NSF Product and Service Listings

These NSF Official Listings are current as of Wednesday, May 8, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Pools/Listings.asp?Company=06200&Standard=050&


NSF/ANSI 50
Equipment for Swimming Pools, Spas, Hot Tubs
and Other Recreational Water Facilities



 
Blue-White Industries, Ltd. 
5300 Business Drive
Huntington Beach, CA 92649 
United States 
714-893-8529
Visit this company's website

Facility : Huntington Beach, CA

Mechanical Chemical Feeding Equipment

A1A Series Chemical Feed Pumps[1] [2]
A1A4-7T A1A8-7T A1A5-7T A1A9-7T A1A6-7T A1AX-7T  

[1] Certified for Pool and Spa End Use
[2] These pumps are approved for use with Sodium Hypochlorite (12.5%).

A2A Series Chemical Feed Pumps[1] [3]
A2A24-[X]NEE[4] A2A24-[X]NGG[4] A2A25-[X]NEE[5]  
A2A25-[X]NGG[5] A2A26-[X]NEE[6] A2A26-[X]NGG[6]  

[1] Certified for Pool and Spa End Use
[3] X - Inlet/outlet connection type where "S" = 3/8" OD x 1/4" ID tubing and "M" = 1/2"
    male NPT
[4] Voltage - 115V AC
[5] Voltage - 230V AC
[6] Voltage - 220V AC

A2P Series Chemical Feed Pumps[1] [3]
A2P24-[X]NEE[4] A2P24-[X]NGG[4] A2P25-[X]NEE[5]  
A2P25-[X]NGG[5] A2P26-[X]NEE[6] A2P26-[X]NGG[6]  

[1] Certified for Pool and Spa End Use
[3] X - Inlet/outlet connection type where "S" = 3/8" OD x 1/4" ID tubing and "M" = 1/2"
    male NPT
[4] Voltage - 115V AC
[5] Voltage - 230V AC
[6] Voltage - 220V AC

Chem-Feed Hypochlorinators[1] [7]
C-6125P-XXX-VAC C-6125P-YY-VDC C-614P-XXX-VAC  
C-614P-YY-VDC C-6250P-XXX-VAC C-6250P-YY-VDC  
C-630P-XXX-VAC C-630P-YY-VDC C-645P-XXX-VAC  
C-645P-YY-VDC C-660P-XXX-VAC C-660P-YY-VDC  
C15NabcdefgVhi[8] C17NabcdefgVhi[9]  

[1] Certified for Pool and Spa End Use
[7] XXX - AC Power Supply Voltage (24, 115, 220, or 230)
    YY  - DC Power Supply Voltage (12 or 24)
[8] a - 0,1,2,3, or 4
    b - 0,1,2,3,4,5,6, or 7
    c - 1,2,3, or 4
    d - X,A,I,J,K,L,P,R,T, or Z
    e - 0 or 5
    f - 0 or 2
    g - 0,1,6, or 7
    h - 1,2,3,4,5,6,7,8,9, or X
    i - 0,1, or X
[9] a - 0,1,2,3, or 4
    b - 1,2,3,4,5,6,7,8, or 9
    c - 1,2,3, or 4
    d - X,A,I,J,K,L,P,R, or T
    e - 0 or 5
    f - 0 or 2
    g - 0,1,6, or 7
    h - 0,1,4,5,6,7,8,9, or X
    i - 0,1, or X

FlexFlo Peristaltic Pumps A-100N Series[10]
A1N abc-de  

[10] a - Maximum motor RPM (0, 1, 2, or 3)
     b - Power supply (0, 1, 2, 5, 6, or 7)
     c - Output control (D, A, B, C, S, or X)
     d - Pump tube size and material (4, 6, or 7)
     e - Tubing connection type (T or Q)
     If a - 3, maximum working pressure is 75 psi
     If d - 7, maximum working pressure is 50 psi
     Units Listed for Pool and Spa/Hot Tub end use.  Unless noted above, the maximum working
     pressure is 100 psi.



Flow Metering Devices
Trade Designation Pipe Size Installation Orientation Operational Range Accuracy Location End Use

F-300 Meters
F-30100P 1" Horizontal 5 gpm – 35 gpm [L2] Indoor/Outdoor Pool or Spa/Hot Tub
F-30125P 1 1/4" Horizontal 9 gpm - 50 gpm [L2] Indoor/Outdoor Pool or Spa/Hot Tub
F-30150P 1 1/2" Horizontal 10 gpm - 70 gpm [L2] Indoor/Outdoor Pool or Spa/Hot Tub
F-30200P 2" Horizontal 20 gpm - 120 gpm [L2] Indoor/Outdoor Pool or Spa/Hot Tub
F-30250P 2.5" Horizontal 29 gpm - 150 gpm [L3] Indoor/Outdoor Pool or Spa/Hot Tub
F-30300P 3" Horizontal 45 gpm - 240 gpm [L3] Indoor/Outdoor Pool or Spa/Hot Tub
F-30400P 4" Horizontal 75 gpm - 420 gpm [L3] Indoor/Outdoor Pool or Spa/Hot Tub
F-30600P 6" Horizontal 170gpm - 1100gpm [L3] Indoor/Outdoor Pool or Spa/Hot Tub
F-30800P 8" Horizontal 500 gpm-1900 gpm [L3] Indoor/Outdoor Pool or Spa/Hot Tub

[1] For use with straight pipe run lengths of 20 (twenty) times the nominal pipe diameter
    before and after the flow meter, or less as recommended by the manufacturer.


[L2] To achieve level 2 (L2) flow meter accuracy rating, the average of testing results
     across the manufacturers claimed full scale of flow rate must be <= 5.0% of actual flow
     rate.  The greatest deviation of any one tested flow rate from the actual shall be no
     greater than ± 7.5% at a tested flow rate.
[L3] To achieve level 3 (L3) flow meter accuracy rating, the average of testing results
     across the manufacturers claimed full scale of flow rate must be < 10.0% of actual flow
     rate. The greatest deviation of any one tested flow rate from the actual shall be no
     greater than ± 12.5% at a tested flow rate.

Number of matching Manufacturers is 1
Number of matching Products is 39