NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
Master Builders Solutions Admixtures US, LLC | |
23700 Chagrin Boulevard | |
Cleveland, OH 44122 | |
United States | |
800-628-9990 | |
216-839-7500 | |
Visit this company's website |
Facility : # 1 USA
Joining and Sealing Materials
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Grouts[1] [2] |
||||
MasterRoc MP 355 1K | [3] | CLD 23 | PUR | |
MasterRoc MP 355 1K Accelerator | [3] | CLD 23 | PUR | |
[1] Minimum cure time is 0.25 hours at 40°F. Mix ratio of Resin:Accelerator is 90:10 by volume. [2] MasterRoc MP 355 1K Accelerator is only certified for use with MasterRoc MP 355 1K. [3] Certified for use in tanks at maximum surface area to volume ratio of 0.26 square centimeters per liter. |
Facility : # 2 USA
Joining and Sealing Materials
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Grout[1] |
||||
Master Roc MP 351 LV | [3] | CLD 23 | PUR | |
Master Roc MP 351 LV Accelerator[2] | [3] | CLD 23 | PUR | |
[1] Minimum cure time is 0.25 hours at 40°F. Mix ratio of Resin:Accelerator is 90:10 by volume. [2] MasterRoc MP 351 LV Accelerator is only certified for use with MasterRoc MP 351 LV. [3] Certified for use in tanks at maximum surface area to volume ratio of 0.26 square centimeters per liter. |
Facility : Cucamonga, CA
Protective (Barrier) Materials
Water | Water | |||
Water Contact | Contact | Contact | ||
Trade Designation | Size Restriction | Temp | Material | |
Concrete Admixtures[1] |
||||
MasterLife CRA 007 | [2] | CLD 23 | CMNT | |
MasterLife® SRA 035 | [3] | CLD 23 | CMNT | |
MasterPozzolith 322 | [4] | CLD 23 | CMNT | |
MasterPozzolith 700 | [5] | CLD 23 | CMNT | |
MasterSure Z 60 | [6] | CLD 23 | CMNT | |
Pozzolith 322N | [4] | CLD 23 | CMNT | |
Pozzolith® 700N | [5] | CLD 23 | CMNT | |
RheoTEC Z-60 | [6] | CLD 23 | CMNT | |
[1] All Listed products from this facility are NSF Certified, whether or not they bear the NSF Mark. [2] Certified for a maximum use level not to exceed 2 gallons per cubic yard of concrete. Certified for use in tanks 70,000 gallons and greater. [3] Certified for a maximum use level of 1.5 gallons per cubic yard of concrete. Certified for use in tanks 200,000 gallons and greater and pipes 120 inches and greater. [4] Certified for a maximum use level of 7 fluid ounces per 100 pounds of cement. Certified for use in tanks 1500 gallons and greater and pipes and fittings 36" and greater. [5] Certified for a maximum use level of 5 fluid ounces per 100 pounds of cement. Certified for use in tanks 200 gallons and greater and pipes and fittings 8 inches and greater. [6] Certified for use in tanks 200 gallons and greater and pipes and fittings 6" and greater. Certified for a maximum use level of 12 fluid ounces per 100 pounds of cement. |
Facility : Newark, CA
Protective (Barrier) Materials
Water | Water | |||
Water Contact | Contact | Contact | ||
Trade Designation | Size Restriction | Temp | Material | |
Concrete Admixtures[1] |
||||
MasterLife 300C[2] | [3] | CLD 23 | CMNT | |
MasterLife 300C Red[2] | [3] | CLD 23 | CMNT | |
MasterLife 300D [4] | [3] | CLD 23 | CMNT | |
MasterLife 300D Red[4] | [3] | CLD 23 | CMNT | |
MasterLife 300L[5] | [3] | CLD 23 | CMNT | |
PS-1730[5] | [3] | CLD 23 | CMNT | |
PS-1799[5] | [3] | CLD 23 | CMNT | |
[1] All Listed products from this facility are NSF Certified, whether or not they bear the NSF Mark. [2] Certified for a level not to exceed 1% of cement content by mass. [3] Certified for use in tanks 200 gallons and greater and pipes and fittings 6" and greater. [4] Certified for a level not to exceed 2.5% of cement content by mass. [5] Certified for a maximum use level of 1.25 gallons per cubic yard of concrete. |
Facility : Allentown, PA
Protective (Barrier) Materials
Water | Water | |||
Water Contact | Contact | Contact | ||
Trade Designation | Size Restriction | Temp | Material | |
Concrete Admixtures[1] |
||||
Glenium 3030 NS | [2] | CLD 23 | CMNT | |
Glenium 3400 NV | [3] | CLD 23 | CMNT | |
MB AE 90 | [4] | CLD 23 | CMNT | |
MB VR Standard | [4] | CLD 23 | CMNT | |
MasterAir AE 90 | [4] | CLD 23 | CMNT | |
MasterAir VR 10 | [4] | CLD 23 | CMNT | |
MasterGlenium 3030 | [2] | CLD 23 | CMNT | |
MasterGlenium 3400 | [3] | CLD 23 | CMNT | |
Master Glenium 7620 | [5] | CLD 23 | CMNT | |
MasterGlenium 7920 | [5] | CLD 23 | CMNT | |
MasterGlenium 7925 | [5] | CLD 23 | CMNT | |
MasterPolyHeed 997 | [6] | CLD 23 | CMNT | |
MasterPozzolith 200 | [7] | CLD 23 | CMNT | |
MasterRheobuild 1000 | [8] | CLD 23 | CMNT | |
MasterSet AC 534 | [9] | CLD 23 | CMNT | |
MasterSet R 100 | [7] | CLD 23 | CMNT | |
PolyHeed 997 | [6] | CLD 23 | CMNT | |
Pozzolith 100XR | [7] | CLD 23 | CMNT | |
Pozzolith 200N | [7] | CLD 23 | CMNT | |
Pozzolith NC 534 | [9] | CLD 23 | CMNT | |
Rheobuild 1000 | [8] | CLD 23 | CMNT | |
[1] All Listed products from this facility are NSF Certified, whether or not they bear the NSF Mark. [2] Maximum use level not to exceed 18 fl. oz. per 100 lbs. of cement. Certified for use in pipes 4" and greater, and in tanks 200 gallons and greater. [3] Maximum use level not to exceed 12 fl. oz. per 100 lbs. of cement. Certified for use in pipes 6" and greater, and in tanks 100 gallons and greater. [4] Certified for a level not to exceed 1.5 fluid oz. per 100 pounds of cement. Certified for use in pipes 8" and greater, tanks 200 gallons and greater. [5] Certified for a level not to exceed 15 fluid oz. per 100 pounds of cement. Certified for use in tanks 200 gallons and greater and pipes 6" in diameter and greater. [6] Maximum use level not to exceed 15 fl. oz. per 100 lbs. of cement. Certified for use in pipes 20" and greater, and in tanks 400 gallons and greater. [7] Maximum use level not to exceed 5 fl. oz. per 100 lbs. of cement. Certified for use in pipes 20" and greater. [8] Maximum use level not to exceed 20 fl. oz. per 100 lbs. of cement. Certified for use in pipes 6" and greater. [9] Maximum use level not to exceed 30 fl. oz. per 100 lbs. of cement. Certified for use in pipes 10" and greater, tanks 200 gallons and greater, and fittings 6" in diameter and greater. |
Facility : Lancaster, TX
Protective (Barrier) Materials
Water | Water | |||
Water Contact | Contact | Contact | ||
Trade Designation | Size Restriction | Temp | Material | |
Concrete Admixtures[1] |
||||
Delvo Stabilizer | [2] | CLD 23 | CMNT | |
Glenium 7500 | [3] | CLD 23 | CMNT | |
Glenium 7700 | [4] | CLD 23 | CMNT | |
Master Glenium 7620 | [5] [6] | CLD 23 | CMNT | |
MasterGlenium 1466 | [7] | CLD 23 | CMNT | |
MasterGlenium 7500 | [3] | CLD 23 | CMNT | |
MasterGlenium 7700 | [4] | CLD 23 | CMNT | |
MasterGlenium 7920 | [5] [6] | CLD 23 | CMNT | |
MasterGlenium 7925 | [5] [6] | CLD 23 | CMNT | |
MasterPolyheed 1020 | [8] [9] | CLD 23 | CMNT | |
MasterSet DELVO | [2] | CLD 23 | CMNT | |
[1] All Listed products from this facility are NSF Certified, whether or not they bear the NSF Mark. [2] Certified for a level not to exceed 5 fluid oz. per 100 pounds of cement. Certified for use in pipes 4'' and greater, tanks 200 gallons and greater. [3] Certified for a level not to exceed 15 fluid oz. per 100 pounds of cement. Certified for use in pipes 18" in diameter and greater, tanks 200 gallons and greater. [4] Certified for a level not to exceed 15 fluid oz. per 100 pounds of cement. Certified for use in pipes 6" and greater, tanks 200 gallons and greater. [5] Certified for use in tanks 200 gallons and greater and pipes and fittings 6" diameter and greater. [6] Certified for a level not to exceed 15 fluid oz. per 100 pounds of cement. [7] Certified for a maximum use level of 10 fluid oz. per 100 pounds of cement. Certified for use in tanks 200 gallons and greater and pipes and fittings 6" diameter and greater. [8] Certified for a maximum use level of 12 fl. oz. per 100 lbs. cement. [9] Certified for use in tanks 500,000 gallons and greater and fittings 6" diameter and greater. |
Facility : Nisku, Alberta, Canada
Protective (Barrier) Materials
Water | Water | |||
Water Contact | Contact | Contact | ||
Trade Designation | Size Restriction | Temp | Material | |
Concrete Admixtures[1] |
||||
MasterAir AE 200[2] | [3] | CLD 23 | CMNT | |
MasterPolyheed 980[4] | [5] | CLD 23 | CMNT | |
MasterPozzolith 210[6] | [7] | CLD 23 | CMNT | |
MasterSet R 122[6] | [7] | CLD 23 | CMNT | |
MasterSet R 961[6] | [7] | CLD 23 | CMNT | |
Micro Air®[2] | [3] | CLD 23 | CMNT | |
Pozzolith 122R[6] | [7] | CLD 23 | CMNT | |
Pozzolith 961R[6] | [7] | CLD 23 | CMNT | |
[1] All Listed products from this facility are NSF Certified, whether or not they bear the NSF Mark. [2] Certified for a maximum use level of 1.5 fl. oz. per 100 pounds of cement. [3] Certified for use in tanks 200 gallons and greater and pipes and fittings 8" and greater. [4] Certified for a use level of 12.0 fluid ounces per 100 pounds of cement. [5] Certified for use in tanks 1500 gallons and greater, pipe 36" and greater, and fittings 20" and greater. [6] Certified for a maximum use level of 5 fl. oz. per 100 pounds of cement. [7] Certified for use in pipes 16" diameter and greater, tanks 200 gallons and greater. |
Number of matching Manufacturers is 1
Number of matching Products is 59
Processing time was 1 seconds