Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
    sizes only.  

Tubing[4] [9]
 
PEX
 
RIFENG PEXa
 
CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[9] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
    Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
    sizes only.  


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fittings[7]
 
PEX
 
RIFENG
 
ASTM F1960

RIFENG PEX Ring with Stop
3/8" - 2"  

[7] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5.  This is a non wetted product.

Fittings[7]
 
PEX
 
RIFENG
 
CSA B137.5

RIFENG PEX Ring with Stop
3/8" - 2"  

[7] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5.  This is a non wetted product.

Tubing$ * ^ ¢ § +++ [5] [G]
 
PEX
 
Rifeng
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for natural, without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5006
 
RIFENG
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
RIFENG
 
ASTM F876/F877
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
RIFENG
 
AWWA C904
1/2" - 1 1/2" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
RIFENG
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5206
 
RIFENG
 
ASTM F876/F877
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5206
 
RIFENG
 
AWWA C904
1/2" - 1 1/2" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5206
 
RIFENG
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [6] [G]
 
PEX 5106
 
RIFENG PEXa
 
ASTM F876/F877
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] Certified for the following:
    1. Monowall pipe [PEX 5106]: 1/8" - 3"
    2. 2-layer skinned pipe for Red, Blue, White [PEX 5106]: 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G] [12]
 
PEX 5206
 
RIFENG PEXa
 
ASTM F876/F877
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[12] PEX 5206 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.

Tubing* ^ ~ ¢ +++ [G] [13]
 
PEX 5306
 
RIFENG PEXa
 
ASTM F876/F877
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[13] PEX 5306 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.

Tubing& * ^ ~ ¢ +++ [5] [G]
 
PEX 5006
 
RIFENG PEXa
 
CSA B137.5
1/8" - 3"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [5] [6] [G]
 
PEX 5106
 
RIFENG PEXa
 
CSA B137.5
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2098.
[6] Certified for the following:
    1. Monowall pipe [PEX 5106]: 1/8" - 3"
    2. 2-layer skinned pipe for Red, Blue, White [PEX 5106]: 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [5] [G] [12]
 
PEX 5206
 
RIFENG PEXa
 
CSA B137.5
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[12] PEX 5206 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.

Tubing* ^ ¢ +++ [5] [G] [13]
 
PEX 5306
 
RIFENG PEXa
 
CSA B137.5
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[13] PEX 5306 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.

Tubing* ^ ¢ +++ [9] [G]
 
PEX 5106
 
RIFENG PEX
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[9] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8",3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
    5/8",3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G] [11]
 
PEX 5106
 
RIFENG PEX
 
ASTM F876/F877
>= 1/8"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[11] Certified for red and white PEX 5106 monowall pipe.

Tubing* ^ ¢ +++ [9] [G]
 
PEX 5306
 
RIFENG PEX
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[9] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8",3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
    5/8",3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [9] [G]
 
PEX 5106
 
RIFENG PEX
 
CSA B137.5
3/8" - 1"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[9] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8",3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
    5/8",3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [G] [11]
 
PEX 5106
 
RIFENG PEX
 
CSA B137.5
>= 1/8"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[11] Certified for red and white PEX 5106 monowall pipe.

Tubing& * ^ ¢ +++ [9] [G] [10]
 
PEX 5306
 
RIFENG PEX
 
CSA B137.5
3/8" - 1"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[9] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8",3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
    5/8",3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[10] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
     fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
     marked with the following fitting system designations:  ASTM F1807, ASTM F2159.


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Fittings[7]
 
PEX
 
RIFENG
 
ASTM F1960

RIFENG PEX Ring with Stop
3/8" - 2"  

[7] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5.  This is a non wetted product.

Fittings[7]
 
PEX
 
RIFENG
 
CSA B137.5

RIFENG PEX Ring with Stop
3/8" - 2"  

[7] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5.  This is a non wetted product.

Tubing$ * ¢ § [5]
 
PEX
 
Rifeng
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, ASTM F2098.

Tubing$ * §
 
PEX 5006
 
Rifeng
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5106
 
RIFENG
 
ASTM F876/F877
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5106
 
RIFENG
 
AWWA C904
1/2" - 1 1/2" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5106
 
RIFENG
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5206
 
Rifeng
 
ASTM F876/F877
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5206
 
Rifeng
 
AWWA C904
1/2" - 1 1/2" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5206
 
Rifeng
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5006
 
RIFENG PEXa
 
ASTM F876/F877
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [6] [G]
 
PEX 5106
 
RIFENG PEXa
 
ASTM F876/F877
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] Certified for the following:
    1. Monowall pipe [PEX 5006/PEX 5106]: 1/8"- 3"
    2. 2-layer skinned pipe for Red, Blue, White [PEX 5006/PEX 5106]: 1/2", 5/8", 3/4", 1"
    sizes only
    3. 3-Layer barrier pipe [PEX 5006/PEX 5106]: 1/2", 5/8", 3/4", 1" sizes only
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G] [12]
 
PEX 5206
 
RIFENG PEXa
 
ASTM F876/F877
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[12] PEX 5206 Certified for Red, Blue, White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.

Tubing* ^ ¢ +++ [G] [13]
 
PEX 5306
 
RIFENG PEXa
 
ASTM F876/F877
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[13] PEX 5306 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.

Tubing* ^ ~ ¢ +++ [5] [G]
 
PEX 5006
 
RIFENG PEXa
 
CSA B137.5
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, ASTM F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [6] [G] [14]
 
PEX 5106
 
RIFENG PEXa
 
CSA B137.5
1/8" - 3"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] Certified for the following:
    1. Monowall pipe [PEX 5006/PEX 5106]: 1/8"- 3"
    2. 2-layer skinned pipe for Red, Blue, White [PEX 5006/PEX 5106]: 1/2", 5/8", 3/4", 1"
    sizes only
    3. 3-Layer barrier pipe [PEX 5006/PEX 5106]: 1/2", 5/8", 3/4", 1" sizes only
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[14] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
     fitting system(s) for which the tubing is recommended by the manufacturer and shall be
     marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
     F1960, ASTM F2098.

Tubing* ^ ¢ +++ [G] [12] [14]
 
PEX 5206
 
RIFENG PEXa
 
CSA B137.5
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[12] PEX 5206 Certified for Red, Blue, White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[14] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
     fitting system(s) for which the tubing is recommended by the manufacturer and shall be
     marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
     F1960, ASTM F2098.

Tubing* ^ ¢ +++ [G] [13] [14]
 
PEX 5306
 
RIFENG PEXa
 
CSA B137.5
1/2", 5/8", 3/4", 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[13] PEX 5306 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[14] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
     fitting system(s) for which the tubing is recommended by the manufacturer and shall be
     marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
     F1960, ASTM F2098.

Tubing* ^ ¢ +++ [8] [G]
 
PEX 5106
 
RIFENG PEX
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[8] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G] [10]
 
PEX 5106
 
RIFENG PEX
 
ASTM F876/F877
>= 1/8"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[10] Certified for red and white PEX 5106 monowall pipe.

Tubing* ^ ¢ +++ [8] [G]
 
PEX 5306
 
RIFENG PEX
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[8] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [8] [G]
 
PEX 5106
 
RIFENG PEX
 
CSA B137.5
3/8" - 1"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[8] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [G] [10] [11]
 
PEX 5106
 
RIFENG PEX
 
CSA B137.5

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[10] Certified for red and white PEX 5106 monowall pipe.
[11] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
     fitting system(s) for which the tubing is recommended by the manufacturer and shall be
     marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
     F1960, ASTM F2080, ASTM F2098, ASSE 1061.

Tubing& * ^ ~ ¢ +++ [8] [9] [G]
 
PEX 5306
 
RIFENG PEX
 
CSA B137.5
3/8" - 1"

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[8] Certified for the following:
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[9] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Riifo North America 
4737 Smokey Bear Lane
Columbia Falls, MT 59912 
United States 
406-250-4412

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ *
 
PEX
 
Riifo
 
ASTM E84

3/8", 1/2" - 2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing$ &
 
PEX
 
Riifo
 
CAN/ULC S102.2

3/8", 1/2" - 2"
Flame Spread Rating <= 25   Smoke Developed Classification <= 50  

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fittings[7]
 
PEX
 
RIIFO
 
ASTM F1960

RIFENG PEX Ring with Stop
3/8" - 2"  

[7] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5.  This is a non wetted product.

Fittings[7]
 
PEX
 
RIIFO
 
CSA B137.5

RIFENG PEX Ring with Stop
3/8" - 2"  

[7] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5.  This is a non wetted product.

Tubing$ * ^ ¢ § +++ [G]
 
PEX
 
Riifo
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
Riifo
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5006
 
RIIFO PEXa
 
ASTM F876/F877
1/8" - 3"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5006[6]
 
RIIFO PEXa
 
ASTM F876/F877
1/2", 5/8", 3/4", 1"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [5] [G]
 
PEX 5006
 
RIIFO PEXa
 
CSA B137.5
1/8" - 3"  

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [5] [G]
 
PEX 5006[6]
 
RIIFO PEXa
 
CSA B137.5
1/2", 5/8", 3/4", 1"  

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, F2098.
[6] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5006/5206
 
RIIFO
 
ASTM F876/F877
1/8" -6" SDR 9

! Certified for red, white and blue without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Fittings[7]
 
PEX
 
RIIFO
 
ASTM F1960

RIFENG PEX Ring with Stop
3/8" - 2"  

[7] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5.  This is a non wetted product.

Fittings[7]
 
PEX
 
RIIFO
 
CSA B137.5

RIFENG PEX Ring with Stop
3/8" - 2"  

[7] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5.  This is a non wetted product.

Tubing$ * ¢ §
 
PEX
 
Riifo
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * §
 
PEX 5006
 
Riifo
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! * ^ §
 
PEX 5206
 
RIIFO
 
ASTM F876/F877
1/8" - 6" SDR 9

! Certified for red, white and blue without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5006
 
RIIFO PEXa
 
ASTM F876/F877
1/8" - 3"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. 
  Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
  Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
  sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ §
 
PEX 5206
 
RIIFO
 
CSA B137.5
1/8" - 6" SDR 9

! Certified for red, white and blue without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* ^ ~ ¢ +++ [5] [G]
 
PEX 5006
 
RIIFO PEXa
 
CSA B137.5
1/8" - 3"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. 
  Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
  Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
  sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[6]
 
RIIFO PEXa
 
ASTM F876/F877
1/2", 5/8", 3/4", 1"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. 
  Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
  Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
  sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [5] [G]
 
PEX 5106[6]
 
RIIFO PEXa
 
CSA B137.5
1/2", 5/8", 3/4", 1"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. 
  Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
  Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
  sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations:  ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.
[6] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
SACO AEI Polymers, Inc. 
3220 Crocker Avenue
Sheboygan, WI 53081 
United States 
920-803-0778
Visit this company's website

Facility : Sheboygan, WI

Potable Water - Materials

Material Type End Use Trade Name Product Standard
PEX 5006$ * +++ 1 Pexidan® L/T (Natural) N/A
PEX 5106$ * +++ 1 Pexidan L/T (Red, White, and Blue) N/A
PEX 5306$ * +++ 1 Pexidan® L/T Eclipse™ Black N/A
PEX 5306# $ ^ 1 Pexidan® L/T Eclipse™ (Red, White, and Blue) N/A
PEX 5206$ * +++ 1 Pexidan® L/T-UV N/A
PEX 5306$ * +++ 1 Pexidan® L/T-UV (Blue) N/A
PEX 5206$ * +++ 1 Pexidan® L/T-UV (Red and White) N/A
PEX 5306$ * +++ 1 Pexidan® L/T-UV (Red and White) N/A

# Potable water tubing made with Pexidan® L/T Eclipse (Blue, Red, and White) consists of
  two-layered coextruded tube, having a black inner layer and a colored, outer skin layer.
   Pexidan® L/T Eclipse (Blue, Red, and White) is not a certified material for solid wall
  tubing or as a water contact material.
$ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
* Tubing manufactured using this material is cure process dependent.  Use of this material
  in NSF Certified tubing requires NSF's prior authorization and transfer of the PPI
  hydrostatic design basis from the Plastics Pipe Institute (PPI).  Tubing produced from
  this material was tested to the health effects requirements of NSF/ANSI/CAN 61, the
  performance requirements of ASTM F876/F877, and the performance requirements of CSA
  B137.5.  This material has been qualified for use in tubing at 1/4" and greater
  diameters.
^ Tubing manufactured using this material is cure process dependent.  Use of this material
  in NSF Certified tubing requires NSF's prior authorization.  Coextruded tubing produced
  using this material as the outer skin layer was tested to the performance requirements
  as ASTM F876/F877.  This material has been qualified for use in tubing at 1/4" and
  greater diameters.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).



 
Safelink Systems, Inc. DBA MrPEX Systems 
14799 Jackal Street NW
Suite 100 
Ramsey, MN 55303 
United States 
800-716-3406 
952-652-2472
Visit this company's website

Facility : # 1

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing^ § **
 
PEX
 
Mr Pex® Potable
 
ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <= 50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing! * ¢ § ++ [G]
 
PEX 5106, PEX 5306
 
Mr Pex® Potable
 
ASTM F876/F877
3/8" - 2"

! Certified for red, blue and natural colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ¢ § ++ [G]
 
PEX 5106, PEX 5306
 
Mr Pex® Potable
 
CSA B137.5
3/8" - 2"

! Certified for red, blue and natural colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Shandong Efield Piping System Co., Ltd. 
No. 2369 Yikang Road
Tengzhou, Shandong 277500 
China 
86 632 599 0659
Visit this company's website

Facility : Shandong, China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe# & ¢ § +++ [G]
 
PEX 5006
 
EFIELD PEX Tubing
 
CSA B137.5
3/8" - 1"

# Certified for blue, white and red without oxygen barrier.
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked with the following fitting system designations:  ASTM F2159.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# & ¢ § +++ [G]
 
PEX 5306
 
EFIELD PEX Tubing
 
ASTM F876/877
3/8" - 1"

# Certified for blue, white and red without oxygen barrier.
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked with the following fitting system designations:  ASTM F2159.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# & ¢ § +++ [G]
 
PEX 5306
 
EFIELD PEX Tubing
 
CSA B137.5
3/8" - 1"

# Certified for blue, white and red without oxygen barrier.
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked with the following fitting system designations:  ASTM F2159.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe$ & ¢ § +++ [G]
 
PEX 5006
 
EFIELD PEX Barrier Tubing
 
ASTM F876/F877
3/8" - 1"

$ Certified for blue, white and red.
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked with the following fitting system designations:  ASTM F2159.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe$ & ¢ § +++ [G]
 
PEX 5006
 
EFIELD PEX Barrier Tubing
 
CSA B137.5
3/8" - 1"

$ Certified for blue, white and red.
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked with the following fitting system designations:  ASTM F2159.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Silon s.r.o. 
Prumyslová 451
Sezimovo Ústí 2 
391 02 
Czech Republic 
420 381621111
Visit this company's website

Facility : Peachtree City, GA

Potable Water - Materials

Material Type End Use Trade Name Product Standard
PEX 5306^ ++ [1] 1 TA 1108HD/TA2410 CL Red N/A
PEX 5306^ ++ [1] 1 TA 1108HD/TA2411 CL Blue N/A
PEX 5306^ ++ [1] 1 TA 1108HD/TA2412 CL White N/A

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[1] Tubing manufactured using this material is cure process dependent.  Use of this material
    in NSF Certified tubing requires NSF's prior authorization.  Tubing produced from this
    material was tested to the performance requirements of ASTM F876 and CSA B137.5.


Radiant Floor Heating - Materials

Material Type End Use Trade Name Product Standard
PEX 0306[1] 1 TA 1108HD/TA2411 CL Blue N/A
PEX 0306[1] 1 TA 1108HD/TA2410 CL Red N/A
PEX 0306[1] 1 TA 1108HD/TA2412 CL White N/A

[1] Tubing manufactured using this material is cure process dependent. Use of this material
    in NSF Certified tubing requires NSF's prior authorization.  Tubing produced from this
    material was tested to the performance requirements of ASTM F876 and CSA B137.5.

NSF Certified materials and generic ingredients are exempt from bearing an NSF Certification Mark. Certified materials and generic ingredients are identified by the manufacturer name, facility location, and trade designation as shown in the Official Listing.


Facility : Sezimovo Ústí, Czech Republic

Potable Water - Materials

Material Type End Use Trade Name Product Standard
PEX 5306^ ++ [1] 1 TA 1108HD/TA2411 CL Blue N/A
PEX 5306^ ++ [1] 1 TA 1108HD/TA2410 CL Red N/A
PEX 5306^ ++ [1] 1 TA 1108HD/TA2412 CL White N/A

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[1] Tubing manufactured using this material is cure process dependent. Use of this material
    in NSF Certified tubing requires NSF's prior authorization. Tubing produced from this
    material was tested to the performance requirements of ASTM F876 and CSA B137.5.



 
Sioux Chief Manufacturing Company, Inc. 
24110 South Peculiar Drive
Peculiar, MO 64078 
United States 
800-821-3944 
816-779-6104

Facility : Peculiar, MO

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe! @ ^ ¢ § +++ [G]
 
PEX 5306
 
PowerPEX
 
ASTM F876/F877
1/8" - 2" SDR 9

! Product may or may not bear the NSF U.P. code marking.
@ Product available in red, white, blue or natural.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe& @ ^ ¢ +++ [G]
 
PEX 5306
 
PowerPEX
 
CSA B137.5
1/8" - 2" SDR 9

& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2080, ASTM F1960, and ASSE 1061.
@ Product available in red, white, blue or natural.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe! @ ^ ¢ § +++ [G]
 
PEX 5306
 
PowerPEX
 
AWWA C904
1/2" – 1 1/2" SDR 9

! Product may or may not bear the NSF U.P. code marking.
@ Product available in red, white, blue or natural.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe
 
PEX 5006
 
PowerPEX O2 Barrier
 
ASTM F876/F877
1/2" - 2" SDR 9

Pipe& ¢
 
PEX
 
PowerPEX O2 Barrier
 
CSA B137.5
1/2" - 2" SDR 9

& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2080, ASTM F1960, and ASSE 1061.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.

Tubing! % ^ §
 
PEX 5006
 
PowerPEX O2 Barrier
 
ASTM F876/F877
1/8" - 1" SDR 9

! Product may or may not bear the NSF U.P. code marking.
% Certified product is orange or natural in color.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing% & ^ ¢
 
PEX 5006
 
PowerPEX O2 Barrier
 
CSA B137.5
1/8" - 1" SDR 9

% Certified product is orange or natural in color.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2080, ASTM F1960, and ASSE 1061.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.



 
Sioux Chief Manufacturing, Inc. 
24110 South Peculiar Drive
Peculiar, MO 64078 
United States 
800-779-6104 
816-779-6104

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fitting Components§
 
PEX
 
 
ASTM F1960
1/2" Ring (649W2)   3/4" Ring (649W3)   1" Ring (649W4)  

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Fitting Components§
 
PEX
 
 
CSA B137.5
1/2" Ring (649W2)   3/4" Ring (649W3)   1" Ring (649W4)  

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
Sioux Chief Manufacturing, Inc. 
24110 South Peculiar Drive
Peculiar, MO 64078 
United States 
800-779-6104 
816-779-6104

Facility : # 3 Canada

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing% * ^ ¢ § ++ [G]
 
PEX 5106
 
SIOUX CHIEF PowerPEX BARRIER
 
ASTM F876/F877
1/4" - 2" SDR 9

% Certified SIOUX CHIEF PowerPEX BARRIER tubing has a red outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing% ¢ ++ [G]
 
PEX
 
SIOUX CHIEF PowerPEX BARRIER
 
CSA B137.5
1/4" - 2" SDR 9

% Certified SIOUX CHIEF PowerPEX BARRIER tubing has a red outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing% * ^ ¢ §
 
PEX 5106
 
SIOUX CHIEF PowerPEX BARRIER
 
ASTM F876/F877
1/4" - 2" SDR 9

% Certified SIOUX CHIEF PowerPEX BARRIER tubing has a red outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing% ¢
 
PEX
 
SIOUX CHIEF PowerPEX BARRIER
 
CSA B137.5
1/4" - 2" SDR 9

% Certified SIOUX CHIEF PowerPEX BARRIER tubing has a red outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.



 
Sioux Chief Manufacturing, Inc. 
24110 South Peculiar Drive
Peculiar, MO 64078 
United States 
800-779-6104 
816-779-6104

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* ^ § +++ [G]
 
PEX 3306
 
PowerPEX Blue
 
ASTM F876/F877
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
  
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
PowerPEX Blue
 
CSA B137.5
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
  
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § [G]
 
PEX 3006
 
PowerPEX Red
 
ASTM F876/F877
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
  
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
PowerPEX Red
 
CSA B137.5
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
  
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 3306
 
PowerPEX White
 
ASTM F876/F877
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
  
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
PowerPEX White
 
CSA B137.5
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
  
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Stream 33 Products, LLC 
2620 Ridgewood Road
Akron, OH 44313 
United States 
330-762-9621
Visit this company's website

Facility : Guangdong, China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fittings[1]
 
PEX
 
Stream33
 
ASTM F1960

PEX Ring with Stop
3/8" - 2"  

[1] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted product.

Fittings[1]
 
PEX
 
Stream33
 
CSA B137.5

PEX Ring with Stop
3/8" - 2"  

[1] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted product.



 
Stream33 Products, LLC 
2620 Ridgewood Road
Akron, OH 44313 
United States 
330-475-8231
Visit this company's website

Facility : Peculiar, MO

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe! @ ^ ¢ § +++ [G]
 
PEX 5306
 
STREAM33
 
ASTM F876/F877
1/2" - 2" SDR 9

! Product may or may not bear the NSF U.P. code Marking.
@ Product available in red, white, or blue.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe@ ^ ¢ § +++ [G]
 
PEX 5306
 
STREAM33
 
CSA B137.5
1/2" - 2" SDR 9

@ Product available in red, white, or blue.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe! @ ^ ¢ § +++ [G]
 
PEX 5306
 
STEAM33
 
AWWA C904
1/2" – 1 1/2" SDR 9

! Product may or may not bear the NSF U.P. code Marking.
@ Product available in red, white, or blue.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Stream33 Products, LLC 
2620 Ridgewood Road
Akron, OH 44313 
United States 
800-362-9532 
330-762-9621

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* ^ § +++ [G]
 
PEX 3306
 
Stream33 Blue PEX-a
 
ASTM F876/F877
1/2" - 1" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe% * ^ ¢ § +++ [G]
 
PEX
 
Stream33 Blue PEX-a
 
CSA B137.5
1/2" - 1" SDR 9

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM
  F877,F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 3306
 
Stream33 Red PEX-a
 
ASTM F876/F877
1/2" - 1" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe% * ^ ¢ § +++ [G]
 
PEX
 
Stream33 Red PEX-a
 
CSA B137.5
1/2" - 1" SDR 9

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM
  F877,F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 3306
 
Stream33 White PEX-a
 
ASTM F876/F877
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe% * ^ ¢ § +++ [G]
 
PEX
 
Stream33 White PEX-a
 
CSA B137.5
1/2" - 2" SDR 9

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s):  ASTM
  F877,F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
The Boys, LLC dba SupplyHouse.com 
130 Spagnoli Road
Melville, NY 11747 
United States 
631-393-2855

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ *
 
PEX
 
Bluefin
 
ASTM E84

3/8", 1/2" - 2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing$ &
 
PEX
 
Bluefin
 
CAN/ULC S102.2

3/8", 1/2" - 2"
Flame Spread Rating <= 25   Smoke Developed Classification <= 50  

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD
  <=50].
  1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index
  based on when the tubing is field insulated with JM Microlok HP Hi Performance
  Fiberglass insulation as per the pipe manufacturer's installation instructions.
  Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
Bluefin
 
ASTM F876/F877
>=1/8" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ ¢ § +++ [G]
 
PEX
 
Bluefin
 
CSA B137.5
>=1/8" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ¢ §
 
PEX
 
Bluefin
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * §
 
PEX 5006
 
Bluefin
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
The Mosack Group, Inc. 
701 Matthews-Mint Hill Road
Matthews, NC 28105 
United States 
704-847-9191

Facility : Foshan, China

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ * ^ § +++ [G]
 
PEX
 
Apollo/TMG/PurePEX/PureLink
 
ASTM E84

3/8", 1/2" - 2"[1]
WPPB2012   WPPB2034   WPPR2012   WPPW2034  
WPPW201   WPPW2012   WPPR2034  

68PXB100012 1/2"
Flame Spread Index <= 25   Flame Spread Index <= 25  

68PXB100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB1210 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB3410 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR1210 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR3410 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW5012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW5034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW51 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW538 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ & § +++ [G]
 
PEX
 
Apollo/TMG/PurePEX/PureLink
 
CAN/ULC S102.2

3/8", 1/2" - 2"[1]
WPPB2034   WPPR2012   WPPR2034   WPPW201  
WPPB2012   WPPW2034   WPPW2012  

68PXB100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB10012 1/2"
Flame Spread Rating <= 25   Smoke Developed Classification <= 50  

APPB10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB1210 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB3410 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR1210 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR3410 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW5012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW5034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW51 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW538 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

>= 1/8" SDR 9
APPB1001 1"   APPB10012 1/2"   APPB10034 3/4"   APPB1210 1/2"  
APPB2012 1/2"   APPB2034 3/4"   APPB3001 1"   APPB30012 1/2"  
APPB30034 3/4"   APPB3410 3/4"   APPB50012 1/2"   APPB50034 3/4"  
APPR1001 1"   APPR10012 1/2"   APPR10034 3/4"   APPR1210 1/2"  
APPR2012 1/2"   APPR2034 3/4"   APPR3001 1"   APPR30012 1/2"  
APPR30034 3/4"   APPR3410 3/4"   APPR50012 1/2"   APPR50034 3/4"  
APPW1001 1"   APPW10012 1/2"   APPW10034 3/4"   APPW1012 1/2"  
APPW1034 3/4"   APPW2012 1/2"   APPW2034 3/4"   APPW3001 1"  
APPW30012 1/2"   APPW30034 3/4"   APPW50012 1/2"   APPW50034 3/4"  
APPW51 1"   APPW512 1/2"   APPW514 1/4"   APPW534 3/4"  
APPW538 3/8"  

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ ¢ § +++ [G]
 
PEX 5006
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

>= 1/8" SDR 9
APPB1001 1"   APPB10012 1/2"   APPB10034 3/4"   APPB1210 1/2"  
APPB2012 1/2"   APPB2034 3/4"   APPB3001 1"   APPB30012 1/2"  
APPB30034 3/4"   APPB3410 3/4"   APPB50012 1/2"   APPB50034 3/4"  
APPR1001 1"   APPR10012 1/2"   APPR10034 3/4"   APPR1210 1/2"  
APPR2012 1/2"   APPR2034 3/4"   APPR3001 1"   APPR30012 1/2"  
APPR30034 3/4"   APPR3410 3/4"   APPR50012 1/2"   APPR50034 3/4"  
APPW1001 1"   APPW10012 1/2"   APPW10034 3/4"   APPW1012 1/2"  
APPW1034 3/4"   APPW2012 1/2"   APPW2034 3/4"   APPW3001 1"  
APPW30012 1/2"   APPW30034 3/4"   APPW50012 1/2"   APPW50034 3/4"  
APPW51 1"   APPW512 1/2"   APPW514 1/4"   APPW534 3/4"  
APPW538 3/8"  

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * § +++ [G]
 
PEX 5006
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877
68PXB100012 1/2"   68PXB100038 3/8"   68PXB1001 1"   68PXB10012 1/2"  
68PXB10034 3/4"   68PXB10038 3/8"   68PXB1012 1/2"   68PXB1034 3/4"  
68PXB201 1"   68PXB2012 1/2"   68PXB2034 3/4"   68PXB3001 1"  
68PXB30012 1/2"   68PXB30034 3/4"   68PXB5001 1"   68PXB50012 1/2"  
68PXB50034 3/4"   68PXB50038 3/8"   68PXR100012 1/2"   68PXR100038 3/8"  
68PXR1001 1"   68PXR10012 1/2"   68PXR10034 3/4"   68PXR10038 3/8"  
68PXR1012 1/2"   68PXR1034 3/4"   68PXR201 1"   68PXR2012 1/2"  
68PXR2034 3/4"   68PXR3001 1"   68PXR30012 1/2"   68PXR30034 3/4"  
68PXR5001 1"   68PXR50012 1/2"   68PXR50034 3/4"   68PXR50038 3/8"  
68PXW100012 1/2"   68PXW100038 3/8"   68PXW1001 1"   68PXW10012 1/2"  
68PXW10034 3/4"   68PXW10038 3/8"   68PXW1012 1/2"   68PXW1034 3/4"  
68PXW201 1"   68PXW2012 1/2"   68PXW2034 3/4"   68PXW3001 1"  
68PXW30012 1/2"   68PXW30034 3/4"   68PXW5001 1"   68PXW50012 1/2"  
68PXW50034 3/4"   68PXW50038 3/8"   APPB101 1"   APPB1210 1/2"  
APPB212 1/2"   APPB234 3/4"   APPB3410 3/4"   APPB512 1/2"  
APPB534 3/4"   APPR1210 1/2"   APPR212 1/2"   APPR234 3/4"  
APPR3410 3/4"   APPR512 1/2"   APPR534 3/4"   APPW101 1"  
APPW1038 3/8"   APPW14RISER 1/4"   APPW201 1"   APPW212 1/2"  
APPW234 3/4"   APPW2512 1/2"   APPW2534 3/4"   APPW5012 1/2"  
APPW5034 3/4"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# § +++ [G]
 
PEX 5006
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5
68PXB100012 1/2"   68PXB100038 3/8"   68PXB1001 1"   68PXB10012 1/2"  
68PXB10034 3/4"   68PXB10038 3/8"   68PXB1012 1/2"   68PXB1034 3/4"  
68PXB201 1"   68PXB2012 1/2"   68PXB2034 3/4"   68PXB3001 1"  
68PXB30012 1/2"   68PXB30034 3/4"   68PXB5001 1"   68PXB50012 1/2"  
68PXB50034 3/4"   68PXB50038 3/8"   68PXR100012 1/2"   68PXR100038 3/8"  
68PXR1001 1"   68PXR10012 1/2"   68PXR10034 3/4"   68PXR10038 3/8"  
68PXR1012 1/2"   68PXR1034 3/4"   68PXR201 1"   68PXR2012 1/2"  
68PXR2034 3/4"   68PXR3001 1"   68PXR30012 1/2"   68PXR30034 3/4"  
68PXR5001 1"   68PXR50012 1/2"   68PXR50034 3/4"   68PXR50038 3/8"  
68PXW100012 1/2"   68PXW100038 3/8"   68PXW1001 1"   68PXW10012 1/2"  
68PXW10034 3/4"   68PXW10038 3/8"   68PXW1012 1/2"   68PXW1034 3/4"  
68PXW201 1"   68PXW2012 1/2"   68PXW2034 3/4"   68PXW3001 1"  
68PXW30012 1/2"   68PXW30034 3/4"   68PXW5001 1"   68PXW50012 1/2"  
68PXW50034 3/4"   68PXW50038 3/8"   APPB101 1"   APPB1210 1/2"  
APPB212 1/2"   APPB234 3/4"   APPB3410 3/4"   APPB512 1/2"  
APPB534 3/4"   APPR1210 1/2"   APPR212 1/2"   APPR234 3/4"  
APPR3410 3/4"   APPR512 1/2"   APPR534 3/4"   APPW101 1"  
APPW1038 3/8"   APPW14RISER 1/4"   APPW201 1"   APPW212 1/2"  
APPW234 3/4"   APPW2512 1/2"   APPW2534 3/4"   APPW5012 1/2"  
APPW5034 3/4"  

# Certified for black, blue, natural, orange, red, and white.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! $ * ^ +++ [G]
 
PEX 5106
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

1/8" - 6" SDR 9
WPPB2012   WPPB2034   WPPR2012   WPPR2034  
WPPW201   WPPW2012   WPPW2034  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [1] [G]
 
PEX 5106[2]
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

1/2", 5/8", 3/4", 1"
EPPB1012S   EPPB1034S   EPPB2012S   EPPB2034S  
EPPB30034S   EPPR10034S   EPPR1012S   EPPR1034S  
EPPR2012S   EPPR2034S   EPPR30012S   EPPR30034S  
EPPW1001   EPPW10012   EPPW10034   EPPW101  
EPPW1012   EPPW1034   EPPW201   EPPW2012  
EPPW2034   EPPW30012   EPPW30034   EPPW50034  
EPPW51   EPPW512   EPPW534   WEPPW5001  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.
[2] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [G]
 
PEX 5106[3]
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

3/8" - 1"
WPPB2012   WPPB2034   WPPR2012   WPPR2034  
WPPW201   WPPW2012   WPPW2034  

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance
  with ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Certified for the following:  			
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"			
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& * ^ ~ ¢ +++ [4] [G]
 
PEX 5306[3]
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

3/8" - 1"
WPPB2012   WPPB2034   WPPR2012   WPPR2034  
WPPW201   WPPW2012   WPPW2034  

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance
  with ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Certified for the following:  			
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"			
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[4] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ § +++ [G]
 
PEX 5106
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

1/8" - 6" SDR 9
WPPB2012   WPPB2034   WPPR2012   WPPR2034  
WPPW201   WPPW2012   WPPW2034  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ ~ ¢ +++ [G]
 
PEX 5106[5]
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

1/2", 5/8", 3/4", 1"
EPPB1012S   EPPB1034S   EPPB2012S   EPPB2034S  
EPPB30034S   EPPR10034S   EPPR1012S   EPPR1034S  
EPPR2012S   EPPR2034S   EPPR30012S   EPPR30034S  
EPPW1001   EPPW10012   EPPW10034   EPPW101  
EPPW1012   EPPW1034   EPPW201   EPPW2012  
EPPW2034   EPPW30012   EPPW30034   EPPW50034  
EPPW51   EPPW512   EPPW534   WEPPW5001  

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ ¢ +++ [G]
 
PEX 5106[4]
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

3/8" - 1"
WPPB2012   WPPB2034   WPPR2012   WPPR2034  
WPPW201   WPPW2012   WPPW2034  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[4] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ¢ +++ [G]
 
PEX 5306[4]
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[4] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

[6] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * §
 
PEX 5006
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

>= 1/8" SDR 9
APPOB2512 1/2"   APPOB30012 1/2"   APPOB10034 3/4"   APPOB30034 3/4"  

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * ¢ §
 
PEX 5006
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

>= 1/8" SDR 9
APPOB2512 1/2"   APPOB30012 1/2"   APPOB10034 3/4"   APPOB30034 3/4"  

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# * § +++
 
PEX 5006
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877
APPOB10012 1/2"   68PXPOB30012 1/2"   68PXPOB50012 1/2"   68PXPOB100012 1/2"  
APPOB1034 3/4"   68PXPOB30034 3/4"   68PXPOB50034 3/4"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing# * § +++
 
PEX 5006
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

1/8" - 3"
EPPR1034S   EPPR1012S   EPPR2034S   EPPR30012S  
EPPR30034S   EPPW1001   EPPW10012   EPPW10034  
EPPW101   EPPW1012   EPPW1034   EPPW201  
EPPW2012   EPPW2034   EPPW30012   EPPW30034  
EPPW50034   EPPW51   EPPW512   EPPW534  
WEPPW5001   EPPB1012S   EPPB1034S   EPPB2012S  
EPPB2034S   EPPB30034S   EPPR10034S   EPPR2012S  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing# * § +++
 
PEX 5006
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5
APPOB10012 1/2"   68PXPOB30012 1/2"   68PXPOB50012 1/2"   68PXPOB100012 1/2"  
APPOB1034 3/4"   68PXPOB30034 3/4"   68PXPOB50034 3/4"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing# * § +++ [6]
 
PEX 5006
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

1/8" - 3"
EPPR1034S   EPPR2012S   EPPR2034S   WEPPW5001  
EPPR30034S   EPPW1001   EPPW10012   EPPW10034  
EPPW101   EPPW1012   EPPW1034   EPPW201  
EPPW2012   EPPW2034   EPPW30012   EPPW30034  
EPPW50034   EPPW51   EPPW512   EPPW534  
EPPR1012S   EPPR10034S   EPPB30034S   EPPB2034S  
EPPB2012S   EPPB1034S   EPPB1012S   EPPR30012S  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.

Tubing! * ^ §
 
PEX 5106
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

1/8" - 6" SDR 9
WPPB2012   WPPB2034   WPPR2012   WPPW2034  
WPPW201   WPPW2012   WPPR2034  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* ^ ¢ +++ [G]
 
PEX 5106[3]
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

3/8" - 1"
WPPB2012   WPPB2034   WPPR2012   WPPW2034  
WPPW201   WPPW2012   WPPR2034  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Certified for the following:  			
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"			
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[5]
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

1/2", 5/8", 3/4", 1"
EPPW2034   EPPW30012   EPPW30034   EPPW50034  
EPPW51   EPPW512   EPPW534   WEPPW5001  
EPPB2012S   EPPB2034S   EPPB30034S   EPPR10034S  
EPPR1012S   EPPR1034S   EPPR2012S   EPPR2034S  
EPPR30012S   EPPR30034S   EPPW1001   EPPW10012  
EPPW10034   EPPW101   EPPW1012   EPPW1034  
EPPW201   EPPW2012   EPPB1012S   EPPB1034S  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ §
 
PEX 5106
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

1/8" - 6" SDR 9
WPPW2034   WPPB2012   WPPB2034   WPPR2012  
WPPR2034   WPPW201   WPPW2012  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing& * ^ ~ ¢ +++ [G]
 
PEX 5106[3]
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

3/8" - 1"
WPPW2034   WPPB2012   WPPB2034   WPPR2012  
WPPR2034   WPPW201   WPPW2012  

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance
  with ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Certified for the following:  			
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"			
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[5]
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

1/2", 5/8", 3/4", 1"
EPPW101   EPPW1012   EPPW1034   EPPW201  
EPPW2012   EPPW2034   EPPW30012   EPPW30034  
EPPW50034   EPPW51   EPPW512   EPPW534  
WEPPW5001   EPPW10034   EPPB1012S   EPPW10012  
EPPW1001   EPPR30034S   EPPR30012S   EPPR2034S  
EPPR2012S   EPPR1034S   EPPR1012S   EPPR10034S  
EPPB30034S   EPPB2034S   EPPB1034S   EPPB2012S  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.
[2] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[4] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159.


 
The Mosack Group, Inc. 
11210 Allen Station Drive
Mint Hill, NC 28227 
United States 
704-841-6167

Facility : # 1 China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
ASTM F1960
EPXS3810PK
EPXS3850PK
EPXS38100JR
EPXS3850JR
EPXS38100PK
EPXS3825PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
ASTM F1960
EPXS310PK
EPXS35PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
ASTM F1960
EPXS21210PK
EPXS2125PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
ASTM F1960
EPXS25PK
EPXS210PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
ASTM F1960
EPXS11215PK
EPXS11210PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
ASTM F1960
EPXS1145PK
EPXS11410PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
ASTM F1960
EPXS125PK
EPXS1100PK
EPXS150JR
EPXS110PK
EPXS1100JR
EPXS150PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
ASTM F1960
EPXS3450PK
EPXS34100JR
EPXS3450JR
EPXS3410PK
EPXS34100PK
EPXS3425PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
ASTM F1960
EPXS5825PK
EPXS5810PK
EPXS5850PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
ASTM F1960
EPXS1210PK
EPXS1225PK
EPXS12100JR
EPXS1250PK
EPXS12100PK
EPXS1250JR

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
CSA B137.5
EPXS38100PK
EPXS3850PK
EPXS3810PK
EPXS3825PK
EPXS38100JR
EPXS3850JR

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
CSA B137.5
EPXS1210PK
EPXS1250PK
EPXS12100JR
EPXS1250JR
EPXS12100PK
EPXS1225PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
CSA B137.5
EPXS5810PK
EPXS5825PK
EPXS5850PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
CSA B137.5
EPXS34100PK
EPXS3425PK
EPXS3410PK
EPXS3450PK
EPXS34100JR
EPXS3450JR

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
CSA B137.5
EPXS1100PK
EPXS110PK
EPXS125PK
EPXS150JR
EPXS1100JR
EPXS150PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
CSA B137.5
EPXS11410PK
EPXS1145PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
CSA B137.5
EPXS11210PK
EPXS11215PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
CSA B137.5
EPXS210PK
EPXS25PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
CSA B137.5
EPXS2125PK
EPXS21210PK

Pinch Clamp
 
PEX
 
TMG/PEX TMG
 
CSA B137.5
EPXS35PK
EPXS310PK



 
The Mosack Group, Inc. 
11210 Allen Station Drive
Mint Hill, NC 28227 
United States 
888-229-2874

Facility : Mint Hill, NC

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing^ § **
 
PEX
 
Apollo
 
ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <=50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing! * ^ ~ ¢ § ++ [G]
 
PEX 5106/5306
 
Apollo
 
ASTM F876/F877
3/8" - 2"

! Certified for blue, natural, red colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Pipe may have a blue, red or white coating.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ ~ ¢ § ++ [1] [G]
 
PEX 5106/5306
 
Apollo
 
CSA B137.5
3/8" - 2"

! Certified for blue, natural, red colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Pipe may have a blue, red or white coating.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ¢ § +++ [1] [2] [G]
 
PEX 5306
 
Apollo
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[2] Certified for Red, Blue and White Colors.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ¢ § +++ [1] [2] [G]
 
PEX 5306
 
Apollo
 
CSA B137.5
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[2] Certified for Red, Blue and White Colors.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* ¢ § +++ [1] [2] [G]
 
PEX 5306
 
Apollo
 
AWWA C904
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098, and ASSE 1061.
[2] Certified for Red, Blue and White Colors.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Facility : Calgary, Alberta, Canada

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing^ § **
 
PEX
 
Apollo
 
ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <=50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing! * ^ ~ ¢ § ++ [G]
 
PEX 5106/5306
 
Apollo
 
ASTM F876/F877
3/8" - 2"

! Certified for blue, natural, red colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Pipe may have a blue, red or white coating.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ^ ~ ¢ § ++ [1] [G]
 
PEX 5106/5306
 
Apollo
 
CSA B137.5
3/8" - 2"

! Certified for blue, natural, red colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Pipe may have a blue, red or white coating.
~ Pipe may utilize blue, red, or black colored ink on the printline.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, ASTM F2098 and ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
The Mosack Group, LLC 
701 Matthews-Mint Hill Road
Matthews, NC 28105 
United States 
888-229-2874 
704-841-6167
Visit this company's website

Facility : # 8 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe% & * ^ ¢ § +++ [G]
 
PEX 3306
 
Apollo
 
ASTM F876/F877
1/2" - 2" SDR 9

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F877,
  F1807, F1960, F2080 and F2159.
  
  
& Product can be Red, White or Blue.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe% & * ^ ¢ § +++ [G]
 
PEX 3006
 
Apollo
 
CSA B137.5
1/2" - 2" SDR 9

% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F877,
  F1807, F1960, F2080 and F2159.
  
  
& Product can be Red, White or Blue.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
The Mosack Group,Inc 
701 Matthews Mint Hill ROAd
Matthews, NC 28105 
United States 
704-479-6584
Visit this company's website

Facility : Heibei Province, China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

PEX Ring with Stop
 
PEX
 
TMG
 
ASTM F1960
EPXS1225PK   EPXS125PK   EPXS3425PK  

[1] 

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

PEX Ring with Stop
 
PEX
 
TMG
 
ASTM F1960
EPXS1225PK   EPXS125PK   EPXS3425PK  

[1] 


 
Tribal Manufacturing, Inc. 
450 Leggitt Road
Marshall, MI 49068 
United States 
269-781-3901
Visit this company's website

Facility : Marshall, MI

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fitting Components§
 
PEX
 
 
ASTM F1960
3/8" Ring (F300N3)   1/2" Ring (F300N4)   5/8" Ring (F300N5)   3/4" Ring (F300N6)  
1" Ring (F300N8)   1 1/4" Ring (F300N10)   1 1/2" Ring (F300N12)   2" Ring (F300N16)  

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Fitting Components§
 
PEX
 
 
CSA B137.5
3/8" Ring (F300N3)   1/2" Ring (F300N4)   5/8" Ring (F300N5)   3/4" Ring (F300N6)  
1" Ring (F300N8)   1 1/4" Ring (F300N10)   1 1/2" Ring (F300N12)   2" Ring (F300N16)  

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Fitting Components§
 
PEX
 
Failsafe
 
ASTM F1960
1/2" Ring (F300N4)   3/4" Ring (F300N6)   1" Ring (F300N8)  

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Fitting Components§
 
PEX
 
Failsafe
 
CSA B137.5
1/2" Ring (F300N4)   3/4" Ring (F300N6)   1" Ring (F300N8)  

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

*** These components require additional processing in order to be used in a
    piping system.  The use of these components in NSF Certified fittings
    require written authorization from NSF.


 
Uponor 
5925 148th Street West
Apple Valley, MN 55124 
United States 
800-321-4739 
952-891-2000
Visit this company's website

Facility : Apple Valley, MN

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* ^ ¢ § +++ [3] [5] [G]
 
PEX 5106
 
AquaPEX (Natural)
 
ASTM F876/F877
1/4" - 3" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Product may or may not bear the U.P. Code mark.
[5] May also use the trade names AquaPEX Natural, AquaPEX White, or AquaPEX Clear. 
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ +++ [2] [5] [G]
 
PEX 5106
 
AquaPEX (Natural)
 
CSA B137.5
1/4" - 3" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASSE 1061 (3/8"
    - 2" only), ASTM F1960, ASTM F1807, and ASTM F2098.
[5] May also use the trade names AquaPEX Natural, AquaPEX White, or AquaPEX Clear. 
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [3] [4] [G]
 
PEX 5306
 
AquaPEX (Red or Blue)
 
ASTM F876/F877
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Product may or may not bear the U.P. Code mark.
[4] Pipe may be marked PEX 5306, PEX 5206, or PEX 5106.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ +++ [1] [4] [G]
 
PEX 5306
 
AquaPEX (Red or Blue)
 
CSA B137.5
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASSE 1061 (1/2"
    - 2" only), ASTM F1960, ASTM F1807, and ASTM F2098.
[4] Pipe may be marked PEX 5306, PEX 5206, or PEX 5106.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe^ ¢ § ** +++ [3] [6] [G]
 
PEX 5106
 
ResiPEX™ (Natural)
 
ASTM F876/F877
1/2" - 1" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Accepted by NSF for use in residential construction, including manufactured housing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Product may or may not bear the U.P. Code mark.
[6] May also use the trade names ResiPEX Natural, ResiPEX White, or ResiPEX Clear. 
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe^ ¢ ** +++ [1] [6] [G]
 
PEX 5106
 
ResiPEX™ (Natural)
 
CSA B137.5
1/2" - 1" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
** Accepted by NSF for use in residential construction, including manufactured housing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASSE 1061 (1/2"
    - 2" only), ASTM F1960, ASTM F1807, and ASTM F2098.
[6] May also use the trade names ResiPEX Natural, ResiPEX White, or ResiPEX Clear. 
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [3] [G]
 
PEX 5106
 
hePEX
 
ASTM F876/F877
5/16" - 4" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Product may or may not bear the U.P. Code mark.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ +++ [2] [G]
 
PEX 5106
 
hePEX
 
CSA B137.5
5/16" - 4" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASSE 1061 (3/8"
    - 2" only), ASTM F1960, ASTM F1807, and ASTM F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Reinforcing Rings¢ [7] [8]
 
PEX
 
Uponor Logo
 
ASTM F1960

ProPEX Ring
3/8" (Q4690302)  

ProPEX Ring with Stop
1/2" (Q4690512)   5/8" (Q4690625)   3/4" (Q4690756)   1" (Q4691000)  
1 1/4" (Q4691250)   1 1/2" (Q4691500)   2" (Q4692000)   2 1/2" (Q4692500)  
3" (Q4693000)  

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[7] Product does not have water contact.
[8] Specifically for use with Uponor fittings.

Reinforcing Rings¢ [7] [8]
 
PEX
 
Uponor Logo
 
CSA B137.5

ProPEX Ring
3/8" (Q4690302)  

ProPEX Ring with Stop
5/8" (Q4690625)   3/4" (Q4690756)   3" (Q4693000)   2" (Q4692000)  
2 1/2" (Q4692500)   1/2" (Q4690512)   1" (Q4691000)   1 1/4" (Q4691250)  
1 1/2" (Q4691500)  

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[7] Product does not have water contact.
[8] Specifically for use with Uponor fittings.


Reclaimed Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing* ¢ [1] [2]
 
PEX 5106
 
AquaPEX Reclaimed Water
 
ASTM F876/F877
1/2" - 4" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[1] This product is intended for reclaimed water end use, and is marked "not for potable
    water" or "nonpotable water". This product has an outer purple coating.
[2] Product meets the most current dimensional requirements of ASTM F876.

Tubing* ¢ [1] [3] [4]
 
PEX
 
AquaPEX Reclaimed Water
 
CSA B137.5
1/2" - 4" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[1] This product is intended for reclaimed water end use, and is marked "not for potable
    water" or "nonpotable water". This product has an outer purple coating.
[3] Product meets applicable requirements of CSA B128.1.  Listing does not preclude onsite
    inspection, system design and testing of the reclaimed water system.
[4] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASSE 1061
    (1/2"-2" only), ASTM F1960, ASTM F1807, and ASTM F2098.


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* ^ ¢ § [1]
 
PEX 5106
 
hePEX
 
ASTM F876/F877
5/16" - 4"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Product may or may not bear the U.P.Code mark.

Tubing* ^ ¢ [2]
 
PEX 5106
 
hePEX
 
CSA B137.5
5/16" - 4"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1960,
    ASTM F1807, and ASTM F2098.

Tubing*
 
PEX
 
EcoFlex
 
ASTM F2788
110 mm  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.

Tubing* @ ¢ [3]
 
PEX 0006
 
hePEX
 
ASTM F876/F877
5/16"   3/8"   1/2"   5/8"  
3/4"   1"   1 1/4"   1 1/2"  
2"   2 1/2"   3"   3 1/2"  
4"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This barrier tubing product has been evaluated against the performance requirement of
  ASTM F876/F877.  This product has been evaluated for use in radiant floor heating. 
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[3] Product meets the most current dimensional requirements of ASTM F876.

Tubing* @ ¢ [4]
 
PEX
 
hePEX
 
CSA B137.5
5/16"   3/8"   1/2"   5/8"  
3/4"   1"   1 1/4"   1 1/2"  
2"   2 1/2"   3"   3 1/2"  
4"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This barrier tubing product has been evaluated against the performance requirement of
  ASTM F876/F877.  This product has been evaluated for use in radiant floor heating. 
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASSE 1061
    (3/8"-2" only), ASTM F1960, ASTM F1807, and ASTM F2098.

Tubing* @ ¢ [3]
 
PEX 0006
 
hePEX Plus
 
ASTM F876/F877
5/16"   3/8"   1/2"   5/8"  
3/4"   1"   1 1/4"   1 1/2"  
2"   2 1/2"   3"   3 1/2"  
4"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This barrier tubing product has been evaluated against the performance requirement of
  ASTM F876/F877.  This product has been evaluated for use in radiant floor heating. 
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[3] Product meets the most current dimensional requirements of ASTM F876.

Tubing* @ ¢ [4]
 
PEX
 
hePEX Plus
 
CSA B137.5
5/16"   3/8"   1/2"   5/8"  
3/4"   1"   1 1/4"   1 1/2"  
2"   2 1/2"   3"   3 1/2"  
4"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This barrier tubing product has been evaluated against the performance requirement of
  ASTM F876/F877.  This product has been evaluated for use in radiant floor heating. 
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASSE 1061
    (3/8"-2" only), ASTM F1960, ASTM F1807, and ASTM F2098.

Tubing* @ §
 
PEX 0306
 
helioPEX™ X2
 
ASTM F876/F877
5/16"   3/8"   1/2"   5/8"  
3/4"   1"   1 1/4"   1 1/2"  
2"   2 1/2"   3"   3 1/2"  
4"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This barrier tubing product has been evaluated against the performance requirement of
  ASTM F876/F877.  This product has been evaluated for use in radiant floor heating. 
  (NSF-rfh), applications only.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* @ ¢ [4]
 
PEX 0306
 
helioPEX™ X2
 
CSA B137.5
5/16"   3/8"   1/2"   5/8"  
3/4"   1"   1 1/4"   1 1/2"  
2"   2 1/2"   3"   3 1/2"  
4"  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This barrier tubing product has been evaluated against the performance requirement of
  ASTM F876/F877.  This product has been evaluated for use in radiant floor heating. 
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASSE 1061
    (3/8"-2" only), ASTM F1960, ASTM F1807, and ASTM F2098.


Facility : Hutchinson, MN

Fire Sprinkler Pipe and Fitting Systems

Product Type   Material Type   Trade Name   Product Standard

Pipe and Fitting System% ¢ **
 
PEX
 
AQUASAFE®*
 
ANSI/CAN/UL 1821

Tubing
3/4" Uponor AquaPEX White   1" Uponor AquaPEX White  

% PEX pipe and fittings are intended for use in multi-purpose piping systems of
  residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems
  in One- and Two- Family Dwellings and Manufactured Homes", the National Building Code of
  Canada, and the International Residential Code, Section 2904, and are designed to
  withstand a working pressure of not less than 130 psi at 120° F.  PEX pipe and fittings
  are intended to be installed in accordance with the requirements specified in the
  manufacturer’s installation instructions and ANSI/NFPA 13D. Protection is intended to be
  provided for PEX pipe and fittings in multi-purpose piping systems. The minimum
  protection should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a
  suspended membrane ceiling with lay-in panels or tiles having a weight of not less than
  0.35 lbs per sq ft when installed with metallic support grids, (3) 1/2 in plywood or (4)
  other material with a 15 minute fire rating.  PEX pipe and fittings are intended for use
  in areas where the maximum ambient temperature does not exceed 120° F.  These pipe and
  fittings are not intended to be installed in outdoor applications.  The PEX pipe and
  fittings are intended for use in wet-pipe systems only and have not been evaluated for
  use in drypipe systems.
* These products may also be represented by the trade name AquaPEX.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
** Pipe and fittings Certified as a system using installation and design manual titled
   "Uponor Residential Fire Sprinkler Systems, AquaSAFE™ System Installation Guide".


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* ^ ¢ § +++ [3] [5] [G]
 
PEX 5106
 
AquaPEX (Natural)
 
ASTM F876/F877
1/4" - 3" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Product may or may not bear the U.P. Code mark.
[5] May also use the trade names AquaPEX Natural, AquaPEX White, or AquaPEX Clear. 
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ +++ [2] [5] [G]
 
PEX 5106
 
AquaPEX (Natural)
 
CSA B137.5
1/4" - 3" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASSE 1061 (3/8"
    - 2" only), ASTM F1960, ASTM F1807, and ASTM F2098.
[5] May also use the trade names AquaPEX Natural, AquaPEX White, or AquaPEX Clear. 
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [3] [4] [G]
 
PEX 5306
 
AquaPEX (Red or Blue)
 
ASTM F876/F877
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Product may or may not bear the U.P. Code mark.
[4] Pipe may be marked PEX 5306, PEX 5206, or PEX 5106.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ +++ [1] [4] [G]
 
PEX 5306
 
AquaPEX (Red or Blue)
 
CSA B137.5
1/2" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASSE 1061 (1/2"
    - 2" only), ASTM F1960, ASTM F1807, and ASTM F2098.
[4] Pipe may be marked PEX 5306, PEX 5206, or PEX 5106.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe^ ¢ § ** +++ [3] [6] [G]
 
PEX 5106
 
ResiPEX™ (Natural)
 
ASTM F876/F877
1/2" - 2" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Accepted by NSF for use in residential construction, including manufactured housing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Product may or may not bear the U.P. Code mark.
[6] May also use the trade names ResiPEX Natural, ResiPEX White, or ResiPEX Clear
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe^ ¢ § ** +++ [1] [6] [G]
 
PEX 5106
 
ResiPEX™ (Natural)
 
CSA B137.5
1/2" - 2" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Accepted by NSF for use in residential construction, including manufactured housing.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASSE 1061 (1/2"
    - 2" only), ASTM F1960, ASTM F1807, and ASTM F2098.
[6] May also use the trade names ResiPEX Natural, ResiPEX White, or ResiPEX Clear
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



Viega LLC. 
585 Interlocken Boulevard
Broomfield, CO 80021 
United States 
800-774-5237 

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing# * ^ ~ ¡ ¢ § ** +++ [2] [G]
 
PEX 5306
 
Viega PureFlow PEX
 
AWWA C904
1/2" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Formerly Vanex Ultra.
¡ Black solid wall construction.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
   radiant heating system made in accordance with the current version of the ASTM F877
   standard intended for a maximum 100 psi water service and a maximum working temperature
   of 180°F.  System components consist of tubing and/or fittings.  To be installed in
   accordance with manufacturer’s instructions and the latest edition of the Uniform
   Plumbing Code.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] This PEX tubing may also be marked ViegaPEX ULTRA.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * @ ^ ~ § ** +++ [3] [G]
 
PEX 5306
 
Viega PureFlow PEX
 
AWWA C904
1/2" - 1 1/2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Red, white, or blue solid wall construction. 
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Formerly Vanex Ultra.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
   radiant heating system made in accordance with the current version of the ASTM F877
   standard intended for a maximum 100 psi water service and a maximum working temperature
   of 180°F.  System components consist of tubing and/or fittings.  To be installed in
   accordance with manufacturer’s instructions and the latest edition of the Uniform
   Plumbing Code.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] This PEX tubing may also be marked ViegaPEX.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Riser Assemblies (PW)* @ ^ § +++ [4]
 
PEX
 
Viega PureFlow PEX Riser
 
ASME A112.18.6/CSA B125.6
1/4" CTS O.D., 12" - 72" length

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Red, white, or blue solid wall construction. 
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[4] These Viega PureFlow PEX Risers may also be marked as ViegaPEX Risers.

Tubing# $ * ^ ¢ § ++ [5] [G]
 
PEX 5306
 
Viega Barrier
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
$ This product is barrier tubing.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[5] This PEX tubing may also be marked ViegaPEX Barrier.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ * ^ ¢ § ++ [5] [7] [G]
 
PEX 5306
 
Viega Barrier
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
$ This product is barrier tubing.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[5] This PEX tubing may also be marked ViegaPEX Barrier.
[7] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASTM F3347, ASTM F3348, and ASTM F877.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing* @ ^ § +++ [4] [G]
 
PEX 5106
 
Viega PureFlow PEX Riser
 
ASTM F876/F877
1/4" - 3/8" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Red, white, or blue solid wall construction. 
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[4] These Viega PureFlow PEX Risers may also be marked as ViegaPEX Risers.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * ^ ¡ ¢ § ** +++ [2] [G]
 
PEX 5306
 
Viega PureFlow PEX
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¡ Black solid wall construction.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
   radiant heating system made in accordance with the current version of the ASTM F877
   standard intended for a maximum 100 psi water service and a maximum working temperature
   of 180°F.  System components consist of tubing and/or fittings.  To be installed in
   accordance with manufacturer’s instructions and the latest edition of the Uniform
   Plumbing Code.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] This PEX tubing may also be marked ViegaPEX ULTRA.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * @ ^ ¢ § ** +++ [3] [G]
 
PEX 5306
 
Viega PureFlow PEX
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Red, white, or blue solid wall construction. 
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
   radiant heating system made in accordance with the current version of the ASTM F877
   standard intended for a maximum 100 psi water service and a maximum working temperature
   of 180°F.  System components consist of tubing and/or fittings.  To be installed in
   accordance with manufacturer’s instructions and the latest edition of the Uniform
   Plumbing Code.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] This PEX tubing may also be marked ViegaPEX.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * ^ ¡ ¢ § ** +++ [2] [7] [G]
 
PEX 5306
 
Viega PureFlow PEX
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¡ Black solid wall construction.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
   radiant heating system made in accordance with the current version of the ASTM F877
   standard intended for a maximum 100 psi water service and a maximum working temperature
   of 180°F.  System components consist of tubing and/or fittings.  To be installed in
   accordance with manufacturer’s instructions and the latest edition of the Uniform
   Plumbing Code.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] This PEX tubing may also be marked ViegaPEX ULTRA.
[7] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASTM F3347, ASTM F3348, and ASTM F877.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * ^ ¢ § ** +++ [3] [7] [G]
 
PEX 5306
 
Viega PureFlow PEX
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
   radiant heating system made in accordance with the current version of the ASTM F877
   standard intended for a maximum 100 psi water service and a maximum working temperature
   of 180°F.  System components consist of tubing and/or fittings.  To be installed in
   accordance with manufacturer’s instructions and the latest edition of the Uniform
   Plumbing Code.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] This PEX tubing may also be marked ViegaPEX.
[7] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASTM F3347, ASTM F3348, and ASTM F877.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

± Certified for tubing with a black inner layer and red or natural outer layer.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ * ^ ¢ [5]
 
PEX 5306
 
Viega Barrier
 
ASTM F3253
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
$ This product is barrier tubing.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[5] This PEX tubing may also be marked ViegaPEX Barrier.

Tubing# * ^ ¡ ¢ § ** [2]
 
PEX 5306
 
Viega PureFlow PEX
 
AWWA C904
1/2" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¡ Black solid wall construction.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
   radiant heating system made in accordance with the current version of the ASTM F877
   standard intended for a maximum 100 psi water service and a maximum working temperature
   of 180°F.  System components consist of tubing and/or fittings.  To be installed in
   accordance with manufacturer’s instructions and the latest edition of the Uniform
   Plumbing Code™.
[2] This PEX tubing may also be marked ViegaPEX ULTRA.

Tubing# * @ ^ ¢ § ** [3]
 
PEX 5306
 
Viega PureFlow PEX
 
AWWA C904
1/2" - 1 1/2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Red, white, or blue solid wall construction. 
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
   radiant heating system made in accordance with the current version of the ASTM F877
   standard intended for a maximum 100 psi water service and a maximum working temperature
   of 180°F.  System components consist of tubing and/or fittings.  To be installed in
   accordance with manufacturer’s instructions and the latest edition of the Uniform
   Plumbing Code™.
[3] This PEX tubing may also be marked ViegaPEX.

Riser Assemblies (PW)* @ ^ § [4]
 
PEX
 
Viega PureFlow PEX Riser
 
ASME A112.18.6/CSA B125.6
1/4" CTS O.D., 12" - 72" length

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Red, white, or blue solid wall construction. 
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] These Viega PureFlow PEX Risers may also be marked as ViegaPEX Risers.

Tubing# $ * ^ ¢ § [5]
 
PEX 5306
 
Viega Barrier
 
ASTM F876/F877
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
$ This product is barrier tubing.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[5] This PEX tubing may also be marked ViegaPEX Barrier.

Tubing# $ * ^ ¢ § [5] [7]
 
PEX 5306
 
Viega Barrier
 
CSA B137.5
1/4" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
$ This product is barrier tubing.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[5] This PEX tubing may also be marked ViegaPEX Barrier.
[7] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASTM F3347, ASTM F3348, and ASTM F877.

Tubing* @ ^ § [4]
 
PEX 5106
 
Viega PureFlow PEX Riser
 
ASTM F876/F877
1/4" - 3/8" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Red, white, or blue solid wall construction. 
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] These Viega PureFlow PEX Risers may also be marked as ViegaPEX Risers.

Tubing# * ^ ¡ ¢ § ** [2]
 
PEX 5306
 
Viega PureFlow PEX
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¡ Black solid wall construction.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
   radiant heating system made in accordance with the current version of the ASTM F877
   standard intended for a maximum 100 psi water service and a maximum working temperature
   of 180°F.  System components consist of tubing and/or fittings.  To be installed in
   accordance with manufacturer’s instructions and the latest edition of the Uniform
   Plumbing Code™.
[2] This PEX tubing may also be marked ViegaPEX ULTRA.

Tubing# * @ ^ ¢ § ** [3]
 
PEX 5306
 
Viega PureFlow PEX
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Red, white, or blue solid wall construction. 
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
   radiant heating system made in accordance with the current version of the ASTM F877
   standard intended for a maximum 100 psi water service and a maximum working temperature
   of 180°F.  System components consist of tubing and/or fittings.  To be installed in
   accordance with manufacturer’s instructions and the latest edition of the Uniform
   Plumbing Code™.
[3] This PEX tubing may also be marked ViegaPEX.

Tubing# * ^ ¡ ¢ § ** [2] [7]
 
PEX 5306
 
Viega PureFlow PEX
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¡ Black solid wall construction.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
   radiant heating system made in accordance with the current version of the ASTM F877
   standard intended for a maximum 100 psi water service and a maximum working temperature
   of 180°F.  System components consist of tubing and/or fittings.  To be installed in
   accordance with manufacturer’s instructions and the latest edition of the Uniform
   Plumbing Code™.
[2] This PEX tubing may also be marked ViegaPEX ULTRA.
[7] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASTM F3347, ASTM F3348, and ASTM F877.

Tubing# * @ ^ ¢ § ** [3] [7]
 
PEX 5306
 
Viega PureFlow PEX
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by Viega LLC. 
  Installation/assembly instructions titled “Installation Guidelines for Viega Insert
  Fittings Systems”, most current edition.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Red, white, or blue solid wall construction. 
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
   radiant heating system made in accordance with the current version of the ASTM F877
   standard intended for a maximum 100 psi water service and a maximum working temperature
   of 180°F.  System components consist of tubing and/or fittings.  To be installed in
   accordance with manufacturer’s instructions and the latest edition of the Uniform
   Plumbing Code™.
[3] This PEX tubing may also be marked ViegaPEX.
[7] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F2159, ASTM F3347, ASTM F3348, and ASTM F877.

~ Formerly Vanex Ultra.
± Certified for tubing with a black innner layer and red or natural outer layer.


 
Waterline Products Co. Limited 
100 Westcreek Blvd, Unit 2
Brampton, ON L6T 5V7 
Canada 
+1 905 453 2400

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing$ &
 
PEX
 
Waterline PEX
 
CAN/ULC S102.2

3/8", 1/2" - 2"
Flame Spread Rating <= 25   Smoke Developed Classification <= 50  

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index
  based on when the tubing is field insulated with JM Microlok HP Hi Performance
  Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing
  shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing# $ *
 
PEX
 
Waterline PEX
 
ASTM E84

3/8", 1/2" - 2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fittings[1]
 
PEX
 
Waterline
 
ASTM F1960

PEX Ring with Stop
3/8" - 2"  

[1] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted
    product.

Fittings[1]
 
PEX
 
Waterline
 
CSA B137.5

PEX Ring with Stop
3/8" - 2"  

[1] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted
    product.

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
Waterline PEX
 
ASTM F876/F877
>=1/8" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ ¢ § +++ [G]
 
PEX
 
Waterline PEX
 
CSA B137.5
>=1/8" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Fittings[1]
 
PEX
 
Waterline
 
ASTM F1960

PEX Ring with Stop
3/8" - 2"  

[1] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted
    product.

Fittings[1]
 
PEX
 
Waterline
 
CSA B137.5

PEX Ring with Stop
3/8" - 2"  

[1] This is a PEX sleeve certified to ASTM F1960 & CSA B137.5. This is a non wetted
    product.

Tubing$ * §
 
PEX 5006
 
Waterline PEX
 
ASTM F876/F877
>=1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * ¢ §
 
PEX
 
Waterline PEX
 
CSA B137.5
>=1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
Waterline Products Co. Limited 
100 Westcreek Boulevard #2
Brampton, ON L6T 5V7 
Canada 
800-361-3773 
905-625-9481
Visit this company's website

Facility : # 1 Canada

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing! * ¢ § ++ [G]
 
PEX 5106, PEX 5306
 
ColdX Tubing
 
ASTM F876/F877
3/8" - 2"

! Certified for blue, natural, red colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ¢ § ++ [1] [G]
 
PEX 5106, PEX 5306
 
ColdX Tubing
 
CSA B137.5
3/8" - 2"

! Certified for blue, natural, red colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[1] Tubing certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM
    F2159, ASTM F1807, ASTM F1960, and ASTM F2098.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Waterline Products Co. Ltd. 
238 Britannia Road East
Mississauga, ON L4Z 1S6 
Canada 
905-625-9440

Facility : Middlefield, OH

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing# @ ^ ¢ § +++ [G]
 
PEX 5106
 
Waterline
 
ASTM F876/F877
1/8" - 1" SDR 9

# Authorized for gray and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# & @ ¢ +++ [G]
 
PEX 5106
 
Waterline
 
CSA B137.5
1/8" - 1" SDR 9

# Authorized for gray and white.
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations: ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061, and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing# @ ^ ¢ §
 
PEX 5006
 
Waterline
 
ASTM F876/F877
1/8" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# & @ ¢
 
PEX 5006
 
Waterline
 
CSA B137.5
1/8" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations: ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061, and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.



 
Watts Regulator Co. 
815 Chestnut Street
North Andover, MA 01845 
United States 
417-447-8042

Facility : # 3 USA

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe$ * §
 
PEX 3006
 
WaterPEXa
 
ASTM F876/F877
3/8" - 1" SDR 9

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ * ¢ §
 
PEX
 
WaterPEXa
 
CSA B137.5
3/8" - 1" SDR 9

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
Watts Regulator Company 
815 Chestnut Street
North Andover, MA 01845 
United States 
978-689-6158

Facility : Marshall, MI

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fitting Components§
 
PEX
 
Watts
 
ASTM F1960
1/2" Ring (PFS3-10)   3/4" Ring (PFS4-10)   3/8" Ring (PFS2-10)   5/8" Ring (PFS6-10)  

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Fitting Components§
 
PEX
 
Watts
 
CSA B137.5
1/2" Ring (PFS3-10)   3/4" Ring (PFS4-10)   3/8" Ring (PFS2-10)   5/8" Ring (PFS6-10)  

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
Watts Regulator Company 
815 Chestnut Street
North Andover, MA 01845 
United States 
978-689-1811

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe! @ ^ ¢ § +++ [G]
 
PEX 5306
 
PlumbFLOW
 
ASTM F876/F877
1/8" - 2" SDR 9

! Product may or may not bear the NSF U.P. code marking.
@ Product available in red, white, blue or natural.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe@ ^ ¢ +++ [G]
 
PEX 5306
 
PlumbFLOW
 
CSA B137.5
1/8" - 2" SDR 9

@ Product available in red, white, blue or natural.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe! @ ^ ¢ § +++ [G]
 
PEX 5306
 
RF PEX™ by WATTS
 
ASTM F876/F877
1/8" – 2" SDR 9

! Product may or may not bear the NSF U.P. code marking.
@ Product available in red, white, blue or natural.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe! @ ^ ¢ § +++ [G]
 
PEX 5306
 
RF PEX™ by Watts
 
AWWA C904
1/2" – 1 1/2" SDR 9

! Product may or may not bear the NSF U.P. code marking.
@ Product available in red, white, blue or natural.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe@ ^ ¢ § +++ [G]
 
PEX 5306
 
RF PEX™ by WATTS
 
CSA B137.5
1/8" – 2" SDR 9

@ Product available in red, white, blue or natural.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe! @ ^ ¢ § +++ [G]
 
PEX 5306
 
WaterPEX
 
ASTM F876/F877
1/8" - 2" SDR 9

! Product may or may not bear the NSF U.P. code marking.
@ Product available in red, white, blue or natural.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe! @ ^ ¢ § +++ [G]
 
PEX 5306
 
WaterPEX
 
AWWA C904
1/2" – 1 1/2" SDR 9

! Product may or may not bear the NSF U.P. code marking.
@ Product available in red, white, blue or natural.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe@ ^ ¢ +++ [G]
 
PEX 5306
 
WaterPEX
 
CSA B137.5
1/8" - 2" SDR 9

@ Product available in red, white, blue or natural.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

$ Product is barrier tubing. Red, orange, or gray.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe! $ ^ ¢ §
 
PEX 5006
 
RadiantFLOW
 
ASTM F876/F877
1/8" - 2"

! Product may or may not bear the NSF U.P. code marking.
$ Product is barrier tubing.  Red, orange, or gray.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
  
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ ^ ¢
 
PEX 5006
 
RadiantFLOW
 
CSA B137.5
1/8" - 2"

$ Product is barrier tubing.  Red, orange, or gray.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
  
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.

Tubing! % ^ §
 
PEX 5006
 
RadiantPEX+ (w/O2 Barrier)
 
ASTM F876/F877
1/8" - 1"

! Product may or may not bear the NSF U.P. code marking.
% Certified product is orange or natural in color.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
  
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing% ^ ¢
 
PEX 5006
 
RadiantPEX+ (w/O2 Barrier)
 
CSA B137.5
1/8" - 1"

% Certified product is orange or natural in color.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
  
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.



 
Watts Regulator Company 
815 Chestnut Street
North Andover, MA 01845-6098 
United States 
978-688-1811

Facility : Guangdong, China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
WaterPEX
 
ASTM F876/F877
>= 1/8" Sch 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ ¢ § +++ [G]
 
PEX
 
WaterPEX
 
CSA B137.5
>= 1/8" Sch 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ¢ §
 
PEX
 
WaterPEX
 
CSA B137.5
>= 1/8" Sch 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * §
 
PEX 5006
 
WaterPEX
 
ASTM F876/F877
>= 1/8" Sch 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
Wavin USA Inc. 
950 Winter Street
South Entrance 1st Floor 
Waltham, MA 02451 
United States 
800-763-3632 
514-735-3632
Visit this company's website

Facility : Spain

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
Wavin PEX-A
 
ASTM F876/F877
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 2" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* @ ¢ § +++ [G]
 
PEX 5106
 
Wavin PEX-A
 
CSA B137.5
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2"sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 2" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
@ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
  accordance with ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* @ ¢ §
 
PEX 5106
 
Wavin PEX-A
 
ASTM F876/F877
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white
  and orange) are certified for the following sizes: 3/8", 1/2", 5/8", 3/4", 1", 1-1/4",
  1-1/2" & 2".				
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s)
  for which the tubing is recommended by the manufacturer, and shall be marked, as
  applicable with the
  following fitting system designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM
  F2098.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* @ ¢ §
 
PEX 5106
 
Wavin PEX-A
 
CSA B137.5
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white
  and orange) are certified for the following sizes: 3/8", 1/2", 5/8", 3/4", 1", 1-1/4",
  1-1/2" & 2".				
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s)
  for which the tubing is recommended by the manufacturer, and shall be marked, as
  applicable with the
  following fitting system designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM
  F2098.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
Weifang Palconn Plastics Technology Co., Ltd. 
Yinma Industrial Park, Changyi Town
WeiFang City, Shandong Province 261317 
China 
86 139 0636 9120
Visit this company's website

Facility : Shandong Province, China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe$ ¢ § +++ [1] [G]
 
PEX 5306
 
PALCONN PEX Tubing
 
ASTM F876/F877
3/8", 1/2", 5/8", 3/4", 1", 1-1/4", 1-1/2", 2"

$ Certified for blue, natural, white and red without oxygen barrier.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for PEX solid wall pipe.
    Natural -  PEX5006 
    Red, White, Blue - PEX 5306
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe$ ¢ § +++ [1] [G]
 
PEX 5306
 
PALCONN PEX Tubing
 
CSA B137.5
3/8", 1/2", 5/8", 3/4", 1", 1-1/4", 1-1/2", 2"

$ Certified for blue, natural, white and red without oxygen barrier.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for PEX solid wall pipe.
    Natural -  PEX5006 
    Red, White, Blue - PEX 5306
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe# ¢ § +++
 
PEX 5006/5106
 
PALCONN PEX Barrier Tubing
 
ASTM F876/F877
3/8", 1/2", 5/8", 3/4", 1"

# Certified for blue, natural, orange, and red.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe# ¢ § +++
 
PEX 5006/5106
 
PALCONN PEX Barrier Tubing
 
CSA B137.5
3/8", 1/2", 5/8", 3/4", 1"

# Certified for blue, natural, orange, and red.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).



 
Weihai Lianqiao New Material Science & Technology Co., Ltd. 
No. 8 Shihai Street, Chucun
Town, Huan Cui District 
Weihai, Shandong Province 
China 
86 631 569 6087
Visit this company's website

Facility : Shandong, China

Potable Water - Materials

Material Type End Use Trade Name Product Standard
PEX 5306% § 1 LIC XL21001LA/XL21001LB ASTM F876/F877
PEX 5306% § 1 LIC XL21001LA/XL21001LB CSA B137.5

% Certified for natural, red, white and blue material.
  Natural - PEX 5006
  Red, White, Blue - PEX 5306
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.


Radiant Floor Heating - Materials

Material Type End Use Trade Name Product Standard
PEX 5306% § 1 LIC XL21001LA/XL21001LB ASTM F876/F877
PEX 5306% § 1 LIC XL21001LA/XL21001LB CSA B137.5

% Certified for natural, red, white and blue material.
  Natural - PEX 5006
  Red, White, Blue - PEX 5306
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

NSF Certified materials and generic ingredients are exempt from bearing an NSF Certification Mark. Certified materials and generic ingredients are identified by the manufacturer name, facility location, and trade designation as shown in the Official Listing.



 
XPAND 
9451 Boulevard Langelier
Montreal, QC H1P 0A1 
Canada 
514-378-0049
Visit this company's website

Facility : Barcelona, Spain

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* ¢ §  @ +++ [G]
 
PEX 5106
 
XPAND
 
ASTM F876/F877
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2" sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 2" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
 @ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
   accordance with ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ¢ §  @ +++ [G]
 
PEX 5106
 
XPAND
 
CSA B137.5
3/8" - 2"

* Natural (Solid Wall) PEX Pipe Certified 3/8" - 2" sizes.  Red, blue, white or orange PEX
  pipe (2 layer pipe - natural with colored adhesive pipe) certified for 3/8" - 2" sizes.
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1960,
  ASTM F1807, ASTM F2159, and ASTM F2098.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
 @ PEX 5106: Meets the chlorine resistance requirements of ASTM F876 when tested in
   accordance with ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* @ ¢ §
 
PEX 5106
 
XPAND
 
ASTM F876/F877
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white
  and orange) are certified for the following sizes: 3/8", 1/2", 5/8", 3/4", 1", 1-1/4",
  1-1/2" & 2".
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s)
  for which the tubing is recommended by the manufacturer, and shall be marked, as
  applicable with the
  following fitting system designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM
  F2098.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* @ ¢ §
 
PEX 5106
 
XPAND
 
CSA B137.5
3/8" - 2"

* Monowall pipe (natural); Skinned pipe (red, blue, white and orange); and Barrier pipe
  (red, blue, white
  and orange) are certified for the following sizes: 3/8", 1/2", 5/8", 3/4", 1", 1-1/4",
  1-1/2" & 2".
  Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s)
  for which the tubing is recommended by the manufacturer, and shall be marked, as
  applicable with the
  following fitting system designation(s): ASTM F1960, ASTM F1807, ASTM F2159, and ASTM
  F2098.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877 and CSA B137.5.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
Yueqing Dongbo Electromechanical Co., Ltd. 
Xizhu Industrial Zone Shifan Yueqing
Zhejiang 325608 
China 
86 577 6231 2247

Facility : Zhejiang, China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fittings¢ § [1]
 
PEX
 
dwb
 
ASTM F1960
3/8" PEX123
1/2" PEX161
5/8" PEX192
3/4" PEX224
1" PEX288
1 1/4" PEX353
1 1/2" PEX417
2" PEX547
2 1/2" PEX675
3" PEX802

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Product is a non-wetted fitting component.

Fittings¢ § [1]
 
PEX
 
dwb
 
CSA B137.5
3/8" PEX123
1/2" PEX161
5/8" PEX192
3/4" PEX224
1" PEX288
1 1/4" PEX353
1 1/2" PEX417
2" PEX547
2 1/2" PEX675
3" PEX802

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Product is a non-wetted fitting component.



 
Zhejiang Iwiss Electric Co., Ltd. 
Jiedai Industrial District
Chengnan Subdistrict,Yueqing 
Wenzhou 325699 
China 
86 577 6178 6606

Facility : Zhejiang, China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fittings¢ § [1]
 
PEX
 
dwb
 
ASTM F1960
3/8" PEX123
1/2" PEX161
5/8" PEX192
3/4" PEX224
1" PEX288
1 1/4" PEX353
1 1/2" PEX417
2" PEX547
2 1/2" PEX675
3" PEX802

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Product is a non-wetted fitting component.

Fittings¢ § [1]
 
PEX
 
dwb
 
CSA B137.5
3/8" PEX123
1/2" PEX161
5/8" PEX192
3/4" PEX224
1" PEX288
1 1/4" PEX353
1 1/2" PEX417
2" PEX547
2 1/2" PEX675
3" PEX802

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Product is a non-wetted fitting component.



 
Zurn PEX, Inc. 
116 Maple Street
Commerce, TX 75428 
United States 
903-886-2580
Visit this company's website

Facility : # 8 China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fitting Components# ¢ § +++
 
PEX
 
Zurn
 
ASTM F1960
ZPEX QER2X 3/8"
ZPEX QER3X 1/2"
ZPEX QER4X 3/4"
ZPEX QER5X 1"
ZPEX QER6X 1 1/4"
ZPEX QER7X 1 1/2"
ZPEX QER8X 2"

# Zurn rings can only be used with Zurn PEX pipe, Zurn brass F1960 Fittings and Zurn
  plastic F1960 Fittings.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Fitting Components# ¢ § +++
 
PEX
 
Zurn
 
CSA B137.5
ZPEX QER2X 3/8"
ZPEX QER3X 1/2"
ZPEX QER4X 3/4"
ZPEX QER5X 1"
ZPEX QER6X 1 1/4"
ZPEX QER7X 1 1/2"
ZPEX QER8X 2"

# Zurn rings can only be used with Zurn PEX pipe, Zurn brass F1960 Fittings and Zurn
  plastic F1960 Fittings.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).


Facility : Harborcreek, PA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
ACCUTEK PEX - Blue, Red, White
 
ASTM F876/F877
1/8" - 2" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
ACCUTEK PEX - Blue, Red, White
 
AWWA C904
1/2" - 2" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# ^ ¢ § +++ [G]
 
PEX
 
ACCUTEK PEX - Blue, Red, White
 
CSA B137.5
1/8" - 2" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2159, ASTM F1960, and ASTM F2098.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
CAST Fast-Fit - Blue, Red, White
 
ASTM F876/F877
1/8" - 2" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
CAST Fast-Fit - Blue, Red, White
 
AWWA C904
1/2" - 2" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# ^ ¢ § +++ [G]
 
PEX
 
CAST Fast-Fit - Blue, Red, White
 
CSA B137.5
1/8" - 2" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2159, ASTM F1960, and ASTM F2098.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
QEST®PEX - Blue, Red, White
 
ASTM F876/F877
1/8" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
QEST®PEX - Blue, Red, White
 
AWWA C904
1/2" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# ^ ¢ § +++ [G]
 
PEX
 
QEST®PEX - Blue, Red, White
 
CSA B137.5
1/8" - 2"

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2159, ASTM F1960, and ASTM F2098.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
WarmPex - Red
 
ASTM F876/F877
1/8" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
WarmPex - Red
 
AWWA C904
1/2" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# ^ ¢ § +++ [G]
 
PEX
 
WarmPex - Red
 
CSA B137.5
1/8" - 2"

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2159, ASTM F1960, and ASTM F2098.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
ZURNPEX - Blue, Red, White
 
ASTM F876/F877
1/8" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
ZURNPEX - Blue, Red, White
 
AWWA C904
1/2" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# ^ ¢ § +++ [G]
 
PEX
 
ZURNPEX - Blue, Red, White
 
CSA B137.5
1/8" - 2"

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2159, ASTM F1960, and ASTM F2098.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing#
 
PEX 0006
 
ACCUTEK PEX - Blue, Natural, Red, White
 
SE 8221
3/8" - 1"

# Pipe Certified as a system using QEST®PEX fittings manufactured by ZurnPex Inc. 
  Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.

Tubing#
 
PEX 0006
 
QEST®PEX Hydronic Barrier-Blue, Red, Natural
 
SE 8221
3/8" - 1"

# Pipe Certified as a system using QEST®PEX fittings manufactured by ZurnPex Inc. 
  Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.

Tubing#
 
PEX 0006
 
Slant/Fin Terra Therma
 
SE 8221
3/8" - 1"

# Pipe Certified as a system using QEST®PEX fittings manufactured by ZurnPex Inc. 
  Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.

Tubing#
 
PEX 0006
 
WarmPex - Red
 
SE 8221
3/8" - 1"

# Pipe Certified as a system using QEST®PEX fittings manufactured by ZurnPex Inc. 
  Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.

Tubing#
 
PEX 0006
 
ZURNPEX Hydronic Barrier - Blue, Red, Natural
 
SE 8221
3/8" - 1"

# Pipe Certified as a system using QEST®PEX fittings manufactured by ZurnPex Inc. 
  Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.

Tubing#
 
PEX 0006
 
Zurn PEX Performa
 
SE 8221
3/8" - 1"

# Pipe Certified as a system using QEST®PEX fittings manufactured by ZurnPex Inc. 
  Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.


Facility : Commerce, TX

Fire Sprinkler Pipe and Fitting Systems

Product Type   Material Type   Trade Name   Product Standard

Pipe and Fitting System% ** [G]
 
PEX
 
Zurn PEX Fire Protection System
 
ANSI/CAN/UL 1821

Tubing
1" White ZurnPEX  

% PEX pipe and fittings are intended for use in multi-purpose piping systems of
  residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems
  in One- and Two- Family Dwellings and Manufactured Homes" and the International
  Residential Code, Section 2904, and are designed to withstand a working pressure of not
  less than 130 psi at 120° F.  PEX pipe and fittings are intended to be installed in
  accordance with the requirements specified in the manufacturer’s installation
  instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and
  fittings in multi-purpose piping systems.  The minimum protection should consist of
  either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended membrane ceiling with
  lay-in panels or tiles having a weight of not less than 0.35 lbs per sq ft when
  installed with metallic support grids, (3) 1/2 in plywood or (4) other material with a
  15 minute fire rating. PEX pipe and fittings are intended for use in areas where the
  maximum ambient temperature does not exceed 120° F. These pipe and fittings are not
  intended to be installed in outdoor applications. The PEX pipe and fittings are intended
  for use in wet-pipe systems only and have not been evaluated for use in dry-pipe systems.
** Pipe and fittings Certified as a system using Installation/assembly instructions titled
   "Zurn PEX Residential Fire Protection Addendum to Plumbing Installation Guide", dated
   October 2010.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
ACCUTEK PEX - Blue, Red, White
 
ASTM F876/F877
1/8” – 2” SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
ACCUTEK PEX - Blue, Red, White
 
AWWA C904
1/2" – 1 1/4" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX
 
ACCUTEK PEX - Blue, Red, White
 
CSA B137.5
1/8” – 2" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
CAST Fast-Fit - Blue, Red, White
 
ASTM F876/F877
1/8” – 2” SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
CAST Fast-Fit - Blue, Red, White
 
AWWA C904
1/2" – 1 1/4" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX
 
CAST Fast-Fit - Blue, Red, White
 
CSA B137.5
1/8” – 2” SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
QEST®PEX - Blue, Red, White
 
ASTM F876/F877
1/8” – 2” SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
QEST®PEX - Blue, Red, White
 
AWWA C904
1/2" – 1 1/4" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX
 
QEST®PEX - Blue, Red, White
 
CSA B137.5
1/8” – 2” SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
WarmPEX - Red
 
ASTM F876/F877
1/8” – 2" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
WarmPEX – Red
 
AWWA C904
1/2" – 1 1/4" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX
 
WarmPEX - Red
 
CSA B137.5
1/8” – 2” SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
ZURNPEX - Blue, Red, White
 
ASTM F876/F877
1/8” – 2”

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
ZURNPEX - Blue, Red, White
 
AWWA C904
1/2" – 1 1/4" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# ^ ¢ § +++ [G]
 
PEX
 
ZURNPEX - Blue, Red, White
 
CSA B137.5
1/8” – 2” SDR 9

# Pipe tested as a system using QEST®PEX fittings manufactured by United States Brass
  Corporation. 
   Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Zurn PEX, Inc. 
116 Maple Street
Commerce, TX 75428 
United States 
903-886-2580
Visit this company's website

Facility : # 1 Canada

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ ? @ ^ ~ § +++ [G]
 
PEX 5306
 
Zurn PEX
 
ASTM F876/F877
1/4" - 2" SDR 9

$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing? @ ^ ~ § +++ [G]
 
PEX 5306
 
Zurn PEX
 
AWWA C904
1/2" - 2" SDR 9

? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ ? @ ^ ~ ¢ § +++ [1] [G]
 
PEX 5306
 
Zurn PEX
 
CSA B137.5
1/4" - 2" SDR 9

$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white, light blue and blue pipe.
@ Certified for red, blue, white and natural colors.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Number of matching Manufacturers is 87
Number of matching Products is 3170
Processing time was 2 seconds