NSF Product and Service Listings
These NSF Official Listings are current as of Saturday, November 23, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsChemicals/Listings.asp?Company=0U670&Standard=060&
NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
Jutzi Water Technologies | |
525 Wright Boulevard | |
Stratford, ON N4A 6T1 | |
Canada | |
519-814-9283 | |
Visit this company's website |
Facility : Stratford, Ontario, Canada
Citric Acid[1] |
||
Trade Designation | Product Function | Max Use |
Citric Acid 50% | Membrane Cleaner | N/A |
[1] This product is designed to be used off-line and flushed out prior to using the system for drinking water, following manufacturer's use instructions. |
Hydrogen Peroxide[HP] |
||
Trade Designation | Product Function | Max Use |
Hydrogen Peroxide 35 | Oxidant | 3mg/L |
[HP] Use of this product shall be followed by chlorination to remove levels of hydrogen peroxide. Chlorine residuals shall not exceed 4 mg/L, the EPA's proposed maximum residual level. |
Polyaluminum Chloride[AL] |
||
Trade Designation | Product Function | Max Use |
Formula WW 8320 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished drinking water shall not exceed 2 mg/L. |
Potassium Permanganate[PO] |
||
Trade Designation | Product Function | Max Use |
Potassium Permanganate 02 | Disinfection & Oxidation | 2500mg/L |
Potassium Permanganate 04 | Disinfection & Oxidation | 1250mg/L |
Potassium Permanganate 100 | Disinfection & Oxidation | 50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese do not exceed 0.05 mg/L. |
Sodium Bisulfite[2] |
||
Trade Designation | Product Function | Max Use |
Formula OS 5305 | Dechlorination | 50mg/L |
[2] This product contains sulfite. Sulfites have been known to cause potentially lethal allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L). |
Sodium Hydroxide |
||
Trade Designation | Product Function | Max Use |
Sodium Hydroxide 25 | pH Adjustment | 200mg/L |
Sodium Hydroxide 50 | pH Adjustment | 100mg/L |
Sodium Hypochlorite[HY] |
||
Trade Designation | Product Function | Max Use |
Liquid Chlorine 06 | Disinfection & Oxidation | 170mg/L |
Liquid Chlorine 12 | Disinfection & Oxidation | 85mg/L |
[HY] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the finished drinking water to ensure compliance to all applicable regulations. Also, reference the AWWA B300 (Hypochlorites) standard's Recommendations for the Handling and Storage of Hypochlorite Solutions appendix for information on preservation techniques for hypochlorite bleach in transit and storage. |
Sodium Polyphosphates, Glassy |
||
Trade Designation | Product Function | Max Use |
Formula PW 1640 | Corrosion & Scale Control | 50mg/L |
Formula PW 1680 | Corrosion & Scale Control | 25mg/L |
Sodium Silicate |
||
Trade Designation | Product Function | Max Use |
Sodium Silicate N | Corrosion & Scale Control | 42mg/L |
Number of matching Manufacturers is 1
Number of matching Products is 14
Processing time was 0 seconds