NSF Product and Service Listings

These NSF Official Listings are current as of Sunday, November 18, 2018 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Plumbing/Listings.asp?MaterialType=PEX&


NSF/ANSI 14
Plastics Piping System Components and Related Materials


Click here for a list of End Use Code Designations.

Click on Product Standards or footnote in blue to view the referenced document



 
Alro Products International LLC 
2348 Linden Blvd
Brooklyn, NY 11208 
United States 
718-566-1000

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ *
 
PEX
 
AlroPex
 
ASTM E84

3/8", 1/2" - 2"
Flame Spread Index <=25   Smoke Developed Index <=50  

# The Flame Spread Index and Smoke Developed Index for 1/2" - 2" tubing are based on when
  tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions.  The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing$ &
 
PEX
 
AlroPex
 
CAN/ULC S102.2

3/8", 1/2" - 2"
Flame Spread Rating <=25   Smoke Developed Classification <=50  

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ ¢ § [G]
 
PEX
 
AlroPex
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ¢ §
 
PEX
 
AlroPex
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
ATI Systems, Inc. 
4339 Main Street
Conestoga, PA 17516 
United States 
717-871-9851

Facility : # 1 Canada

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing% * ^ ++
 
PEX 5006
 
ATI Systems Radiant PEX
 
ASTM F876/F877
1/4" thru 2" SDR 9

% Certified ATI Systems Radiant PEX has a red outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).



 
Auray Managing, S.L. 
P.I. Riera de Caldes
Carrer dels Mercaders, 42, Palau-solità 
i Plegamans, Barcelona 08184 
Spain 
34 93 748 10 36
Visit this company's website

Facility : Barcelona, Spain

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe+ @ ¢ § [G]
 
PEX 5006
 
PIPEX
 
ASTM F876/F877
3/8" - 1"

+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
@ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ @ ¢ § [G]
 
PEX 5006
 
PIPEX
 
CSA B137.5
3/8" - 1"

+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
@ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
BLD Industries 
987 Josiane Court
Suite 1064 
Altamonte Springs, FL 32701 
United States 
321-207-0050
Visit this company's website

Facility : # 2 China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe¢ § +++ [G]
 
PEX 5006
 
PRIME PEX Tubing
 
ASTM F876/F877
3/8", 1/2", 5/8", 3/4", 1"

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe¢ § +++ [G]
 
PEX 5006
 
PRIME PEX Tubing
 
CSA B137.5
3/8", 1/2", 5/8", 3/4", 1"

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe¢ § +++
 
PEX 5006
 
PRIME PEX Barrier Tubing
 
ASTM F876/F877
3/8", 1/2", 5/8", 3/4", 1"

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe¢ § +++
 
PEX 5006
 
PRIME PEX Barrier Tubing
 
CSA B137.5
3/8", 1/2", 5/8", 3/4", 1"

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).



 
Borealis AB 
SE 444 86 Stenungsund
Sweden 
46 303 860 00
Visit this company's website

Facility : Stenungsund, Sweden

Potable Water - Materials

Material Type End Use Trade Name Product Standard
PEX 5006* ^ +++ 1 HE1878E-C2 N/A

* Use of this material in NSF Certified tubing requires NSF's prior authorization.  Tubing
  produced from this material was tested to the performance requirements of ASTM F876.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).


Radiant Floor Heating - Materials

Material Type End Use Trade Name Product Standard
PEX 5006* 1 HE1878E-C2 N/A

* Use of this material in NSF Certified tubing requires NSF's prior authorization.  Tubing
  produced from this material was tested to the performance requirements of ASTM F876.

NSF Certified materials and generic ingredients are exempt from bearing an NSF Certification Mark. Certified materials and generic ingredients are identified by the manufacturer name, facility location, and trade designation as shown in the Official Listing.



 
Bow Plumbing Group, Inc. 
15 Vittie Street
Granby, QC J2G 6N8 
Canada 
450-372-5481
Visit this company's website

Facility : Granby, Quebec, Canada

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing! $ * ^ § ++ [G]
 
PEX 5006
 
Bowpex
 
ASTM F876/F877
1/8" - 2"

! Product may or may not bear the NSF U.P. code marking.
$ Certified tubing is natural.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ & ¢ ++ [G]
 
PEX
 
Bowpex
 
CSA B137.5
1/8" - 2"

$ Certified tubing is natural.
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked with the following fitting system designations:  ASTM F1807, ASTM F2159.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! % * ^ ¢ § ++ [G]
 
PEX 5006
 
Oxypex
 
ASTM F876/F877
1/4" - 2" SDR 9

! Product may or may not bear the NSF U.P. code marking.
% Certified Oxypex tubing has a red outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing% & ¢ ++ [G]
 
PEX
 
Oxypex
 
CSA B137.5
1/4" - 2" SDR 9

% Certified Oxypex tubing has a red outer layer.
& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked with the following fitting system designations:  ASTM F1807, ASTM F2159.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * @ ^ § ++ [G]
 
PEX 5306/5006
 
Bow Superpex
 
ASTM F876/F877
1/4" - 1 1/4"

! Product may or may not bear the NSF U.P. code marking.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Certified Bow Superpex tubing has a blue, red, or white outer layer.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * @ ^ § ++ [G]
 
PEX 5306/5006
 
Bow Superpex
 
AWWA C904
1/2" - 1 1/4"

! Product may or may not bear the NSF U.P. code marking.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Certified Bow Superpex tubing has a blue, red, or white outer layer.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& @ ¢ ++ [G]
 
PEX
 
Bow Superpex
 
CSA B137.5
1/4" - 1 1/4"

& Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked with the following fitting system designations:  ASTM F1807, ASTM F2159.
@ Certified Bow Superpex tubing has a blue, red, or white outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing! % * ^ ¢ §
 
PEX 5006
 
Oxypex
 
ASTM F876/F877
1/4" - 2" SDR 9

! Product may or may not bear the NSF U.P. code marking.
% Certified Oxypex tubing has a red outer layer.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing% ¢
 
PEX
 
Oxypex
 
CSA B137.5
1/4" - 2" SDR 9

% Certified Oxypex tubing has a red outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.



 
Calefactio Solutions Inc 
1120 Michele bohec
Blainville, QC J7C 5N5 
Canada 
450-951-0818

Facility : # 1 China

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ¢ §
 
PEX
 
CALEFACTIO
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * §
 
PEX 5006
 
CALEFACTIO
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
Cash Acme / Reliance Worldwide 
2400 7th Avenue Southwest
Cullman, AL 35055 
United States 
256-775-8184

Facility : Middlefield, OH

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing# * @ ^ ¢ § +++ [G]
 
PEX 3006
 
SHARKBITE®
 
ASTM F876/F877
1/2" - 1" SDR 9

# Authorized for orange color.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * @ ¢ +++ [G]
 
PEX
 
SHARKBITE®
 
CSA B137.5
1/2" - 1" SDR 9

# Authorized for orange color.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing# * @ ^ ¢ §
 
PEX 3006
 
SHARKBITE®
 
ASTM F876/F877
1/2" - 1" SDR 9

# Authorized for orange color.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# * @ ¢
 
PEX
 
SHARKBITE®
 
CSA B137.5
1/2" - 1" SDR 9

# Authorized for orange color.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.



 
CB Supplies Ltd. 
3325 190th Street
Surrey, BC V3S 0L5 
Canada 
800-747-3739 
604-431-5024

Facility : Surrey, British Columbia, Canada

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ ? @ ^ ~ ¢ § +++ [G]
 
PEX 5306
 
CANFLEX™
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ @ ^ ~ ¢ § +++ [3] [G]
 
PEX
 
CANFLEX™
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [G]
 
PEX 5306
 
CANPEX™
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ @ ^ ~ ¢ § +++ [3] [G]
 
PEX
 
CANPEX™
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ ^ ~ ¢ £ § +++ [G]
 
PEX 5006
 
CanPEX Barrier
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ ^ ~ ¢ £ § +++ [3] [G]
 
PEX
 
CanPEX Barrier
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ ^ ~ ¢ £ § +++ [G]
 
PEX 5006
 
CanPEX OXY Barrier
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ ^ ~ ¢ £ § +++ [3] [G]
 
PEX
 
CanPEX OXY Barrier
 
CSA B137.5
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ^ ~ ¢ § µ +++ [G]
 
PEX 5306
 
CanPEX Ultra
 
ASTM F876/F877
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ^ ~ ¢ § µ +++ [3] [G]
 
PEX
 
CanPEX Ultra
 
CSA B137.5
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [G]
 
PEX 5306
 
CANPEX™ UV
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [3] [G]
 
PEX
 
CANPEX™ UV
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [G]
 
PEX 5306
 
CANPEX™ UV +
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [3] [G]
 
PEX
 
CANPEX™ UV +
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [G]
 
PEX 5306
 
CANPEX™ UV + MD
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [3] [G]
 
PEX
 
CANPEX™ UV + MD
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [G]
 
PEX 5306
 
CANPEX™ UV Plus
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [3] [G]
 
PEX
 
CANPEX™ UV Plus
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [G]
 
PEX 5306
 
CANPEX™ UV Plus MD
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [3] [G]
 
PEX
 
CANPEX™ UV Plus MD
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [G]
 
PEX 5306
 
CANPLUMB™
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ @ ^ ~ ¢ § +++ [3] [G]
 
PEX
 
CANPLUMB™
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ ^ ~ ¢ £ § +++ [G]
 
PEX 5006
 
CanRay
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ ^ ~ ¢ £ § +++ [3] [G]
 
PEX
 
CanRay
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ ^ ~ ¢ £ § Þ
 
PEX 5006
 
Embassy / LiquiPEX w/O2 Barrier
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
Þ Product is Certified to the International Plumbing Code™. Installation in accordance
  with the manufacturer's instructions and the requirements of the latest edition of the
  International Plumbing Code™.

Tubing! # $ ^ ~ ¢ £ § Þ [3]
 
PEX
 
Embassy / LiquiPEX w/O2 Barrier
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
Þ Product is Certified to the International Plumbing Code™. Installation in accordance
  with the manufacturer's instructions and the requirements of the latest edition of the
  International Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing! # $ ^ ~ ¢ £ § +++ [G]
 
PEX 5006
 
RadiantMax
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ ^ ~ ¢ £ § +++ [3] [G]
 
PEX
 
RadiantMax
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ? @ ^ ~ ¢ § +++ [G]
 
PEX 5306
 
Vanex
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ @ ^ ~ ¢ § +++ [3] [G]
 
PEX
 
Vanex
 
CSA B137.5
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ ^ ~ ¢ £ § +++ [3] [G]
 
PEX
 
Vanex Barrier
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! # $ ^ ~ ¢ £ § +++ [G]
 
PEX 5006
 
Vanex Barrier
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ^ ~ ¢ § µ +++ [G]
 
PEX 5306
 
Vanex Ultra
 
ASTM F876/F877
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# $ ^ ~ ¢ § µ +++ [3] [G]
 
PEX
 
Vanex Ultra
 
CSA B137.5
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ ? @ ^ ~ ¢ §
 
PEX 5306
 
CANFLEX™
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ @ ^ ~ ¢ § [3]
 
PEX
 
CANFLEX™
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing# $ ? @ ^ ~ ¢ §
 
PEX 5306
 
CANPEX™
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ @ ^ ~ ¢ § [3]
 
PEX
 
CANPEX™
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing! # $ ^ ~ ¢ £ §
 
PEX 5006
 
CanPEX Barrier
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! # $ ^ ~ ¢ £ § [3]
 
PEX
 
CanPEX Barrier
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing! # $ ^ ~ ¢ £ §
 
PEX 5006
 
CanPEX OXY Barrier
 
ASTM F876/F877
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! # $ ^ ~ ¢ £ § [3]
 
PEX
 
CanPEX OXY Barrier
 
CSA B137.5
1/4" - 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing# $ ^ ~ ¢ § µ
 
PEX 5306
 
CanPEX Ultra
 
ASTM F876/F877
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.

Tubing# $ ^ ~ ¢ § µ [3]
 
PEX
 
CanPEX Ultra
 
CSA B137.5
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing# $ ? @ ^ ~ ¢ §
 
PEX 5306
 
CANPEX™ UV
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ ? @ ^ ~ ¢ § [3]
 
PEX
 
CANPEX™ UV
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing# $ ? @ ^ ~ ¢ §
 
PEX 5306
 
CANPEX™ UV +
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ ? @ ^ ~ ¢ § [3]
 
PEX
 
CANPEX™ UV +
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing# $ ? @ ^ ~ ¢ §
 
PEX 5306
 
CANPEX™ UV + MD
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ ? @ ^ ~ ¢ § [3]
 
PEX
 
CANPEX™ UV + MD
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing# $ ? @ ^ ~ ¢ §
 
PEX 5306
 
CANPEX™ UV Plus
 
ASTM F876/F877
3/8" - 2' SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ ? @ ^ ~ ¢ § [3]
 
PEX
 
CANPEX™ UV Plus
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing# $ ? @ ^ ~ ¢ §
 
PEX 5306
 
CANPEX™ UV Plus MD
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ ? @ ^ ~ ¢ § [3]
 
PEX
 
CANPEX™ UV Plus MD
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing# $ ? @ ^ ~ ¢ §
 
PEX 5306
 
CANPLUMB™
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ @ ^ ~ ¢ § [3]
 
PEX
 
CANPLUMB™
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing! # $ ^ ~ ¢ £ §
 
PEX 5006
 
CanRay
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! # $ ^ ~ ¢ £ § [3]
 
PEX
 
CanRay
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing! # $ ^ ~ ¢ £ § Þ
 
PEX 5006
 
Embassy / LiquiPEX w/O2 Barrier
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
Þ Product is Certified to the International Plumbing Code™.  Installation in accordance
  with the manufacturer’s instructions and the requirements of the latest edition of the
  International Plumbing Code™.

Tubing! # $ ^ ~ ¢ £ § Þ [3]
 
PEX
 
Embassy / LiquiPEX w/O2 Barrier
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
Þ Product is Certified to the International Plumbing Code™.  Installation in accordance
  with the manufacturer’s instructions and the requirements of the latest edition of the
  International Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing! # $ ^ ~ ¢ £ §
 
PEX 5006
 
RadiantMax
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! # $ ^ ~ ¢ £ § [3]
 
PEX
 
RadiantMax
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing# $ ? @ ^ ~ ¢ §
 
PEX 5306
 
Vanex
 
ASTM F876/F877
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# $ @ ^ ~ ¢ § [3]
 
PEX
 
Vanex
 
CSA B137.5
3/8" - 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing! # $ ^ ~ ¢ £ §
 
PEX 5006
 
Vanex Barrier
 
ASTM F876/F877
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! # $ ^ ~ ¢ £ § [3]
 
PEX
 
Vanex Barrier
 
CSA B137.5
1/4" – 2" SDR 9

! Orange, natural, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.

Tubing# $ ^ ~ ¢ § µ
 
PEX 5306
 
Vanex Ultra
 
ASTM F876/F877
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.

Tubing# $ ^ ~ ¢ § µ [3]
 
PEX
 
Vanex Ultra
 
CSA B137.5
3/8" – 2" SDR 9

# Pipe tested as a system using VI fittings manufactured by CB Supplies Ltd. 
  Installation/assembly instructions titled “Installation Guidelines for CB Supplies Ltd.
  Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s):  ASTM F1807,
    ASTM F2159.



 
Cirque Sales & Distribution, Inc 
13504 Northeast 84th Street
Suite 103-267 
Vancover, WA 98682 
United States 
888-710-6667 
360-326-7003

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe$ * ^ § +++
 
PEX 1006
 
SafePEX®
 
ASTM F876/F877
3/8" - 2" SDR 9

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ ¢ § +++
 
PEX 1006
 
SafePEX®
 
CSA B137.5
3/8" - 2"

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX Pro Blue UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX Pro Blue UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX Pro Red UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX Pro Red UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX Pro White UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX Pro White UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Conbraco Industries, Inc. 
701 Matthews-Mint Hill Road
Matthews, NC 28105 
United States 
704-847-9191

Facility : Foshan, China

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ * ^ § +++ [G]
 
PEX
 
Apollo
 
ASTM E84

68PXB100012 1/2"
Flame Spread Index <= 25   Flame Spread Index <= 25  

68PXB100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB1210 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB3410 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR1210 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR3410 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW5012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW5034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW51 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW538 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ & § +++ [G]
 
PEX
 
Apollo
 
CAN/ULC S102.2

68PXB100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB10012 1/2"
Flame Spread Rating <= 25   Smoke Developed Classification <= 50  

APPB10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB1210 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB3410 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR1210 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR3410 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW5012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW5034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW51 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW538 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
Apollo
 
ASTM F876/F877

>= 1/8" SDR 9
APPW514 1/4"   APPW538 3/8"   APPB10012 1/2"   APPB1210 1/2"  
APPB2012 1/2"   APPB30012 1/2"   APPB50012 1/2"   APPR10012 1/2"  
APPR1210 1/2"   APPR2012 1/2"   APPR30012 1/2"   APPR50012 1/2"  
APPW10012 1/2"   APPW1012 1/2"   APPW2012 1/2"   APPW30012 1/2"  
APPW50012 1/2"   APPW512 1/2"   APPB10034 3/4"   APPB2034 3/4"  
APPB30034 3/4"   APPB3410 3/4"   APPB50034 3/4"   APPR10034 3/4"  
APPR2034 3/4"   APPR30034 3/4"   APPR3410 3/4"   APPR50034 3/4"  
APPW10034 3/4"   APPW1034 3/4"   APPW2034 3/4"   APPW30034 3/4"  
APPW50034 3/4"   APPW534 3/4"   APPB1001 1"   APPB3001 1"  
APPR1001 1"   APPR3001 1"   APPW1001 1"   APPW3001 1"  
APPW51 1"  

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
Apollo
 
AWWA C904

1/2" - 1 1/2" SDR 9
APPR1210 1/2"   APPB10012 1/2"   APPB1210 1/2"   APPB2012 1/2"  
APPB30012 1/2"   APPB50012 1/2"   APPR10012 1/2"   APPR2012 1/2"  
APPR30012 1/2"   APPR50012 1/2"   APPW10012 1/2"   APPW1012 1/2"  
APPW2012 1/2"   APPW30012 1/2"   APPW50012 1/2"   APPW512 1/2"  
APPB10034 3/4"   APPB2034 3/4"   APPB30034 3/4"   APPB3410 3/4"  
APPB50034 3/4"   APPR10034 3/4"   APPR2034 3/4"   APPR30034 3/4"  
APPR3410 3/4"   APPR50034 3/4"   APPW10034 3/4"   APPW1034 3/4"  
APPW2034 3/4"   APPW30034 3/4"   APPW50034 3/4"   APPW534 3/4"  
APPB1001 1"   APPB3001 1"   APPR1001 1"   APPR3001 1"  
APPW1001 1"   APPW3001 1"   APPW51 1"  

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ ¢ § +++ [G]
 
PEX 5006
 
Apollo
 
CSA B137.5

>= 1/8" SDR 9
APPB1210 1/2"   APPW514 1/4"   APPW538 3/8"   APPB10012 1/2"  
APPB2012 1/2"   APPB30012 1/2"   APPB50012 1/2"   APPR10012 1/2"  
APPR1210 1/2"   APPR2012 1/2"   APPR30012 1/2"   APPR50012 1/2"  
APPW10012 1/2"   APPW1012 1/2"   APPW2012 1/2"   APPW30012 1/2"  
APPW50012 1/2"   APPW512 1/2"   APPB10034 3/4"   APPB2034 3/4"  
APPB30034 3/4"   APPB3410 3/4"   APPB50034 3/4"   APPR10034 3/4"  
APPR2034 3/4"   APPR30034 3/4"   APPR3410 3/4"   APPR50034 3/4"  
APPW10034 3/4"   APPW1034 3/4"   APPW2034 3/4"   APPW30034 3/4"  
APPW50034 3/4"   APPW534 3/4"   APPB1001 1"   APPB3001 1"  
APPR1001 1"   APPR3001 1"   APPW1001 1"   APPW3001 1"  
APPW51 1"  

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * § +++ [G]
 
PEX 5006
 
Apollo
 
ASTM F876/F877
APPW14RISER 1/4"   APPW2512 1/2"   APPW5012 1/2"   APPR212 1/2"  
APPB212 1/2"   APPW212 1/2"   APPR512 1/2"   APPB512 1/2"  
APPR1210 1/2"   APPB1210 1/2"   68PXR10012 1/2"   68PXB10012 1/2"  
68PXW10012 1/2"   68PXR30012 1/2"   68PXB30012 1/2"   68PXW30012 1/2"  
68PXR50012 1/2"   68PXB50012 1/2"   68PXW50012 1/2"   68PXR100012 1/2"  
68PXB100012 1/2"   68PXW100012 1/2"   68PXR1012 1/2"   68PXB1012 1/2"  
68PXW1012 1/2"   68PXR2012 1/2"   68PXB2012 1/2"   68PXW2012 1/2"  
APPW1038 3/8"   68PXR10038 3/8"   68PXB10038 3/8"   68PXW10038 3/8"  
68PXR50038 3/8"   68PXB50038 3/8"   68PXW50038 3/8"   68PXR100038 3/8"  
68PXB100038 3/8"   68PXW100038 3/8"   APPW2534 3/4"   APPW5034 3/4"  
APPR234 3/4"   APPB234 3/4"   APPW234 3/4"   APPR534 3/4"  
APPB534 3/4"   APPR3410 3/4"   APPB3410 3/4"   68PXR10034 3/4"  
68PXB10034 3/4"   68PXW10034 3/4"   68PXR30034 3/4"   68PXB30034 3/4"  
68PXW30034 3/4"   68PXR50034 3/4"   68PXB50034 3/4"   68PXW50034 3/4"  
68PXR1034 3/4"   68PXB1034 3/4"   68PXW1034 3/4"   68PXR2034 3/4"  
68PXB2034 3/4"   68PXW2034 3/4"   APPB101 1"   APPW101 1"  
APPW201 1"   68PXR1001 1"   68PXB1001 1"   68PXW1001 1"  
68PXR3001 1"   68PXB3001 1"   68PXW3001 1"   68PXR5001 1"  
68PXB5001 1"   68PXW5001 1"   68PXR201 1"   68PXB201 1"  
68PXW201 1"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * § +++ [G]
 
PEX 5006
 
Apollo
 
AWWA C904
APPW2512 1/2"   APPW5012 1/2"   APPR212 1/2"   APPB212 1/2"  
APPW212 1/2"   APPR512 1/2"   APPB512 1/2"   APPR1210 1/2"  
APPB1210 1/2"   68PXR10012 1/2"   68PXB10012 1/2"   68PXW10012 1/2"  
68PXR30012 1/2"   68PXB30012 1/2"   68PXW30012 1/2"   68PXR50012 1/2"  
68PXB50012 1/2"   68PXW50012 1/2"   68PXR100012 1/2"   68PXB100012 1/2"  
68PXW100012 1/2"   68PXR1012 1/2"   68PXB1012 1/2"   68PXW1012 1/2"  
68PXR2012 1/2"   68PXB2012 1/2"   68PXW2012 1/2"   APPW2534 3/4"  
APPW5034 3/4"   APPR234 3/4"   APPB234 3/4"   APPW234 3/4"  
APPR534 3/4"   APPB534 3/4"   APPR3410 3/4"   APPB3410 3/4"  
68PXR10034 3/4"   68PXB10034 3/4"   68PXW10034 3/4"   68PXR30034 3/4"  
68PXB30034 3/4"   68PXW30034 3/4"   68PXR50034 3/4"   68PXB50034 3/4"  
68PXW50034 3/4"   68PXR1034 3/4"   68PXB1034 3/4"   68PXW1034 3/4"  
68PXR2034 3/4"   68PXB2034 3/4"   68PXW2034 3/4"   APPB101 1"  
APPW101 1"   APPW201 1"   68PXR1001 1"   68PXB1001 1"  
68PXW1001 1"   68PXR3001 1"   68PXB3001 1"   68PXW3001 1"  
68PXR5001 1"   68PXB5001 1"   68PXW5001 1"   68PXR201 1"  
68PXB201 1"   68PXW201 1"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# § +++ [G]
 
PEX 5006
 
Apollo
 
CSA B137.5
APPW14RISER 1/4"   APPW2512 1/2"   APPW5012 1/2"   APPR212 1/2"  
APPB212 1/2"   APPW212 1/2"   APPR512 1/2"   APPB512 1/2"  
APPR1210 1/2"   APPB1210 1/2"   68PXR10012 1/2"   68PXB10012 1/2"  
68PXW10012 1/2"   68PXR30012 1/2"   68PXB30012 1/2"   68PXW30012 1/2"  
68PXR50012 1/2"   68PXB50012 1/2"   68PXW50012 1/2"   68PXR100012 1/2"  
68PXB100012 1/2"   68PXW100012 1/2"   68PXR1012 1/2"   68PXB1012 1/2"  
68PXW1012 1/2"   68PXR2012 1/2"   68PXB2012 1/2"   68PXW2012 1/2"  
APPW1038 3/8"   68PXR10038 3/8"   68PXB10038 3/8"   68PXW10038 3/8"  
68PXR50038 3/8"   68PXB50038 3/8"   68PXW50038 3/8"   68PXR100038 3/8"  
68PXB100038 3/8"   68PXW100038 3/8"   APPW2534 3/4"   APPW5034 3/4"  
APPR234 3/4"   APPB234 3/4"   APPW234 3/4"   APPR534 3/4"  
APPB534 3/4"   APPR3410 3/4"   APPB3410 3/4"   68PXR10034 3/4"  
68PXB10034 3/4"   68PXW10034 3/4"   68PXR30034 3/4"   68PXB30034 3/4"  
68PXW30034 3/4"   68PXR50034 3/4"   68PXB50034 3/4"   68PXW50034 3/4"  
68PXR1034 3/4"   68PXB1034 3/4"   68PXW1034 3/4"   68PXR2034 3/4"  
68PXB2034 3/4"   68PXW2034 3/4"   APPB101 1"   APPW101 1"  
APPW201 1"   68PXR1001 1"   68PXB1001 1"   68PXW1001 1"  
68PXR3001 1"   68PXB3001 1"   68PXW3001 1"   68PXR5001 1"  
68PXB5001 1"   68PXW5001 1"   68PXR201 1"   68PXB201 1"  
68PXW201 1"  

# Certified for black, blue, natural, orange, red, and white.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * §
 
PEX 5006
 
Apollo
 
ASTM F876/F877

>= 1/8" SDR 9
APPOB2512 1/2"   APPOB30012 1/2"   APPOB10034 3/4"   APPOB30034 3/4"  

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * ¢ §
 
PEX 5006
 
Apollo
 
CSA B137.5

>= 1/8" SDR 9
APPOB2512 1/2"   APPOB30012 1/2"   APPOB10034 3/4"   APPOB30034 3/4"  

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# * § +++
 
PEX 5006
 
Apollo
 
ASTM F876/F877
APPOB10012 1/2"   68PXPOB30012 1/2"   68PXPOB50012 1/2"   68PXPOB100012 1/2"  
APPOB1034 3/4"   68PXPOB30034 3/4"   68PXPOB50034 3/4"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing# * § +++
 
PEX 5006
 
Apollo
 
CSA B137.5
APPOB10012 1/2"   68PXPOB30012 1/2"   68PXPOB50012 1/2"   68PXPOB100012 1/2"  
APPOB1034 3/4"   68PXPOB30034 3/4"   68PXPOB50034 3/4"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).



 
Conbraco Industries, Inc. 
701 Matthews-Mint Hill Road
Matthews, NC 28105 
United States 
704-847-9191

Facility : # 2 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing@ ^ ++ [G]
 
PEX 5306
 
Apollo®
 
ASTM F876/F877
1/2" SDR 9
3/4" SDR 9
1" SDR 9

@ Black inner layer with blue, red, or white outer layer.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ +++ [1] [G]
 
PEX 5106
 
Apollo®
 
ASTM F876/F877
1/4" - 2" (CTS) SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Pipe can be manufactured in red, white, or blue.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ @ ^ ¢ ++ [G]
 
PEX 5306
 
Apollo®
 
CSA B137.5
1/2" SDR 9
3/4" SDR 9
1" SDR 9

$ Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM
  F2159, ASTM F2098, and ASTM F1960.
@ Black inner layer with blue, red, or white outer layer.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ ^ ¢ +++ [1] [G]
 
PEX 5106
 
Apollo®
 
CSA B137.5
1/4" - 2" (CTS) SDR 9

$ Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM
  F2159, ASTM F2098, and ASTM F1960.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Pipe can be manufactured in red, white, or blue.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Conbraco Industries, Inc. 
701 Matthews-Mint Hill Road
Matthews, NC 28105 
United States 
888-229-2874 
704-841-6167
Visit this company's website

Facility : # 8 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe$ * ^ § +++ [G]
 
PEX 3006
 
Apollo
 
ASTM F876/F877
3/8" - 2" SDR 9

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe$ * ^ § +++ [G]
 
PEX 3006
 
Apollo
 
AWWA C904
1/2" - 2" SDR 9

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe$ * ^ ¢ § +++ [G]
 
PEX
 
Apollo
 
CSA B137.5
3/8" - 2" SDR 9

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Elkhart Supply Corporation 
1126 Kent Street
Elkhart, IN 46514-1740 
United States 
574-264-4156

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe$ * ^ § +++
 
PEX 1006
 
SafePEX®
 
ASTM F876/F877
3/8" - 2" SDR 9

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ ¢ § +++
 
PEX 1006
 
SafePEX®
 
CSA B137.5
3/8" - 2" SDR

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX Pro Blue UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX Pro Blue UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX Pro Red UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX Pro Red UV-Shield
 
CSA B137
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX Pro White UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX Pro White UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Everflow Supplies Inc. 
100 Middlesex Avenue
Carteret, NJ 07008 
United States 
908-436-1100

Facility : Foshan, China

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ § +++
 
PEX 5006
 
PEXFLOW™
 
ASTM F876/F877
1/2" - 1" SDR 9

$ Certified for blue and red without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing$ * ^ ¢ § +++
 
PEX
 
PEXFLOW™
 
CSA B137.5
1/2" - 1" SDR 9

$ Certified for blue and red without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * §
 
PEX 5006
 
PEXFLOW™
 
ASTM F876/F877
1/2" - 1" SDR 9

$ Certified for blue and red with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * ¢ §
 
PEX
 
PEXFLOW™
 
CSA B137.5
1/2" - 1" SDR 9

$ Certified for blue and red with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.


 
Everhot Inc. 
5407 Foster Avenue
Brooklyn, NY 11234 
United States 
347-492-7660

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ *
 
PEX
 
Everhot
 
ASTM E84

3/8", 1/2" - 2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing$ &
 
PEX
 
Everhot
 
CAN/ULC S102.2

3/8", 1/2" - 2"
Flame Spread Rating <= 25   Smoke Developed Classification <= 50  

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
Everhot
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
Everhot
 
AWWA C904
1/2" - 1 1/2" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ ¢ § +++ [G]
 
PEX
 
Everhot
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * § +++ [G]
 
PEX / AL / PEX
 
Everhot
 
ASTM F1281
1/2" - 1"

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * ¢ § +++ [G]
 
PEX / AL / PEX
 
Everhot
 
CSA B137.10
1/2" - 1"

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ¢ §
 
PEX
 
Everhot
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for blue, natural, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * §
 
PEX 5006
 
Everhot
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for blue, natural, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# * §
 
PEX / AL / PEX
 
Everhot
 
ASTM F1281
1/2" - 1"

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# * ¢ §
 
PEX / AL / PEX
 
Everhot
 
CSA B137.10
1/2" - 1"

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
EZ Flo International 
1605 Research Circle
Rockwall, TX 75032 
United States 
800-486-5256
Visit this company's website

Facility : # 2 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing# @ ^ ¢ § +++ [G]
 
PEX 3006
 
Eastman® PEX
 
ASTM F876/F877
1/8" - 1 1/4" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing@ ^ ¢ § +++ [G]
 
PEX 3006
 
Eastman® PEX
 
ASTM F876/F877
1/8" CTS x 1/4" OD SDR 9

@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# @ ¢ +++ [G]
 
PEX
 
Eastman® PEX
 
CSA B137.5
1/8" - 1 1/4" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing@ ¢ +++ [G]
 
PEX
 
Eastman® PEX
 
CSA B137.5
1/8" CTS x 1/4" OD SDR 9

@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# @ ^ ¢ § +++ [G]
 
PEX 3006
 
Merflex PEX
 
ASTM F876/F877
1/8" - 1 1/4" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing@ ^ ¢ § +++ [G]
 
PEX 3006
 
Merflex PEX
 
ASTM F876/F877
1/8" CTS x 1/4" OD SDR 9

@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# @ ¢ +++ [G]
 
PEX
 
Merflex PEX
 
CSA B137.5
1/8" - 1 1/4" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing@ ¢ +++ [G]
 
PEX
 
Merflex PEX
 
CSA B137.5
1/8" CTS x 1/4" OD SDR 9

@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Foshan Rifeng Enterprise Co., Ltd. 
5th/F, Rifeng Building
16 Zumiao Road 
Foshan, Guangdong 528000 
China 
86 757 8230 1768

Facility : Foshan, China

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ *
 
PEX
 
Rifeng
 
ASTM E84

3/8", 1/2" - 2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing$ &
 
PEX
 
Rifeng
 
CAN/ULC S102.2

3/8", 1/2" - 2"
Flame Spread Rating <= 25   Smoke Developed Classification <= 50  

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
Rifeng
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ § +++ [G]
 
PEX 5006
 
Rifeng
 
AWWA C904
1/2" - 1 1/2" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ * ^ ¢ § +++ [G]
 
PEX
 
Rifeng
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# & * § +++ [G]
 
PEX / AL / PEX
 
Rifeng
 
ASTM F1281
1/2" - 1"  

# Certified for black, blue, natural, orange, red, and white.
& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
  ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * ¢ § +++ [G]
 
PEX / AL / PEX
 
Rifeng
 
CSA B137.10
1/2" - 1"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ¢ §
 
PEX
 
Rifeng
 
CSA B137.5
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ * §
 
PEX 5006
 
Rifeng
 
ASTM F876/F877
>= 1/8" SDR 9

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# * §
 
PEX / AL / PEX
 
Rifeng
 
ASTM F1281
1/2" - 1"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# * ¢ §
 
PEX / AL / PEX
 
Rifeng
 
CSA B137.10
1/2" - 1"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
GE Appliances, a Haier Company 
Appliance Park
Louisville, KY 40225 
United States 
502-452-3332
Visit this company's website

Facility : # 1 USA

Potable Water - Appurtenances

Product Type   Material Type   Trade Name   Product Standard

Refrigerator Supply Line# & ¢ § [G]
 
PEX
 
GE SmartConnect™
 
ASME A112.18.6/CSA B125.6
1/8" C.T.S.

# This product may be marked via a flag type label.
& Certified up to 8 feet in length.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Giacomini S.P.A. 
Via Per Alzo 39
28017 S. Maurizio D' Opaglio (NO) 
Italy 
39 0322 923372
Visit this company's website

Facility : D'Opaglio (NO), Italy

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe
 
PEX
 
L996 PE-X Pipe
 
ASTM F876/877
3/8" - 1"

Pipe
 
PEX
 
L996 PE-X Pipe
 
CSA B137.5
3/8" - 1"



 
Golan Plastic Products Ltd. 
Kibbutz Shaar Hagolan
M.P. Jordan Valley 15145 
Israel 
972 46 677432
Visit this company's website

Facility : Jordan Valley, Israel

Oil and Gas Producing Applications - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing
 
PEX 0006
 
Pexgol PE-Xa Black
 
ASTM F2905
3" - 18" SDR 7.3
3" - 20" SDR 8.3
3" - 24" SDR 9
3" - 36" SDR 11
3" - 36" SDR 13.5
3" - 48" SDR 15.5
3" - 54" SDR 17
3" - 54" SDR 21
16 mm - 355 mm SDR 6
16 mm - 450 mm SDR 7.4
16 mm - 800 mm SDR 9
16 mm - 630 mm SDR 11
16 mm - 630 mm SDR 13.6
16 mm - 630 mm SDR 16.2
16 mm - 630 mm SDR 17
16 mm - 630 mm SDR 21


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing^ ¢ § $$ +++
 
PEX 1006
 
AquaHeat PE-Xa Black
 
AWWA C904
1/2" - 3" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 1006
 
AquaHeat PE-Xa Natural
 
ASTM F2788
1/2" - 14" SDR 6 DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" DR 9
16 mm - 630 mm DR 9
3/4" - 25" DR 11
20 mm - 630 mm DR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" DR 17
32 mm - 630 mm DR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
AquaHeat PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
AquaHeat PE-Xa Natural
 
CSA B137.5
3/8" - 6" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
AquaHeat PE-Xa Natural
 
AWWA C904
1/2" - 3" DR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaHeat PE-Xc Black
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" DR 9
16 mm - 25 mm DR 9
3/4" - 1" DR 11
20 mm - 25 mm DR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
AquaHeat PE-Xc Black
 
ASTM F876/F877
1/4" - 1" DR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaHeat PE-Xc Blue
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" DR 9
16 mm - 25 mm DR 9
3/4" - 1" DR 11
20 mm - 25 mm DR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
AquaHeat PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" DR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaHeat PE-Xc Natural
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" DR 9
16 mm - 25 mm DR 9
3/4" - 1" DR 11
20 mm - 25 mm DR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
AquaHeat PE-Xc Natural
 
ASTM F876/F877
14" - 1" DR 6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaHeat PE-Xc Red
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" DR 9
16 mm - 25 mm DR 9
3/4" - 1" DR 11
20 mm - 25 mm DR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
AquaHeat PE-Xc Red
 
ASTM F876/F877
1/4" - 1" DR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Sioux Chief PE-Xa Black
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
AquaSeal PE-Xa Black
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 1006
 
AquaSeal PE-Xa Natural
 
ASTM F2788
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
AquaSeal PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
AquaSeal PE-Xa Natural
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
AquaSeal PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaSeal PE-Xc Black
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
AquaSeal PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaSeal PE-Xc Blue
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
AquaSeal PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaSeal PE-Xc Natural
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
AquaSeal PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
AquaSeal PE-Xc Red
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
AquaSeal PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
HeatFlow PEX PE-Xa Black
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 1006
 
HeatFlow PEX PE-Xa Natural
 
ASTM F2788
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ $$ +++
 
PEX 1006
 
HeatFlow PEX PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
HeatFlow PEX PE-Xa Natural
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
HeatFlow PEX PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
HeatFlow PEX PE-Xc Black
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
HeatFlow PEX PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
HeatFlow PEX PE-Xc Blue
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
HeatFlow PEX PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
HeatFlow PEX PE-Xc Red
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
HeatFlow PEX PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
HeatFlow PEX PE-Xc Natural
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
HeatFlow PEX PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Pexgol PE-Xa Black
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Pexgol PE-Xa Black
 
ASTM F876/F877
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing* ^ ¢ § $$ +++
 
PEX 1006
 
Pexgol PE-Xa Black
 
ASTM F2788/F2788M
3" SDR 9
16 mm - 76 mm SDR 9
3" - 14" SDR 6 DR 6
16 mm - 355 mm DR 6
3" - 18" DR 7.4
16 mm - 450 mm DR 7.4
3" - 25" DR 9
16 mm - 630 mm DR 9
3" - 25" DR 11
20 mm - 630 mm DR 11
3" - 25" DR 13.6
25 mm - 630 mm DR 13.6
3" - 25" DR 16.2
32 mm - 630 mm DR 16.2
3" - 25" DR 17
32 mm - 630 mm DR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Pexgol PE-Xa Black
 
CSA B137.5
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 1006
 
Pexgol PE-Xa Natural
 
ASTM F2788
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
Pexgol PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Pexgol PE-Xa Natural
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
Pexgol PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Pexgol PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 1006
 
Sioux Chief PE-Xa Natural
 
ASTM F2788
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Pexgol PE-Xc Black
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Pexgol PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Pexgol PE-Xc Blue
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Pexgol PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Pexgol PE-Xc Red
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Pexgol PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Pexgol PE-Xc Natural
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Plumber Friendly PE-Xa Black
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 1006
 
Plumber Friendly PE-Xa Natural
 
ASTM F2788
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
Plumber Friendly PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Plumber Friendly PE-Xa Natural
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
Sioux Chief PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
Plumber Friendly PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Plumber Friendly PE-Xc Black
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Plumber Friendly PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Plumber Friendly PE-Xc Blue
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm SDR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Plumber Friendly PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Plumber Friendly PE-Xc Natural
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" DR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Plumber Friendly PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Plumber Friendly PE-Xc Red
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm SDR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Plumber Friendly PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Slant/Fin Heating PE-Xa Black
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
Slant/Fin Heating PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Slant/Fin Heating PE-Xa Natural
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
Sioux Chief PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
Slant/Fin Heating PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Heating PE-Xc Black
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Slant/Fin Heating PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Heating PE-Xc Blue
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" Sch 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Slant/Fin Heating PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 1006
 
Slant/Fin Heating PE-Xa Natural
 
ASTM F2788
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 16.2
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Heating PE-Xc Natural
 
ASTM F2788
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6
1/2" - 1" SDR 9
16 mm - 25 mm DR 7.4
1/2" - 1" DR 7.4
16 mm - 25 mm DR 6
1/2" - 1" DR 6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Slant/Fin Heating PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Slant/Fin Heating PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Heating PE-Xc Red
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Slant/Fin Plumbing PE-Xa Black
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Sioux Chief PE-Xa Natural
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
Slant/Fin Plumbing PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 1006
 
Slant/Fin Plumbing PE-Xa Natural
 
ASTM F2788
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Slant/Fin Plumbing PE-Xa Natural
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
Slant/Fin Plumbing PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Black
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm SIDR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Blue
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Natural
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Sioux Chief PE-Xc Black
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Red
 
ASTM F2788
1/2" - 1" DR 6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Sioux Chief PE-Xc Black
 
ASTM F2788
1/2" - 1" DR 7.4

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Red
 
ASTM F2788
16 mm - 25 mm DR 6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Sioux Chief PE-Xc Black
 
ASTM F2788
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Red
 
ASTM F2788
1/2" - 1" DR 7.4

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Sioux Chief PE-Xc Black
 
ASTM F2788
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Red
 
ASTM F2788
16 mm - 25 mm DR 7.4

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Sioux Chief PE-Xc Black
 
ASTM F2788
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Red
 
ASTM F2788
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Terratherma PE-Xa Black
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
Terratherma PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ ¢ $$ +++
 
PEX 1006
 
Terratherma PE-Xa Natural
 
ASTM F2788
1/2" - 14" DR 6
16 mm - 355 mm DR 6
1/2" - 18" DR 7.4
16 mm - 450 mm DR 7.4
1/2" - 25" SDR 9
16 mm - 630 mm SDR 9
3/4" - 25" SDR 11
20 mm - 630 mm SDR 11
1" - 25" DR 13.6
25 mm - 630 mm DR 13.6
1 1/4" - 25" DR 16.2
32 mm - 630 mm DR 16.2
1 1/4" - 25" SDR 17
32 mm - 630 mm SDR 17

* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Tubing^ ¢ § $$ +++
 
PEX 1006
 
Terratherma PE-Xa Natural
 
AWWA C904
1/2" - 3" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe^ ¢ § $$ +++
 
PEX 1006
 
Terratherma PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Terratherma PE-Xc Black
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Terratherma PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Terratherma PE-Xc Blue
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Terratherma PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Terratherma PE-Xc Natural
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Terratherma PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Sioux Chief PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Terratherma PE-Xc Red
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Terratherma PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Sioux Chief PE-Xc Blue
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Sioux Chief PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Sioux Chief PE-Xc Natural
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Sioux Chief PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ +++
 
PEX 5006
 
Sioux Chief PE-Xc Red
 
ASTM F2788
1/2" - 1" DR 6
16 mm - 25 mm DR 6
1/2" - 1" DR 7.4
16 mm - 25 mm DR 7.4
1/2" - 1" SDR 9
16 mm - 25 mm SDR 9
3/4" - 1" SDR 11
20 mm - 25 mm SDR 11
1" DR 13.6
25 mm DR 13.6

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
* Barrier Pipes only Certified up to 160mm (6").
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ ^ § +++
 
PEX 5006
 
Sioux Chief PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe¢ § $$
 
PEX 1006
 
Sioux Chief PEX PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe¢ § $$
 
PEX 1006
 
Sioux Chief PEX PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
Sioux Chief PEX PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Sioux Chief PEX PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Sioux Chief PEX PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Sioux Chief PEX PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Slant/Fin Heating PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Slant/Fin Heating PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 1006
 
Slant/Fin Heating PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe¢ § $$
 
PEX 1006
 
Slant/Fin Heating PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
Slant/Fin Heating PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Slant/Fin Heating PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 1006
 
Slant/Fin Plumbing PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe¢ § $$
 
PEX 1006
 
Slant/Fin Plumbing PE-Xa Natural
 
CSA B137.5

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Slant/Fin Plumbing PE-Xc Red
 
ASTM F876/F877
3/8" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 1006
 
Pexgol PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe¢ § $$
 
PEX 1006
 
Pexgol PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
Pexgol PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Pexgol PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Pexgol PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Pexgol PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 1006
 
Terratherma PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe¢ § $$
 
PEX 1006
 
Terratherma PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
Terratherma PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Terratherma PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Terratherma PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Terratherma PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 1006
 
AquaSeal PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe¢ § $$
 
PEX 1006
 
AquaSeal PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
AquaSeal PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
AquaSeal PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
AquaSeal PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
AquaSeal PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 1006
 
AquaHeat PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe¢ § $$
 
PEX 1006
 
AquaHeat PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
AquaHeat PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
AquaHeat PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
AquaHeat PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
AquaHeat PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢ § $$
 
PEX 1006
 
Plumber Friendly PE-Xa Natural
 
ASTM F876/F877
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe¢ § $$
 
PEX 1006
 
Plumber Friendly PE-Xa Natural
 
CSA B137.5
3/8" - 6" SDR 9

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
$$ These products may also be produced with a clear, blue, orange or red barrier material
   on the outer layer of the tubing.

Pipe$ §
 
PEX 5006
 
Plumber Friendly PE-Xc Natural
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Plumber Friendly PE-Xc Black
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Plumber Friendly PE-Xc Blue
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe$ §
 
PEX 5006
 
Plumber Friendly PE-Xc Red
 
ASTM F876/F877
1/4" - 1" SDR 9

$ These products may also be produced with a blue, clear, or red barrier material on the
  outer layer of the tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
HDC Hyundai Engineering Plastics Co., Ltd. 
1221-32 Daehoman-ro, Seokmum-myeon
Dangjin-si, Chungnam 343-856 
Republic of Korea 
82 41 350 0593
Visit this company's website

Facility : Jincheon-Gun, Korea, Republic of

Potable Water - Materials

Material Type End Use Trade Name Product Standard
PEX 5006* ^ ¢ +++ 1 Polylink XP650/XC200 (Natural) N/A
PEX 5006* ^ ¢ +++ 1 Polylink XP650/XC200 (Black) N/A
PEX 5006* ^ ¢ +++ 1 Polylink XP650/XC200 (Red) N/A
PEX 5006* ^ ¢ +++ 1 Polylink XP650/XC200 (White) N/A

* Tubing manufactured using this material is cure process dependent.  Use of this material
  in NSF Certified tubing requires NSF's prior authorization.  Tubing produced from this
  material was tested to the health effects requirements of NSF/ANSI Standard 61 and the
  performance requirements of ASTM F876 and CSA B137.5.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).



 
Heatlink Group 
3615 32 Street NE
Calgary, AB T1Y 5Y9 
Canada 
403-717-3820

Facility : Calgary, Alberta, Canada

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing§ **
 
PEX
 
PureLink Plus
 
ASTM E84

1/2", 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing§ **
 
PEX
 
SureLink
 
ASTM E84

1/2", 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing! * ¢ § ++ [G]
 
PEX 5106
 
PureLink Plus
 
ASTM F876/F877
3/8" - 2"

! Certified for blue, natural, red colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ¢ § ++ [G]
 
PEX 5106
 
PureLink Plus
 
AWWA C904
1/2" - 2"  

! Certified for blue, natural, red colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ¢ § ++ [G]
 
PEX 5106
 
PureLink Plus
 
CSA B137.5
3/8" - 2"

! Certified for blue, natural, red colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ¢ § ++ [G]
 
PEX 5106
 
SureLink
 
ASTM F876/F877
3/8" - 2"

! Certified for blue, natural, red colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ¢ § ++ [G]
 
PEX 5106
 
SureLink
 
AWWA C904
1/2" - 2"  

! Certified for blue, natural, red colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! * ¢ § ++ [G]
 
PEX 5106
 
SureLink
 
CSA B137.5
3/8" - 2"

! Certified for blue, natural, red colors.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
++ Material complies with NSF/ANSI 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Reclaimed Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing¢
 
PEX 5106
 
PureLink Reclaim
 
ASTM F876/F877
3/8" - 1"

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.

Tubing¢
 
PEX 5106
 
PureLink Reclaim
 
CSA B137.5
3/8" - 1"

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing* @ ^ ¢ ¥
 
PEX 0306
 
HeatLink
 
ASTM F876/F877
3/8" - 1 1/2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This barrier tubing product has been evaluated against the performance requirements of
  ASTM F876/F877. This product is not NSF Certified for use in a potable water
  distribution system. This product has been evaluated for use in radiant floor heating
  (NSF-rfh) applications only.
^ Available in black, orange and red.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.

Tubing* @ ^ ¢ ¥
 
PEX
 
HeatLink
 
CSA B137.5
3/8" - 1 1/2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This barrier tubing product has been evaluated against the performance requirements of
  ASTM F876/F877. This product is not NSF Certified for use in a potable water
  distribution system. This product has been evaluated for use in radiant floor heating
  (NSF-rfh) applications only.
^ Available in black, orange and red.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.



 
HeatLink Group 
3615 32 Street Northeast
Calgary, AB T1Y 5Y9 
Canada 
800-661-5332 
403-717-3820
Visit this company's website

Facility : A Sweden

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing# *
 
PEX 0006
 
HeatLink (Natural tubing with O2 barrier)
 
ASTM F876/F877
3/8", 1/2", 5/8", 3/4", 1", 1 1/4", 1 1/2" SDR 9

# This barrier tubing product has been evaluated against the performance requirements of
  ASTM F876/F877.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.



 
HydroSmart, Inc. 
19974 Iguana Street
Elk River, MN 55330 
United States 
763-441-8303

Facility : # 2 Canada

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing! $ + ^ ~ ¢ £ § [G]
 
PEX 5006
 
HydroSmart™
 
ASTM F876/F877
1/4" - 2" (HSMPEXB) SDR 9

! Orange.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! $ + ^ ~ ¢ £ § [G]
 
PEX
 
HydroSmart™
 
CSA B137.5
1/4" – 2" (HSMPEXB) SDR 9

! Orange.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing! $ ^ ~ ¢ £ §
 
PEX 5006
 
HydroSmart™
 
ASTM F876/F877
1/4" - 2" (HSMPEXB) SDR 9

! Orange.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! $ ^ ~ ¢ £ §
 
PEX
 
HydroSmart™
 
CSA B137.5
1/4" – 2" (HSMPEXB) SDR 9

! Orange.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
Infloor Sales & Service 
503 Gregg Drive
Buena Vista, CO 81211 
United States 
800-608-0562 
719-395-3400
Visit this company's website

Facility : Peculiar, MO

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing! % ^ §
 
PEX 5006
 
BPEX Tubing Oxygen Barrier
 
ASTM F876/F877
1/8" - 1"

! Product may or may not bear the NSF U.P. code marking.
% Certified product is orange or natural in color.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing% ^ ¢
 
PEX 5006
 
BPEX Tubing Oxygen Barrier
 
CSA B137.5
1/8" - 1"

% Certified product is orange or natural in color.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.



 
IPEX Incorporated 
3 Place Du Commerce, Suite 101
Île-Des-Soeurs 
Verdun, QC H3E 1H7 
Canada 
514-769-2200
Visit this company's website

Facility : L'Assomption, Québec, Canada

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe^ ¢ § ** +++ [G]
 
PEX 5006
 
Blue 904
 
ASTM F876/F877
3/4" - 2" SDR 9

^ Meets the Chlorine Resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Certified Blue 904 tubing is blue in color.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe^ ¢ § ** +++ [G]
 
PEX 5006
 
Blue 904
 
AWWA C904
3/4" - 2" SDR 9

^ Meets the Chlorine Resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Certified Blue 904 tubing is blue in color.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe^ ¢ ** +++
 
PEX
 
Blue 904
 
CSA B137.5
3/4" - 2" SDR 9

^ Meets the Chlorine Resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
** Certified Blue 904 tubing is blue in color.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).



 
Kafrit NA Ltd. 
5411 - 275th Street
Langley, BC V4W 3X8 
Canada 
604-607-6730
Visit this company's website

Facility : Langley, British Columbia, Canada

Potable Water - Materials

Material Type End Use Trade Name Product Standard
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2410 CL Red N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2411 CL Blue N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2412 CL White N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2417 CL Black N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2418 CL Red N/A
PEX 5306^ +++ [1] 1 TA 1108 HD/TA 2419 CL White N/A
PEX 5006^ +++ [1] 1 TA 1108 HD/TA 2420 CL Natural N/A

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing manufactured using this material is cure process dependent.  Use of this material
    in NSF Certified tubing requires NSF's prior authorization.  Tubing produced from this
    material was tested to the performance requirements of ASTM F876 and CSA B137.5.  Tubing
    produced from this material is being evaluated for 1/4" and greater diameters.



 
Legend 
300 North Opdyke Road
Auburn Hills, MI 48326 
United States 
800-752-2082 
586-566-7400

Facility : D'Opaglio (NO), Italy

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Pipe
 
PEX
 
LegendFlex
 
ASTM F876/877
3/8" - 1"

Pipe
 
PEX
 
LegendFlex
 
CSA B137.5
3/8" - 1"



 
Leggett Supply Inc. DBA Flair-It Sales & Mobile Mart 
1701 South Cherokee
Muskogee, OK 74403 
United States 
918-681-2211

Facility : # 1 USA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe$ * ^ § +++
 
PEX 1006
 
SafePEX®
 
ASTM F876/F877
3/8" - 2" SDR 9

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe$ * ^ ¢ § +++
 
PEX 1006
 
SafePEX®
 
CSA B137.5
3/8" - 2" SDR

$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX Pro Blue UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX Pro Blue UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX Pro Red UV-Shield
 
ASTM F876/F877
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX Pro Red UV-Shield
 
CSA B137.5

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ § +++ [G]
 
PEX 1306
 
SafePEX Pro White UV-Shield
 
ASTM F876/F877

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* ^ ¢ § +++ [G]
 
PEX
 
SafePEX Pro White UV-Shield
 
CSA B137.5
3/8" - 2" SDR 9

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Mercury Plastics LLC 
15760 Madison Road
P.O. Box 989 
Middlefield, OH 44062 
United States 
440-632-5281

Facility : Middlefield, OH

Potable Water - Appurtenances

Product Type   Material Type   Trade Name   Product Standard

Refrigerator Supply Line# ¢ § [1] [G]
 
PEX
 
GE SmartConnect™
 
ASME A112.18.6/CSA B125.6
1/4 in. OD Tube

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Certified up to 8 feet in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Refrigerator Supply Line# ¢ § [2] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/8" C.T.S.

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[2] Certified up to 6 feet in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tank Tube/Riser PW# ¢ § [3] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Certified up to 20" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Basin Tube/Riser PW# ¢ § [4] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Dishwasher Supply Line# ¢ § [5] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/4" CTS X 3/8" OD

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[5] Certified up to 72" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Univ Dishwash Supply Line# ¢ § [5] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/4" CTS X 3/8" OD

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[5] Certified up to 72" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tank Tube/Riser PW# § [3] [G]
 
PEX
 
AQUAPEX
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Certified up to 20" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Basin Tube/Riser PW# § [4] [G]
 
PEX
 
AQUAPEX
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tank Tube/Riser PW# § [3] [G]
 
PEX
 
DURAPEX
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Certified up to 20" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Basin Tube/Riser PW# § [4] [G]
 
PEX
 
DURAPEX
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Basin Tube/Riser# ¢ [4] [6] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD - P2-XX-A
1/4" CTS x 3/8" OD - P2-XX-B

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Certified up to 96" in length.
[6] XX indicates length in inches.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Double Ended Hook-Up# ¢ [4] [6] [7] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
SEZ-XX-SB
SEZ-XX-ST

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Certified up to 96" in length.
[6] XX indicates length in inches.
[7] B indicates basin/lav end.
    T indicates closet/tank end.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

MEZ Double Ended Hook-Up# ¢ [4] [6] [8] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
MEZ-XX-PTW
MEZ-XX-PW9W
MEZ-XX-PW9W9
MEZ-XX-PWW

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Certified up to 96" in length.
[6] XX indicates length in inches.
[8] W9W denotes one 90-degree bend.
    W9W9 denotes two 90-degree bends.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tank Tube/Riser# ¢ [3] [6] [G]
 
PEX
 
Merflex® PEX OT®
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD - P2-XX-DL
1/4" CTS x 3/8" OD - P2-XX-T

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[3] Certified up to 20" in length.
[6] XX indicates length in inches.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Refrigerator Supply Line# ¢ § [2] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/8" C.T.S.

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[2] Certified up to 6 feet in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tank Tube/Riser PW# ¢ § [3] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Certified up to 20" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Basin Tube/Riser PW# ¢ § [4] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Dishwasher Supply Line# ¢ § [5] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[5] Certified up to 72" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Univ Dishwash Supply Line# ¢ § [5] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[5] Certified up to 72" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Basin Tube/Riser# ¢ [4] [6] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD - P2-XX-A
1/4" CTS x 3/8" OD - P2-XX-B

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Certified up to 96" in length.
[6] XX indicates length in inches.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Double Ended Hook-Up# ¢ [6] [7] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
SEZ-XX-SB[4]

SEZ-XX-ST[3]

[4] Certified up to 96" in length.
[3] Certified up to 20" in length.
# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[6] XX indicates length in inches.
[7] B indicates basin/lav end.
    T indicates closet/tank end.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

MEZ Double Ended Hook-Up# ¢ [4] [6] [8] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
MEZ-XX-PTW
MEZ-XX-PW9W
MEZ-XX-PW9W9
MEZ-XX-PWW

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[4] Certified up to 96" in length.
[6] XX indicates length in inches.
[8] W9W denotes one 90-degree bend.
    W9W9 denotes two 90-degree bends.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tank Tube/Riser# ¢ [3] [6] [G]
 
PEX
 
Zurn®PEX
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD - P2-XX-DL
1/4" CTS x 3/8" OD - P2-XX-T

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[3] Certified up to 20" in length.
[6] XX indicates length in inches.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Supply Tube Assembly PW§ [4] [G]
 
PEX
 
AJ Hookup
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Supply Tube Assembly PW§ [4] [G]
 
PEX
 
DLJ Hookup
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Supply Tube Assembly PW§ [G]
 
PEX
 
MEZ Hookup
 
ASME A112.18.6/CSA B125.6
1/4"[4]

3/8"[9]

[4] Certified up to 96" in length.
[9] Certified up to 60" in length.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Supply Tube Assembly PW§ [4] [G]
 
PEX
 
SEZ Hookup
 
ASME A112.18.6/CSA B125.6
1/4" I.D.

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[4] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing# * @ ^ ¢ § +++ [G]
 
PEX 5006
 
Embassy/LiquiPEX w/O2 Barrier
 
ASTM F876/F877
1/2" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# & * @ ¢ +++ [G]
 
PEX
 
Embassy/LiquiPEX w/O2 Barrier
 
CSA B137.5
1/2" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# @ ^ ¢ § +++ [G]
 
PEX 5006
 
Merflex® PEX OT®
 
ASTM F876/F877
1/8" - 1 1/4" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing@ ^ ¢ § +++ [G]
 
PEX 5006
 
Merflex® PEX OT®
 
ASTM F876/F877
1/8" CTS x 1/4" OD SDR 9

@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# & @ ¢ +++ [G]
 
PEX
 
Merflex® PEX OT®
 
CSA B137.5
1/8" - 1 1/4" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing& @ ¢ +++ [G]
 
PEX
 
Merflex® PEX OT®
 
CSA B137.5
1/8" CTS x 1/4" OD SDR 9

& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# * @ ^ ¢ § +++ [G]
 
PEX 5006
 
Merflex® PEX OT® Oxygen Barrier
 
ASTM F876/F877
1/2" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# & * @ ¢ +++ [G]
 
PEX
 
Merflex® PEX OT® Oxygen Barrier
 
CSA B137.5
1/2" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing@ ^ ¢ § +++ [G]
 
PEX 5006
 
PEXlink
 
ASTM F876/F877
1/8" - 1 1/4" SDR 9

@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing# * @ ^ ¢ §
 
PEX 5006
 
Embassy/LiquiPEX w/O2 Barrier
 
ASTM F876/F877
1/2" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# & * @ ¢
 
PEX
 
Embassy/LiquiPEX w/O2 Barrier
 
CSA B137.5
1/2" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.

Tubing# * @ ^ ¢ §
 
PEX 5006
 
Merflex® PEX OT® Oxygen Barrier
 
ASTM F876/F877
1/2" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# & * @ ¢
 
PEX
 
Merflex® PEX OT® Oxygen Barrier
 
CSA B137.5
1/2" - 1" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
* Product is barrier tubing.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.

Tubing# @ ^ ¢ §
 
PEX 5006
 
Merflex® PEX OT®
 
ASTM F876/F877
1/8" - 1 1/4" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing# & @ ¢
 
PEX
 
Merflex® PEX OT®
 
CSA B137.5
1/8" - 1 1/4" SDR 9

# Authorized for blue, gray, natural, orange, red, and white.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, if applicable, with the following fitting system designations:  ASTM F1807, ASTM
  F2159, ASTM F2098, ASTM F2080, ASSE 1061 and ASTM F1960.
@ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.



 
Mr PEX Systems (a division of Safelink Systems, Inc.) 
5300 Alpine Drive Northwest
Suite 210 
Ramsey, MN 55303 
United States 
800-716-3406 
952-440-7704

Facility : Ulricehamn, Sweden

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * @
 
PEX
 
Mr. PEX (Natural tubing)
 
ASTM F876/F877

3/8", 1/2", 5/8", 3/4", 1", 1 1/4", 1 1/2" SDR 9

$ Tubing tested as a system using Georg Fischer S.r.l. brass compression fittings which
  comply with ASTM F877.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ This tubing product has been evaluated against the performance requirements of ASTM
  F876/877.  This product is not NSF Certified for use in a potable water distribution
  system.  This product has been evaluated for use in radiant floor heating, (NSF-rfh),
  applications only.

Tubing# $ *
 
PEX
 
Mr. PEX (Red tubing with O2 barrier)
 
ASTM F876/F877
3/8", 1/2", 5/8", 3/4", 1", 1 1/4", 1 1/2" SDR 9

# This barrier tubing product has been evaluated against the performance requirements of
  ASTM F876/F877.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
$ Tubing tested as a system using Georg Fischer S.r.l. brass compression fittings which
  comply with ASTM F877.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.

Tubing# $ *
 
PEX
 
Mr. PEX (Natural tubing with O2 barrier)
 
ASTM F876/F877

3/8", 1/2", 5/8", 3/4", 1", 1 1/4", 1 1/2" SDR 9

# This barrier tubing product has been evaluated against the performance requirements of
  ASTM F876/F877.  This product is not NSF Certified for use in a potable water
  distribution system.  This product has been evaluated for use in radiant floor heating,
  (NSF-rfh), applications only.
$ Tubing tested as a system using Georg Fischer S.r.l. brass compression fittings which
  comply with ASTM F877.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.



 
Mueller Industries, Inc. 
8285 Tournament Drive
Suite 150 
Memphis, TN 38125 
United States 
901-751-7743

Facility : # 1 USA

Potable Water - Appurtenances

Product Type   Material Type   Trade Name   Product Standard

Basin Tube/Riser# ¢ [1] [G]
 
PEX
 
B&K
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[1] Certified up to 96" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tank Tube/Riser# ¢ [2] [G]
 
PEX
 
B&K
 
ASME A112.18.6/CSA B125.6
1/4" CTS x 3/8" OD

# This product may be marked via a flag type label.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] Certified up to 20" in length.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
NIBCO INC. 
World Headquarters
1516 Middlebury Street 
Elkhart, IN 46516-4740 
United States 
800-234-0227 
574-295-3000

Facility : # 1 Canada

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing! $ ^ ~ ¢ £ § +++ [G]
 
PEX 5006
 
NIBCO® PEX
 
ASTM F876/F877
1/4" - 2" (NP 75) SDR 9

! Orange.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing! $ ^ ~ ¢ £ § +++ [G]
 
PEX
 
NIBCO® PEX
 
CSA B137.5
1/4" – 2" (NP 75) SDR 9

! Orange.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ ? ^ ~ ¢ § +++ [G]
 
PEX 5306
 
NIBCO® PEX-R
 
ASTM F876/F877
3/8" - 2" (PR60, Red) SDR 9
3/8" - 2" (PR70, Blue) SDR 9
3/8" - 2" (PR80, White) SDR 9

$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is applicable to the blue, red, and white pipe.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing$ ? ^ ~ ¢ § +++ [G]
 
PEX
 
NIBCO® PEX-R
 
CSA B137.5
3/8" - 2" (PR60, Red) SDR 9
3/8" - 2" (PR70, Blue) SDR 9
3/8" - 2" (PR80, White) SDR 9

$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is applicable to the blue, red, and white pipe.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing! $ ^ ~ ¢ £ §
 
PEX 5006
 
NIBCO® PEX
 
ASTM F876/F877
1/4" - 2" (NP 75) SDR 9

! Orange.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing! $ ^ ~ ¢ £ §
 
PEX
 
NIBCO® PEX
 
CSA B137.5
1/4" – 2" (NP 75) SDR 9

! Orange.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ ? ^ ~ ¢ §
 
PEX 5306
 
NIBCO® PEX-R
 
ASTM F876/F877
3/8" - 2" (PR60, Red) SDR 9
3/8" - 2" (PR70, Blue) SDR 9
3/8" - 2" (PR80, White) SDR 9

$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is applicable to the blue, red, and white pipe.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing$ ? ^ ~ ¢ §
 
PEX
 
NIBCO® PEX-R
 
CSA B137.5
3/8" - 2" (PR60, Red) SDR 9
3/8" - 2" (PR70, Blue) SDR 9
3/8" - 2" (PR80, White) SDR 9

$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
  radiant heating system made in accordance with the current version of the ASTM F877
  standard intended for a maximum 100 psi water service and a maximum working temperature
  of 180°F.  System components consist of tubing and/or fittings.  To be installed in
  accordance with manufacturer’s instructions and the latest edition of the Uniform
  Plumbing Code™.
? The UV material type 5306 is applicable to the blue, red, and white pipe.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.