NSF Product and Service Listings
These NSF Official Listings are current as of Wednesday, February 5, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Pools/Listings.asp?Company=06200&Standard=050&
NSF/ANSI 50
Equipment for Swimming Pools, Spas, Hot Tubs
and Other Recreational Water Facilities
Equipment for Swimming Pools, Spas, Hot Tubs
and Other Recreational Water Facilities
Blue-White Industries, Ltd. | |
5300 Business Drive | |
Huntington Beach, CA 92649 | |
United States | |
714-893-8529 | |
Visit this company's website |
Facility : Huntington Beach, CA
Mechanical Chemical Feeding Equipment
A1A Series Chemical Feed Pumps[1] [2] |
||||||
A1A4-7T A1A8-7T | A1A5-7T A1A9-7T | A1A6-7T A1AX-7T | ||||
[1] Certified for Pool and Spa End Use [2] These pumps are approved for use with Sodium Hypochlorite (12.5%). |
||||||
A2A Series Chemical Feed Pumps[1] [3] |
||||||
A2A24-[X]NEE[4] | A2A24-[X]NGG[4] | A2A25-[X]NEE[5] | ||||
A2A25-[X]NGG[5] | A2A26-[X]NEE[6] | A2A26-[X]NGG[6] | ||||
[1] Certified for Pool and Spa End Use [3] X - Inlet/outlet connection type where "S" = 3/8" OD x 1/4" ID tubing and "M" = 1/2" male NPT [4] Voltage - 115V AC [5] Voltage - 230V AC [6] Voltage - 220V AC |
||||||
A2P Series Chemical Feed Pumps[1] [3] |
||||||
A2P24-[X]NEE[4] | A2P24-[X]NGG[4] | A2P25-[X]NEE[5] | ||||
A2P25-[X]NGG[5] | A2P26-[X]NEE[6] | A2P26-[X]NGG[6] | ||||
[1] Certified for Pool and Spa End Use [3] X - Inlet/outlet connection type where "S" = 3/8" OD x 1/4" ID tubing and "M" = 1/2" male NPT [4] Voltage - 115V AC [5] Voltage - 230V AC [6] Voltage - 220V AC |
||||||
Chem-Feed Hypochlorinators[1] [7] |
||||||
C-6125P-XXX-VAC | C-6125P-YY-VDC | C-614P-XXX-VAC | ||||
C-614P-YY-VDC | C-6250P-XXX-VAC | C-6250P-YY-VDC | ||||
C-630P-XXX-VAC | C-630P-YY-VDC | C-645P-XXX-VAC | ||||
C-645P-YY-VDC | C-660P-XXX-VAC | C-660P-YY-VDC | ||||
C15NabcdefgVhi[8] | C17NabcdefgVhi[9] | |||||
[1] Certified for Pool and Spa End Use [7] XXX - AC Power Supply Voltage (24, 115, 220, or 230) YY - DC Power Supply Voltage (12 or 24) [8] a - 0,1,2,3, or 4 b - 0,1,2,3,4,5,6, or 7 c - 1,2,3, or 4 d - X,A,I,J,K,L,P,R,T, or Z e - 0 or 5 f - 0 or 2 g - 0,1,6, or 7 h - 1,2,3,4,5,6,7,8,9, or X i - 0,1, or X [9] a - 0,1,2,3, or 4 b - 1,2,3,4,5,6,7,8, or 9 c - 1,2,3, or 4 d - X,A,I,J,K,L,P,R, or T e - 0 or 5 f - 0 or 2 g - 0,1,6, or 7 h - 0,1,4,5,6,7,8,9, or X i - 0,1, or X |
||||||
FlexFlo Peristaltic Pumps A-100N Series[10] |
||||||
A1N abc-de | ||||||
[10] a - Maximum motor RPM (0, 1, 2, or 3) b - Power supply (0, 1, 2, 5, 6, or 7) c - Output control (D, A, B, C, S, or X) d - Pump tube size and material (4, 6, or 7) e - Tubing connection type (T or Q) If a - 3, maximum working pressure is 75 psi If d - 7, maximum working pressure is 50 psi Units Listed for Pool and Spa/Hot Tub end use. Unless noted above, the maximum working pressure is 100 psi. |
Flow Metering Devices
Trade Designation | Pipe Size | Installation Orientation | Operational Range | Accuracy | Location | End Use |
F-300 Meters |
||||||
F-30100P[2] | 1" | Horizontal | 5 gpm – 35 gpm | L2 | Indoor/Outdoor | Pool or Spa/Hot Tub |
F-30125P[2] | 1 1/4" | Horizontal | 9 gpm - 50 gpm | L2 | Indoor/Outdoor | Pool or Spa/Hot Tub |
F-30150P[2] | 1 1/2" | Horizontal | 10 gpm - 70 gpm | L2 | Indoor/Outdoor | Pool or Spa/Hot Tub |
F-30200P[2] | 2" | Horizontal | 20 gpm - 120 gpm | L2 | Indoor/Outdoor | Pool or Spa/Hot Tub |
F-30250P[3] | 2.5" | Horizontal | 29 gpm - 150 gpm | L3 | Indoor/Outdoor | Pool or Spa/Hot Tub |
F-30300P[3] | 3" | Horizontal | 45 gpm - 240 gpm | L3 | Indoor/Outdoor | Pool or Spa/Hot Tub |
F-30400P[3] | 4" | Horizontal | 75 gpm - 420 gpm | L3 | Indoor/Outdoor | Pool or Spa/Hot Tub |
F-30600P[3] | 6" | Horizontal | 170gpm - 1100gpm | L3 | Indoor/Outdoor | Pool or Spa/Hot Tub |
F-30800P[3] | 8" | Horizontal | 500 gpm-1900 gpm | L3 | Indoor/Outdoor | Pool or Spa/Hot Tub |
[1] For use with straight pipe run lengths of 20 (twenty) times the nominal pipe diameter before and after the flow meter, or less as recommended by the manufacturer. [2] To achieve level 2 (L2) flow meter accuracy rating, the average of testing results across the manufacturers claimed full scale of flow rate must be <= 5.0% of actual flow rate. The greatest deviation of any one tested flow rate from the actual shall be no greater than ± 7.5% at a tested flow rate. [3] To achieve level 3 (L3) flow meter accuracy rating, the average of testing results across the manufacturers claimed full scale of flow rate must be < 10.0% of actual flow rate. The greatest deviation of any one tested flow rate from the actual shall be no greater than ± 12.5% at a tested flow rate. |
Number of matching Manufacturers is 1
Number of matching Products is 39
Processing time was 0 seconds